TYPE
QTY
MANUFACTURER
CATALOG #
L1
24
SELUX
M1DI-2T8-OD-XX-C-004-WH-277V-DM-CN16001-4'
L4
4
SELUX
M10-1T8-OD-SF1-004-WH-277V-1FW-4'
L5
4
FOCAL POINT
FSM6L-FL-625LF-1C-277V-LD1-G3-WH-8'
L5A
12
FOCAL POINT
FSM6L-FL-625LF-1C-277V-LD1-G3-WH-6'
L6A
2
PEERLESS
NRW9-1-54T5H0-WHR-FST-4FT-R4-277V-GEB10-SCT-L/LP-C041
L8
30
FOCAL POINT
FEQ-14-B-2T8-D7-277V-ST-G3-WH
P1
10
RICH BRILLIANT LTG
DELTA-DE-I-FINISH-120V
P2
6
RICH BRILLIANT LTG
DELTA-DE-IV-FINISH-120V
P3
9
RICH BRILLIANT LTG
DELTA-DE-VII-FINISH-120V
P4
13
FABBIAN
F07-A05-A-01
P5
5
FABBIAN
F07-A07-A-01
P6
1
BIRCHWOOD
ERI-LED-325S-SLO-****-F-LSFM-12'X16'-SC-UNV-EB-CSS-36-X-STD-X
P7
5
ARTEMIDE
EMPATIA-16-SUSPENSION
P8
2
FINELITE
HP4-WW-D-K-8'-SO-3500K-277V-FA/FM-X-X
P8A
1
FINELITE
HP4-WW-D-K-4'-SO-3500K-277V-FA/FM-X-X
R1
33
LITHONIA
EVO-35/20-4AR-WD-LSS-MVOLT-EZ1
R2
9
LITHONIA
EVO-WW-35/20-4AR-WD-LSS-MVOLT-EZ1
R3
2
AXIS
DIA-22-VL-T5-2-W-UNV-ERS-1-TB15
S2
2
BARTCO
BDS850-32/4-UNV
S4-150'
1
AION
8924-27-LE
S4-225'
1
AION
8924-27-LE
S5-15'
2
AION
8924-27-LE
S4/S5
27
AION
AC-A24
S4/S5
27
AION
D100-DC-24
L9
1
FINELITE
HP4-WW-D-K-8'-SO-3500K-277V-X-X-X
L9A
1
FINELITE
HP4-WW-D-K-4'-SO-3500K-277V-X-X-X
OSC1
6
GREENGATE
OAC-DT-1000-R/SP20-MV
OSC2
7
GREENGATE
OAC-DT-0501-R/SP20-MV
OSW1
9
GREENGATE
ONW-D-1001-MV-W
OSW2
13
GREENGATE
VNW-D-1001-MV-W
DIM
14
GREENGATE
SF10-PW
EM
1
GREENGATE
CEPC-1-D
EM
1
GREENGATE
RRU-1-120
LVS
7
GREENGATE
GMDS-W
LCP
9
COOPER
LK8
EBR
5
BODINE
GTD20A
Submitted by Reflex Lighting Group, Inc,
Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY
Catalog Number: SF10P-W
Type:
Notes: QUOTING (1) FOR SINGLE AND (2) FOR 3-WAY DIMMING
SD BOST16-86147
Greengate
Technical Data
0-10V Slide Dimmer Wallstation Catalog#
Prepared by
Project
Date
Comments
Type
Overview The 0-10 Volt Slide Dimmer provides full-range classic linear-slide dimming for 0-10V compatible dimmable light sources. These units are ideal for light commercial applications and are compatible with decorator style devices and wallplates. The preset “ON/OFF” switch automatically returns controlled light(s) to a preset level without disturbing the brightness level. The device is designed for both Single-pole (one location) and 3-way (multi-location) applications.
