GENERAL NOTES
DOOR SCHEDULE
ALL DIMENSIONS ARE TO FACE OF STUD. ALL EXTERIOR STUD WALLS TO BE 2 X 6 CONSTRUCTION, ALL INTERIOR STUD WALLS TO BE 2 X 4 U.N.O.
#
SIZE
DESCRIPTION
FINISH
HARDWARE/REMARKS
1 2 3 4 5 6 7 8 9 10 11 12 13
16 17 18
3'-0" X 8'-0" 2'-8" x 7'-0" 2'-8" x 7'-0" 2'-4" x 7'-0" 2'-8" x 7'-0" 2'-4" x 7'-0" 2'-8" X 7'-0" 2'-4" X 6'-8" 2'-0" X 7'-0" 18'-0" x 7'-0" 7'-0" x 7'-0" 2'-8" x 7'-0" 4'-0" x 7'-0" VERIFY 2'-4" x 7'-0" (2) 1'-0" x 7'-0" 3'-0" x 8'-0" VERIFY
CUSTOM METAL ENTRY DOOR SOLID CORE WOOD CUSTOM METAL DOOR SOLID CORE WOOD SOLID CORE WOOD POCKET DOOR SOLID CORE WOOD SOLID CORE WOOD DOOR SOLID CORE WOOD DOOR HOLLOW CORE METAL OVERHEAD GARAGE DOOR 2'6" FULL LITE GLASS DOOR W/ SIDELIGHT FULL LITE SINGLE ATRIUM BY PASS SLIDING DOORS (SC) BY OWNER SOLID CORE WOOD SOLID CORE WOOD FULL LITE GLASS DOOR/8'X7'6" FIXED PANEL CUSTOM ENTRY GATE
VERIFY PAINT PAINT PAINT PAINT PAINT PAINT PAINT PAINT N/A BY MANU. BY MANU. PAINT VERIFY PAINT PAINT BY MANU. VER.
3,4,9 – CUSTOM DESIGN BY ARCH. VER. ALLOWANCE 3,4,9 3,4,9 – CUSTOM DESIGN BY ARCH. VER. ALLOWANCE 3 RECESSED PULLS BOTH SIDES 1 1,2 1,2 3,4,9 11; MTL FRAME TO MATCH WDWS.;FROSTED GLASS LITES 3,4,9; SIDELIGHT IS 4'6" X 4'-0" W 3 EQ.HOR. LIGHTS; HDR. OF LIGHT TO MATCH DOOR 3,4,9–EXT. BY KAWNEER FIN. TO MATCH WDWS VERY HVY. DUTY TRACK HARDWARE HARDWARE AND MILLWORK AS REQ. 1,2 1/SHELF ON INSIDE OF DOOR (HAFELE OR EQ.) 3,4,9–EXT. BY KAWNEER; FIXED PANEL–4 EQ. HORIZ. LITES OVER 2 EQ. INSW. HOPPER COORD. DETAILS W/ ARCH.
19 20
VERIFY VERIFY
CUSTOM GATE FRAMELESS GLASS SHWR. DOOR/SIDELT.
VER. VER.
COORD. DETAILS W/ ARCH. FIELD MEASURE AS REQ.
SLOPE ALL DECK AREAS AND GARAGE TO DRAIN AWAY FROM HOUSE AS REQUIRED.
ALL WINDOW DIMENSIONS ARE TO CENTERLINE OF UNIT. HVAC ENGINEER TO VERIFY LOC. OF ALL SUPPLY & RETURN VENTS IN FIELD WITH ARCHITECT. REFER TO SPECIFICATIONS FOR MORE INFO RELATING TO SPECIFIC DESIGN REQUIREMENTS OF SYSTEM.
1/A3.2
–CONTRACTOR TO PROVIDE TILE AT ALL TUB/SHOWER SURROUNDS. SEE A4.1 FOR EXACT TILE LOCATIONS AND VERIFY W/ ARCHITECT. ARCHITECT TO SELECT TILE FOR OWNER APPROVAL. SEE SPECIFICATIONS.
VERIFY ALL APPLIANCE SELECTIONS WITH OWNER PRIOR TO ROUGH FRAME -IN. CONSULT W/ ARCH AS REQUIRED.
