Evaporators

Report 16 Downloads 81 Views
Evaporators Ni Evaporator 11 to 96 Needles These systems have has a flow meter attached to the side for controlling the gas flow to the equalizer manifold giving equal gas flow to each well. Needle height is easily adjustable to enable most sizes and capacities of microplates 

Low cost solution for the concentration, 96 well versions available



Each SS Needle delivers an equal flow of nitrogen or other gas.



Gently speeds evaporation of excess liquid



Gas flow: 1 to 100ml/needle



Size: 7"w x 5 1/2"d x 7 1/2" h



Body constructed of nylon and can be sterilized by autoclaving

Catalog Number

Description

Max pressure

99A EV11

Stand alone Evaporator 11 position with stand and flowmeter

1.4 bar

099A EV15

Stand alone Evaporator 15 position with stand and flowmeter

1.4 bar

099A EV20

Stand alone Evaporator 20 position with stand and flowmeter

1.4 bar

099A EV24

Stand alone Evaporator 24 position with stand and flowmeter

1.4 bar

099A EV48

Stand alone Evaporator 48 position with stand and flowmeter

1.4 bar

099A EV8

Stand alone Evaporator 8 position for 40-60 ml tubes, with stand and flowmeter

1.4 bar

099A EV96

Stand alone 96 well evaporator with stand and flowmeter

1.4 bar

Nitrogen Evaporator Low cost solution for the concentration 8 – 384 wells extractions and reactions



Each SS Needle delivers an equal flow of nitrogen or other gas



Gently speeds evaporation of excess liquid



Heats to 100°C for even faster drying times.



Digital temperature control.



Gas flow: 1 to 100ml/needle



Electrical Rating: 2.0A 50/60Hz



Electrical: on/off power switch, fuse protection, 3 wire cord with molded plug



Control Type: PID parameters with auto tune, 4 Digit LED display



Accuracy: - 0.25% of span



Size: 7"w x 5.1/2"d x 7 1/2"H



Control Size: 5.1/2"w x 7 1/2"d x 2 1/4"h



Body is constructed of nylon and can be sterilized by autoclaving

Fine needle valve controls the total flow to the equalizer manifold that gives equal gas flow to each well. Each well has consistent evaporation. Needle height is easily adjustable to enable most sizes and capacities of microplates. Catalog Number

Voltage

Description

Max pressure

Heated single block 20 well evaporator system for 15-16mm tubes, 099A EV2024STCE

CE-240

includes block, also heats manifold gas, 15ga needles

1.4 bar

Heated single block 24 well evaporator system for 12mm tubes, 099A EV2424STCE

CE-240

includes block, also heats manifold gas, 15 ga needles

1.4 bar

384 well evaporator system, includes block and also heats manifold 099A EV38424STCE

CE-240

gas, 15ga needles

1.4 bar

Heated single block 8 well evpaorator system for 40-60 ml EPA vials, 099A EV824STCE

CE-240

includes block, also heats manifold gas, 15ga needles

1.4 bar

Heated single block 96 well evaporator system for standard well 099A EV9624STCE

CE-240

plates, also heats manifold gas, 15ga needles

Aluminum Blocks Catalog Number

Description

R34 516

Holds 8 EPA vials

R34 561

Holds 24 (15mm x 45mm) vials

R34 562

Holds 24 (12mm x 32mm) vials

R34 563

Holds 20 (15mm x 16mm) vials

1.4 bar

FlexiVap Lab Evaporator 

One manifold suits all standard size vials



Easy closure of any manifold position



Reduced nitrogen consumption



Complete even flow rates to all ports



Cost effective compared with existing models currently on the market

They are low cost, small footprint instruments used to concentrate chemical and biochemical solutions for further analysis, or evaporate to dryness for further reactions. What makes this system unique is the ability to open or close each position by turning the knobs on the manifold. Catalog Number

Description

Voltage

Max pressure

Notes

109A YH-1-24

FlexiVap Work Station with heating for small insert, 24 positions w/flow meter

240 1)

3.5 bar

Does not include insert for vials, must be ordered separately

109A YH-1

FlexiVap Work Station, no heating for small insert, 24 position w/flow meter

Non Heated

3.5 bar

does not include insert for vials, must be ordered separately

109A YH-2

FlexiVap Work Station, no heating for larger insert, 48 positions w/flow meter

Non Heated

3.5 bar

does not include insert for vials, must be ordered separately

1)

240 volt system come with the CEE/7 cord and CE compliant Catalog Number

Description

109A YH-2412

Aluminum insert block with 24 positions for up to 12mm vials (use with 109A YH-1, 109A YH-1-24 small systems)