Features Preset feature allows user to return to previous light level when turning lights ON Integrated full-slide control for easy, precise operation Can be wired as Single-pole or 3-way Neutral is not required for installation of device Adjustable high-level trim setting for optimal lamp compatibility
DIMMERS 6B28
Submitted by Reflex Lighting Group, Inc,
Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY
Catalog Number: SF10P-W Notes: QUOTING (1) FOR SINGLE AND (2) FOR 3-WAY DIMMING
Specifications Switch Type Dimming Control
Single-pole and 3-way 0-10 VDC: 200mA Sink Sink Dimming
Electrical Ratings
120 VAC: Max. Load: 10 amps, 1200W, 60 Hz 277 VAC: Max Load: 6 amps, 1660W, 60 Hz Full-range, continuously variable dimming Adjustable High-level trim setting
Light Intensity Control Power Failure Memory Wiring Type
Light returns to same level prior to power interruption Back & side wiring terminals; 12-14 AWG (Copper wire) 0-10V wire leads; 16 AWG Meets UL 94 requirements, V2 rated -4°F to 158°F (-20°C to 70°C)
Flammability Temperature
Wiring Diagrams FIGURE 1: SINGLE-POLE WIRING DIAGRAM Green or Bare Black Thumbwheel
TOP
BK VT
Hot
YL Line 120 VAC - 60 Hz
Gray
Violet
Black Slider
GY
LOAD
White
FIGURE 2: 3-WAY WIRING DIAGRAM
Neutral
*
Black Thumbwheel
Green or Bare
TOP
Gray
VT Violet
SD BOST16-86147
0-10V Slide Dimmer Wallstation
December 2015
BK
YL
3-WAY SWITCH
DIMMER
YL
Tag BK
GY
Travellers
YL
Black YL
Hot
Slider Line 120 VAC - 60 Hz
LOAD White
*Can be installed on load or line side in 3-way applications Visit our website for additional wiring details at www.eaton.com/lightingsystems
2
Type:
www.eaton.com/lightingsystems
Neutral
Submitted by Reflex Lighting Group, Inc,
Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY
Catalog Number: SF10P-W
Type:
Notes: QUOTING (1) FOR SINGLE AND (2) FOR 3-WAY DIMMING
SD BOST16-86147
0-10V Slide Dimmer Wallstation
December 2015
Ordering *Wallplate not included This is an accessory for the Greengate Lighting Control System. When ordering, specify the 0-10V slide dimming wallstation as a separate system accessory. Catalog #
Description
SF10P-LA SF10P-BK SF10P-GY SF10P-V SF10P-W
Dimmer Dimmer Dimmer Dimmer Dimmer
Slider Slider Slider Slider Slider
Colors
0-10V, 0-10V, 0-10V, 0-10V, 0-10V,
120/277 VAC 120/277 VAC 120/277 VAC 120/277 VAC 120/277 VAC
Light Almond Black Gray Ivory White
* Refer to Screwless Wallplate Spec Sheet for ordering information at www.eaton.com/lightingsystems. NNote: Custom engraving is not available on 0-10V dimming wallstations.
Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Lighting systems 203 Cooper Circle Peachtree City, GA 30269 www.eaton.com/lightingsystems © 2015 Eaton All Rights Reserved Printed in USA Publication No. TD503061EN December 8, 2015
Eaton is a registered trademark. All other trademarks are property of their respective owners.
Submitted by Reflex Lighting Group, Inc,
Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY
Technical Data
Catalog Number: CEPC-1-D
Type:
EM
Notes:
BOST16-86147
Effective September 30, 2014
CEPC – Emergency Power Control Catalog#
Prepared by
Project
Date
Comments
Type
CEPC-1
CEPC-D-F-S-120
Overview The Eaton's Cooper Controls Emergency Power Control (CEPC) device allows the control of emergency lighting in iLumin architectural dimming systems.
