TECH SHEET - DO NOT DISCARD PAGE 1 FOR SERVICE ...

Report 20 Downloads 63 Views
TECH SHEET - DO NOT DISCARD

PAGE 1

MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U. S. PATENTS:

OTHER PATENTS PENDING.

L1

N

BK

P1-1

LOWER OVEN TEMP SENSOR

TAN

P7 OVEN LIGHT

OVEN CONTROL BK

P8-1

TAN

W

P8-3

R

P8-5

BR

P4-5 P4-3

TAN

UPPER OVEN TEMP SENSOR

P2

Y

GY BR VLT OR BU

ON SOME MODELS

N.O. BU

GY Y

P4-4 P4-8 P3-3

P3-1

BK

Y

LF

DOOR LATCH SWITCH

DOOR SW.

Y

BROIL ELEMENT 3400 W BU/W

BU

OPENS @ 184°C

WARMING DRAWER ELEMENT - 850 W OR/BK

THERMAL FUSE R

W

W

ON SOME MODELS

BK

4

COM

Y

P3-2 OR/BK

OR/BK

W

M

BU

P4-1

VLT

R

1 2 3 4 5 X 7

P4-7 P4-6

BR

L2

GND

W

2 5 4 6 7 X 1

OR

WARMING DRAWER SENSOR

P1-4

POWER SUPPLY

BROWN WIRE CONTAINS NON-RESETABLE FUSE

W

4,467,184 4,565,967 4,613,739

3,877,460 4,102,322 4,364,589

3,659,578 3,788,300 3,832,988

NOTES: Schematic shows door latch switch in the cook position with the oven door open, and elements off.

P3-4

R

R BAKE ELEMENT 2400 W

W

P1

R L1

2 VLT

4A

S2 3

OR/WT

P

P2

H1

A

2A

P

LR

L2

P

RF

L1

L2

L1

P

RR

L2

CR

1

2

B

L1

L2

OR

2B

Y

H2 Y 2A

2B

H1 BR

1B

1200 W 1A

H2 BR 2A

2B

H1 BU

H2 BU 2A

2B

H1

H2

GY

GY

100W 1A INNER ELEMENT 1600 W

1B

1200 W 1A

1B

1800 W 1A

1B

2A

2B

1A

1B

ON SOME MODELS

BU OUTER ELEMENT 800 W BU

SURFACE IND. LIGHT

ACCUSIMMER IND. LIGHT

LF

LR

HOT SURFACE IND. LIGHTS

RF

RR

SURF IND. LIGHT

CR HOT SURFACE IND. LIGHT

ON SOME MODELS

FOR SERVICE TECHNICIAN'S USE ONLY

PART NO. 8522647 REV. A

PAGE 2

TECH SHEET - DO NOT DISCARD

DIAGNOSTICS

CAL is shown in 4-digit display (3 digits on right).

Disconnect power and perform the following checks:

n Pressing the TEMP pad “up” arrow (▲) adjusts the

n The most common cause for control failure is

n

n

n n

corrosion on connectors. Therefore, disconnecting and reconnecting wires will be necessary throughout test procedures. Check all connections before replacing components, looking for broken or loose wires, failed terminals, or wires not pressed into connectors far enough. All tests/checks should be made with a VOM or DVM having a sensitivity of 20,000 ohms per volt DC or greater. Voltage checks must be made with all connectors attached to the boards. Resistance checks must be made with power cord unplugged from outlet, and with wiring harness or connectors disconnected.

n

n

n

n

Temperature Adjustment

temperature in 10°F increments in the following sequence: 0°; 10°; 20°; 30°; -30°; -20°; -10°; 0°; and so on. Press START/ENTER pad to activate the desired temperature adjustment. If the START/ENTER pad is not pressed within 5 minutes, adjustment is ignored. BAKE temperature adjustment cannot result in operating temperatures higher than 525°F or lower than 170°F, as measured at oven cavity center. Once the BAKE temperature has been adjusted, BROIL temperatures are automatically offset to the same degree. CLEAN temperature is also offset automatically when BAKE temperature is adjusted. If BAKE temperature has been raised, CLEAN temperature is offset +5°F. If BAKE temperature has been lowered, CLEAN temperature is offset -5°F.

n Press and hold BAKE pad for five (5) seconds. Current

offset, if any, is shown in 3-digit display.

