600 SERIES 611 621 631 641 651 661

• Dual vane semi-open ductile iron impeller • Class 30 epoxy-coated cast iron construction • Finned motor housing for superior heat dissipation • All units are double seal for extra motor protection 1.0 HP 1.5 HP 2.0 HP 3.0 HP 5.0 HP 7.5 HP • Corrosion resistant powder coated epoxy finish (For Pump Prefix Identification see News & Views 0052) • Stainless steel screws, washers, tag and seal assembly • 25 foot UL Listed power cord. Extra cord lengths available in 35 and 50 feet • Single phase - 230V capacitor start, capacitor run SUBMERSIBLE • Three Phase - 200-230-460-575 Volt SEWAGE OR DEWATERING NON-CLOG PUMP • Motor - 60 Hz, 1750 RPM, hermetically sealed and oil-filled for added heat dissipation • Continuous duty operation in submerged conditions • Maximum temperature for sewage or dewatering 104°F (40°C) with 1.2 service factor (1.0 service factor on Model 661) • 416 stainless steel motor shaft • Tandem shaft seals - stainless steel fitted, carbon/ceramic seal faces • Oversized upper & lower ball bearings running in an oil bath • Buna-N square ring seals • All models pass 2½" spherical solids • Specify 3" NPT vertical, 3" horizontal flanged or 4" horizontal flanged discharge • 100% computerized tested • Major width 17 9/16". Height 29 ¼" 3" Vertical Discharge • Rail systems available for all models • Control panels with overload protection available

“SEWAGE-WASTE” R

3" & 4" Horizontal Discharge

MODELS AVAILABLE

• Nonautomatic (For variable level control systems) • Double seal only • 3" Vertical, 3" Horizontal or 4" Horizontal flanged discharge • 230V/1 Phase or 200/230/460/575V/3 Phase

Manufacturers of . . .

© Copyright 2012 Zoeller Co. All rights reserved.

1

013859

Standard all models - 25 ft. cord - 1.0 HP 611 Models *E611 J611 F611 G611 BA611

Standard all models - 25 ft. cord - 3.0 HP

Volts Phase Mode Amps 230 1 Nonauto 6.9 200 3 Nonauto 4.3 230 3 Nonauto 3.7 460 3 Nonauto 1.9 575 3 Nonauto 1.6

641 Models *E641 J641 F641 G641 BA641

Volts Phase Mode Amps 230 1 Nonauto 8.9 200 3 Nonauto 5.9 230 3 Nonauto 5.1 460 3 Nonauto 2.6 575 3 Nonauto 2.0

651 Models *E651 J651 F651 G651 BA651

Mode Nonauto Nonauto Nonauto Nonauto Nonauto

Amps 17.0 11.0 9.6 4.8 3.9

Volts Phase Mode Amps 230 1 Nonauto 28.0 200 3 Nonauto 17.5 230 3 Nonauto 15.2 460 3 Nonauto 7.6 575 3 Nonauto 6.1

Standard all models - 25 ft. cord - 7.5 HP

Standard all models - 25 ft. cord - 2.0 HP 631 Models *E631 J631 F631 G631 BA631

Phase 1 3 3 3 3

Standard all models - 25 ft. cord - 5.0 HP

Standard all models - 25 ft. cord - 1.5 HP 621 Models *E621 J621 F621 G621 BA621

Volts 230 200 230 460 575

661 Models J661 F661 G661 BA661

Volts Phase Mode Amps 230 1 Nonauto 14.5 200 3 Nonauto 7.8 230 3 Nonauto 6.8 460 3 Nonauto 3.4 575 3 Nonauto 2.7

Volts Phase 200 3 230 3 460 3 575 3

Mode Amps Nonauto 25.3 Nonauto 22.0 Nonauto 11.0 Nonauto 9.0

*All single phase units require external starting capacity and relay circuits.

For information on additional Zoeller products refer to catalog on Variable Control Switches, FM0526; Piggyback Variable Level Float Switches, FM0477; Electrical Alternator, FM0486; Mechanical Alternator, FM0495; Sump/Sewage Basins, FM0487; Alarm System, FM0732; Simplex Controls, FM1596; Rail Systems, FM0787; and Junction Boxes FM1597.

All installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be followed including the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).

RESERVE POWERED DESIGN

For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump. © Copyright 2012 Zoeller Co. All rights reserved.

2

3" Vertical Discharge Weight 245 lbs.

3" Flanged Discharge Weight 245 lbs. BASIN SIMPLEX DUPLEX

DIAMETER 24 INCH MINIMUM 30 INCH MINIMUM

BASIN SIMPLEX DUPLEX

FOR SIZE ONLY. VOLUME MAY REQUIRE LARGER BASIN.

DIAMETER 30 INCH MINIMUM 36 INCH MINIMUM

FOR SIZE ONLY. VOLUME MAY REQUIRE LARGER BASIN. 6 5/16

6 5/16

I

O

T

N

I

O

N

3"-8 NPT

R O

T R O

T

A

T

A

9 1/8

9 5/8 17 9/16

SIMPLEX INSTALLATION

15 15/16

ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

15 1/8

SIMPLEX INSTALLATION ALL DIMENSIONS IN INCHES UNLESS OTHERWISE NOTED FLA 20

DIAMETER .68 .96

FLA 20

DIAMETER .68 .96

3 INCH UNICHECK P/N 30-0160

3 INCH NIPPLE (BY OTHERS)

3 INCH CHECK VAVLE P/N 30-0160

WEEP HOLE

3 INCH-8 NPT FLANGE (BY OTHERS)

29 1/4

29 1/4

10 3/4 5 1/4 8 5/16 5 1/4

2 5/8

STANDARD 3 INCH 90°

2 5/8

FLANGED ELBOW (BY OTHERS)

ZEPA0467A

ZEPA0470A

4" Horizontal Discharge Weight 245 lbs.

