MIDWEST ELECTRIC PRODUCTS, INC
TEMPORARY POWER Site-Power
™
® QUALITY WEATHERPROOF ELECTRICAL EQUIPMENT
TEMPORARY POWER The Midwest Way TM
Site-Power makes sense for you. Completely factoryassembled, factory-wired, and factory-tested. Site-Power TM comes to the construction job site ready for work. All you do is mount it, connect it, and it’s ready to use … over and over again. Site-PowerTM eliminates: • worries about safety • worries about theft • worries about vandalism • worries about weather • worries about durability • worries about code-violations TM
Just pick up Midwest’s Site-Power and you’re ready to go! Use it job, after job…
U039G
Figure Your Savings by Using Site-Power on Your Next Job: TM
MIDWEST
OR DO-IT-YOURSELF
ALL-IN-ONE DESIGN
• Fully assembled and prewired. • Includes breakers, receptacles and meter socket (if required).
• Available with GFI circuit breakers. • Eliminates construction hold-ups due to red tag code violations. Conforms to NEC and NEMA standards. Most models UL listed.
• Weatherproof, heavy steel construction holds up job after job.
• Dead front design provides maximum safety. • Locking cover guards against vandalism and unauthorized use.
METER SOCKET LOAD CENTER AND BREAKERS RECEPTACLES AND BOXES
$
FITTINGS AND WIRE LABOR CATALOG NUMBER
CATALOG NUMBER TOTAL COST
$
Data Subject To Change Without Notice
TOTAL COST
$
* See back page for details
TEMPORARY POWER Application Information Prior to permanent installation of the service equipment, a means of temporarily supplying power is required by the various construction trades. Many times, this requires several receptacles, overcurrent protection and possibly a meter socket and GFCI, all designed for outdoor installation. Historically, a temporary power set-up included an individual meter socket, a 4-8 circuit load center, several outlet boxes with receptacles and flip covers, all field nippled together on a 4x4 wood post. Of course, these “systems” did not provide maximum protection against weather and vandalism, plus, when subjected to normal field use, deteriorated rapidly. Site-PowerTM construction site equipment from Midwest Electric combines all the required components in a single enclosure. Completely factory-assembled and factory-tested, Site-PowerTM comes to the construction job site ready for work. No need to field assemble individual parts, saving installation time. Site-Power TM protects itself against weather, vandalism, and nuisance tripping. The single, heavy-gauge NEMA 3R rainproof enclosure is lockable and is engineered for maximum protection of receptacles, cords, plugs, breakers, and GFCI’s. Site-PowerTM fully meets the 2002 National Electrical Code and OSHA requirements.
Features and Benefits Rugged Durability • • • • •
All-in-one construction for factory assured terminations Rolled edge door for cord protection Continuous duty meter socket with meter guides and reinforced jaws – ringless and ring type. Utility accepted meter sealing accommodations Heavy G-90 zinc coated steel with highest quality electro-deposition finish resists corrosion and fading Welded flange NEMA 3R construction for lasting service in outdoor installations
User Safety • • •
Dead front construction prevents accidental contact with live parts Door has padlock provisions to prevent unauthorized access Listed by Underwriters Laboratories, a safety plus
Installation Ease • • • • • •
