W8665A,E RF Receiver Module

Report 16 Downloads 155 Views
Honeywell

W8665A,E RF Receiver Module

APPLICATION The W8665A,E RF Receiver Module (RM) provides 24 Vac control of HVAC equipment when used with a T8665A Chronotherm® IV Wireless Programmable Thermostat. The W8665A can be used with 1H/1C

Table Model

Application

1. W8665

single-zone conventional applications. The W8665E can be used with up to three zones when used with a Honeywell EMM-3 Electronic MiniZone TM Panel, EMM-3U Universal Electronic MiniZone Panel, TZ-3 TotalZone® Control Panel or TZ-4 TotalZone® Zone Control Panel. See Table 1. TM

Description. Zones

Stages

Comments

W8665A

Conventional gas, oil or electric systems.

1H/1C

One

Use with T8665A Wireless Thermostat.

W8665E

Conventional gas, oil or electric systems.

1H/1C

Up to three

Use with T8665A Wireless Thermostats. Use with EMM-3 Electronic MiniZone TM Panel

Single or multi-stage conventional or heat pump systems.

Up to 2H/2C

Use with T8665A Wireless Thermostats. Use with EMM-3U Universal Electronic MiniZone Panel.

1H/1C orupto 3H/2C

Use with T8665A Wireless Thermostats. Use with TZ-3 TotalZone Zone Control Panel a or TZ-4 TotalZone® Zone Control Panel b.

TM

TM

aTZ-3 can work with up to 30 zones. Must use multiple W8665E Receiver Modules. bTZ-4 can work with up to 32 zones. Must use multiple W8665E Receiver Modules.

INSTALLATION

1.

CAUTION

2.

Equipment Damage Hazard. Do not mount W8665 inside HVAC equipment. Do not mount on metal surfaces. Mount only on wall.

¢_)U.S. Registered Copyright

Trademark

¢) 2003 Honeywe41 •

3. 4.

Mount the thermostats in each zone of the living space using the installation instructions provided with each thermostat. Mount the dampers in the ductwork using the installation instructions provided with each damper. Mount the W8665 RF Receiver Module near the HVAC equipment on a walt. See Fig. 1. Level the W8665 for appearance only.

/_ _

• All Rights Reserved

69-1d30-1

W8665A,E

RF RECEIVER

MODULE

Wiring the W8665E Connect the RF Receiver Module zones to the appropriate thermostat zone connections on the EMM-3 Electronic MiniZone Panel, EMM-3U Universal Electronic MiniZone Panel, TZ-3 TotaiZone TMZone Control Panel or TZ-4 TotalZone® Zone Control Panel. See Fig. 7 through 16 and Table 3. TM

TM

W8665

Table 3. W8665E Terminal

Designations.

M20162

Terminal Designation

Fig. 1. W8665 mounting location

24 Vac transformer hot. Powers RF receiver module.

C

24 Vac transformer common. Powers RF receiver module.

RZ

24 Vac system transformer. The three RZ terminals are internally connected. Connect RZ to Zone 1 R terminal on zone panel, as desired. (Not required.)

RZ

24 Vac system transformer. The three RZ terminals are internally connected. Connect RZ to Zone 2 R terminal on zone panel, as desired. (Not required.)

RZ

24 Vac system transformer. The three RZ terminals are internally connected. Connect RZ to Zone 3 R terminal on zone panel, as desired. (Not required.)

Zone 1 Y

Stage 1 cool.

Zone 1 W

Stage 1 heat.

Zone 1 G

Fan

Zone 2 Y

Stage 1 cool.

Zone 2 W

Stage 1 heat.

Zone 2 G

Fan

Zone 3 Y

Stage 1 cool.

Zone 3 W

Stage 1 heat.

Zone 3 G

Fan

WIRING All wiring must comply with local electric codes and ordinances. See Fig. 2 through 16 wiring diagrams for specific applications. Refer to Tables 2 and 3 for terminal designations.

CAUTION Voltage Hazard. Can cause electrical shock or equipment damage. Disconnect power before beginning installation.

