IMPLANT SPECIFICATIONS
10.5º
14 mm
Proximal Oblique
20 mm
Distal Oblique
36 mm 30 mm
57 mm
AP Dynamic Stat 2
7 mm
Stat 1
Start of bend is 75 mm
Titanium Cannulated Tibial Nails—EX
Radius varies
TITANIUM CANNULATED TIBIAL NAILS WITH RADIOLUCENT INSTRUMENTATION Expert Nailing System Suprapatellar technique
End of bend is half length of nail
ML
AP
37 mm 22 mm
Oblique
5 mm
ML
Synthes (USA) 1302 Wrights Lane East West Chester, PA 19380 Telephone: (610) 719-5000 To order: (800) 523-0322
13 mm
Synthes (Canada) Ltd. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 To order: (800) 668-1119 Fax: (905) 567-3185
www.depuysynthes.com
BACK TABLE CHART FOR OR PERSONNEL
© DePuy Synthes Trauma, a division of DOI 2013. All rights reserved. J11982-B 1/14
IMPLANT SPECIFICATIONS
10.5º
14 mm
Proximal Oblique
20 mm
Distal Oblique
36 mm 30 mm
57 mm
AP Dynamic Stat 2
7 mm
Stat 1
Start of bend is 75 mm
Titanium Cannulated Tibial Nails—EX
Radius varies
TITANIUM CANNULATED TIBIAL NAILS WITH RADIOLUCENT INSTRUMENTATION Expert Nailing System Suprapatellar technique
End of bend is half length of nail
ML
AP
37 mm 22 mm
Oblique
5 mm
ML
Synthes (USA) 1302 Wrights Lane East West Chester, PA 19380 Telephone: (610) 719-5000 To order: (800) 523-0322
13 mm
Synthes (Canada) Ltd. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 To order: (800) 668-1119 Fax: (905) 567-3185
www.depuysynthes.com
BACK TABLE CHART FOR OR PERSONNEL
© DePuy Synthes Trauma, a division of DOI 2013. All rights reserved. J11982-B 1/14
IMPLANT SPECIFICATIONS
TITANIUM CANNULATED TIBIAL NAILS WITH RADIOLUCENT INSTRUMENTATION—SUPRAPATELLAR TECHNIQUE Back table set-up of surgical instruments in order of use 1
2
6
7
8
9
10.5º
11
12
13
14
17
18
19
21
23
24
25
26
16
Titanium Cannulated Tibial Nails–EX Universal design for the left or right tibia Material Titanium-6% aluminum-7% niobium alloy
3
15
Proximal Oblique
14 mm 20 mm 36 mm
Distal Oblique
30 mm AP
Dynamic
5
10
Stat 1 Start of bend is 65 mm R 100
Colors • 8 mm and 9 mm (blue) use 4.0 mm titanium locking screws (blue) • 10 mm – 13 mm (green) use 5.0 mm titanium locking screws (green)
20
7 mm
Stat 2
Diameters 8 mm – 13 mm (1 mm increments) • 8 mm – 10 mm nails have a proximal diameter of 11 mm • 11 mm – 13 mm nails have a proximal diameter consistent with the shaft diameter
4
57 mm
Titanium Cannulated Tibial Nails—EX with Proximal Bend
Lengths 255 mm – 435 mm (15 mm increments)
22
Cross Section • 8 mm – 10 mm nails are round • 11 mm – 13 mm nails are fluted
1.
03.010.020 03.010.023
2.
3.
03.010.455 03.010.456 03.010.435 03.010.436
4.
03.010.430
5.
03.010.437S 03.010.438S
Radiographic Ruler for Titanium Cannulated Tibial Nails Radiographic Canal Width Estimator (not shown) 12.0 mm Trocar, PEEK, for Suprapatellar or 14.5 mm Trocar, PEEK, for Suprapatellar (not shown) 12.0 mm Protection Sleeve, straight, for 8 mm–11 mm nails or 14.5 mm Protection Sleeve, straight, for 12 mm–13 mm nails (not shown) Handle for Protection Sleeves, for Suprapatellar 12.0 mm Outer Protection Sleeve, for Suprapatellar, sterile or 14.5 mm Outer Protection Sleeve, for Suprapatellar, sterile (not shown)
6.
