smart battery combiner (me-sbc) - Magnum Dimensions

Report 2 Downloads 44 Views
SMART BATTERY COMBINER (ME-SBC)

Model Number

yy ME-SBC

Available For

yy Renewable Energy Systems Off-grid Power Back-up Power yy Marine Systems yy RV Systems

Works With

yy DC Load Disconnect yy ME Series yy MS Series

The ME-SBC also works as a stand-alone unit.

The Sensata Technologies Smart Battery Combiner (ME-SBC) is an easy-to-use stand alone battery combiner and isolator for 12 and 24 VDC systems. Apply a single charging source to the main battery bank and the ME-SBC charges a second battery bank using a portion of the current. With adjustable voltage ranges, including automatic on/off setpoints, the ME-SBC prevents under- or over-charging.

THE FRONT PANEL INCLUDES: yyLED indicators showing status and operation. yyThree adjustable voltage dials to set the “Connect Voltage”, “Low V Disconnect”, and “High V Disconnect.” yyAn oversized power terminal block allowing for easy wire connections even if the wires are large.

FEATURES: yyVoltage auto-detect feature recognizing 12 or 24 VDC. yyTransfers up to 25 amps. yySolenoid drive for requirements greater than 25 amps. yyOver-temperature and over-current shutdown. yyAdjustable voltage settings with a wide range allows for charging flexibility.

yyAn accessories terminal block to add a solenoid or a separate voltage sense line.

yyBi-directional charging.

yyA reset switch.

yySense lead for long-run applications.

yyReverse polarity protection.

ME-SBC BASIC CONFIGURATION DIAGRAMS 25 AMP COMBINER MODE

SOLENOID DRIVE INVERTER/CHARGER

PWR

PWR

FAULT

FAULT SELECT

CHG

INV

ON/OFF

ON/OFF

CHARGER

CHARGER

ON/OFF

ON/OFF SHORE

INVERTER

AGS

METER

SETUP

TECH

ME-SBC STATUS

5

6

+



.4

.6 .8

(-)

(-)

D

ID O

SE

N

U

4

5

SE

T

LE

3

N

2

O

N

1

SE

(+ ) S

S

EG

N

PO

PO

(+ )

SMART BATTERY COMBINER

M

RESET

6

+



MAIN BATTERY BANK

AUXILIARY BATTERY BANK

REVERSE POLARITY

IN

+



.2

.3 14.0

SO

D

ID

4

(+ )

O

SE

N

U

SE

T

LE

N

3

N

SO

O

O C

2

U

M

1

SE

(+ )

(-)

(+ )

S

S

MAIN BATTERY BANK

EG

PO

PO X

IN

+

A

A



N

RESET

(-)

SMART BATTERY COMBINER

M

CLASS T FUSE

TECH

DISCONNECTED

SOLENOID (OPTIONAL)

X

REVERSE POLARITY

SETUP

13.5 15.0 LOW V HIGH V DISCONNECT

O

DISCONNECTED

U

13.5 15.0 LOW V HIGH V DISCONNECT

13.8 CONNECT VOLTAGE

STATUS

.8

13.1

.6 12.5

13.8 CONNECT VOLTAGE

C

.3 14.0

.9

.7

.4

12.8

.6

M A

.6 12.5

12.8

.2

13

.2

13.1

A

.7

.4

METER

MULTIPLY VOLTAGE SETTINGS x2 FOR 24V

.4

CLASS T FUSE

13

AGS

REMOTE ME-SBC

MULTIPLY VOLTAGE SETTINGS x2 FOR 24V

.9

SHORE

INVERTER

REMOTE

.2

SELECT

CHG

INV

(+ )

INVERTER/CHARGER

AUXILIARY BATTERY BANK

NEGATIVE BUS-BAR

NEGATIVE BUS-BAR

ME-SBC SPECIFICATIONS

REMOTE VOLTAGE SENSE INVERTER/CHARGER

PWR FAULT

ME-SBC

SELECT

CHG INV ON/OFF

CHARGER ON/OFF SHORE

INVERTER

AGS

METER

SETUP

TECH

INVERTER SPECIFICATIONS

REMOTE ME-SBC MULTIPLY VOLTAGE SETTINGS x2 FOR 24V

.2

13

13.1

.6 12.5

.2

.3 14.0

.4

.6 .8

13.5 15.0 LOW V HIGH V DISCONNECT

13.8 CONNECT VOLTAGE

STATUS

.9

.7

.4

12.8

DISCONNECTED REVERSE POLARITY

5

(+

)

(-) D

ID O

SE

N

U

4

6

+



12 or 24 VDC nominal

DC amps

25 amps continuous

Maximum VDC

40 volts peak

Average operating tare loss

~150 mW

Maximum operating tare loss

< 220 mW

Non-operating tare loss

< 50 mW

Operating range

0 - 32 VDC

Shipping weight

2 lbs (0.9 kg)

Shipping dimensions (l x w x h)

6” x 9” x 2.5” (15.2 x 22.9 x 6.4 cm)

Unit dimensions (l x w x h)

4.2” x 5.4” x 1.4” (10.7 x 13.7 x 3.6 cm)

Maximum operating temperature

-40° F to +185° F (-40° C to + 85° C)

Maximum storage temperature

-40° F to +194° F (-40° C to + 90° C)

SE

T

LE

N

3

N

SO

O

N M

O C

2

U

M

1

SE

(-)

)

EG

(+ S

S PO

PO

MAIN BATTERY BANK

X

IN

+

A

A



SMART BATTERY COMBINER )

RESET

(+

CLASS T FUSE

DC volts

AUXILIARY BATTERY BANK

NEGATIVE BUS-BAR

OFFICES 2211 West Casino Road Everett, Washington 98204 USA 425-353-8833 4467 White Bear Pkwy St. Paul, MN 55110 USA

The World Depends on Sensors and Controls

800-553-6418

T esting for specifications at 25° C. Specifications subject to change without notice.

www.SensataPower.com

February 2017

Rev C

Part #64-0600