Wiring the W8665A Connect the RF Receiver Module to the equipment loads. See Fig. 2 through 6 and Table 2.

Table 2. W8665A Terminal Designations. Terminal Designation R

Function 24 Vac transformer hot. Powers RF receiver module.

C

24 Vac transformer common. Powers RF receiver module.

RZ

24 Vac system transformer. Factory installed jumper between R and RZ terminals. Use RZ as a convenience terminal, as desired.

Y

Stage 1 cool.

W

Stage 1 heat.

G

Fan

69-1630-1

Function

R

2

W8665A,E

__J

COMM

RF RECEIVER

MODULE

ZON5

O

O

LED

LED

W8665A

L

LED STATES: COMM_ RAPIDLY FLASHING GREEN RECEIVING INFORMATION FROMTHERMOSTAT GREEN OFF STANgBY_ READY TO RECEIVE INFORMATION ZONE¸ RSDON SYSTEM (HEAT COOL OR FAN) ISON RED OFF SYSTEM (HEAT COOL OR FAN) ISOFF FLASHJNGRED ERROR NOTRECEIVINGSlGNALFROMTHERMOSTAT RAPIDLY FLASHING RED RECEIVER IN SET UP MODE

DIP SWITCH SETT_NaS: OFF_NOT SET UP TO RECEI\'E INFORMATION FROM A THERMOSTAT ON_READY TO RECEIVE INFORMATION FROMTHERMOSTAT AFTER SET UP IS COMPLETE

ZONE I

ZONE 2 ZONE S SET-UP: MOVE 91P SWITCH TO O_ POSITION AND MAKE THERMOSTAT CALL FOR FAN NOTE¸ ALL OTHER THERMOSTATS MUST BE OFF (NOT CALLING) DURING SET UP

.....

I

[_Z_

J

J LI L2 (HOT) t42016SC

Fig.

2. Connecting

CO_M J

the W8665A

RF Receiver

ZONE _

ZONE2

ZONES

O

O

O

O

LEg

LED

LED

LED

Module

to the

equipment.

WSG65E

h

LEDSTATES: RAPID_v FLASHINGGREEN RECEIVIf_GINFORMATONFROM THERfqOSTAT G_EEN OFF STANDBY, READYTO RECEIVE_NFORMATION ZONE REDON SYSTE_ _HEATCOOLOR FAN}ISON REDOFF SYSTEM(_EATCOOLORFANIISOFF FLASHINGRED ERROR NOTRECEIVINGSIGNALFROMTHERM©STAT AApIDJVFLAS INGRED RECEIVERIN SETUP MODE

DfPSW{TCHSETTINGS: OFRNOTSE_U_TO RECEIVEINFORf_ATION FRO_ATHERMOSTAT ONmEADYTORECE_VE_NFO_MATION FROMTHERMOSTA_ AFTER SE_UmSCOMPLETE

ZONE1

ZONE2 ZONES _E_UP: _OVEDI_ SWffC_TO O_ _OS_TIO_ANDf_A_ET_ERMOSTATCALLFOR_N NOTE_ALLOTHERT_ERMOSTA_Sf_UST BEOFF_NO_CALLI_GIDURINGSE_UP ZOnE I

Z_FACTORY

Fig. 3. Connecting

the

ZONE 2

ZONES ¥WG

R C RZ_RZ

INSTALLEDJUM_E_

W8665E

RF Receiver

LI (HOT_197S_

Module

3

to the

equipment

in a one-zone

application.

69-I630-1

W8665A,E

RF RECEIVER

MODULE

FW8665A

Q_

(_

"-'_

_

L2

_

L,NE',OLTAGE CIRC_JLATOR

L8124E,G,L

Fig.

4. Single

zone

hot

water

heat

using

an L8124E,

G, L Aquastat.

W8665A

R8222

© • (TV)



_FACTORYINSTALLEDJUMPER

CIRCULATOR INEVOLTAGE

[_ L8124A,B,C,M

Fig. 5. Single

69-1630-1

zone

hot

water

heat

using

an L8124A,B,C,M

or L8148

4

Aquastat,

an R8222

relay

and

a transformer.