109A YH-2416

Aluminum insert block with 24 positions for 15mm to 16mm vials ( use with 109A YH-1, 109A YH-1-24 small systems)

109A YH-2416-15

Aluminum insert block with 24 positions for 15ml Centrifuge tubes (use with 109A YH-1, 109A YH-124 small systems)

109A YH-2428

Aluminum insert block with 12 positions for up to 28mm vials, EPA (use with 109A YH-1, 109A YH-124 small systems)

109A YH-2429-50

Aluminum insert block with 12 positions for 50ml Centrifuge tubes (use with 109A YH-1, 109A YH-124 small systems)

109A YH-4812

Large Aluminum insert block with 48 positions for up to 12mm vials (use with 109A YH-2)

109A YH-4815

Aluminum insert block with 48 positions for up to 15mm to 16mm vials (use with 109A YH-2)

109A YH-4816-15

Aluminum insert block with 48 positions for 15ml centrifuge tubes ( use with 109A YH-2)

109A YH-4828

Aluminum insert block with 24 positions for up to 28mm vials, EPA (use with 109A YH-2 large systems)

109A YH-4829-50

Aluminum insert block with 24 positions for 50ml Centrifuge tubes (use with 109A YH-2 large systems)

Vacuum manifold built on kit to retro fit onto our YH-1 and YH-2 systems for capture of solvent vapors. Catalog Number

Description

109A VM-1-12

Vacuum manifold bolt on kit for YH-1 systems, 12 positions

109A VM-1-24

Vacuum manifold bolt on kit for YH-1 systems, 24 positions

109A VM-2-24

Vacuum manifold bolt on kit for YH-2 systems, 24 positions

109A VM-2-48

Vacuum manifold bolt on kit for YH-2 systems, 48 positions

FlexiVap w/ Vacuum Manifold The FlexiVap™ Work Station with Vacuum Manifold is the newest addition to our line of analytical nitrogen/air evaporators which allows for the capturing of solvent vapors. The key advantages are: 

One manifold suits many standard size vials for a totally sealed system



Easy closure of any manifold position (Nitrogen flow)



Reduced nitrogen consumption



Complete even flow rates in all ports



Vacuum gauge and regulator



Cost effective compared with existing models on the market

They are low cost, small footprint instruments used to concentrate chemical and biochemical solutions for further analysis, or evaporate to dryness for further reactions. What makes these systems unique is the ability to open or close each position by turning the manifold knobs and also the rack and pinion precision lab stand. Digital temperature control to 100°C is available on certain models.

Catalog Number

Description

Voltage

Max pressure

109A YHV-1-1224

FlexiVap work station with heating for small insert, 12 positions with flowmeter and vacuum manifold

240

3.5 bar

109A YHV-1-2424

FlexiVap work station with heating for small insert, 24 positions with flowmeter and vacuum manifold

240

3.5 bar

109A YHV-2-2424

FlexiVap work station with heating for larger insert, 24 positions with flowmeter and vacuum manifold

240

3.5 bar

109A YHV-2-4824

FlexiVap work station with heating for larger insert, 48 positions with flowmeter and vacuum manifold

240

3.5 bar

Zipvap These systems are low cost, small footprint instruments used for solvent and water removal. All ZipVap™ evaporator systems come with aluminum chassis with on/off power switch, digital temperature control adjustable to 100˚C, aluminum heatblock chamber, aluminum insert for specific vials/tubes, polypro manifold, flow meter and gas heat exchanger on select models. Standard IEC power inlet on back with 6’ power cord. Dimensions: 9” w x 6-1/2” d x 5” t (top of heat block). Support rod that holds manifold is 7" long. The ZipVap has interchangeable aluminum insert and needle manifold and allow almost any laboratory size container to be adapted. Each spare aluminum insert and needle manifold has separate catalog numbers. Catalog Number

