features & specifications ordering information

Report 2 Downloads 174 Views
Catalog Number

Notes

Type

FEATURES & SPECIFICATIONS INTENDED USE For use in Non-IC application with the LF6 frame-in. CONSTRUCTION Aluminum one-piece reflector. White polyester powder coat paint. White integral flange. Diffuse or specular finishes have matching integral flange. INSTALLATION Rough-ins utilize yoke for mechanical trim retention. Socket housing attaches securely to reflector. Reflectors accommodate ceilings up to 1-1/2" thick. LISTING UL listed to US and Canadian safety standards. Damp location listed.

6" Finishing Trims

F6O2 OPEN REFLECTOR Horizontal Lamp

6-5/8" (24.4)

Specifications Aperture Size (Inside diameter): 6-1/8" (15.6) Overlap Trim (Outside Diameter): 7-1/2" (19) Height: 6-5/8 (16.8)

ORDERING INFORMATION

6-1/8" (15.6) 7-1/2" (19.5) All dimensions are inches (centimeters).

For shortest lead times, configure product using standard options (shown in bold). Example: F6O2A

F6O2 Series

Finish

Options

F6O2

(blank) White A Clear difuse AZ Clear specular open

TRW White flange with anodized trims

G PR GZ WTZ

Gold diffuse Pewter Gold specular Wheat specular

Accessories

Compatibility

Order as separate catalog number.

CTR6 Oversize Trim Ring

Downlighting and Track

Used On LF6

Lamp Type Compact fluorescent

Maximum Lamp Wattage IC/Non-IC 2/26W DTT Non-IC

Sheet #: F6O2-COM

COPN-130

F6O2 Open Reflector Distribution curve

Distribution data

Output data

Coefficient of utilization

Single luminaire data 30" above floor

F6O2, (2) Philips PL-C 26W/27SH lamp, 1.0 s/mh, 3600 rated lumens, Test no. 2195072501 From 0°

cp.

Lumens

0° 5° 15° 25° 35° 45° 55° 65° 75° 85° 90°

1073 1071 980 757 495 268 159 96 48 9 0

102 275 349 311 214 145 96 51 13

Zone

Lumens %lamp

0°-30° 726 20.18 0°-40° 1037 28.81 0°-60° 1397 38.81 0°-90° 1556 43.25 90°-180° 0 0.0 0°-180° 1556 43.25* *Total Efficiency

rf 20% rc 80% 50% 30% rw 50% 30% 50% 30% 50% 30%

1 2 3 4 5 6 7 8 9 10

47 43 39 36 33 31 28 26 25 23

46 41 37 33 30 28 25 23 22 20

44 41 37 35 32 30 28 26 24 22

43 39 35 32 30 27 25 23 21 20

43 39 36 34 31 29 27 25 23 22

42 38 35 32 29 27 25 23 21 19

Initial fc Mount at beam height center

8' 10' 12' 14' 16'

35.5 19.1 11.9 8.1 5.9

50% 10% Beam angle 51.6° Beam angle 87.9° fc at fc at Beam beam Beam beam diameter edge diameter edge

5.3 17.8 7.3 9.5 9.2 5.9 11.1 4.1 13.1 2.9

10.6 14.5 18.3 22.2 26.0

3.6 1.9 1.2 .8 .6

F6O2A, (2) Philips PL-C 26W/27SH lamp, 1.2 s/mh, 3600 rated lumens, Test no. 2195110901 200 400 600 800 1000

From 0°

cp.