W8665A,E

RF RECEIVER

MODULE

LsA _t

_'

_ .................................. tt_.,.

Q0CIRCULATOR UNEVOLTAGE L8124/L8148

Fig.

6. Single-zone

hot water

M20_83

heat

with

cooling

using an L8124 transformer.

5

or L8148

Aquastat,

an R8222

relay

and

a

69-I630-1

W8665A,E

RF RECEIVER

MODULE

F

i i::: i i:o:

THERMOSTAT

THERMOSTAT

COMM

ZONE /

ZONE 2

0

0

0

0

LED

LED

LED

LED

THERMOSTAT

ZONE 3

L

W8665E

LED STATES: COMM RAPIDLY FLASHING GREEN RECEIVING INFORMATION FROMTHERMOSTAT GREEN OFF STANDBY READY TO RECEIVE _NFORMATION ZONE RED ON SYSTEM (HEAT COOL OR FAN} IS ON RED OFF SYSTEM (HEAl COOL OR FAN} IS OFF FLASHING RED ERROR NOT RECEWING SIGNAL FROM THERMOSTAT RAPIDLY FLASHING RED RECEIVER IN SETUP MODE

DIP SWITCH SETTINGS: OFF NOT SE%UP TO RECEIVE INFORMATION FRO_4 A THE RI_OS [AT ON READY TO RECEIVE INFORTV_ATIONFROM THERMOSTAT AFTER SEFUP _SCOMPLETE

ZONE I

_

ZONE 2 ZONE 3

SET-UP: MOVE DIP SWITCH TO ON POSFION AND MAKE THERMOSTAT CALL FOR FAN NOTE ALL OTHER THERMOSTATS MUST BE OFF (NOT CALUNG) DURING SE%UP

ZONE I Y W

G

ZONE 2

ZONE 3

Y

Y

W

G

W

G

/_

R

C RZRZRZ

M20_8 Fig. 7. Connecting

Fig. 8. Connecting

69-1630-1

the

W8665E

RF Zone

Z_

LEAVE

JUMPER

the

W8665E

O/B

TM

Panel to the EMM-3 MiniZone thermostat zone COl_lrlectiorls.

DISCONNECTED

ON

EMM-3U

TM RF Zone Panel to the EMM-3U up to three thermostat zone

6

TM

Panel

to control

1H/1C

with

up three

BOARD

Zone Control connections.

Panel

to operate

up to 2H/2C

with

W8665A,E

RF RECEIVER

MODULE

I

W8665E ZONE I Y

W

G

ZONE 2

ZONE 3

Y

Y W

W

G

I I

G

/_

_'_'_±

_



,J TR/

A

FACTORY THE

INSTALLED

THREE

JUMPER

RZ TERMINALS

ARE

INTERNALLY

24V, 40VA TRANSFORMER

CONNECTED

M20165B

Fig. 9. Connecting

the W8665E RF Zone Panel to the TZ-3 3H/2C with up to three thermostat TM

ZONE I

ZONE 2

ZONE I

ZONE 2

ZONE S

w £

¥ w_

_ w _]

TotalZone® Zone Control zone connections.

Panel

to operate

up to

ZONE S

7-

/k_

zRzRz

oo00 oooooooo ooooooooo oo oooooooo oooo oo ,_._

£._

£._

,_._ _o T210 OAMPER XFRM

TZ 4 Z_

FACTORY

Z_

LEAVE

Fig.

INSTALLED

O/B JUMPER

10. Connecting

JUMPER

THE

D}SCONNECTED

the

THREE

RZ TERMINALS

ON TZ-4

ARE INTERNALLY

CONNECTED

BOARD

M20572A

TM W8665E RF Zone Panel to the TZ-4 3H/2C with up to three thermostat

7

TotaIZone® Zone zone connections.

Control

Panel

to operate

up to

69-I630-1

W8665A,E

RF RECEIVER

MODULE

W8665E

t L8148!

END

L8124

SWITCH

T(TV)

i

V8043

L2 L/

Z'_REMOVEFACTORYINSTALLEDJUMPER

Fig.

