Surface Mounted Fixture

3

Three Way Light Switch

Hatch Designates Area Not In Contract Or Existing

Ceiling Surface Mounted Pendant Fixture

D

Dimmer Switch

Light Track and Fixtures

ALIGN

C1: Wall Mounted Sconce Fixture

Suspended Acoustical Ceiling Grid

X2: Double faced exit Sign (Arrow if Directional Required)

PL-2

M1: Strip light

PL-1

X1: Single faced exit sign

G1: Recessed 2' X 4' Fluorescent Fixture EXTENT OF ACCENT FINISH

Wiring Arc - Indicates Switching of Fixtures/Devices.

PT-1

GX: Recessed 2' X 4' Fluorescent Fixture with Emergency Circuit

CP-1 FLOOR TRANSITION

Recessed 2' X 2' Fluorescent Fixture VT-1 FINISH TAG: CEILING TYPE WALL FINISH BASE TYPE FLOOR FINISH

ALL ABOVE CEILING SYSTEMS SHALL BE DESIGNED TO ACCOMMODATE CEILING HEIGHTS DOCUMENTED AND CEILING FIXTURES SPECIFIED. CEILING DROPS WILL NOT BE CONSIDERED TO ACCOMMODATE REROUTING OF SYSTEMS.

ALL CEILING ELEMENTS SHALL BE CENTERED IN TILE, UNLESS NOTED OTHERWISE.

ALL LIGHTING AND/OR SWITCHING SHALL BE COORDINATED WITH BASIC BUILDING SYSTEMS. REFER TO BUILDING REPRESENTATIVE FOR REQUIREMENTS.

Recessed 2' X 2' Fluorescent Fixture With Emergency Circuit

GFI

Ground Fault Interrupt Receptacle Location

SPRINKLER HEADS LOCATED IN ACOUSTIC CEILING TILE ARE TO BE CENTERED IN TILE AND HEADS IN GYPSUM BOARD CEILINGS ARE TO BE CONCEALED HEAD TYPE TYPICALLY.

SUPPLY AND INSTALL NEW CEILING TILE, GRID, AND LIGHT FIXTURES.

R

Indicates Electrical Component to be Relocated

E

Indicates Existing Electrical Component to Remain

J

Junction Box Above Ceiling

RB-1

CP-1

SWITCHES ARE TO BE MOUNTED TO ALIGN WITH THE CENTERLINE OF THE DOOR LEVER 42" AFF. EACH ROOM TO BE SWITCHED INDIVIDUALLY UNLESS NOTED OTHERWISE.

3

TRACK LIGHT TO BE SUSPENDED AT 30" OFF FACE OF LOGO.

4

PENDANTS TO BE PROVIDED BY OWNER. COORDINATE EXACT HEIGHT AND LOCATION PRIOR TO INSTALLATION.

5

DETERMINE EXACT LOCATION OF BLOCKING WITH OWNER PRIOR TO INSTALLATION.

A2

TYPE OF FIXTURE: HALLWAY PENDANT MANUFACTURER: ROBERT ABBEY, INC. STYLE: RICO ESPINET CANDELARIA CHANDELIER MODEL #: Z21012 FINISH: DEEP PATINA BRONZE DIMENSION: 15.5"W x 28.25"H LAMP: 2

M1 TYPE OF FIXTURE: CLOSET MANUFACTURER: LITHONIA STYLE/MODEL #: C 232 MVOLT GEB 101S LAMP: 2 G1

TYPE OF FIXTURE: CHANDELIER MANUFACTURER: KICHIER STYLE/MODEL #: 2347N1-JCMOD LAMP: 2

X1 TYPE OF FIXTURE: SINGLE FACE EXIT MANUFACTURER: LITHONIA STYLE/MODEL #: EDGR 1 R EL

C2 TYPE OF FIXTURE: RESTROOM VANITY MANUFACTURER: KICHIER STYLE/MODEL #: 45221 N-JCMOD LAMQ: 1 D1

NOTE: FINALIZE ALL LIGHTING SPECIFICATIONS WITH TENANT. CONTRACTOR TO COORDINATE EXACT CEILING FIXTURE HEIGHTS PRIOR TO OR AT THE TIME OF INSTALL.

TYPE OF FIXTURE: LAY IN FIXTURE MANUFACTURER: LITHONIA STYLE/MODEL #: 2GT8 2 32 A12125 MVOLT GEB 101S LAMQ: 2

GX TYPE OF FIXTURE: EMERGENCY LAY IN MANUFACTURER: LITHONIA STYLE/MODEL #: 2GT8 2 32 A12125 MVOLT GEB 101S EL LAMP: 2

C1 TYPE OF FIXTURE: WALL SCONCE MANUFACTURER: LUMENS STYLE: CHELSEA SCONCE MODEL #: 4290.25 LAMP: 1

PROVIDE LINE ITEM PRICING FOR (4) SKYLIGHTS 33 1/2" X 33 1/2" AS INDICATED ON THE PLAN, MANUFACTURER TO BE DETERMINED BY CONTRACTOR. NOTE: LIGHTING FIXTURES ARE SUBJECT TO CHANGE. CONTRACTOR TO VERIFY WITH TENANT PRIOR TO ORDERING FIXTURES.