FLA 20

BASIN SIMPLEX DUPLEX

DIAMETER .68 .96

DIAMETER 30 INCH MINIMUM 48 INCH MINIMUM

FOR SIZE ONLY. VOLUME MAY REQUIRE LARGER BASIN.

4 INCH CHECK VALVE

6 5/16

T

I

O

N

29 1/4 R O

T

A

11 3/4 11 STD. 4 INCH-90° ELBOW P/N 6030-0194

5 1/4

17 5/16

2 5/8

17 5/8

SIMPLEX INSTALLATION

ZEPA0468A

© Copyright 2012 Zoeller Co. All rights reserved.

3

RAIL SYSTEM DIMENSIONAL DATA 3" Horizontal 39-0094

3" Vertical 39-0074 & 39-0075 BASIN DIAMETER SIMPLEX 36 INCH MINIMUM DUPLEX 42 INCH MINIMUM FOR SIZE ONLY. VOLUME MAY REQUIRE LARGER BASIN.

42 INCH DIAMETER MINIMUM FOR SIZE ONLY. VOLUME MAY REQUIRE LARGER BASIN.

DOOR FRAME REF. PLANE

6 5/16 22 5/8

6 5/16

N TI O

25 1/4

R O

T

A

N TI O

ROTA

9 5/8

ROTA

15 15/16 15 7/16 17 13/16

DOOR FRAME REF. PLANE

25 3/4

48 INCH DIAMETER MINIMUM FOR SIZE ONLY. VOLUME MAY REQUIRE LARGER BASIN.

SIMPLEX INSTALLATION

SIMPLEX INSTALLATION

DUPLEX INSTALLATION DIMENSIONS BASED ON STD. ANSI FITTING SIZES CHECK VALVES REQUIRED, NOT SHOWN FOR CLARITY ALL DIMENSIONS IN INCHES UNLESS OTHERWISE NOTED

TWO 3/8 HOLES

LIFTING CABLE S.S. OR GALV. STL. (OPTIONAL) CABLE CONNECTOR S.S. OR GALV. STL. (OPTIONAL)

3/4 INCH S.S. OR GALV. STL. PIPE (BY OTHERS)

CABLE CONNECTOR S.S. OR GALV. STL. (OPTIONAL)

3 2 INCH S.S OR GALV. STL. PIPE (BY OTHERS)

ø.48 (OPTIONAL)

9 5/8 FLA DIAMETER 20 .96

LIFTING HEIGHT = 40 7/16 (WITHOUT CABLE CONNECTOR)

3 INCH NIPPLE (BY OTHERS) WEEP HOLE 3 INCH COUPLING (BY OTHERS) 30 11/16 3 INCH MALE NPT

3 INCH NIPPLE (BY OTHERS) WEEP HOLE

32

2 1/2 - 3 INCH HOR. RAIL SYSTEM 5/8

5 3/8

6 11/16

3/8

FLA DIAMETER 20

3 INCH UNICHECK P/N 30-0160 LIFTING HEIGHT = 44 7/16 (WITH CABLE CONNECTOR)

3 INCH UNICHECK P/N 6030-0160

LIFTING CABLE S.S. OR GALV. STL. (OPTIONAL)

3 3/8

TWO 1/2 HOLES

LIFTING HEIGHT = 41 1/4 (WITHOUT CABLE CONNECTOR) LIFTING HEIGHT = 45 1/4 (WITH CABLE CONNECTOR)

3 1/4

8

14 1/8

4 1/16

30 1/8

ZEPA0472A

ZEPA0533A

4" Horizontal 39-0016

BASIN SIMPLEX DUPLEX 24 3/4

T

I

O

N

17 1/8

DIAMETER 36 INCH MINIMUM 60 INCH MINIMUM

FOR SIZE ONLY. VOLUME MAY REQUIRE LARGER BASIN.

R O

T

A

12 5/8 20 DOOR FRAME REF. PLANE

SIMPLEX INSTALLATION LIFTING CABLE S.S. OR GALV. STL. (OPTIONAL)

5 1/16 ø.1/2 - 2 HOLES

5 7

4 INCH CHECK VALVE

4 INCH-125 LB ANSI FLANGE

30 1/2 13 5/64

3/4

12

LIFTING HEIGHT = 44 1/4 (WITH CABLE CONNECTOR)

2 1

2" GUIDE RAIL (BY OTHERS)

CABLE CONNECTOR S.S. OR GALV. STL. (OPTIONAL)

LIFTING HEIGHT = 40 1/4 (WITHOUT CABLE CONNECTOR)

1 1/2

27 1/8

N TI O

T

I

O

N

ROTA

9 1/8

DOOR FRAME REF. PLANE

14 1/2

FLA 20

DIAMETER .68 .96

6 1/2

1 5/64

3 7/8

30 3/8

ZEPA0469A

© Copyright 2012 Zoeller Co. All rights reserved.

4

Recommend Documents