Certificate No: EW08
Bespoke Modular Buildings: Construction of Modular Buildings for Domestic and Disabled Purposes Description of Product Bespoke Modular Building's construction
Photo/isometric drawing provided by manufacturer
method for modular extensions for domestic and disabled purposes.
Key Factors Assessed
Mechanical Resistance & Stability - Approved Document A
Safety in case of Fire
Health, Hygiene and Environmental - Approved Document C
Safety in Use - Approved Document A
Protection against noise
Energy Economy and heat retention - Approved Document L
Durability serviceability and identification
Validity This certificate was first issued on 19th December 2012 and is valid until 19th December 2015 Issue Dated 26th January 2015
This Registered Detail relates to Bespoke Modular Building's construction method for single storey modular domestic extensions for domestic and disabled purposes. Conditions of use are highlighted in section 10 below.
The construction method is approved for single storey domestic extensions only. The following items are site specific and therefore outside the scope of this certification 1. Foundations except where swift base is used. 2. Foul drainage disposal. 3. Space heating and hot water storage and distribution. 4. Remediation of ground contamination. 5. Structural support to existing walls where openings exceed 1500mm clear. 6. Fire spread between buildings. Structural design limitations are: Urban Environment Maximum 190m above sea level Maximum basic wind speed 24m/s (as stipulated in structural calculations)
LABC consider that, Bespoke Modular Buildings: Construction of Modular Buildings for Domestic and Disabled Purposes, will meet the functional requirements of the Building Regulations (listed below) if the criteria detailed in this certificate are met;
The Building Regulations 2010 (as amended) England & Wales Regulation 7
Materials and workmanship
Note:
The products are acceptable.
AD A
Structure
Note:
Subject to limitations detailed below in Conditions section.
AD B
Fire Safety
Note:
The products can contribute to meeting this Requirement subject to limitations detailed below in Conditions section.
AD C
Resistance to Contaminants and Moisture
Note:
The products can contribute to meeting this Requirement subject to limitations detailed below in Conditions section.
AD E
Resistance to Sound
Note:
The products can contribute to meeting this Requirement subject to limitations detailed below in Conditions section.
AD F
Ventilation
Note:
The products can contribute to meeting this Requirement subject to limitations detailed below in Conditions section.
AD L
Conservation of Fuel and Power
Note:
The products can contribute to meeting this Requirement subject to limitations detailed below in Conditions section.
AD M
Access to and Use of Buildings
Note:
The products can contribute to meeting this Requirement subject to limitations detailed below in Conditions section.
AD N
Glazing Safety
Note:
The products can contribute to meeting this Requirement subject to limitations detailed below in Conditions section.
AD P
Electrical Safety - Dwellings
Note:
The products can contribute to meeting this Requirement subject to limitations detailed below in Conditions section.
The Building Regulations 2010 (as amended) England None presently
The Building Regulations 2010 (as amended) Wales None presently
The Building (Scotland) Regulations 2004 (as amended) If you would like to discuss a specific use of the product in Scotland it will require an additional assessment under the Scottish Building Regulations and accordingly you should contact the LABSS STAS Administrator at www.labss.org
LABC Warranty The use of the Construction of Modular Buildings for Domestic and Disabled Purposes System has not been assessed to meet the requirements of the LABC Warranty Technical Manual. If you would like to discuss a specific use please make an enquiry to
[email protected] Drawings: BMB3F1B, BMB3F2C, BMB3F3C, BMB3R1E, BMB3R2E, BMB3W1WE, BMB6F1A, BMB6F2A, BMB6F3A, BMB6R2E, BMB6R1D, BMB6W1E, BMBCon01F, BMBCon02C, BMB09A, BMBSD1F BBA Certificates 06/4355 AND 06/4312 Structural appraisal and calculations ref 12014-CS-01 GRP Cladding Fire Test BuildDesk UValue calculations for SIP elements April 2012 LABC system approval for Swift Base 446-3-7188 Fire Performance of SIP Panels IP21/10 Dec 2010
Bespoke Modular Buildings (company number 8730672) 14 Walton Avenue Rowley Regis West Midlands B65 0BY Tel: 01212342357 Email:
[email protected] Web: www.bespoke-mb.com