All components factory wired and assembled, reducing installation time Door removable for installation ease; stay-open position for user convenience All terminals accept copper or aluminum wire for added installation flexibility Wide range of receptacle configurations Broad range of concentric knock-outs to accommodate varied wiring needs All units with 12-2 CuAl equipment ground lug
* See back page for details
R011C010U
Data Subject To Change Without Notice
Featured Models** 20
U010C010
20 20
U010F
S P A C E
20
U011C010
20 20
S P A C E
R011C010U
UL MODEL NUMBER RECEPTACLES Y Y Y
U010C010 U010F U011C010
5-20R2GFI 5-20R2 (2) 5-20R2GFI
Y
U038C010
Y
U039G
6-20R, (2) 5-20R2GFI L6-30R, (2)L5-20R
Y
U054C
Y
U055C033
Y
U055G
Y
R011C010U+
(2) 5-20R2GFI
Y
M038CB1033
6-20R 5-20R2GFI
Y
R038C010U+
6-20R (2) 5-20R2GFI
Y
R055C033U+ ~
Y
R076C033+
14-50R 5-20R2GFI 14-50R (2) 5-20R2GFI
14-50R 5-20R2GFI 5-20R2
50
S P A C E
20 20
GFI
20
20
GF I
U055C033
S P A C E
50
GFI
20
50
U055G
50 20 20 GFI
S P A C E
S P A C E
M038CB1033
CIRCUIT PROTECTION CB120 FH2 (2) CB120, SPACE CB120 CB220 (2) CB120 GFI230, (2) GFI120, (6) SPACE CB120 CB250 SPACE CB120 GFI250 CB120 CB250 GFI120 (2) CB120 SPACE CB120 GFI220 (2) CB120 SPACE CB120 CB220 (2) CB120 SPACE CB120 GFI250 CB120 GFI250 (2) CB120 SPACE CB120
50
U054C
20 20 20
GFI
14-50R
S P A C E
U038C010
20
U039G
20 20
R038C010U
R055C033U
R076C033
WIRE CABINET HUB LOAD & UNIT STD. AMP VOLTS RANGE * SIZE OPENING NEUTRAL BAR WT. PKG. 20 120 B 6X9 Y —— 7 4 20 120 E 5X7 Y —— 4.5 4 70 120/240 P 6 X 14 Y LC33N 7 4 100 120/240
U
9 X 17
Y
LC55N1
15
1
200 120/240
U
14 X 21
Y
LC1212PC
28
1
70 120/240
O
6 X 14
Y
LC33N7
10
4
70 120/240
P
6 X 14
Y
LC33N7
10
4
70 120/240
P
6 X 14
Y
LC33N7
10
4
100 120/240
AA
9 X 30U
Y
LC33N1
21
1
100 120/240
AA
14 X 26
Y
LC55N1
33
1
100 120/240
AA
9 X 30U
Y
LC55N1
25
1
70 120/240
AA
9 X 30U
Y
LC33N1
23
1
90 120/240
AA
9 X 30
Y
LC55N1
24
1
* See reverse for further inf ormation. = Edis on Plug Fuse Base (Fuse s Not Included) + Also Availa ble in Ring Type. Repla ce R with M. ~ Florida Metering G roup (FMG) a pprov ed model av ailable . Orde r with “FMG” after m odel; Consult Manufa cturer
MEP F-TP 04
Data Subject To Change Without Notice
** Additional Basic And Custom Models Available, Consult Manufacturing Representative For Further Details
Technical Information REPLACEMENT METER CABINET SOCKET SIZE
MODEL NUMBER
CABINET DIMENSIONS HEIGHT WIDTH DEPTH A B C
ENCLOSURE STYLE
KNOCKOUT FIGURE
M011C010U
MSM100EZ
9 X 30U
B
30”
9-3/4”
5-3/16”
2
M038CB1033
MSM10014
14 X 26
B
26-1/4”
14-3/4”
4-9/16”
4
M038C010U
MSM100EZ
9 X 30U
C
30”
9-3/4”
5-3/16”
3
M055C033U
MSM100EZ
9 X 30U
C
30”
9-3/4”
5-3/16”
3
M076C033
MSM100930
9 X 30
B
30”
9-3/4”
5-3/16”
2
R011C010U
MSM100EZ
9 X 30U
B
30”
9-3/4”
5-3/16”
2
R038C010U
MSM100EZ
9 X 30U
C
30”
9-3/4”
5-3/16”
3
R055C033U
MSM100EZ
9 X 30U
C
30”
9-3/4”
5-3/16”
3
R076C033
MSM100930
9 X 30
B
30”
9-3/4”
5-3/16”
2
U010C010
——
6 X 14
A
14-3/8”
6-3/4”
5-3/16
1
U010F
——
5 X7
A
7-1/8"
5-3/4"
5-3/16"
5
U011C010
——
6 X 14
A
14-3/8"
6-3/4"
5-3/16"
1
U038C010
——
9 X 17
A
17-3/8"
9-3/4"
5-3/16"
2
U039G
——
14 X 21
A
21-3/8”
14-3/4”
5-3/16”
6
U054C
——
6 X 14
A
14-3/8"
6-3/4"
5-3/16"
1
U055C033
——
6 X 14
A
14-3/8"
6-3/4”
5-3/16"
1
U055G
——
6 X 14
A
14-3/8"
6-3/4”
5-3/16"
1
Wire Range Tables TABLE AA
TABLE P
TABLE O
Copper Aluminum Solid Strand Solid Strand
Connector
Copper Aluminum Solid Strand Solid Strand
Line
–––
6-1/0
–––
6-1/0
Line
14-8
14-2
12-8
12-2
Load
14-10
14-10
–––
–––
Load
–––
–––
–––
–––
Connector
Neutral
Large H ol e
Neutral
Smal l H ol e
Equip.Grnd.
