SPS2GFSVA432 E60-34 REV B

Report 6 Downloads 255 Views
Specplus SPS2GFSVA432 2' x 4' Recessed Fluorescent, Lens Frame Troffer Static, 4 Lamp T8 or T5

Page 1 of 2

Features • • • • • • • • • • • • • • • •

5" deep body. 3-1/16" lamp to lens for better lamp obscuration. 81.2% efficient. Clean contoured interior. One-piece housing has ribbed construction for added strength. Hemmed over side rails for maximum safety. Fixture ends turned-in for safe handling. Built-in earthquake clips. Slimline door frame with 1000 square inch lens opening. Door jamb finished black on four sides for positive light stop. True mitered corner steel lens frame. Spring loaded rooster head latches. 18 gauge steel hinges. Flat and regressed aluminum doors available. Sky lens options avalible. Construction to meet NYC Code or Chicago Plenum requirements is available.

Mounting Methods G

Standard VA Lens

Optional Sky Lens

Dimensions

exposed T-grid ceiling. (with flat aluminum frame)

F

plaster ceiling/flanged. (with regressed aluminum frame)

5" (127mm) Plaster Opening 24-1/8"

1/4" max.

1-1/8" min. 3-3/4" max.

1-1/2" max.

15/16" or 1"

24"

6" (152mm)

2" x 2-1/2" access plate with two K.O.s (7/8" dia.)

exposed T-grid ceiling (with flat steel frame)

drywall kit (see options)

Type “G” FIxture

13/16"

24-11/16"

24" (610mm)

Support (by others) Drywall Kit (See Options) Drywall (by others)

Order Catalog Number: FK92X4.

1/4" max. 1-1/2" max.

24"

15/16" or 1" 39-1/4" (997mm) 47-31/32" (1218mm)

Job Information Type: Job Name:

earthquake clip before installation

earthquake clip installed (lay-in grid)

Cat. No.:

Lamp(s):

Volts/Ballast:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 02/10 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © Philips Group Section 1A/Folio E60-34 Rev. B

Specplus SPS2GFSVA432 2' x 4' Recessed Fluorescent, Lens Frame Troffer Static, 4 Lamp T8 or T5

Page 2 of 2

Photometry

Sky Lens Options

Model No. SPS2GFSVA43212004 LER = FP - 73.2 IW - 108.7 BF - 0.86 Comparative yearly lighting energy cost per 1000 lumens = $3.28 Report Number: ITL49786 Catalog Number: SPS2GFSVA43212004 Lamps: (4) F32T8 Luminaire: 2' x 4' SpecPlus with regressed aluminum door frame and extruded virgin acrylic shielding .095" nominal thickness (similar to pattern 12). Ballast: E423PI120G11 Report is based on 2850 Lumens per lamp. Efficiency: 81.2% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.000 21.875

70 89 82 75 69 64 59 55 51 48 45

80 50 85 75 67 60 54 49 44 40 37 34

30 82 70 61 53 47 42 37 34 31 28

50 80 71 63 57 51 46 42 39 36 33

50 30 78 67 58 51 45 41 36 33 30 28

10 76 64 54 47 41 36 32 29 26 24

50 77 68 61 55 50 45 41 38 35 32

30 30 75 65 57 50 44 40 36 33 30 27

0.0

45.0

90.0

0

3690

3690

3690

FLUX

5

3673

3678

3685

350

15

3546

3580

3612

1012

25

3270

3353

3430

1545

35

2814

2948

3056

1839

45

2192

2316

2457

1784

55

1410

1515

1613

1349

65

770

765

853

790

75

440

335

390

420

85

178

152

139

168

90

0

0

0

S2

LUMINANCE DATA IN CANDELA/SQ. METER AVERAGE AVERAGE AVERAGE AVERAGE IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 4773. 5043. 5351. 55 3785. 4067. 4330. 65 2806. 2787. 3108. 75 2618. 2112. 2320. 85 3145. 2685. 2456.

COEFFICIENTS OF UTILIZATION – ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC RW 01 02 03 04 05 06 07 08 09 10

S1 CANDELA DISTRIBUTION

10 73 62 53 46 41 36 32 29 26 24

ZONAL LUMEN SUMMARY ZONE 00-030 00-040 00-060 00-090 90-180 00-180

LUMENS % LAMP 2906 25.5 4745 41.6 7878 69.1 9257 81.2 0000 0.0 9257 81.2

% FIXT 31.4 51.3 85.1 100.0 000.0 100.0

Ordering Information Explanation of Catalog Number. Example: SPS2GFSVA432UNVH4

Specplus: Recessed fluorescent troffer

S

2

Static

Fixture Width

4 Ceiling Type: G= Grid (lay-in T bar) F= Flanged (over lap) Z spline and plaster frame

SP

Standard Specplus Plus

SX

For NYC Code – Local 3 Manufactured

Lens Frame: FS = Flat steel frame. RA= Regressed aluminum frame. FA = Flat aluminum frame.

Lens Shielding Type: VA=Virgin acrylic (standard) S1=Sky lens 1 S2=Sky lens 2 See options and consult factory

Lamp Quantity

Lamp Type/ Fixture Length: 32=32W T8 28=28W T5 54=54W T5 (Nominal 48")

Options/Accessories Special Lenses: Substitute VY for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average weight per square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz. average weight per square foot. Substitute S1 or S2 for VA (standard) = Sky Acrylic Lens (see Sky Lens sell sheet for further details). Plaster Frame: Catalog Number: PF24. Continuous Row Installation: For F type fixtures, half width flanges are required between fixtures. Order Catalog Number: 2FC TRIM CSP (each joint). Radio Interference Filter: To order one RIF per fixture; SUFFIX: R. To order one RIF per ballast; SUFFIX: B. Fusing: Internal fast-blow fusing. SUFFIX A. Internal slow-blow fusing. SUFFIX C. Electrical Wiring Options: Consult factory. Drywall Kit: Order Catalog Number: FK92X4. (Request Folio OA30-10 Rev. A). Chicago Plenum: SUFFIX: C.

Specifications Performance: In an installation of 4 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .85. To prevent glare the VCP shall be not less than 43 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 3108 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 68.6%.

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 02/10 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © Philips Group Section 1A/Folio E60-34 Rev. B

Voltage: 120, 277 or UNV=120-277

Options: Add appropriate suffix to catalog no., ie: (A)

Ballast Type: < 20THD < 10THD 2-2 Lamp Elec. T8 SO * HI * 1-4 Lamp Elec. T8 O4 * H4 * 2-2 Lamp 28W Elec. T5 – PI † 2-2 Lamp 28W Elec. T5 – †PG †† 1-4 Lamp 54W Elec. T5 – †PV †† LOL T8 Dimming PS – Other dimming options. Consult factory. †*Instant Start Standard ††Instant Start (120, 277 or UNV) ††Program Rapid Start (UNV only) NOTE: For T8 UNV, you must use HI, H4 Ballast Code.

Specifications (continued) Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing with side rails hemmed over and housing ends turned-in for safe handling. Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Lenses: VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge, .095" nominal thickness (similar to pattern 12). VY (optional) .125" nominal pattern 12 with 7.8 oz. average weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. average weight per square foot. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W. UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Job Information

Type: