x
treme
Diesel Generators
Xtreme Reliability –
Airman Japan - designed, engineered and manufactured for use in rental, construction and mining.
Xtreme Efficiency –
Using only the best premium Japanese engines such as Kubota and Isuzu.
Xtreme Performance – Maintenance Free brushless Alternator and minimal soundwave distortion for sensitive equipment use.
Powered by
Xtreme Back Up –
Not only are these ultimate Generators supported by 12 month International Warranties but Blue Diamond Machinery operates a mechanical workshop and has mobile field support.
Xtreme Protection – All Weather construction to eliminate rain penetration of the machine.
Xtreme Mobility –
Exceptionally compact and lightweight.
Xtreme
Environmental Awareness –
Ultra Quiet (60 DB at 1 M range!) and meets Japans very tight emissions regulations.
x
treme
Diesel Generators
High Generating Performance
Better Generating Performance SDG series generators are coupled to low transient reactance alternator and reinforced damper coil. This increases the negative-phase-sequence current capability and minimizes the output waveform distortion. Therefore, they are suitable for wide range of non-linear load such as inverter, thyrister, computer control, discharge lighting, precision instruments and instrumental device.
Preset Voltage Regulation
within
0.5%
0
Environmental Friendly Low Noise Level
Noise Level (at 7 meters distance from the machine at no load)
Operating noise has been minimized with low noise engines, equipped with highly attenuated muffler and special exhaust system design. All SDG models (excluding SDG100S) are adopted panel structure to minimize structural clearance and reduce internal space. Combined inlet duct design further reduces the overall noise level. Exhaust muffler system is mounted on special design support structure to reduce vibration.
Super Silent SDG13S ~ 220S Ultra Super Silent SDG25AS~150AS
Very noisy construction job
Under the railway road overpass when a train is passing over head
In the subway carriage
In train car
Super Silent SDG series
In private company's common office
Silent SDG300S ~ 800S
1m distance at usual conversation
In quiet office room In residential area at night
Clean Engine SDG13~45(excluding 25AS,45S-F,45S), 100S-F~150S-F generators are approved by Japanese Government Authority as "The 3rd Diesel Engine Driven Construction Machinery Exhaust Gas Regulation". Other generators are approved by Japanese Government Authority as "The 2nd Diesel Engine Driven Construction Machinery Exhaust Gas Regulation".
4
2
dB(A)
Blowby Gas
50
Ultra Super Silent SDG-AS series
(SDG13~100,125S-F,150S-F)
The generators have been newly designed to circulate the blowby gas inside the machine (PCV system). They are driven by such environmental friendly engine to keep the generator outside as well as the inside from being stained.
x
treme
treme
Diesel Generators
Fully Equipped Customised Options
Dual Voltage Models Extended Fuel Tank Blue Diamond offers customisation to your specific requirements By changing over the short connecting plate in the control panel, the three phase output voltage can be switched toRange 200/220V from Options
400(380)/440V and vice versa. SDG 13 with extended 40 hour run time tank. When starting engine, the indication lamp at the operation panel goes on to display the operating voltage immediately. Mine Specification The Skid Fabricated was for Heavy Duty use in the unforgiving Australia Rental Market. Heavy Duty Bunded Fuel Tank
400(380)/440V
200/220V
1phase
Lockable Battery Isolator Emergency Stop
U
RCD Protection Fire Extinguisher
V
115/127V
W
switch
O
3phase
U
V
1phase
dewatering company.
W
O
231(219)/254V
3phase
400(380)/440V
200/220V
Parallel Operation Using Com Ap controllers two SDG 150’s were set up to share load running a asphalt plant on a BHP site in Western Australia.
Continuous Operation available for a long time A large capacity fuel tank and low fuel consumption engine have made the generators run continuously for a long time. Also for SDG13S~300S three-way selection valve is provided as a standard equipment to be easily connected to an additional outside fuel tank. One way Mechanical Service selection method by one selection lever avoids wrong We offers when a range of preventative maintenance and service options for operation changing over suction side to return side and Diesel Generators sold by us, or others. vice versa.