PUMP CIRCULATOR TO BE LOCATED IN CAVITY WALL @ ENTRY GATE WALL. VERIFY EXACT LOC. W/ ARCH.; COORD. ACCESS DOOR DETAIL W/ ARCH.; SEE A2.2 & A3.2 FOR WATER FEATURE AND DOWNSPOUT INFO. / DETAILS.
2/A3.2
–CONTRACTOR TO VERIFY NUMBER OF STEPS REQUIRED AT ALL PORCHES/WALKS IN FIELD PRIOR TO FINAL APPROVAL OF FOUNDATION LAYOUT. RISERS TO BE 6" HIGH, ALL EXT. TREADS TO BE 14" TYPICAL.
ALL STUCCO LEDGES @ ENTRY, UPPER DECK RAIL, AND COVERED PORCH SILLS TO BE WRAPPED W/ ELASTOMERIC MEMBRANE OVER GALV. FLASHING & BE SLOPED TO DRAIN. SEE A2.2
–ALL INTERIOR WALLS TO BE PTD. GYP. BD. (1/2" WALLS AND 5/8" CEILING) U.N.O.
COORDINATE DETAIL OF LOUVERED WOOD VENT SCREENS IN GARAGE W/ ARCHITECT.
NEGATIVE POND EDGE LINE OF WATER SPOUT ABOVE– SEE 2/A2.2
INTEGRAL COLOR STUCCO OVER CMU WALL. PROVIDE WATERPROOFING/ SEALANT AND OVERFLOW AS REQUIRED; COORD. DETAIL W/ ARCHITECT AS REQUIRED.
" 1/2
11'-4
9 A5.1
6" DRAIN GUTTER AND SCUPPERS – SEE 1/A3.2
DOOR SCHEDULE NOTES HARDWARE KEY:
UP
SLO 1/4" PE TO PER DRA 1'-0 IN "M IN.
SLO 1/4" PE TO PER DRA 1'-0 IN "M IN.
SLO 1/4" PE TO PER DRA 1'-0 IN "M IN.
.
10"
EQ
24'-
"
4'-0" 7'-6"
1/2
DN. 2 EQ. R.
3'-6
3'-0"
2"
2 R. & SH.
5 1/
/2" 01
10'-
1'-0"
.
H. J. S
1'-9 1/2"
EQ
AD
7'-0"
"
5'-1
2'-1
1
1"
X
9"
3
ES
3'-1
1'-0"
R. EQ.
1/2
19'-0"
.2 DN
5'-0
6'-
" 1/2 0'-6 18'-
6
0"
±
24'-
IFY VER 10"
2"
1 1/
MECH. CONCRETE
2'-0 "
ZINC TABLE TOP– SEE 10/A4.1
R
HW
A/C
115
A/C
°
7'-2
2/A3.1
" 1/2
3'-1
1"
±
EQ
.
Drawn By
4'-3 1/2 "
3'-8
3'-4 "
11
H.
ELV
/2"
Revisions
. SH
" 1/2 3'-9
7
9
J. S
SH
HIGH VENT
"
.&
'-0 " 1
/2"
91
3R
"
"
7'-0
10
1/2
EN
"
"
" 3'-8
. S Q. R TEP 5 E OD S WO
"
5
"
2'-3
LIN
3'-5
/2"
01
CONCRETE
11'-5
14 A4.1
1"
" 1/2
7'-1
LOCATION OF FRAMING FOR FUTURE 2'-8" DOOR TO BE CONCEALED W/IN WALL
STORAGE
A
3'-1
2
DN.
GALLERY
–FIRST FLOOR PLAN –DOOR SCHEDULE
"
"
5'-0
1'-2
6'-8
1'-8
8 A4.1
3/A3.2 3'-5
4
STAINED CONCRETE
Sheet
"
8'-
"
. M.C
STAINED CONCRETE G
STAINED CONCRETE
W/D
A 3'-5
FUT. SINK
3
9 A4.1
1/2
3'-0
CEDAR CLOSET
6 D A4.1
STORAGE
LOW VENT
DUMBWAITER
DN.
STAINED CONCRETE NOTE: PROVIDE STUB OUTS FOR FUTURE FIXTURES FUT. TOILET
8'-6 1/2"
TP
STAINED CONCRETE
JACUZZI PUMP ACCESS
3 A5.1
NOTE: VERIFY REQ. FOR DOG DOOR THIS AREA W/ OWNER
"
4'-9
8"
/2"
MASTER BATH
4"
2/A3.1
SH.