11. Zoned

hot water

heat

using

V8043F

zone

--

I

r_I20686A

valves,

an L8148/L8124

Aquastat

and

a transformer.

7._

Y wQ

Y wG

Y wG

c RZRZRZ

N8665 r_

L8148

/ L8124

V8043F

V8043F L2 L/ Z'_

Fig.

12. Zoned

69-1630-1

hot water

heat

REMOVE

FACTORY

and single-zone

INSTALLED

JUMPER

cooling using V8043F and a transformer.

8

M20687A

Zone

Valves,

and

L8148/L8124

Aquastat

W8665A,E

RF RECEIVER

MODULE

IN8665E

V8043E

• (TV)

T

L8148 / L8124

Fig.

13. Zoned

hot

water

V8043E

Z_

FACTORY

FNSTALLED

Z_

CONNECT

VE043E

YELLOW

Z_

CONNECT

VE043E

RED LEADWIRES

heat

using

V8043E

Zone

JUMPER LEADWFRE

Valves,

TO W8665E

TO L8148/L8124

an L8148/L8124

Aquastat

and

a transformer.

7.-. Y

Y WG

wo

¢ RZRZRZ

Y WC

W8665E

V8043E

_

V89_

V8043E

C

• (TV)



L8148 / L8124

Fig.

14. Zoned

hot water

heat

Z_

FACTORY ENSTALLEDJUMPER

Z_

CONNECT VEO43E YELLOW LEADWIRE TO W8665E

Z_

CONNECT VEO43E RED LEADWIRES TO L8148/L8124

and

single-zone

cooling using and a transformer.

9

_

L2 L/

ve043E

Zone

Valves,

an L8148/L8124

Aquastat

69-I630-1

W8665A,E

RF RECEIVER

MODULE

W8665E

R8222

r (TV)

R8222

T

L8148 / L8124

PUMP

Z_FACTORYINSTALLEDJUMPER

Fig.

15. Zoned

hot water

heat with

circulating

pumps using transformer.

R8222

Relays,

an L8148/L8124

Aquastat

and a

7_

N8665E

R8222

R8222

L8148 / L8124

pu[_lm

PUMP

Fig.

16. Zoned

hot water

heat and

M20691A

single-zone

cooling

Aquastat

69-1630-1

using

circulating

and a transformer.

10

pumps,

R8222

Relays,

an L8148/L8124

W8665A,E

RF RECEIVER

MODULE

SETUP Setting Up W8665A,E to ReceiveSignals from the T8665A Thermostat(s)

d. NOTE:

The T8665A Thermostat(s) require(s) setup to send signals to the W8665 Receiver Module to operate: • The W8665A Receiver is used for single-zone applications. • The W8665E RF Zone Panel is used for up to three T8665A Thermostats for multi-zone applications.

Use Fan key to turn off fan. At any time, if you want to stop the thermostat from sending signals to the W8665 Receiver, turn the DiP switch to Off. Then repeat steps 2 through 5 to set up the thermostat to send signals to the W8665 Receiver.

TM

6. 7. 8.

IMPORTANT Be sure the thermostat is at least five feet away from the W8665 during setup. Maximum distance is 200 feet.

Repeat steps 2 through 5 for zones two and three. Set System and Fan keys to desired locations. Attach the zone number sticker, included with the thermostat, onto the thermostat case on the inside of the thermostat cover. See Fig. 5.

Single Zone Applications (1 W8665A/1 T8665A) 1. Power up the W8665A and install the batteries in the T8665A Thermostat. 2. Place the W8665A Zone 1 DiP switch to the On position. NOTE:

P_aceo_elabel _ns_e eacht_efmostatdoor

The W8665A Zone 1 LED will flash.

M_342G

Fig.

Press the thermostat Fan key to On: a. The receiver accepts the message and stores the identity. b. The zone 1 LED stops flashing. c. The thermostat is now set to send signals to the W8665A Receiver. NOTE:

4.