Trailer Mounted Automatic Air Bleeding System (SDG13~150)
Airman generators are popular in the rental markets due to the bullet proof Automatic Air Bleeding Device is quality and strong compact canopy. bleed This makes the units ideal for Trailer equipped to automatically air from fuel line system. This eliminates the need to prime the fuel system again should the generator be shutdown due to running out of fuel. Simply top up the fuel and turn the key switch to operation position, air in the fuel line system is bled automatically. As for both SDG125S/150S/150AS, it is possible to automatically bleed air by pushing the push button provided at the operation panel.
Monthly Service Plans In caseand the mounted fuel tank is used Routine Preventative Maintenance is essential for the long term performance of your generator. A Standby generator can sit Selector handle for long periods of time without use and so it is important it is properly maintained, so that when it is required it keeps your business
Parallel Operation (SDG125,150S/AS)
For Prime Power Sets or Larger Fleets we can customise a plan to your High requirements. Accurate Parallel Operation System (CCR cross current prevention device) is Call our Operations Manager Chris Simpson on 0439 665 960 to discuss. provided as a standard equipment. Plug Combined with an accurate Emergency AVR(automatic voltage regulator), it is Field based emergency response due to mechanical failure is unfortunately going occur. parallel operation possible to to perform Engine being fueled by separate fuel tank Equipped with expert mechanical staff and a national network of servicemanually. agents we are Suction side equipped to deal with any issue.
20mm
Return side Fabrication Custom fabrication is a big part of what we do. Custom Fuel Tanks, Custom Skids and Bunds, Lifting and Protective Frames are manufactured for our Kewdale workshop.
15
Parts Blue Diamond stocks spare parts for all equipment we sell and we are able to source parts from a variety of manufacturers for diesel generators, compressors and welders. Selector handle
3
x
treme
Diesel Generators
Easy Maintenance
Fuel filter
Fuel air-bleeding electromagnetic pump
Air cleaner
Fuel pump
Reserve tank
SDG45S-F
Engine oil level gauge
Engine oil filter
Engine oil filler port
Sedimentor
Maintenance with Great Ease
Radiator
Flat Frame
Daily inspection such as engine oil and coolant level can be done by opening the right side door. For SDG45 & 60, one battery of two mounted batteries has been eliminated, thus dedicated to reducing industrial waste and maintenance cost.
(SDG13~300, excluding 60AS/100S/150AS)
The interior of the machine is flatly constructed so as to be easily cleaned.
Mounting and Demounting Fuel Tank Mounting and demounting fuel tank has been made easier by making the bottom floor entirely flat. It is easy to clean the interior by removing the fuel tank. Radiator
Inspection and Cleaning Radiator For SDG series inspection of radiator and cleaning radiator can be easily performed by removing both side front covers and dividable fan shrouds.
Newly-Designed Panel Construction
(excluding100S)
The bonnet is of panel constructed type for easily dismantling and assembling for maintenance.
