TEL145 Series - Toto USA

Report 6 Downloads 62 Views
TEL145 Series

Axiom® EcoPower® Faucet FEATURES • Self-generating hydropowered EcoPower system • No minimum daily usage requirement • Micro-sensor positioned underneath the spout head for accurate hand detection ensuring smooth and consistent water distribution • Vandal resistant aerator housing • Durable chrome plated spout body • Single-hole mount • Kit includes spout body, controller box , and mounting hardware - less supply lines • 0.5 gpm aerated flow

MODELS

TEL145-D10E • TELS145 (Axiom Spout) • TELC105-D10E (Controller: 0.09gpc, 10 sec on-demand)



TEL145-D10EM • TEL145-D10E (Axiom Spout Kit) • TLM10 (Mixing Valve)



TEL145-D10ET • TEL145-D10E (Axiom Spout Kit) • TLT10R (Thermostatic Mixing Valve)



TEL145-C20E • TELS145 (Axiom Spout) • TELC105-C20E (Controller: 0.19gpc, 20 sec continuous)



TEL145-C20EM • TEL145-C20E (Axiom Spout Kit) • TLM10 (Mixing Valve)



TEL145-C20ET • TEL145-C20E (Axiom Spout Kit) • TLT10R (Thermostatic Mixing Valve)

COLORS/FINISHES • #CP Polished Chrome

OPTIONAL ACCESSORIES • THP3158#CP - 4" Cover Plate • THP3159#CP - 8" Cover Plate • TH559EDV566 - Laminar Flow Nozzle • THP3237 - Swivel Coupling

EcoPower

PRODUCT SPECIFICATION TOTO Model #______________ The faucet shall have hydropowered self-generating, EcoPower System. The faucet shall have maximum of 10 seconds on-demand flow (0.09gpc), or 20 seconds continuous flow (0.19gpc). Product shall have anti-scald shape memory alloy thermostatic mixing valve (-ET models only). The faucet shall have self-adjusting sensor.

CODES/STANDARDS • Operates below federally mandated consumption limit of 0.25gpc • Complies to California Green Building Code, CALGreen of 0.20 gpc • Meets or exceeds ASME A112.18.1M/CSA B125.1, and NSF372-2011 • Certifications: IAPMO(cUPC), State of Massachusetts, and others • California Green Code and City of Los Angeles Water Efficiency Ordinance • ADA compliant • Complies with federal and state statutes as low-lead (contains a weighted average of 0.25% lead or less) * For codes and standards of mixing valves TLM10 and TLT10R, please refer to corresponding product spec sheets. LOW-LEAD

STD

Helix

SPECIFICATIONS

3-15/16” (100mm)

EcoPower

Sensor L=43-5/16”Detection (L=1100mm) Range L=25-9/16” (L=650mm)

Water Supply Pressure

Helix-M TELS125 Water Supply TELS121 Inlet Temperature Range

7-11/16”

32-110°F(0-42°C)

(194mm) Water Saving On-Demand [10 sec.] faucet (0.09gpc) Federal Standard (0.25gpc) – 64% less CAL Green – 55% less 60° (0.20gpc) 7-5/16”

9-1/2” (238mm)

6-1/2” (165mm)

60°

Max. 90% RH

(186mm)

0.09 gpc* - max 10 second On-Demand** (0.09 gpc = 0.5 gpm x 10/60 sec) Equipped with 0.5 gpm flow control 4-15/16” (125mm)

Flow Rate Warranty

Continuous [20 sec.] faucet (0.19gpc) L=45-1/4” Federal (L=1150mm) Standard (0.25gpc) – 24% less Ø2-3/16” CAL Green (0.20gpc) – 5% less (Ø55mm)

2” (50mm) Max deck thickness

2” (50mm)



4-15/16”

(125mm) Following the federal mandate for water efficiency outlined in the Environmental Protection Act of 1992, L=41-5/16” 5-1/8" - 7-7/8" (130 - 200mm) (L=1050mm) faucets can be rated for water consumption based on Sensor is self-adjusting L=29-9/16” two categories: Rate Water Consumption. (L=750mm)FlowFaucet Min (Dynamic/Flowing) Pressure: Faucet hole Ø1-3/8” (Ø35mm)15psi holeand Ø1-3/8” (Ø35mm) TOTO uses the water consumption standard because (100kPa) Max (Static) Pressure: 80 psi (551kPa) Helix-Wall it is the most accurate method of measuring water TELS135 use. TOTO faucets also comply with the CALGreen G1/2 (1/2 NPSM compatible) TELS131 Guideline of water usage.