6 B A A4.1
/2"
2 R. & SH. C
01
0"
UP
3'-8
. S Q. R TEP 8 E OD S WO
2'-1
"
"
F.P.
MASTER BEDROOM
SHOWER 115°
"
1'-0
1 10
F
"
L.L. PINE
3/A3.2
C
NOTE: VERIFY LOC., SIZE, AND DETAIL OF HIGH AND LOW VENTS W/ ARCH.
6'-1
"
1'-5
1'-0
"
"
LIGHT BROOM FINISH CONCRETE
" 1/2
"
2'-3
ENTRY HALL
1
501 WESTLAKE DRIVE AUSTIN, TEXAS 78746
3'-1
7'-3
"
3'-0 2'-4
0"
R 1'-
3'-0
TERRACE STAINED CONCRETE
MATTHEWS RESIDENCE
ZINC TOP; 12/A4.1 SIM.
GARAGE
S
5'-0
AD
' PE
1'-0"
9 A5.1
"
3 A5.1
O
3/A3.1
1/4
. R. EQ
1'-0
TILE @ RAISED TUB AREA & SHOWER
NICHE " 3 3'- D. RA
Project
T
PLANTER
F
3/A3.2
PE
.6 DN
9 A5.1
SLOPED TUB SIDES; COORD. DET. W/ ARCH. AS REQ.
H.
ENTRY LANDING STAINED CONCRETE
4
J. S
"
1/2
'-9"
2"
Seal
3/A3.2
SLO
5'-9
METAL FENCE/GATE; COORD. DETAIL W/ ARCH.
"
"
7'-5
2'-0
1'-9"
"
" 1'-0
Street 78701 4980 4991
AD
5'-9 1/2"
S
207 West 4th Austin,Texas 512·472· Fax ·472·
R. EQ.
"
1'-0"
3'-5"
1'-0 ER
7'-8
9'-7"
WN
43'-10"
5"
15'-5 1/2"
34'-
. TYP
/O
8'-
8"
.W
LOC. OF STUB OUT FOR FUTURE OUTDOOR SHOWER FIXTURE
PER
ALK Y W CRETE ENTATINRED CON
ERS RIS AL QU 6 E 7'-8"
VER
" 2'-0
' 1/4
"
1/A3.1
PE
1/2
1'-1
0"
"
17'-
ADDITIONAL NOTES:
SLO
" 7'-8
1/2
1'-3
2" 1 1/
. TYP
2'-3
ALLOW FOR LOCKSETS, DEADBOLTS. OTHER HARDWARE TO BE IN BASE BID. DOOR HINGE FINISH TO MATCH SELECTED HARDWARE
8"
P. " TY
.2 DN
"
1/2
3'-5
HARDWARE:
ALL FULL LITE ATRIUM DOORS TO MATCH COLOR, STYLE AND FINISH, AND MANU. OF WINDOW (TEMPERED WHERE REQUIRED BY CODE). ALL PAINT GRADE INTERIOR DOORS TO BE SOLID CORE BIRCH VENEER OR APPROVED EQUAL. COORDINATE INSTALLATION OF ALL OWNER SUPPLIED DOORS/GATES W/ ARCHITECT AND VERIFY ALL DIMENSIONS ON SITE. VERIFY HARDWARE REQUIREMENTS FOR OWNER SUPPLIED DOORS WITH OWNER AND CONSULT W/ ARCHITECT. DUMBWAITER DOORS TO MATCH STYLE OF TYPICAL INTERIOR CABINETRY– VERIFY SIZE REQ. W/ MANU. SHOWER DOORS TO BE SPECIFIED BY ARCHITECT– DOORS TO BE FRAMELESS GLASS TYPE.