Maintenance Cycle Model SDG13,25,220 SDG45~150 SDG300 SDG400,500
unit : per hour
Engine oil 250 1 500 1 250 1 500 2
Oil filter 500 1 500 1 250 1 500 2
1 For the items marked with a asterisk, first run in oil / filter change 50hr.
64
Fuel filter 500 500 500 500
Air element 1,000 1,000 1,000 1,000
2 For the items marked with a asterisk, first run in oil / filter change 250hr.
x
treme
Diesel Generators
Operation Operation
Engine Starting Efficiency
Electronic Governor
(SDG13~45,100S-F~150S-F,220,400,500)
For SDG13~220, engine preheating system consists of Engine Starting Efficiency quick heating glow plug to easily start up engine in low temperature conditions. For SDG13~220, engine preheating system consists of SDG220~500 are driven highstart start-up engineinwhich quick heating glow plug toby easily up engine low exercises great power for earth auger and vibro-hammer temperature conditions. operations requiring instant flow. Start-up SDG220~500 are driven byelectric high start-up engine which characteristics been more auger improved electric motor exercises greathave power for earth andfor vibro-hammer start-up as well as turbo charger and governor improved. operations requiring instant electric flow. Start-up
Stable engine speed can be secured because engine Electronic Governor speed is made easier to(SDG13~45,100S-F~150S-F,220,400,500) be adjusted. ItStable is possible to select frequency and make fine engine adjustment engine speed can be secured because of engine speed only by moving up and down "Switch for fine speed is made easier to be adjusted. adjustment of engine speed". It is also possible easily to It is possible to select frequency and make fine adjustment perform" Operation" withup theand slowdown switch.for fine of engineIdling speed only by moving down "Switch adjustment of engine speed". It is also possible easily to perform" Idling Operation" with the slowdown switch.
characteristics have been more improved for electric motor Control Panel start-up as well as turbo charger and governor improved. Control devices for generator and electrical appliances for Control Panel inside the control panel for better engine are concentrated maintenance. Control devices for generator and electrical appliances for engine are concentrated inside the control panel for better maintenance.
Panel light Voltmeter Ammeter Panel light Frequency Voltmeter meter Fuel gauge with hour meter Ammeter Water temperature Frequency meter meter Three phase circuit breaker Fuel gauge with hour meter Voltage regulator Water temperature meter Current selector switch Three phase circuit breaker Leakage relay Voltage regulator Output Currentindicator selector lamp switch Warning Leakage lamps relay (For details, see the followings) Starter Output switch indicator lamp Panel light switch Warning lamps (For details, see the followings) Operation mode Starter switch selection switch Frequency selection switch Panel light switch Operation mode selection switch Frequency selection switch
SDG45S-F Panel
SDG45S-F Panel
Safety Safety
Completely Monitoring System For SDG60~150, 300S, in order to eliminate the electric Completely Monitoring System fault when restarting engine, they are provided with shunt trip asFor standard equipment toin trip the main circuit breaker in case SDG60~150, 300S, order to eliminate the electric of emergency shutdown. If electric fault occurs, the warning fault when restarting engine, they are provided with shunt trip lamp goes onequipment and opens breaker. as standard tothe tripgenerator the main circuit breaker in case of emergency shutdown. If electric fault occurs, the warning lamp goes on and opens the generator breaker.