12-8
12-1/0
10-8
10-1/0
Neutral
End H ole Si de H ole
14-8
14-4
12-8
12-4
Neutral
12-8
12-2
12-8
12-2
Equip.Grnd.
TABLE U
14-8
14-2
12-8
12-2
Aluminum
Aluminum
Solid
Strand Solid Strand
Line
14-8
14-1/0
12-8
12-1/0
Load
14-10
14-10
–––
–––
14-8
14-2
12-8
12-2
Neutral
E nd Hol e Side Hol e
14-8
14-4
12-8
12-4
12-8
12-2
12-8
12-2
14-8
14-4
12-8
12-4
Neutral
12-8
12-2
12-8
12-2
Equip.Grnd.
TABLE V Copper
Copper Connector
TABLE E Copper
Aluminum
Connector
Solid
Strand Solid Strand
Connector
Solid
Strand Solid
Strand
Line
14-8
14-1/0
12-8
12-1/0
Line
14-8
14-1/0
12-8
12-1/0
Load
14-10
14-10
–––
–––
Load
–––
–––
–––
–––
Copper
Aluminum
Connector
Solid
Strand
Solid
Strand
Line
14-10
14-10
–––
–––
Load
14-10
14-10
–––
–––
Neutral
Large H ole
12-8
12-1/0
10-8
10-1/0
Neutral
Large H ole
12-8
12-1/0
10-8
10-1/0
Neutral
Sm al l H ole
14-8
14-4
12-8
12-4
Neutral
Sm all H ole
14-8
14-4
12-8
12-4
Neutral
14-10
14-10
–––
–––
Equip.Grnd.
12-8
12-2
12-8
12-2
Equip.Grnd.
12-8
12-2
12-8
12-2
Equip.Grnd.
12-8
12-2
–––
–––
MEP F-TP0 4
Data Subject To Change Without Notice
Technical Information Cabinet Dimensions (FIG. A)
(FIG. B)
(FIG. C)
C
B
B
B
C
C
Knockout Configurations (FIG. 1)
(FIG. 2)
(FIG. 3)
A = 1/2" B = 1", 1-1/4", 1-1/2" C = 1-1/4", 1-1/2", 2", 2 1/2" G
G
G
G
N G
G
G
G G
(FIG. 4)
D G
D = 3/4", 1", 1-1/4"
G
B B
G W
(FIG. 5)
E = 3/4"
B
F = 1/2", 3/4" G = 1/2", 3/4", 1"
(FIG. 6)
H = 1/2”, 3/4", 1-1/4" N = 1/2", 3/4", 1", 1-1/4", 1-1/2" P = 1/2", 3/4", 1", 1-1/4", 1-1/2", 2", 2 1/2" W
C
W P
A P P
F
H F
C
C
C
A C E Q
C
Q = 1"
W = 1/2", 3/4", 1", 1-1/4", 2"
MIDWEST POWER OUTLETS Portable equipment requiring electricity continues to increase steadily in both number and variety. This creates the need for conveniently located receptacles to provide power for cord connected equipment. Midwest Electric Power Outlets provide one or more receptacles, with or without overcurrent protection, in a single enclosure eliminating the need for several separately mounted components while providing maximum protection against weather and normal field use. Additionally, many models are offered that also include disconnecting, metering, and/or pedestal mounting functions in a single NEMA 3R enclosure/assembly. Find out more in Midwest’s General Catalog, order brochure MEPF-PO04 from your local Manufacturer’s Representative, or download at http://www.midwestelectric.com/marketing Pictured on cover, left to right: U038C010, M011C010, M055C033. Contact local manufacterer’s representative for further information on these and other popular models.
Powers the Great Outdoors ©2004, Midwest Electric Products, Inc PO Box 910, Mankato, MN 56001 (507)345-2505, (507)345-2530 FAX ME PF-TP04
www.midwestelectric.com
[email protected] Data Subject To Change Without Notice