Submitted by Reflex Lighting Group, Inc,
Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY
Catalog Number: CEPC-1-D Notes:
CEPC – Emergency Power Control
September 2014
General
Electrical Data
Mechanical:
Mounting:
Environment: Interfacing:
Eliminates energy waste by allowing emergency lighting to be switched and dimmed Fail safe operation Visible emergency power LED Visible regular power LED Integral test switch Senses local circuit power loss UL 924 listed, meets NEC, OSHA and NFPA safety codes Connections: Normal Power Sensing/Control: 120V or 277V Emergency Power: 120V or 277V Load Ratings: 20A Ballast Load Rating 1800W Incandescent Load Rating at 120V 1500W Incandescent Load Rating at 277V (CEPC-1 only) Size: CEPC-1 Body Size: 2-7/8” x 1-3/4” x 1-3/4” Flushmount size: 4-3/4”x2-3/4”x 1/4” CEPC-D-F-S-* Surface mount size: 6”x6”x2-1/4” CEPC-1 mounts to a 4-11/16” Junction box with single gang plater ring UL94-5VA Rated Plastic Color: CEPC-1 = White, CEPC-D-F-S-* = Black Weight: CEPC-1 = 8oz, CEPC-D-F-S-* = 16oz Ambient Temp Rating: 32°F - 140°F (0°C - 60°C) Compatibility: CEPC-1: iLumin SC-RP, SC-RPB and Greengate Occupancy Sensors CEPC-D-F-S-*: iLumin SC-UN, SC-UN-FT
Standards
2
www.coopercontrol.com
EM BOST16-86147
Technical Data
Specifications
Type:
Operation The CEPC senses a local single normal power circuit. As long as normal power is present the CEPC permits normal and emergency switching and dimming of the lighting load from the iLumin architectural dimming system. If normal power is lost for any reason, the CEPC will force the connected emergency fixtures to full ON. The CEPC can be wired as either a control device along with a relay panel and occupancy sensor, or as a shunt to bypass line voltage switching devices when normal power fails. The CEPC-D-F-S is a universally compatible device that allows control of 2, 3, and 4-wire emergency dimming loads. When normal power is lost the CEPC-D-F-S will force the emergency fixtures to the full bright condition. Both CEPC models include a test switch feature for verifying proper functionality. In addition the CEPC-1 model also provides an automatic test feature. Under normal operation, when the controlled load is turned OFF, the emergency lighting will remain on an additional 2.5 seconds, providing safety and convenience while leaving the area and eliminating the need of special equipment to test the emergency control of the device.
Installation The CEPC can be installed down line of the iLumin panels. The CEPC should be located next to the emergency fixture it is controlling.
Submitted by Reflex Lighting Group, Inc,
Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY
Catalog Number: CEPC-1-D
Type:
EM
Notes:
BOST16-86147
Technical Data
CEPC – Emergency Power Control
September 2014
Wiring Diagram Wiring Diagram for 3-Wire Dimming Loads
CEPC-1-D
Emergency Power
3 4
20A
Test
Emergency Panel
5 6 7
8 9 10
Test
7 EM Neutral
20A
Emergency Lighting Load
Test
Emergency Panel
Emergency Lighting Load
6 EM Load RED
Test
(Violet 0-10V)
Utility Power
Blue
X1 X2
(Violet 0-10V)
1 2
3
Utility Power
Emergency Power
5 EM Hot
1 or 2 4
CEPC-D-F-S
Regular Neutral
0-10V Gray wire
Regular Line Hot (Sensing Circuit)
iLumin SC-UN Power Card Load
Hot Switched Hot Dimmed Hot
Line
CK4A or Room Controller Relay
Neutral
3-Wire Dimming
CEPC-D-F-S CEPC-D-F-S Wire## Wire
3 - Wire Dimming
VIOGRY 1 1
Description Description
iLumin Connection Connection iLumin
4-Wire Dimming
1
1
Regular HotHot Regular
iLumin Power CardCard (L) iLumin Power
(L)
2
2
Regular Neutral Regular Neutral
iLumin Power CardCard (N) iLumin Power
(N)
3
3
Emergency HotHot Emergency
4
4
Emergency Neutral
5 6 7 8 9
CK4A or Room Controller 0-10V outputs
Emergency Neutral
CEPC-1-D Wire #
Color
Description
iLumin Connection
1
Black
Regular Hot (120V)
Constant Hot and Relay Line
2
Orange
