X33-1446 Rheem RGEA16 Editible Submittal Sheets

SUBMITTAL COVER SHEET PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR SUBMITTED BY

DATE

UNIT SUMMARY Quantity Unit Designation Model No. Total Cooling Sensible Cooling Air Ent. Evaporator Air Lvg. Evaporator Heating Input Heating Output CFM/ESP EER/SEER Electrical Minimum Ampacity Min.-Max. Breaker Net Unit Weight Accessory Catalog Form Number

ACCESSORIES:

NOTES:

PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640

FORM NO. X33-1446

SUBMITTAL SHEET FOR PACKAGE GAS ELECTRIC RGEA16 SERIES, Nominal Sizes 2-5 Tons [7.0-17.6 kW] FRONT VIEW

BACK VIEW

207/8" [530 mm]

39/16" [90 mm] SIDE SUPPLY DUCT OPENING

FIELD POWER WIRE ENTRANCE FIELD CONTROL WIRE ENTRANCE

227/8" [581 mm]

2211/16" [576 mm] 471/2" [1207 mm]

47/8" [124 mm]

3515/16" [897 mm]

1315/16" 75/16" [338 mm] [186 mm] THREADED PVC CONDENSATE DRAIN CONNECTION (3/4" N.P.T.)

191/8" [486 mm]

15" [381 mm]

133/4" [349 mm] TYP.

131/4" [337 mm]

LIQUID PRESSURE SERVICE PORT SUCTION PRESSURE SUCTION PORT

47/16" [113 mm] 81/2" [216 mm] TYP.

143/16" [360 mm] TYP.

SIDE RETURN DUCT OPENING

SHOWN WITH DUCT COVERS REMOVED.

SIDE VIEW FLUE EXHAUST HOOD

UNIT DATA COOLING PERFORMANCE TOTAL CAPACITY* ........................ _______ MBH SENSIBLE CAPACITY* .................. _______ MBH OUTDOOR DESIGN TEMP. _______ °F [°C] DB/WB TOTAL SUPPLY AIR ................ _______ CFM [L/s] TEMP. OF AIR ENTERING EVAPORATOR COIL...... _______ °F [°C] DB/WB POWER INPUT REQUIREMENT ........ _______ kW SEER/EER RATING ................................ _______

GAS SUPPLY ENTRANCE

1015/16" [278 mm] 21/2"

[63.5 mm]

SIDE VIEW FILTER ACCESS PANEL (FOR UNIT MOUNTED FILTER ACCESSORY)

OUTDOOR COIL PROTECTIVE GRILLE

111/16" [42.9 mm]

BLOWER/ EVAPORATOR ACCESS PANEL

(*uses blower motor heat)

HEATING PERFORMANCE GAS HEAT INPUT CAPACITY.......... _______ MBH GAS HEAT OUTPUT CAPACITY ...... _______ MBH STEADY STATE EFFICIENCY ................ ________

SUPPLY AIR BLOWER PERFORMANCE TOTAL SUPPLY AIR ................ _______ CFM [L/s] TOTAL RESISTANCE EXTERNAL TO UNIT...................................... _______ IWG BLOWER SPEED .......................... _______ RPM POWER OUTPUT REQUIREMENT .. _______ BHP MOTOR RATING ........................ _______ HP [W] POWER INPUT REQUIREMENT ........ _______ kW

527/16" [1332 mm]

ELECTRICAL DATA POWER SUPPLY...................... ____________ Hz TOTAL UNIT AMPACITY................ _______ AMPS MINIMUM WIRE SIZE .................... _______ AWG MAXIMUM OVERCURRENT DEVICE FUSES HACR BREAKER ........ _______ AMPS

Full Perimeter Curb

TOTAL UNIT WEIGHT TOTAL OPERATING WEIGHT .... _______ LBS [kg] (including field-installed accessories)

CLEARANCES FRONT

48" [1219 mm]

CONDENSER COIL

18" [457 mm]

DUCT SIDE

12" [305 mm]

EVAPORATOR END

36" [914 mm]

ABOVE UNIT

60" [1524 mm]

[ ] Designates Metric Conversions

479/16" [1208 mm]

451/16" [1145 mm] INSIDE

TOP VIEW

BOTTOM VIEW

13/16" [30 mm] TYP.

