TVL2000 II Photometric Testing Report Full ON (pdf) - Amazon Web ...

Report 1 Downloads 47 Views
REPORT

FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 17025:2005.

25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 Project No. G101589308

Date:April 2, 2014

REPORT NO. 101589308LAX-016 TEST OF ONE TVL 2000 II FULL ON

RENDERED TO ELATION PROFESSIONAL 6122 S. EASTERN AVE. COMMERCE, CA 90040

TEST:

Electrical and Photometric tests as required to the IESNA test standard.

STATEMENT OF LIMITATION:

This report must not be used by the client to claim product certification, approval, or endorsement by A2LA, NIST, or any agency of the federal government.

AUTHORIZATION:

The testing performed was authorized by signed quote number 500515440.

STANDARDS USED:

The following American National Standards or Illuminating Engineering Society of North America Test Guides were used in part or totally to test each specimen:

IESNA LM-79 - 2008: Electrical and Photometric Measurements of Solid State Lighting

DESCRIPTION OF SAMPLE:

The client submitted one production sample of TVL 2000 II FULL ON. The sample was received by Intertek on January 0, 1900, in undamaged condition and one sample was tested as received. The sample designation was LAN1403210902-016.

DATES OF TESTS:

March 25, 2014

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

SUMMARY Description:

TVL 2000 II FULL ON

Criteria Total Lumen Output (Lumens) Total Power (W) Luminaire Efficacy (LPW)

Sphere 3851 85.66 44.96

Criteria Power Factor Current ATHD % Correlated Color Temperature (CCT - K) Color Rendering Index (CRI - Ra) Color Rendering Index (CRI - R9) DUV Chromaticity Coordinate (x) Chromaticity Coordinate (y) Chromaticity Coordinate (u') Chromaticity Coordinate (v')

Result Goniometer 3762 85.44 44.03

Result 0.995 6.72 4727 95.5 73.0 0.006 0.352 0.346 0.218 0.483

EQUIPMENT LIST

Equipment Used LabSphere Power Supply LapSphere 3M Integrating Sphere LabSphere Spectrometer California Instruments Power Supply Yokogawa Power Meter Extech Instruments Stop Watch Omega Environmental Monitor LSI High Speed Mirror Goniometer Elgar Power Supply Yokogawa Power Analyzer Omega Environmental Monitor Extech Instruments Stop Watch Tape measure

Report No. 101589308LAX-016

Model Number LPS-100-0833 CA-11821-LRT CDS-3020 CSW5550 WT333 N/A N/A 6440T CW1251 WT210 N/A N/A N/A

2 of 8

Control Number 000832 000830 000834 001338 001319 001380 000886 000943 000944 000945 000882 001380 000684

Last Date Calibrated 05/23/13 VBU VBU N/A 05/10/13 04/22/13 09/10/13 03/24/14 VBU 11/14/13 09/09/13 04/22/13 12/09/13

Calibration Due Date 05/23/14 VBU VBU N/A 05/10/14 04/22/14 09/10/14 03/31/14 VBU 11/14/14 09/09/14 04/22/14 12/09/14

Date: April 2, 2014

TEST METHODS Seasoning in Sample Orientation – LED Products No seasoning was performed in accordance with IESNA LM-79.

Photometric and Electrical Measurements – Integrating Sphere Method A Labsphere CDS 3020 Spectrometer and Three Meter Sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Yokogawa Power Analyzer. The calibration of the sphere spectrometer system is traceable to the National Institute of Standards and Technology. Photometric and Electrical Measurements – Distribution Method A LSI Type C High Speed Model 6440 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Yokogawa Power Analyzer. Some graphics were created with Photometrics Plus software.

Report No. 101589308LAX-016

3 of 8

Date: April 2, 2014

RESULTS OF TEST Photometric and Electrical Measurements at Ambient Temperature (25°C +/- 1°C) - Integrating Sphere Met hod

Intertek Sample No. LAN1403210902-016

Correlated Color Temperature (K)