At any time, if you want to stop the thermostat from sending signals to the W8665 Receiver, turn the DiP switch to Off. Then repeat steps 13 to set up the thermostat to send signals to the W8665 Receiver. Applications

(1 W8665E!Up

2. 3. 4.

to 3

W8665E Single and Multi-Stage Operation The first stage is energized by the themlostat. To control multistage conventional and heat pump systems, the W8665 must be wired to a zone control panel that is able to control multiple stages of heat and/or cool (such as the EMM-3U Universal Electronic MiniZone Control Panel or TZ-4 TotalZone® Zone Control Panel). The zone panel (not the RF panel) controls these stages based on the number of zones calling or with a timer. See the Zone Control Panel Instructions for more details on how to control up to three stages of heat and two stages of cool.

The W8665E zone 1 LED will flash.

Press the thermostat Fan key to On: a. The receiver accepts the message and stores the zone identity. b. The zone 1 LED stops flashing. c. The thermostat is now set to send signals to the W8665E Receiver. NOTE:

of

On a ca_l for heating or cooling from any zone, tile thermostat sends a signal to the W8665E to bring on the heating or cooling in that zone until the call is satisfied. The Comm LED flashes when the W8665E receives a signal from the thermostat in any zone to turn on the system or approximately every ten minutes as a status update. On a call for heating, cooling or fan, the zone LED lights red.

Power up the W8665 and install the batteries in the T8665 Thermostats. Set the thermostats so no zones are calling for system or fan. Set up each zone separately to ensure that a unique address is used for each zone. Place the zone 1 DiP switch on the W8665E Receiver to the On position.

NOTE:

inside

W8665E Sequence of Operation

T8665A) 1.

for

On a call for heating or cooling, the thermostat sends a signal to the W8665A to bring on the heating or cooling until the call is satisfied. The Comm LED flashes when the W8665A receives a signal from the thermostat to turn on the system or approximately every ten minutes as a status update. On a call for heating, cooling or fan, the zone LED lights red.

Use Fan key to turn off fan.

Multizone

stickers cover.

W8665A Sequenceof Operation

Set System and Fan keys to the desired locations.

NOTE:

number thermostat

OPERATION

The word, On, and a fan blade _ appear in the thermostat display to indicate the thermostat is calling for the fan to turn on.

d.

17. Zone

The word, On, and a fan blade tt appear in the thermostat display to indicate the thermostat is calling for the fan to turn on. II

69-I630-1

W8665A,E

RF RECEIVER

MODULE

LED Operation (See Table 4) NOTE:

See Setting up W8665A,E Receiver Module to Receive Signals from the T8665A Thermostat section.

Table 4. LED Operation. LED

LED action

Meaning

Comm

Flashes rapidly for 2-3 seconds.

Indicates device is currently receiving information from the T8665 Thermostat.

Zones 1-3

On constantly.

Indicates system (heat, cool, or fan) is on.

Zones 1-3

Off constantly.

Indicates system (heat, cool, or fan) is off.

Zones 1-3

Flashes rapidly until signal is received,

indicates zone is being set up to receive signals from a transmitter (T8665 Thermostat).

Zones 1-3

Flashes continuously.

Indicates e problem receiving signals from the transmitter (T8665 Thermostat). See Troubleshooting Guide for more information.

69-1630-1

12

W8665A,E RF RECEIVER MODULE

TROUBLESHOOTING (TABLE 5)

Table 5. Troubleshooting Symptom

Possible

Cause

Guide. Action

Display does not come on.

Thermostat is not being powered.

Check if batteries are present and installed correctly. • if batteries are in and installed correctly, replace thermostat.

Heating does not come on. System on indicator ((_ = heat)is showing in display.

Communication completed.

End and repeat the call for heat. Check the Comm LED and Zone LED on the W8665 while the call is being made. • if the Comm LED does not flash when thermostat first calls for equipment, turn that zone DIP switch to Off. Refer to Setup section to reset the W8665. • if the Zone LED flashes continuously, turn that zone DiP switch to Off. Refer to Setup section to reset the W8665. • Check if 24 Vac is present: • Check between R and C on W8665. • Check between W of troubled zone and C on W8665. If voltage is present, troubleshoot heating system.