Regular Hot (277V)
Constant Hot and Relay Line Relay Load
5
Switched Hot
iLumin Power Card (S)
6
Dimmed Hot
iLumin Power Card (D)
3
Red
Switched Hot
7
Regular Neutral
iLumin Power Card (N)
4
White
Regular Neutral
8
To Load Hot
5
blue
Emergency Hot
6
Yellow
Emergency Load Hot
7
White/Blue
Emergency Neutral
Switched Hot
iLumin Power Card (S)
Dimmed Hot
iLumin Power Card (D)
Regular Neutral
iLumin Power Card (N)
9
Load Hot Hot ToTo Load Dimmed
10
Load Dimmed Hot ToTo Load Neutral
10 X1
ToNot Load Do CutNeutral
X1 X2
Do Not Do Not CutCut
Blue
Dimmer Violet (0-10V +)
Do Not Cut
Red
To Load Violet (0-10V +)
Black
Cap Off
X2
Panel Dimmer Output Violet
Wiring Diagram for 2-Wire Dimming Loads CEPC-D-F-S
Emergency Panel
5 6 7
Test
Emergency Lighting Load
X1 X2
Test
Emergency Panel
Yellow
Red
iLumin SC-UN Power Card
Switchleg
Regular Line Hot (iLumin SC-RP transformer power) (or other constant hot circuit)
Load
20A
Neutral
CEPC-D-F-S CEPC-D-F-S # Wire Wire #
Regular Neutral (iLumin SC-RP Neutral wire)
iLumin SC-RP Relay Card
Hot Switched Hot Dimmed Hot
2-Wire Dimming 2 - Wire Dimming
Emergency Lighting Load
Blue/ White
Test
Utility Power
1 2
Utility Power
CEPC Emergency Power
Blue Blue/ White
20A
White
Test
8 9 10
Black/ Orange
20A
Wiring Diagram for 2-Wire Non Dimmed Loads
Emergency Power
3 4
Line
Normal Panel
Description
iLumin Connection
Description
iLumin Connection
2 - Wire Non Dimmed 2-Wire Non Dimmed
1 1 2 2
Regular Hot Regular Hot
iLuminCard Power iLumin Power (L) Card (L)
CEPCCEPC Wire #
Description
Regular Regular Neutral Neutral
iLuminCard Power iLumin Power (N) Card (N)
Blue
Emergency Hot
3 3
Emergency Hot Emergency Hot
Yellow
Emergency Switchleg
4 4
Emergency Emergency Neutral Neutral
Blue/White
Emergency Neutral
5 5
Dimming Hot Dimming Hot
6 6
Not Used Not Used
Black/Orange Hot(Sensing) (Sensing) Regular Hot Black/Orange Regular
Transformer Power (or Transformer Power other constant hot circuit
7 7
Regular Regular Neutral Neutral
Red
Switchleg
Relay Load Terminal Block
8 8 9
Regular Neutral Regular Neutral
Transformer Neutral Wire Transformer Neutral wire
Not Used
9
To LoadTo Hot Load Hot
10
To Load Neutral Do Not Cut
X2
Do Not Cut
X1 X2
Blue
Yellow
iLuminCard Power iLumin Power (D) Card (D) iLumin Power (N) Card (N) iLuminCard Power
Blue/White
Red
White White
Description
iLumin Connection
iLumin Connection
Emergency Hot
Emergency Switchleg
Emergency Neutral
Switchleg
(or other constant hot circuit)
Relay Load Terminal Block
Not Used
X1
10
Wire #
To Load Neutral Do Not Cut Do Not Cut
www.coopercontrol.com
3
Submitted by Reflex Lighting Group, Inc,
Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY
Catalog Number: CEPC-1-D
Type:
EM
Notes:
BOST16-86147
Technical Data
CEPC – Emergency Power Control
September 2014
Ordering Catalog #
Descriptoin
Rating
CEPC-1 CEPC-D-F-S-120 CEPC-D-F-S-277
Emergency Power Control 120V/277V Emergency Power Control 120V Emergency Power Control 277V
120V or 277V (Switching) 120V (2-wire, 3-wire, 4-wire dimming loads) 277V (2-wire, 3-wire, 4-wire dimming loads)
CEPC-1-D
Emergency Power Control 120V/277V 0-10V
120V or 277V (0-10 dimming loads)
CEPC-1-CUL
Emergency Power Control for Canada 120V/277V
120V or 277V (Switching)
CEPC-D-F-S-120V-CUL
Emergency Power Control for Canada 120V
120V (2-wire, 3-wire, 4-wire dimming loads)
CEPC-D-F-S-277V-CUL
Emergency Power Control for Canada 277V
277V (2-wire, 3-wire, 4-wire dimming loads)
CEPC-1-D-CUL
Emergency Power Control for Canada 120V/277V 0-10V
120V or 277V (0-10 dimming loads)
Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton’s Cooper Controls Business 203 Cooper Circle Peachtree City, GA 30269 coopercontrol.com © 2014 Eaton All Rights Reserved Printed in USA Publication No. ACC140950 September 30, 2014
Eaton is a registered trademark. All other trademarks are property of their respective owners.