Voltage

109A 11-80021CE

CE-240

109A 11-80025CE

CE-240

109A 11-80081CE

CE-240

109A 11-80085CE

CE-240

109A 11-80121CE

CE-240

109A 11-80125CE

CE-240

109A 11-80201CE

CE-240

109A 11-80205CE

CE-240

109A 11-80241CE

CE-240

109A 11-80245CE

CE-240

109A 11-80481CE

CE-240

109A 11-80485CE

CE-240

109A 11-80961CE

CE-240

109A 11-80965CE

CE-240

109A 11-83841CE

CE-240

109A 11-83845CE

CE-240

Description Zipvap 2, 2position evaporator for 61 mm flask, insert heated only, gas inlet not heated, with flowmeter Zipvap 2, 2 position evaporator for 61 mm flask, insert and gas inlet heated, with flowmeter Zipvap 8, 8 position evaporator for 28 mm EPA vial, insert heated only, gas inlet not heated, with flowmeter Zipvap 8, 8 position evaporator for 28 mm EPA vial, insert and gas inlet heated, with flowmeter Zipvap 12, 12 position evaporator for 18 mm vial, insert heated only, gas inlet not heated, with flowmeter Zipvap 12, 12 position evaporator for 18mm vial, insert and gas inlet heated, with flowmeter Zipvap 20, 20 position evaporator for 15 mm vial, insert heated only, gas inlet not heated, with flowmeter Zipvap 20, 20 position evaporator for 15 mm vial, insert and gas inlet heated, with flowmeter Zipvap 24, 24 position evaporator for 15mm vial, insert heated only, gas inlet not heated, with flowmeter Zipvap 24, 24 position evaporator for 15 mm vial, insert and gas inlet heated, with flowmeter Zipzap 48, 48 position evaporator for 12mm auto sampler vial, insert heated only, gas inlet not heated, with flowmeter Zipvap 48, 48 position evaporator for 12 mm auto sampler vial, insert and gas inlet heated, with flowmeter Zipvap 96, 96 position evaporator for 96 well plate, insert heated only, gas inlet not heated, with flowmeter Zipvap 96, 96 position for 96 well plate, insert and gas inlet heated, with flowmeter Zipvap 384, 384 position evaporator for 384 well plate, insert heated only, gas inlet not heated, with flowmeter Zipvap 384, 384 position evaporator for 384 well plate, insert and gas inlet heated, with flowmeter

Max Pressure 1.4 bar 1.4 bar 1.4 bar 1.4 bar 1.4 bar 1.4 bar 1.4 bar 1.4 bar 1.4 bar 1.4 bar 1.4 bar 1.4 bar 1.4 bar 1.4 bar 1.4 bar 1.4 bar

Triple Zipvap These systems are low cost, small footprint instruments used for solvent and water removal. All ZipVap™ evaporator systems come with aluminum chassis with on/off power switch, digital temperature control adjustable to 100˚C, aluminum heat block chamber, polypro manifold with stainless steel needles, (3)flow meters with on/off switch and gas heat exchanger. Catalog Number

Voltage

Description

Max Pressure

109A 11-80333CE

CE-240

Triple Position Evaporator for (3) 96 deep well plates, gas heater and flow meter with on/off switches included

1.4 bar

The ZipVap has also interchangeable aluminum insert and needle manifold and allow almost any laboratory size container to be adapted. Each spare aluminum insert and needle manifold has separate catalog numbers.

Digital Pulse Mixer Hybrid Evaporator This system is designed to rapidly evaporate/concentrate solvents by both heating the sample bottom and the incoming nitrogen and at the same time create a pulsing vortex mixing in the samples. Each pulse creates the vortex and the process continues until the concentration level is achieved. System flexibility is greatly increased with the availability of manifolds and blocks to fit your application. The Digital Pulse Mixer/Evaporator features:  Micro-processor based control technology  Speed 150 to 1,000 rpm, speed display resolution, .1 rpm, speed setting increment: 10rpm  4-line back-lit LCD display  Built in digital timer (seconds: 1-60, minutes: 1-60, hours: 1-24)  User selectable profile (pulses-per-minute: 1-1000), Ppm-duty-cycle: 1-99%  Timer and pulse mode may be combined  Communication port (USB)  Membrane switch user interface (4-button)  Soft start/stop of motor  Optional software for real time data acquisition  Orbital offset .070"  Set point temperature for bottom blocks (120° C max.)  Flow meter located on left side of mixer  A fine needle valve for flow control is provided on each manifold  Maximum psi: 20  Electrical: on/off switch, 3 wire 6 foot long cord  Size: 12"w x 22"d x 8"h  Drive plate: 7" x 12"  Load capacity: Maximum 5 pounds

Catalog Number

Volts

Description

Watt

099A DPMES24CE

CE-240

Evap system 2 block format, without manifold

50/60Hz

A PMAN96

-

96 well polypropylene manifold w/needles

-

099A PMAN24

-

24 well polypropylene manifold w/needles

-

099A PMAN20

-

20 well polypropylene manifold w/needles

-

099A PMAN8

-

8 well polypropylene manifold w/needles

-

R34 562

-

24 well aluminum block 12mm vials

-

R34 561

-

24 well aluminum block 15mm vials

-

R34 563

-

20 well aluminum block 15 to 16mm vials

-

R34 516

-

8 well aluminum block for EPA vials

-