4727

CRI -Ra 95.5

Input Input Input Voltage Current Power {Vac} (mA) (Watts) 120.0 717.1 85.66

Base Orientation UP

CRI -R9 73.0

DUV 0.006

CIE 31’ Chromaticity Coordinate (x) 0.352

Input Current Power ATHD Factor (%) 0.995 6.72

CIE 31’ Chromaticity Coordinate (y) 0.346

Luminous Flux (Lumens) 3851

CIE 76’ Chromaticity Coordinate (u’) 0.218

Lumen Efficacy (LPW) 44.96

CIE 76’ Chromaticity Coordinate (v’) 0.483

Spectral Distribution over Visible Wavelengths nm 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435

mW/nm 0.002 -0.021 0.011 -0.051 -0.039 -0.052 -0.015 0.012 -0.020 0.007 0.038 0.096 0.276 0.843 2.168 4.676 8.636 14.880

nm 440 445 450 455 460 465 470 475 480 485 490 495 500 505 510 515 520 525

mW/nm 25.970 45.030 62.740 61.780 50.280 41.160 33.710 27.730 25.250 25.070 26.070 27.910 29.900 31.570 32.740 33.700 34.570 35.300

nm 530 535 540 545 550 555 560 565 570 575 580 585 590 595 600 605 610 615

mW/nm 36.250 37.130 38.040 38.800 39.250 39.460 39.350 38.990 38.440 37.700 37.040 36.450 35.970 35.910 36.490 37.530 38.780 40.200

nm 620 625 630 635 640 645 650 655 660 665 670 675 680 685 690 695 700 705

mW/nm 41.590 42.920 44.020 44.800 45.160 45.020 44.500 43.540 42.100 40.310 38.170 35.740 33.170 30.450 27.670 25.010 22.470 20.140

nm 710 715 720 725 730 735 740 745 750 755 760 765 770 775 780

mW/nm 17.900 15.870 14.020 12.310 10.710 9.269 8.005 6.885 5.918 5.105 4.419 3.785 3.242 2.767 2.362

Spectral Data Over Visible Wavelengths

70.000 60.000

(mW/nm)

50.000 40.000 30.000 20.000 10.000 0.000 350

400

450

500

550

600

650

700

750

800

Nanometers

Report No. 101589308LAX-016

4 of 8

Date: April 2, 2014

RESULTS OF TEST (cont'd) Photometric and Electrical Measurements at Ambient Temperature (25°C +/- 1°C) – Distribution Method

Intertek Sample No. LAN1403210902-016

Base Orientation UP

Input Input Input Voltage Current Power {Vac} (mA) (Watts) 85.44 120.0 715.9

Absolute Lumen Efficacy Input Power Luminous Flux (Lumens Per (Lumens) Watt) Factor 3762 0.994 44.03

Intensity (Candlepower) Summary at 25°C - Candelas Maximum Candela Value: 11164 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

0 11137 9726 6191 3585 2178 1484 1050 766 548 394 287 228 171 38 17 51 33 16 0

22.5 11164 9745 6290 3651 2230 1518 1076 775 568 390 285 224 165 123 62 77 52 47 6

45 11142 9799 6422 3727 2303 1570 1137 837 572 396 298 211 169 111 63 53 34 28 0

Report No. 101589308LAX-016

67.5 11139 9855 6587 3846 2363 1614 1165 838 602 415 302 237 178 104 74 52 37 27 0

90 11126 9902 6670 3940 2372 1601 1141 818 591 431 293 237 165 46 42 38 32 19 5

5 of 8

Date: April 2, 2014

RESULTS OF TEST (cont'd) Illumination Plots Mounting Height: 10 ft. Illuminance - Cone of Light

Isoillumination Plot

Zonal Lumens and Percentages at 25°C

Zonal Lumen Summary and Percentages at 25°C Zone Lumens 0-30 2564 0-40 3068 0-60 3582 60-90 179.5 0-90 3761 0.5 90-180 3762 0-180

Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100

% Luminaire 68.2 81.6 95.2 4.8 100.0 0.0 100.0

Report No. 101589308LAX-016

6 of 8

Lumens 803.9 1041 719.5 504.0 313.6 199.8 98.7 55.8 25.0 0.5

% Luminaire 21.4 27.7 19.1 13.4 8.3 5.3 2.6 1.5 0.7 0.0

Date: April 2, 2014

PICTURE (not to scale) X

CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report.

In Charge Of Tests:

Report Reviewed By:

Jesse Reyna Technician Lighting Division

Kenda Branch Engineer Lighting Division

Attachment: None

Report No. 101589308LAX-016

7 of 8

Date: April 2, 2014

Report No. 101589308LAX-016

8 of 8

Date: April 2, 2014