Submitted by Reflex Lighting Group, Inc,
Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY
Catalog Number: RRU-1-120
Type:
EM
Notes:
BOST16-86147
Greengate
Technical Data
RRU-1 – UL 924 Remote Relay Unit Catalog#
Prepared by
Project
Date
Comments
Type
Overview The Remote Relay Unit (RRU-1) is available in 120 VAC and 277 VAC input voltage configurations. The RRU-1 is designed to force all outputs in the lighting control panel to an emergency scene regardless of the control panel’s programmed output status. This allows the override of outputs during loss of normal (grid) power to allow an alternate power source to drive the lighting loads (Once the RRU-1 senses the normal power returning, the control panel will return to the normal programmed operating mode).
Features UL 924 Listed Accessory Detects loss of normal power and automatically sends signal to lighting control panel Allows Greengate panels to be listed as UL 924 when RRU-1 is connected
Submitted by Reflex Lighting Group, Inc,
Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY
Catalog Number: RRU-1-120
Type:
EM
Notes:
BOST16-86147
RRU-1 – UL 924 Remote Relay Unit July 2015
Features General Electrical Data Mechanical Data Compatibility Standards
Operation UL 924 Listed Connects to normal power Lighting Control Panels must be fed from alternate power ControlKeeper M, ControlKeeper MB UL Approved UL 924 Listed
The RRU-1 provides a dry contact closure to the ControlKeeper M and MB panels when normal (grid) power is lost. This contact closure forces a hardware override of all relays in the enclosure to the ON state. This override condition takes priority over any relay commands from the system controller and will remain in effect until the contact closure from the RRU-1 is opened.
Installation The RRU-1 can be installed next to the lighting control panel enclosure.
2
www.eaton.com/lightingsystems
Submitted by Reflex Lighting Group, Inc,
Job Name: CAMBRIDGE CONSULTANTS RELOCATION FIFTH FLOOR Architect: Sasaki Associates (Watertown) Distributor: INDEPENDENT ELECTRIC SUPPLY
Catalog Number: RRU-1-120 Notes:
Type:
EM BOST16-86147
RRU-1 – UL 924 Remote Relay Unit July 2015
Wiring Diagram +
SH
RS485
RS485
MOR/LRM
Off
R35
The RRU-1 needs to provide a dry contact maintained closure to the On and +24 terminals on the ControlKeeper M motherboard MOR connector.
On
+24V
CAN-H
232 OPT
+24
ON
+24
MOR/RIM OFF
CAN-L
SHIELD
GND
USB USB HOST DEVICE
TB2
TO CCM
RS-232
For Emergency panel configurations, ensure the ControlKeeper M lighting control panel is fed from an emergency power source.
ETHERNET
+
-
J14
-
SH
CCM PWR
NET-RX
LED7
DISPLAY
ALL-OFF ALL-ON
NET NET HEART TX
LED6
LEFT RELAYS
1
RIGHT RELAYS
J9
S1
1
RESET A
J11
B
C
1
J7
C67
U35
J6
U37 SW2
SW4
SW3
1
SW6
MOR/LRM
D U34
SW5
A
B
HEART BEAT U32
RS232 Boot Mode
NET ADDRESS
+5
R25
On
C158A
PG
GND
8 16 32 64 128
+24
4
GND
J15
2
+24
LED11
SCM PWR
C149
1
Off
SW1
5001-000006-05
To override On: Connect dry contact between the On terminal and the +24 VDC terminal. When contact closes, all relays are forced ON. Contacts within the RRU-1 will automatically close when normal power is lost
Red (14 AWG) NC
Black (14 AWG)
C
SPST Relay
C Neutral = White (16 AWG)
Hot 120 VAC = Black Hot 277 VAC = Orange
To Normal Power Source (16 AWG) To Normal Power Circuit
Ordering This is an accessory for the ControlKeeper M and ControlKeeper MB lighting control panels. When ordering, specify the RRU-1 as a separate system accessory. Catalog #
Descriptoin
Rating
RRU-1-120V RRU-1-277V
UL924 Remote Relay Unit UL924 Remote Relay Unit
120 VAC 277 VAC
Note: Note: for 347 VAC Applications please see Model LRM-347
Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Lighting systems 203 Cooper Circle Peachtree City, GA 30269 www.eaton.com/lightingsystems © 2015 Eaton All Rights Reserved Printed in USA Publication No. TD503029EN July 27, 2015
Eaton is a registered trademark. All other trademarks are property of their respective owners.
In cooperation with: LVS,Inc.