Lumens

0° 5° 15° 25° 35° 45° 55° 65° 75° 85° 90°

937 961 981 842 675 485 183 31 9 2 0

47 138 195 212 185 88 19 5 1

Zone

Lumens %lamp

0°-30° 737 20.48 0°-40° 1147 31.88 0°-60° 1676 46.57 0°-90° 1723 47.87 90°-180° 0 0.00 0°-180° 1723 47.87* *Total Efficiency

rf 20% rc 80% 50% 30% rw 50% 30% 50% 30% 50% 30%

1 2 3 4 5 6 7 8 9 10

52 48 44 41 38 34 31 29 26 24

51 46 42 38 34 31 28 26 23 21

49 46 42 39 36 33 30 28 26 24

48 44 40 37 34 31 28 25 23 21

48 45 41 38 35 33 30 27 25 23

47 43 40 36 33 30 27 25 22 20

Initial fc Mount at beam height center

8' 10' 12' 14' 16'

31.0 16.7 10.4 7.1 5.1

50% 10% Beam angle 58.6° Beam angle 98.8° fc at fc at Beam beam Beam beam diameter edge diameter edge

6.2 15.5 8.4 8.3 10.7 5.2 12.9 3.5 15.2 2.6

12.8 17.5 22.2 26.8 31.5

3.1 1.7 1.0 .7 .5

F6O2AZ, (2) Philips PL-C 26W/27SH lamp, 1.2 s/mh, 3600 rated lumens, Test no. 2193120701 200 400 600 800 1000

Energy

From 0°

cp.

Lumens

0° 5° 15° 25° 35° 45° 55° 65° 75° 85° 90°

887 903 960 841 666 569 144 7 1 0 0

87 269 387 424 424 162 9 2 1

Zone

Lumens %lamp

0°-30° 741 20.60 0°-40° 1165 32.36 0°-60° 1750 48.62 0°-90° 1759 48.89 90°-180° 0 0.00 0°-180° 1759 48.89* *Total Efficiency

rf rc rw

20% 80% 50% 30% 50% 30% 50% 30% 50% 30%

1 2 3 4 5 6 7 8 9 10

54 50 46 42 39 35 32 29 27 25

(Calculated in accordance with NEMA standard LE-5.)

Fixture/ Reflector LF6 DTT/F6O2 AZ LF6 DTT/F6O2 AZ LF6 DTT/F6O2 GZ LF6 DTT/F6O2 LF6 DTT/F6O2A LF6 DTT/F6O2A

LER 35.29 34.59 33.93 30.35 33.88 31.27

Annual* Lamps Lamp Ballast Input Energy Cost Lumens Factor Watts $6.80 (2) 18W DTT 2500 .95 35 $6.94 (2) 26W DTT 3600 1 51 $7.07 (2) 18W DTT 2500 .95 35 $7.91 (2) 26W DTT 3600 1 51 $7.08 (2) 26W DTT 3600 1 51 $7.68 (2)18W DTT 2500 .95 35

52 48 43 39 35 32 29 26 23 21

53 49 45 41 38 35 32 29 27 24

51 47 42 39 35 32 29 26 23 21

51 47 44 40 37 34 31 29 26 24

50 46 42 38 35 31 28 26 23 21

Initial fc Mount at beam height center

8' 10' 12' 14' 16'

29.3 15.8 9.8 6.7 4.9

50% 10% Beam angle 58.6° Beam angle 98.8° fc at fc at Beam beam Beam beam diameter edge diameter edge

6.7 14.7 9.1 7.9 11.5 4.9 13.9 3.4 16.4 2.4

13.8 18.8 23.8 28.8 33.8

2.9 1.6 1.0 .7 .5

Conversion Factor Use multiplier to determine candlepower, lumens and footcandles for gold (F6O2G) finish from F6O2A data. Gold = .90 To calculate light levels for other wattage lamps, multiply the footcandle levels by the ratio of desired-lamp lumens to displayed-lamp lumens. Example: fc level at 8' nadir for F6O2 (2)26DTT is 35.5. With (2)18DTT, fc level is 35.5 x .69 = 24.5fc.

*Comparative yearly lighting energy cost per 1000 lumens Compact Fluorescent Lamp

Lumens

Multiplier

(2)26DTT

3600

1.00

(2)18DTT

2500

0.69

(2)13DTT

1720

0.48

Lithonia Lighting

Sheet #: F6O2-COM

©2000 Acuity Brands Lighting, Inc., Rev. 6/25/07

Recessed Downlighting One Lithonia Way, Conyers, GA 30012 Phone: 800-315-4935 Fax: 770-918-1209 www.lithonia.com