11/2" [38 mm] TYP.

BOTTOM RETURN DUCT OPENING

5013/16" [1290 mm]

153/8" [391 mm]

191/2" [495 mm]

497/16" [1256 mm] INSIDE

BOTTOM SUPPLY DUCT OPENING

141/4" [362 mm] TYP.

OUTDOOR FAN GRILLE & COMPRESSOR ACCESS

33/16" [97 mm]

313/16" [97 mm]

[ ] Designates Metric Conversions

49/10" [125 mm]

FEATURES 1. All models feature Scroll ® compressors for maximum efficiency and quiet operation. 5 Ton RGEA16 models feature UltraTech™ Scroll 2-Stage compressors with Comfort Alert™ diagnostics (see below), high/low pressure switches, and hard start kits. 2. Louvered condenser compartment for protecting the coil against yard hazards and/or weather extremes. 3. One-piece top with a deep flange to help keep water out of the unit. 4. Supply and return air openings feature a one-inch tall flange to prevent water migration into the ductwork. 5. Access panels have “weep holes” and channels to further help manage water run-off. 6. Side and down discharge options available on all models. All models are shipped ready for horizontal application. 7. Easily accessible blower section complete with slide-out blower. The RGEA16 comes standard with variable speed motor with adjustable airflow in heating and cooling. The variable speed motor also comes with a interface that allows for dehumidification when used in continuous humidistat. The variable speed system is capable of 1 inch external static. 8. Refrigerant connections are conveniently located for easy service diagnostics. 9. Condenser and evaporator coils feature enhanced fins for better heat transfer and rifled copper tubing for greater efficiency.

10. Inside the easily accessible furnace compartment is the draft inducer motor. This motor is specially designed for quiet reliable operation. In addition to the draft inducer motor, the in-shot gas burners and manifold efficiently regulate the flow of gas for combustion. These new gas/electric units also feature direct-spark ignition and remote flame sensors for added reliability and efficiency. 11. All units feature an internal trap on the condensate line eliminating the need for installing an on-site external trap. 12. Easily accessible control box. 13. Single point wiring simplifies installation. 14. Our gas/electric package units feature a tubular heat exchanger design. Tubular heat exchangers are more efficient and durable than older-style clamshell heat exchangers. Stainless Steel Heat Exchanger is a standard feature on the RGEA16 and is backed by a limited lifetime warranty when installed in a residential application, and a 20 year warranty when installed in a commercial application. Two stage gas heat is standard on the RGEA16 models. 15. Thermal expansion valve standard on all models for superior superheat control, reliability, and energy efficiency at all operating conditions. 16. Filter drier standard on all models (not shown). 17. Rugged baserail included for improved installation and handling 18. Complete factory charged, wired and run tested. 19. Molded compressor plugs.

FIELD INSTALLED ACCESSORIES Roof Curb (8" [203.2 mm], 14" [355.6 mm] & 24" [609.6 mm] High Full Platform)........................ Roof Curb (14" [355.6 mm & 24" [609.6 mm] Sloped Platform) .................................................. Filter Accessory.......................................................... Lift Kit (For Rigging) .................................................. Time Delay Relay ...................................................... Start Assist ................................................................ Low Ambient Control .................................................. Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.

Low Pressure Control ................................................ Economizer (Enthalpy Controlled) Downflow Only.......... Manual Fresh Air Damper............................................ L.P. (Propane) Kit ...................................................... Transition (Rectangular-Round) Downflow/Sideflow ...... Concentric Diffuser and Grille ...................................... High Pressure Control ................................................ Thermostat ..............................................................

Rheem Sales Company, Inc. P.O. Box 17010, Fort Smith, AR 72917

“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.” PRINTED IN U.S.A.

1-15 QG

FORM NO. X33-1446 Supersedes Form No. X33-1209