GB GE/FO-130906
EMERGENCY AUTOMATIC PANELS FOR GENSET UNITS FITTING A DIESEL OR GASOLINE ENGINE
32 Three-phase 58 Single-phase
LEM-430/45
45
LEM-430/60
60
COMPLETE WITH DISPLAY TO SHOW: • useful signals for generator set management. 8 instruments: - mains voltmeter - generator voltmeter - generator ammeter (On request) - generator frequency meter - total hour meter - partial hour meter - battery voltmeter - fuel level indicator
Threephase
LEM-435/32
Amp (Ac1)
SIMULTANEOUS READING OF 3 INSTRUMENTS
TYPE
• REMOTE SWITCHING MAINS/GENSET • SINGLE-PHASE VOLTMETRIC MAINS/GENERATOR CONTROL • AUTOMATIC BATTERY CHARGING (1,5A) • AUTOMATIC SUPERVISION OF FAULTS • EJP FUNCTION • GLOW PLUGS CONTROL • STARTER CONTROL • REMOTE COMMANDS WITH CONTACTS (STARTUP - TEST - STOP) • PROGRAMMING OF PARAMETERS MADE EASY BY DIP SWITCHES • AVAILABLE INPUT FOR ANOMALY • CLOCK FOR PROGRAMMING THE START UP OR STOPPING OF THE GENSET • PROGRAMMABLE WEEKLY SELFTEST ON REQUEST • GENERATOR AMMETER • MAINS THREE-PHASE VOLTMETRIC CONTROL • EMERGENCY BUTTON • KEY FOR EMERGENCY MANUAL STARTUP • GENERATOR OVERLOAD SWITCH
®
• PRE-WIRED MALE CONNECTOR
Via Naviglio Alto,24/A 43100 PARMA (ITALY) Tel. 0521 772021 Fax 0521 270218 www.elcos.it e-mail:
[email protected] BRIEF INSTRUCTIONS
REMOTE CONTROLS INDICATION ON THE DESCRIPTION DISPLAY STARTING START STOPPING STOP START EJP EJP STARTING EJP SWITCHING EJP CONSENT CALL FROM EXTERNAL VOLTMETRIC RELAY
THE FUEL LEVEL INDICATOR IS DISPLAYED
TOTAL HOURTOTALE METER CONTAORE
PARTIAL HOUR METER. SHOWS HOURS OF OPERATION SINCE THE LAST TIME THE GENERATOR SET WAS SWITCHED ON.
THE DISPLAY SHOWS CLOCK FOR PROGRAMMING THE START UP OR STOPPING OF THE GENSET
THE ENGINE COOLING IS DISPLAYED
BATTERY CHARGER IN OPERATION
PUSH BRIEFLY TO SHOW THE INSTRUMENTS, HOLD DOWN TO VERIFY THE LED TEST OR THE GENERAL ALARMS SILENCING AND TO VIEW THE HISTORICAL RECORD
®
THE DISPLAY SHOWS: AUT
• VOLTMETER • MAINS/GENSET AMMETER • GENSET FREQUENCYMETER
OFF
MAN
TEST
%START VOLT AMP HZ
MAINS GENERATOR BATTERY
h
STOP
h
!
%
A1
EMERGENCY STOP
AVAILABLE FAULT
OFF
THE GLOW PLUGS PREHEATING IS DISPLAYED
AUT
TEST
STARTING FAILURE ALARM
MAN
THE DISPLAY SHOWS: THE TOTAL OPERATING HOURS AND THE GENSET FREQUENCY
STOPPAGE DUE TO OVERFREQUENCY
ALARM DUE TO NO FUEL
START
RESET
STOPPAGE DUE TO: • BELT BREAKAGE • BATTERY CHARGING FAILURE
STOP
www.elcos.it
STOPPAGE DUE TO: INSUFFICIENT OIL PRESSURE
USER IS CONNECTED TO MAINS
MAINS VOLTAGE IS PRESENT
CUMULATIVE ALARM
PRESS TO SELECT THE FUNCTIONS OF: • AUT OFF • OFF AUT MAN TEST • MAN • TEST
KEY ENABLED WHEN THE CONTROL PANEL IS IN MANUAL OPERATION, PRESS TO DIVERT THE MAINS TO THE POWER USERS, OR TO THE GENERATOR WHEN THE ENGINE IS RUNNING
PRESS TO RESET, THIS OPERATION ENABLES ALL THE BLOCKED FUNCTIONS
INSTRUMENTS
DIMENSIONS
PUSH TO START THE ENGINE WHEN THE CONTROL PANEL IS IN MANUAL FUNCTION
ENGINE IS RUNNING
THE GENERATOR IS ON: LED ON GENERATOR UNDER-VOLTAGE: FLASHING LED (A FLASH THEN A PAUSE) GENERATOR OVER-VOLTAGE: FLASHING LED (TWO FLASHES THEN A PAUSE)
PUSH TO STOP THE ENGINE WHEN THE CONTROL PANEL IS IN MANUAL FUNCTION
SUPPLIED ACCESSORIES
304 284 255 200
• MAINS VOLTMETER • GENERATOR VOLTMETER
USER IS CONNECTED TO THE GENERATOR
STOPPAGE DUE TO ENGINE OVERHEATING
KIT MOUNTING BRACKET LEM
8,5
• GENERATOR AMPEREMETER (On request) • GENERATOR FREQUENCY METER • TOTAL HOUR METER
316
• BATTERY VOLTMETER
377 400 420
• PARTIAL HOUR METER
• FUEL LEVEL INDICATOR
TECHNICAL DATA -SUPPLY VOLTAGE
SIMULTANEOUS READING OF THREE INSTRUMENTS
-DEGREE OF PROTECTION
ANOMALY HISTORICAL RECORD (Including data from the last 100 anomalies)
255
-WALLINSTALLATION
12 VDC OR 24 VDC
IP40
184