RETENTION POND
VERIFY LENGTH OF WALL IN FIELD W/ ARCH. AND OWNER; PROVIDE ELEC. STUB OUT FOR ADD'L. LIGHTING AS REQ.– SEE A1.3
"
7 MORTISED BALL CATCH AT HEAD AT DOUBLE DOORS 8 T-ASTRAGAL 9 THRESHOLD AND WEATHERSTRIPPING 10 SHOWER DOOR HARDWARE BY SHOWER DOOR MANUFACTURER 11 GARAGE DOOR HARDWARE AND REMOTE-CONTROLLED OPENER 12 MORTISED SLIDING JAMB BOLT
2'-0
1 PASSAGE LOCK 2 PRIVACY LOCK 3 KEYED LOCKSET 4 DEADBOLT 5 RECESSED PULL BOTH SIDES–HEAVY DUTY TRACK 6 RECESSED PULL SINGLE SIDE–HEAVY DUTY TRACK
11'-7
FIRST FLOOR PLAN
RAISED PEDESTAL FOR HVAC/HW
"
1/2
J. CORDER
22'-
1/A3.2 1/A3.1 28
'-
2 3 1/
/2"
91
2/A3.2 Date Issued
"
SCALE: 1/4" = 1'-0"
GRAPHICS KEY STUD WALL
10'-4 1/2"
18'-6"
20'-10 1/2"
28'-10 1/2"
5'-6" 39'-0 1/2"
SOUND ATTENUATING INSULATION
±14'-5" VERIFY
LINE OF FURR DOWN/CEILING ABOVE U.N.0. HOSE BIB
67'-11"
GAS OUTLET FOR F.P. IGNITE OR COOKTOP, ETC. WATER LINE FOR ICEMAKER, DISHWASHER, CLOTHES WASHER, ETC. LINE OF STUD WALLS/FRAMING OR APPLIANCES, ETC. U.N.O.
A1.1 CAUTION: DO NOT SCALE DRAWINGS
WINDOW SCHEDULE DESCRIPTION
HEADER
A B C D E F G H J K L M N
2'4" 2'4" 8'0" 9'0" 2'3" 8'0" 8'0" 9'0" 7'6" 8'0" 6'-8 1/2"–ALIGNS W/ MUNTIN OF "K" ;SILL ALIGNS W/ "K" VERIFY W/ ARCH. 9'0" 2'3" 6'6" AFF M. BATH 2'3" 2'3" 2'3" 2'4" 2'4" 5'8" VER. 10'6" 8'0" 9'0" 9'0" 8'0"
PROVIDE OVERFLOW SCUPPER @ COV'D. DECK PVC DRAIN FOR COVERED PORCH– DRAIN TO BELOW SEE 2/A2.2
1/A3.2 6'-
24'-
10"
2"
1'-2
"
1/2
2'-4
1'-0
"
"
2'-4
PAINTED STUCCO OVER ELASTOMERIC ROOFING MEMBRANE @ COV'D. PORCH SILLS– SLOPE SILLS TO DRAIN TYP.
" 1'-0
"
'-5
1
" 1'-0
0"
"
3'-0
8'-
2'-4
60
"
" 1/2
'-0 " 1
'-3
"
2'-4
1/2
"
3/A3.2
COV'D PORCH
43'-9 1/2"
6'-11 1/2"
K A
1'-10 1/2" 1'-0
1/A3.1
B
4 A4.1
STUDY
Project
11
L.L. PINE 12
"
91
/2"
2'-9 "
16'-
L A ABOVE
/2"
3"
4"
E SH
8
4'-0" 7'-6"
26'-4 1/2" SH.
4'-4 1/2" 6'-2 1/2"
3'-0"
7'-5
7 A A4.1
"
H
01
6'-5
M 1'-9
4'-3
"
" 1/2
" 1/2
Revisions
X'
3/A3.2
ZINC CAP RAIL; 12/A4.1 SIM
3'-6"
B 3 A4.1
RAISED BUTCHER BLOCK OVER DW
5'-6"
J
2 A5.1
8"
STEREO
BATH #2
L.L. PINE
3'-4 1/2"
8"
1'-6"
3" 2'-11 1/2"
SLOPE TO DRAIN; SEE STRUCTURAL
6 EQ. R.
6 1/2"
1'-9 1/2" 1'-0"
/2"
6'-10 1/2"
01
"
–SECOND FLOOR PLAN –WINDOW SCHEDULE
"
19'-0"
7'-1
1/2
5'-3
11
Sheet
STAIR HALL
Y
D
Z
Drawn By
2/A3.1
4 A3.1
1
/2"
"
5'-1
REF.
DW
B
1'-1"
4'-4
L.L. PINE
1'-1"
3 C A4.1
/2"
TILE
"
KITCHEN
3'-2
4'-0"
15 A A4.1
14
"
1/2
501 WESTLAKE DRIVE AUSTIN, TEXAS 78746
ELF SH OK BO
"
STL. HANDRAIL PER CODE; COORD. DET. W/ ARCH.