Cooling does not come on. System on indicator (>_fi = cool) is showing in display.

is not being

Heating load at W8665 is not connected correctly.

Thermostat is too close to W8665.

T8665 Thermostat should be at least five feet away from the W8665 during setup and operation.

Thermostat is too far away from W8665.

Maximum distance between W8665 and T8665A Thermostat should not exceed 200 feet.

Communication completed.

End and repeat the call for cool. Wait five minutes for the compressor delay to end. • if the Comm LED does not flash when thermostat first calls for equipment, turn that zone DIP switch to Off. Refer to Setup section to reset the W8665. • if the Zone LED flashes continuously, turn that zone DiP switch to Off.Refer to Setup section to reset the W8665. • Check if 24 Vac is present: • Check between R and C on W8665. • Check between Y of troubled zone and C on W8665. If voltage is present, troubleshoot cooling system.

is not being

Cooling load at W8665 is not connected correctly.

Thermostat is too close to W8665.

T8665 Thermostat should be at least five feet away from the W8665 during setup and operation.

Thermostat is too far away from W8665.

Maximum distance between W8665 and T8665A Thermostat should not exceed 200 feet.

Wait is displayed and the call for cool has not started.

Compressor effect.

Compressor protection can be set on the T8665A from 0 to 5 minutes to prevent compressor damage due to rapid cycling. Wait until the compressor protection period expires.

2nd stage heat or cool (or 3rd stage heat) does not energize.

W8665 is not wired to a TZ-4 TotalZone Zone Control Panel or EMM-3U Universal Electronic MiniZone Control Panel that controls the multiple heat and cool stages.

protection is in

TM

13

Wire W8665 to TZ-4 TotaiZone Zone Control Panel or EMM-3U Universal Electronic MiniZone Control Panel to control multi-stage systems. TM

Check TZ-4 TotalZone Zone Control Panel or EMM-3U Universal Electronic MiniZone Control Panel and set correctly. TM

69-I630-1

W8665A,E

RF RECEIVER

MODULE

Table

Symptom Fan does not come on with a call for electric heat.

5. Troubleshooting

Possible Cause

Guide.

Action

Electric heat setting is not configured.

Set thermostat installer Setup Number 2 to 1 for electric heat. See thermostat instructions for details.

Fan load at W8665 is not connected correcfiy.

Check that 24 Vac is present between R and C. Check that 24 Vac is present between G and C. If voltage is present, troubleshoot system.

69-1630-1

14

W8665A,E

RF RECEIVER

MODULE

FCCID: CFS8DL5800TSTAT CANADA:

1748A12113

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference

received, including interference

that may cause undesired operation.

FEDERALCOMMUNICATIONSCOMMISSION(FCC) STATEMENT This equipment has been tested to FCC requirements following statement for your information:

and has been found acceptable for use. The FCC requires the

This equipment generates and uses radio frequency energy and, if not installed and used properly; that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation, tf this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • • • • •

If using an indoor antenna, have a quality outdoor antenna installed. Reorient the receiving antenna until interference is reduced or eliminated. Move the radio or television receiver away from the receiver/controL Move the antenna leads away from any wire runs to the receiver/control. Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits. If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user or installer may find the following booklet prepared by the Federal Communications Commission helpful: "Interference Handbook" This booklet is available under Stock No. 004-000-00450-7 20402.

from the US Government Printing Office, Washington, DC

The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment.

15

69-I630-1

W8665A,E

RF RECEIVER

MODULE

Honeywell Automation Hoile_

1985 Dougla_ Ooldei_

alld

(ontrol

Solutio_ls

Driw

North

35 DyilamlC

55422

Sca_oiough, M 1V 4Z9

e[1

Valley',

69-1630-1

H one)_,, ell Limir_d-H

MN

G.H.

Rev

9-03

oile_._ _11Li1_litee

Drive Ontario

_

paper lO% Printedcontaining in U S A at on le_st recycled post ¢onsume_ paper fibers

www.honeywelLcom/yourhome