A2: Recessed Fluorescent Downlight (EM Indicates Emergency Ballast)

LED Wall Washer

NOT USED.

6

NEW EXIT SIGNS AND EMERGENCY LIGHTING. CONTRACTOR SHALL EVALUATE LOCATION OF THESE FIXTURES AND MODIFY IF NECESSARY TO ACCOMMODATE NEW CONSTRUCTION AND TO COMPLY WITH CODES.

Emergency light fixture

Recessed Fluorescent Wall Washer

2

A1

SWITCH NEW, EXISTING AND RELOCATED FIXTURES AS INDICATED. EXISTING SWITCH LOCATIONS ARE NOTED AS "E".

AC-1 PT-1

PROVIDE AND INSTALL SUSPENDED CAN LIGHT FIXTURES IN LOBBY, MOUNTED AT 96" A.F.F.

X2 TYPE OF FIXTURE: DOUBLE FACE EXIT MANUFACTURER: LITHONIA STYLE/MODEL #: EDGR 2 RMR EL X3 TYPE OF FIXTURE: EMERGENCY MANUFACTURER: LITHONIA STYLE/MODEL #: ELM2 B

TYPE OF FIXTURE: RECESSED DOWN LIGHT MANUFACTURER: LITHONIA STYLE/MODEL #: LF6N- 1/26-42TRT F60 1A MVOLT LAMP: 1

D2 TYPE OF FIXTURE MONOPOINT MANUFACTURER: NORA LIGHTING STYLE/MODEL #: NTH-1 12-B-E2 1/NTH-319-B/NT-324-B LAMP: 1

NOTE: Switching within Office Spaces to be controlled via dual switching or occupancy / motion sensor, as per International Energy Conservation Code

design group llc. 100 taylor street|studio a10 nashville,tn 37208 (c)931.265.1602 www.sw-design-group.com

NOTE: EMERGENCY LIGHTING LAYOUT IS SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL EVALUATE EMERGENCY LIGHTING LOCATIONS AND COORDINATE WITH INDICATED DESIGN INTENT. EMERGENCY LIGHTING SHALL COMPLY WITH CODE REQUIREMENTS.

NOTE: CONTRACTOR TO PROVIDE AND INSTALL NEW CEILING GRID. NEW CEILING AND LIGHT FIXTURES IN THIS AREA TO BE. Manufacturer: Lightolier Type: HP90 with two 28 watt T5 Lamps Product No: H9S2GLR228120WA Size: 2' x 4'

A1

A1 4

A1

A1

A1

4

4

4

A1

5

NOTE: LIGHTING LAYOUT AND SWITCHING IS FOR DESIGN INTENT ONLY. FINAL LIGHTING LAYOUT TO BE DETERMINED BY ENGINEER'S OR CONTRACTOR'S CALCULATIONS AND COMPLIANCE WITH THE INTERNATIONAL ENERGY CONSERVATION CODE AS REQUIRED BY JURISDICTION.

4

ROOMS ARE TO HAVE OCCUPANCY/MOTION PHOTO SENSORS, OR DUAL SWITCHING, IN COMPLIANCE WITH THE INTERNATIONAL ENERGY CONSERVATION CODE.

6 4 5 1

A1

A1

A1

A1

A1

4 4 35'-6"

3'-1"

43'-0" 4

4 5

3

RCP PLAN

MILLWORK FINISHES: WALL/BASE CABINETS COUNTER TOP

CEILING ELEMENTS (LIGHTING FIXTURES, MECHANICAL DIFFUSERS, SPRINKLER HEADS, ETC. ARE SHOWN FOR LAYOUT AND DESIGN INTENT ONLY. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION.

REFER TO GENERAL NOTES SHEET G0.0 FOR GENERAL CONDITIONS AND REQUIREMENTS FOR ALL CONSTRUCTION.

Hatch Designates Drywall Soffit Recessed Projection Screen

ALIGN FINISHED FACE OF PARTITION WITH SURFACES INDICATED

CONTRACTOR TO PERFORM THE WORK OUTLINED IN THESE NOTES IN ALL AREAS OF CONSTRUCTION UNLESS NOTED OTHERWISE IN THESE DOCUMENTS.

DESIGN MECHANICAL SYSTEM TO PROVIDE SEPARATE ZONING FOR EACH EXPOSURE. BALANCE ALL ZONES AFFECTED BY CONSTRUCTION. PROVIDE TEST AND BALANCE REPORT TO BUILDING OWNER AND ARCHITECT FOR REVIEW. A COPY OF THE BALANCE INFORMATION SHALL BE SUBMITTED TO BUILDING REPRESENTATIVE UPON COMPLETION OF THE WORK.