Wire Guide, 2 holes, 12.0 mm/3.2 mm or Wire Guide, 2 holes, 14.5 mm/3.2 mm (not shown) 7. 357.399 3.2 mm Guide Wire, 400 mm 8. 03.010.439 12.0 mm Cannulated Drill, long, with quick coupling 9. 03.010.404 Cannulated Connecting Screw 10. 03.010.440 Insertion Handle, for Suprapatellar 11. 03.010.093 Reaming Rod Push Rod Alternative Instrument (not shown): 03.010.092 Ball Hex Screwdriver, 8 mm 12. 13. 14. 15.
03.010.433 03.010.434
04.0X4.XXX 03.010.475 03.010.441 03.010.442
Titanium Cannulated Tibial Nails–EX, sterile Driving Cap Aiming Arm, for Suprapatellar 12.0 mm/8.0 mm Protection Sleeve with Flats, for Suprapatellar
16. 03.010.064 03.010.065 17. 03.010.069 03.010.070 18. 03.010.060
8.0 mm/3.2 mm Drill Sleeve or 8.0 mm/4.2 mm Drill Sleeve (not shown) 3.2 mm Trocar or 4.2 mm Trocar (not shown) 3.2 mm Three-Fluted Drill Bit, quick coupling, 330 mm, 100 mm calibration or 03.010.061 4.2 mm Three-Fluted Drill Bit, quick coupling, 330 mm, 100 mm calibration (not shown) 03.010.072 Depth Gauge for Locking Screws to 100 mm for IM Nails (not shown) 19. 03.010.472 Inter-Lock Screwdriver, SD25/3.5 mm Hex, 330 mm Alternative Instrument (not shown): 03.010.107 StarDrive Screwdriver, T25, self-retaining 20. 04.005.XXX 04.015.XXX
4.0 mm or 5.0 mm Locking Screws or 5.0 mm Dual Core Locking Screws
21. 03.010.445 SD40 StarDrive Screwdriver, long, inter-lock Alternative Instrument (not shown): 03.010.447 SD40 StarDrive Screwdriver, long, cannulated 22. 04.004.XXX 23. 03.010.103 03.010.104 24. 03.010.106 25. 03.010.112 26. 04.005.XXX
End Cap 3.2 mm Three-Fluted Drill Bit, quick coupling, needle point, 145 mm or 4.2 mm Three-Fluted Drill Bit, quick coupling, needle point, 145 mm (not shown) Direct Measuring Device for Locking Screws to 100 mm for IM Nails Holding Sleeve with Locking Device 4.0 mm or 5.0 mm Locking Screws
Start of 3º tip bend is 57 mm
ML AP
Oblique 5 mm
37 mm 22 mm
ML 13 mm
IMPLANT SPECIFICATIONS
10.5º
14 mm
Proximal Oblique
20 mm
Distal Oblique
36 mm 30 mm
57 mm
AP Dynamic Stat 2
7 mm
Stat 1
Start of bend is 75 mm
Titanium Cannulated Tibial Nails—EX
Radius varies
TITANIUM CANNULATED TIBIAL NAILS WITH RADIOLUCENT INSTRUMENTATION Expert Nailing System Suprapatellar technique
End of bend is half length of nail
ML
AP
37 mm 22 mm
Oblique
5 mm
ML
Synthes (USA) 1302 Wrights Lane East West Chester, PA 19380 Telephone: (610) 719-5000 To order: (800) 523-0322
13 mm
Synthes (Canada) Ltd. 2566 Meadowpine Boulevard Mississauga, Ontario L5N 6P9 Telephone: (905) 567-0440 To order: (800) 668-1119 Fax: (905) 567-3185
www.depuysynthes.com
BACK TABLE CHART FOR OR PERSONNEL
© DePuy Synthes Trauma, a division of DOI 2013. All rights reserved. J11982-B 1/14