Warning Lamps & Emergency Stop Model
Oil press. Drop
Water temp. rise
Over Speed
Overcurrent, Short-circuit
Electric Leakage
Faulty Battery charging
Air filter Clogging
Oil press. Drop
Water temp. rise
Over Speed
Overcurrent, Short-circuit
Electric Leakage
Faulty Battery charging
Air filter Clogging
Warning Lamps & Emergency Stop SDG13 45 Model SDG60 150 ,300 SDG13 45 SDG100S-F 220S-F SDG220 ,400 ,500 SDG60 150 ,300
Warning lamp goes on and it causes Engine emergency stop
SDG100S-F 220S-F Warning lamp goes on SDG220 ,400 ,500 Breaker OFF
Warning lamp goes on and it causes Engine emergency stop Warning lamp goes on Breaker OFF
7 75
x
treme
Diesel Generators
SDG Series
SDG13S
SDG25S
SDG45S
SDG100S
SDG60S SPECIFICATIONS Model
SDG13S -3B1
SDG125S/150S
SDG25S
SDG45S
50 20
50 37
-3B1
-3A8
SDG60S -3A6
SDG100S
SDG125S
SDG150S
50 80
50 100
50 125
-3A5
-3A6
-3A6
Generator Frequency Rated Output Voltage Power Factor
Hz kVA V %
60 13
50 10.5
60 25
60 45
50 50
60 60
60 100
60 125
60 150
50Hz : 200 or 380 or 400 or 415 , 60Hz : 220 or 440(Dual Voltage) 80 Continuous Brushless (with A.V.R.) 3-Phase , 4-Wire
Class of rating Exciting Method No. of Phase Diesel Engine
Kubota D1503-K3A Kubota V2403-K3A Kubota V3800-DI-T-K2B Isuzu BB-4BG1T Isuzu DD-6BG1T Hino J08C-UP 3 4 4 4 6 6
Make and Model No. of Cylinder Type(4Cycle,Water-Cooled) Total Displacement Rated Output Speed Fuel Fuel Tank Capacity
Direct Injection,Turbo charged
Swirl Chamber
Hino J08C-UD 6
Direct Injection, Turbo charged,Intercooled
L 1.499 2.434 3.769 4.329 6.494 7.961 7.961 PS(kW) 15.6(11.5) 18.6(13.7) 26(19.1) 32(23.7) 51.7(38.0) 62(45.6) 65.4(48.1) 78(57.4) 100(73.6) 124(91.2) 131(96.3) 153(112.7) 160(118) 190(140) rpm 1,500 1,800 1,500 1,800 1,500 1,800 1,500 1,800 1,500 1,800 1,500 1,800 1,500 1,800 Diesel Fuel Oil L
58
70
100
135
225
250
250
Fuel Consumption(50/75%Load) L/hr 1.9/2.4 2.4/3.0 3.0/4.0 3.8/5.0 4.4/6.4 5.5/8.0 6.0/8.6 7.5/10.5 10.2/14.5 13.2/19.0 11.5/16.4 15.3/21.0 14.7/19.4 17.7/24.3 Cooling Water Capacity
L L
6.5 5.7
9.5 7.0
13.2 11
14 15
18 24
24.5 22
24.5 22
Battery(Capacity 5hrs)
(Ah)
80D26R(55) 1
80D26R(55) 1
80D26R(55) 1
80D26R(55) 1
95D31R(64) 2
95D31R(64) 2
95D31R(64) 2
1,480 650 950 520 580
1,550 700 980 610 680
1,870 860 1,220 900 1,010
2,090 860 1,220 1,120 1,260
2,600 1,000 1,400 1,640 1,870
2,990 1,180 1.480 2,050 2,300
2,990 1,180 1.480 2,180 2,430
Lublicating Oil Capacity
Dimensions & Weight Overall Length Overall Width Overall Height Net Dry Mass Operating Mass
mm mm mm kg kg
Sound Level Sound power level in decibels Sound pressure level
dB dB(A)
83 56
90 57
59
For other voltages than above-mentioned ones, contact us. 7m in four directions from machine and at no load
8
6
87 63
57
90 60
59
91 63
61
92 64
63
94 65
63
66
x
treme
Diesel Generators
SDG220S
SDG300S
SDG220S
SDG300S
SDG400S
SDG500S
SDG400S
SDG500S
SPECIFICATIONS
SDG220S
Model
Generator Model Frequency
Generator Rated Output Frequency Voltage
Rated Output Power Factor Voltage Class of rating
Power Factor Exciting Method Class rating No. of of Phase
Hz kVA Hz V
kVA % V