1

5

X3 X1

A1

A1

A1

M1

5

A1

5

A1

A1

A1 6

A1

A1

A1

6

A1

A1

5

A1

A1

A1 6

4

9'-6" AC-1

A1

4 9'-6" AC-1

C2 C2

33'-1"

LIMIT OF CONSTRUCTION

CAP WALL w/ METAL TRACK

CONTRACTOR'S OPTION: STABILIZE WALL w/ KICKERS OR w/ STUDS EXTENDED TO DECK @ 4'-0" O.C., MAX. .

CAP WALL w/ METAL TRACK

6"

1 A1.1

CONTRACTOR SHALL PERFORM THE WORK INDICATED BY THESE NOTES IN AREAS DESIGNATED ON THE PLAN SPECIFIC KEYNOTE NUMBER.

ALL ADJACENT SWITCHES SHALL BE GANGED IN A SINGLE BOX WITH A SINGLE COVER PLATE. IF GANGING OF SWITCHES IS NOT POSSIBLE, INDIVIDUAL SWITCHES SHALL BE SPACED AN EQUAL AND MINIMUM DISTANCE APART AND LOCATED AT THE SAME ELEVATION AFF. STACKING OF SWITCHES MAY BE NECESSARY IF THE NUMBER IS EXCESSIVE.

5/8" GYP. BD, EA. SIDE

5/8" GYP. BD, EA. SIDE

METAL STUDS @ 16" O.C. MAX.

METAL STUDS @ 16" O.C. MAX. PARTITION CONSTRUCTION: 3-5/8" METAL STUDS (25 GA. MIN.) @ 16" O.C. MAX., w/ ONE LAYER OF 5/8" GYP. BD EA. SIDE; TERMINATING 6" ABOVE CEILING

SPECIFIED BASE, TYP. - SEE FINISH PLAN SPECIFIED FLOORING, TYP. - SEE FINISH PLAN

STUD WALL TO 18" ABOVE CEILING 9'-6" NON-RATED PARTITION ACCOUSTICAL

NOTE: CEILING HEIGHT FOR ALL SUITES TO BE 9'-6" A.F.F. WALL HEIGHTS VARY: ALL INTERIOR WALLS THROUGHOUT HALLWAY SHOULD VARY BETWEEN 10'-0" AND 11'-0". REFER TO FLOOR PLANFOR FINAL LOCATIONS. DRYWALL TO BE FINISHED OUT AND TOPPED OFF WITH U CHANNEL OR PROVIDED EQUAL, AT TOP TO PROVIDE SMOOTH & STRAIGHT FINISH. UNLESS NOTED OTHERWISE OR AS DETERMINED IN BASE BUILDING DOCUMENTS.

SUSPENDED ACOUSTICAL CEILING SYSTEM, TYP.

SUSPENDED ACOUSTICAL CEILING SYSTEM, TYP.

HOLD GYP. BD. 3/8" OFF SLAB - SEAL GAP WITH BACKER ROD & CAULK, TYP. BOTH SIDES

CONTRACTOR'S OPTION: STABILIZE WALL w/ KICKERS OR w/ STUDS EXTENDED TO DECK @ 4'-0" O.C., MAX. .

SALONS BY JC 661 MT. JULIET ROAD, MT. JULIET, TN CONTRACT DOCUMENTS

Single Pole Light Switch

LRC SOLUTIONS,LLC

Recessed Fluorescent Eyeball Downlight

light fixture schedule

PLAN VIEW

ELEVATION TAG: ELEVATION REFERENCE SHEET REFERENCE

1

X'-X" AC-1

CEILING HEIGHT TAG: Ceiling Height Reference Ceiling Type Reference

key notes reflected ceiling plan

RCP plan general notes

RCP plan general notes

18"

KEYNOTE

NAME #

plan symbols RCP plan

PLAN VIEW

ROOM NAME & NUMBER

plan symbols RCP plan

29'-0"

plan symbols RCP plan

HOLD GYP. BD. 3/8" OFF SLAB - SEAL GAP WITH BACKER ROD & CAULK, TYP. BOTH SIDES

PARTITION CONSTRUCTION: 3-5/8" METAL STUDS (25 GA. MIN.) @ 16" O.C. MAX., w/ ONE LAYER OF 5/8" GYP. BD EA. SIDE; TERMINATING 6" ABOVE CEILING

SPECIFIED BASE, TYP. - SEE FINISH PLAN SPECIFIED FLOORING, TYP. - SEE FINISH PLAN

STUD WALL TO 6" ABOVE CEILING 9'-6" NON-RATED PARTITION ACOUSTICAL

reflected ceiling plan: 1/8" = 1'-0":

8'

4'

0

8'

REFLECTED CEILING PLAN

SALONS BY JC

661 S. MT. JULIET ROAD, MT. JULIET ,TN

A2.1