FAILURE/ERROR DISPLAY CODES 4-DIGIT DISPLAY

3-DIGIT DISPLAY

F0

E0

Factory default - not an error.

E0

EEPROM communications error

E1

EEPROM checksum error

E2

UL A/D error(s)

E4

Model ID error

E6

Latch signal mismatch error

E0

Shorted key

E1

Key tail unplugged

F1

F2

F3

F3

F5

LIKELY FAILURE CONDITION

E0

Oven sensor opened - Top

E1

Oven sensor shorted - Top

E2

Bake range over temperature

E3

Clean range over temperature

E4

Oven sensor opened - Bottom

E5

Oven sensor shorted - Bottom

E6

Warming drawer sensor open

E7

Warming drawer sensor shorted

E0

SUGGESTED CORRECTIVE ACTION PROCEDURE No action required. 1. Verify failure if not displayed, using CANCEL/OFF key. Press key for 5 seconds until last error code is displayed. 2. Disconnect power longer than 30 seconds. 3. Re-apply power and observe for longer than 1 minute. 4. If failure remains, disconnect power, replace control. 1. 2. 3. 4. 5.

Verify failure if not displayed, using CANCEL/OFF key. Press for 5 seconds. Disconnect power. If applicable, ensure membrane tail is seated in connector on back of control. Re-apply power and observe for longer than 1 minute. If failure remains, disconnect power, replace control.

1. Measure sensor value (between connector pins) between 1000 Ω @ 32° F and 2697 Ω @ 900° F (room temperature approx. = 1080 Ω). If measurement does not correlate to real temperature, disconnect power, replace sensor and refer to steps 3-5. Also measure from sensor connector to sensor casing for possible short. 2. Trace wires and connectors to sensor from control, then from sensor back to control. If all connections are made and no wire damage, refer to step 3. 3. Disconnect power longer than 30 seconds. 4. Re-apply power and observe for longer than 1 minute. 5. If failure remains, disconnect power, replace control, then go back to step 4. 1. Same corrective action as for other F3 codes, with the exception that the warming drawer resistance value at room temperature is approx. 100k Ω.

Door switches do not agree

1. Disconnect power from unit. 2. Check wires and connectors from control to door switch, then from door switch to control. 3. If no damage to wires or connector, replace door switch. 4. Re-apply power. 5. Press CANCEL PROGRAM and start the clean mode, and observe for one minute to ensure that operation is normal.

F5

E1

Door latch not operating

1. Verify error code by pressing and holding CANCEL/OFF key for 5 seconds. Momentarily (less than 5 sec.) press CANCEL key again to remove error code display. 2. Program and start the Clean mode. Observe to see if door locks. If it does not, inspect the locking mechanism from the solenoid to the latch pawl and door to find the cause of the problem. If the door is not locking, then 1 minute from the start of the Clean, the F5 E1 code will again be displayed. Press CANCEL key to remove error code display. 3. Once any mechanical problems with the latch mechanism have been corrected, program and start a Clean cycle (after, if necessary, clearing F5 E1 error code) to ensure proper operation of the door lock. Immediately cancel the Clean mode to observe proper operation of door unlock.

F8

E0

N/A

N/A

PART NO. 8522647 REV. A

FOR SERVICE TECHNICIAN'S USE ONLY

TECH SHEET - DO NOT DISCARD

PAGE 3

STRIP CIRCUITS

The following individual circuits are for use in diagnosis. Before starting diagnosis, check the line voltage and for blown fuses.