Ambient Temperature 32-104°F(0-40°C) Humidity

NOTE

Axiom® EcoPower® Faucet

Ø2-3/8” (Ø60mm)

Power Supply

2” (50mm)

2” (50mm) Max deck thickness

2” (50mm)

60° 3-3/4” (95mm)

2-15/16” (74mm)

30°

2” (50mm) Max deck thickness

4-1/2” (114mm)

TEL145 Series

6-3/4” (168mm)

TELS115 TELS111

TELS105 TELS101

0.19 gpc* - 20 second Continuous*** (0.19 gpc = 0.5 gpm x 20/60 sec) L=39-3/8” (L=1000mm)with 0.5 gpm aerated flow Equipped

L=31-1/2” (L=800mm)

L=26-3/4” (L=680mm)

Finished wall

Three yearsFaucet hole Ø1-3/8” (Ø35mm)

*Gallons per cycle (gpc) is the amount of water per usage cycle . Axiom Gooseneck ** On-demand refers to the way in which the water is dispersed (i.e.; water is only dispersed when the sensor is activated by the user as needed). TELS155 cycle. *** TELS145 Continuous means that water is dispersed for a continuous 20 second TELS151

Faucet hole Ø1-3/8” (Ø35mm)

Faucet hole Ø1-3/8” (Ø35mm) 3/8 COMPRESSION

G1/2 2-13/16” (71mm)

7/8” (23mm) Φ1-5/8”( Φ 42mm)

7” (178mm)

9-3/16” (231mm)

1-3/4” (44mm)

7” (178mm) 1-3/4”

3-13/16”(98mm) Faucet G1/2 hole Ø1-3/8” (Ø35mm)

Φ1-5/8”(Φ42mm)

G1/2 compatibel ½ NPSM G1/2with compatible

Hot/Cold Mixing Tee (TLM10)

(44mm)

1-11/16” (42mm)

2” (50mm) Max deck thickness

G1/2

3-5/16”(84mm) G1/2

38

5-13/16” (147mm)

1-11/16” (42mm)

L=37-3/8” (L=950mm)

1-7/16” (36mm)

Available Mixing Valves

5-3/4” (145mm)

5-5/8”(142mm)

G1/2 L=25-9/16” (L=650mm)

3-3/16”(82mm)

L=41-5/16” (L=1050mm)

2” (50mm)

G1/2

Faucet hole Ø1-3/8” (Ø35mm)

3-5/16”(83mm)

G1/2

5” 5” (126mm) (126mm)

3-5/8”(94mm)

4-5/8”(117mm)

G1/2

(50mm)

3-5/8”(94mm) 3-5/16”(83mm)

80°

1-9/16” 4-13/16” (40mm) (122mm) 1-9/16” Max deck thickness 4-13/16” 5-5/8”(142mm) (40mm) (122mm) Max deck thickness

4-1/2”

4-5/8”(117mm)

(114mm)

(74mm)

2-15/16”

(100mm)

L=23-5/8” (L=600mm)

2-1/2” (63mm)

Controller

Max deck thickness

3-3/4” (95mm) 3-15/16”

2” (50mm)

2” (50mm)

6-7/16” 6-7/16” (163mm) (163mm)

60°

3-3/4” (95mm)

(50mm)

1-1/16” (27mm)

1-1/16” (27mm)

1-1/16” (27mm) 1-1/16” (27mm)

3-3/16”(82mm)

TELS141

Axiom

with ½ NPSM

Thermostatic Mixing Valve (TLT10R) These dimensions and specifications are subject to change without notice

Ph: (888) 295-8134 | Fax: (800) 699-4889 | www.totousa.com | © TOTO USA

#SS-01086, v.09