Speed Fuel Tank Capacity FuelConsumption(50/75%Load) Fuel
L PS(kW) L rpm
PS(kW) rpm L L/hr
Lublicating Oil Capacity L (Capacity Battery 5hrs) (Ah) Cooling Water Capacity Dimensions & Weight L
Battery(Length Capacity 5hrs) (Ah) Overall mm Dimensions Overall Width & Weight
Overall Height Operating Mass Net Dry Mass Sound Level
Operating Mass Sound power level in decibels Sound Level Sound pressure level
-3A6
(with A.V.R.) Brushless 80 Continuous 3-Phase , 4-Wire Brushless (with A.V.R.) 3-Phase , 4-Wire Komatsu SA6D140E-3-B Komatsu SAA6D125E-2-B
SDG500S -3A6 60 50 500 450 60 50 500 450
Komatsu SAA6D140E-3-B
6
Komatsu SA6D140E-3-B Komatsu SAA6D140E-3-B Direct Injection,Turbo charged Direct Injection,Turbo charged,Intercooled 15.24 15.24 11.94 11.04 Direct Injection,Turbo charged,Intercooled Direct Injection,Turbo charged Direct Injection,Turbo charged,Intercooled 581(427) 246(181) 270(199) 315(232) 349(257) 421(310) 485(357) 519(382) 15.24 11.94 11.04 1,500 1,800 1,500 1,800 1,500 1,800 1,500 15.24 1,800 581(427) 246(181) 270(199) 315(232) 349(257) 485(357) 519(382) Diesel Fuel421(310) Oil 1,500 390 1,800 1,500 490 1,800 1,500 490 1,800 1,500 490 1,800 Diesel Fuel Oil 55.3/78.3 22.5/31.8 26.2/36.3 30.0/43.1 34.3/50.6 39.7/56.6 46.7/65.3 48.4/69.2 490 490 390 490 79 91.5 37 62 6
22.5/31.8 39 26.2/36.3 (120) 2 170F5137 39
30.0/43.1 43.5 34.3/50.6 (120) 2 170F5162 43.5
39.7/56.6 69 46.7/65.3 (176) 2 225H5279 69
48.4/69.2 91.5 55.3/78.3 91.5 (176) 2 225H52 91.5
(120) 2 170F51 3,700
(120) 2 170F51 3,900
(176) 2 225H52 4,150
(176) 2 225H52 4,550
1,300 3,700 1,670 1,300 3,240 1,670 3,630 3,240 3,630 94
1,400 3,900 1,760 1,400 3,790 1,760 4,290 3,790 4,290 98
1,400 4,150 2,040 1,400 5,120 2,040 5,670 5,120 5,670 99
1,600 4,550 2,090 1,600 6,170 2,090 6,750 6,170 6,750 99
mm mm mm mm kg mm kg kg
kg dB dB(A)
-3A6
SDG300S SDG400S -3A6 -3A6 50 60 50 60 270 300 350 400 50or 380 or 40060 60 Voltage) 50Hz : 200 or 415 , 60Hz :50 220 or 440 (Dual 270 300 350 400 80 50Hz : 200 or 380 or 400 orContinuous 415 , 60Hz : 220 or 440 (Dual Voltage)
Mitsubishi 6D24-TLE2B Komatsu SAA6D125E-2-B Direct Injection,Turbo charged,Intercooled
Fuel Tank Oil Capacity Lublicating Capacity LL Fuel Consumption(50/75%Load) L/hr Cooling Water Capacity L
Overall Height Length Overall Overall Net Dry Width Mass
SDG220S -3A6 60 220 60 220
Mitsubishi 6D24-TLE2B
Engine No.Diesel of Cylinder Make and Model Type(4Cycle,Water-Cooled)
Total Displacement Speed Rated Output Fuel
50 200 50 200
SDG500S
SDG400S
-3A6
%
Exciting DieselMethod Engine No. Phase Makeofand Model
No. ofDisplacement Cylinder Total (4Cycle,Water-Cooled) Type Rated Output
SDG300S
-3A6
SPECIFICATIONS
65
65
Sound power level in decibels dB 94 For other voltages than above-mentioned ones, contact us. Sound (A) machine 65and at no load65 dBfrom 7mpressure in four level directions For other voltages than above-mentioned ones, contact us. 7m in four directions from machine and at no load
66 66
98
69
67
69
67
99
70
67
70
67
99
70 70 79
Shop online at www.bluedm.com.au Address: 6-8 Hodgson Way, Kewdale, WA 6105 Open: Mon - Fri 8am - 4:30pm Sat 8am - 12pm Email:
[email protected] Phone: 1300 998 647
x
treme
Diesel Generators
SAFETY ISO9001 : JQA-0581 ISO14001 : JQA-EM4670
Operate safely in accordance with proper operation manual. To prevent trouble and accidents, perform daily and preventive maintenance checks without fail.