CLEAN N

OVEN CONTROL W

BR

M

L2

P8-5

THERMAL FUSE OPENS @ 184°C R BU-W

L1 BK

BROIL RELAY P3-1

P3-3

BAKE RELAY P3-4

P4-5

P4-4

DOOR LATCH SWITCH

BU

BU

GY

Y Y

DOOR SWITCH

BU

R

BROIL ELEMENT

BAKE ELEMENT

R

P4-3

Y

Y UPPER OVEN TEMP SENSOR

P4-1

V

TAN TAN

TAN

LOWER OVEN TEMP SENSOR

BR

BROIL

P4-8

P4-7

L1

L2

BK P3-1

BU

P3-3

BROIL ELEMENT

BU-W

THERMAL FUSE R OPENS @ 184°C

OVEN CONTROL

BAKE OVEN CONTROL

L1

L2

BK P3-1

P3-3

BU

N

THERMAL FUSE

BU-W

R

OPENS @ 184°C

BAKE ELEMENT

R

P3-4

OVEN LIGHT

BROIL ELEMENT

R

L1

OVEN LT.

BK

R

P8-3

W P4-4

Y

OVEN CONTROL Y

Y

Y

P8-1

GY

P4-3

DOOR SW.

FOR SERVICE TECHNICIAN'S USE ONLY

PART NO. 8522647 REV. A

PAGE 4

TECH SHEET - DO NOT DISCARD

STRIP CIRCUITS

The following individual circuits are for use in diagnosis. Before starting diagnosis, check the line voltage and for blown fuses.

CLOCK DISPLAY ON

N

W

P7

L1

GY BR VLT OR BU Y

2B

1B

SURFACE IND. LIGHT BU

W

A

2

1A

HOT SURFACE IND. LIGHT

LIMITER 2B

BU

1A

INNER ELEMENT

P1

L2

ACCUSIMMER SWITCH

LIMITER 4

2A

A

W

1

S2

L1

(DUAL)

HOT SURFACE IND. LIGHT

INFINITE SW. 4A

BU

OUTER ELEMENT

INFINITE SWITCH

LIMITER 1A

INNER ELEMENT

4

2A

A

OR

BU

Y

R

P3

GY

BU

BK

TAN

OR BK

1

P7

1

GY

QUICK DISCONNECT PLUGS (for Power Supply)

P2 P1

1

1

Y

GY

BK

PART NO. 8522647 REV. A

V

W

BR

OR

BU

2

P2

R

W

S2

P4

2

ACCUSIMMER NORM

SURFACE IND. LIGHT

QUICK DISCONNECT PLUGS (for Control)

R

L2

W

1B

P1

P2

N

2B

BK

2

2

ACCUSIMMER SWITCH

LIMITER

BK

INFINITE SWITCH

B

ACCUSIMMER IND. LIGHT

SURFACE UNIT

R

L2

H2

N

W

1B

INFINITE SW. BK

2A

SURFACE ELEMENT

SELECTOR SWITCH (OPTIONAL)

BK

INFINITE SW.

LIMITER H1

(ACCUSIMMER)

L2

HOT SURFACE IND. LIGHT

L1

L1

L1

P2

N

P

BK

BK

P1-1

W

INFINITE SW.

SURFACE UNIT

2 5 4 6 7 X 1

LIMITER

BK

(TYPICAL)

TRANSFORMER

P1-4

1 2 3 4 5 X 7

OVEN CONTROL

SURFACE UNIT

POWER SUPPLY

BROWN WIRE CONTAINS NON-RESETABLE FUSE

BR

BR

P8

V

V

OR

1

BU

R

BK

BR

Y

PART NO. 8522647 REV. A NOTE: This sheet contains important Technical Service Data FOR SERVICE TECHNICIAN ONLY DO NOT REMOVE OR DESTROY