L.L. PINE
LOW
3'-1
16 4'-0"
TV/VCR
E BELOW
Z
ES
B
"
A
3/A3.2
2'-6
25°
2 A4.1
L.L. PINE SH.
BEDROOM #2 13 " 1/2
"
/2"
31
11"
3"
PANTRY
E
12'-8"
V ABOVE
17
2'-8
6'-7
"
1/2
/2"
01
5 A A4.1
HVAC
D 2 A4.1
A
2 A4.1 C
2'-8
3/A3.2
H. &S
T SE
15 4'-1
4'-1
LIVING AREA 1'-8 1/2"
DECK
DUMBWAITER
DN.
UP
3 A4.1
L.L. PINE
STONE TILE
"
2'-9
SH.
"DANCING FLAME" FIREPLACE; STAINED CONCRETE HEARTH; SEE 7/A5.1
C'
C LO
N
L.L. PINE
10 A5.1
2/A3.1
1'-0
ENTRY L.L. PINE
DINING AREA
"
PTD. STEEL HANDRAIL– SEE 9/A5.2
"
10"
3/A3.1
1/2
6'-
CL 3'-3"
C
1/2
5'-4
W
C
2 34'-
ELV
"
3 A5.1
1'-0"
3'-
8"
MATTHEWS RESIDENCE
1 A5.1
S LVE
5'-3
T 5 A5.1
1 R.
SH
3'-0
2"
7 1/
P
3" 1 3'-3
8'-
10"
5'-9 1/2"
"
13'-0"
24'-
2'-9"
15'-3 1/2"
2'-9
TILE 9'-8 1/2"
Street 78701 4980 4991
Seal
2'-4
103
2" 5 1/
/2"
207 West 4th Austin,Texas 512·472· Fax ·472·
"
18'-
8"
1'-0
3'-6" X 2'-8" 3'-6 1/2" X 2'-8 7/16" FIXED UNIT W/ TWO EQ. HORIZONTAL LIGHTS 7'-1" X 1'-6' 7'-1 1/2" X 1'-6 7/16" FIXED UNIT 3'-6" x 7'-6" 3'-6 1/2" x 7'-6 7/16" 5 EQ. HORIZ. LITES– 4 FIXED OVER 1 HOPPER 3'-0" X 4'-6" 3'-0 1/2" X 4'-6 7/16" PROJECT OUT AWNING 2'-6" X 4'-0" 3'-0 1/2" X 4'-0 7/16" 3 EQ. HORIZ. LITES– 2 FIXED OVER 1 PROJECT OUT AWNING 3'-6" X 6'-0" 3'-6 1/2" X 6'-0 7/16" 4 EQ. HORIZ. LITES – 3 FIXED OVER 1 HOPPER 8'-6" X 6'-0" 8'-6 1/2" X 6'-0 7/16" 2'0" INSWING CASEMENT/6'6" 4 EQ LITES– (3) EQ. HORIZ LITES OVER 2 EQ. HOPPER(S) 12'-0" X 1'-6" 12'-0 1/2" X 1'-6 7/16" FIXED UNIT 3'-6" X 3'-0" 3'-6 1/2" X 3'-0 7/16" PROJECT OUT AWNING 13'-0" X 5'-6" 13'-0 1/2" X 5'-6 7/16" 5'0" FIXED/5'0" (3) EQ. HORIZ. LITES OVER (1) HOPPER/3'0" (3) EQ. HORIZ. LITES OVER (1) HOPPER 3'-6" X 4'-2 1/2" 3'-6 1/2" X 4'-2 15/16" 3 EQ. HORIZ. LITES– 2 FIXED OVER 1 HOPPER 2'-6" X 5'-0" 2'-6 1/2" X 5'-0 7/16" INSWING CASEMENT 2'-0" X 1'-6" 2'-0 1/2" X 1'-6 7/16" FIXED UNIT 0 4'-6" X 5'-0" 4'-6 1/2" X 5'-0 7/16" 2 EQ. HORIZ. LITES– 2 FIXED OVER 1 HOPPER P 3'-6" X 3'-6" 3'-6 1/2" X 3'-6 7/16" INSWING HOPPER R 3'-6" X 2'-0" 3'-6 1/2" X 2'-0 7/16" FIXED S 2'-6" X 5'-0" 2'-6 1/2" X 5'-0 7/16" INSWING CASEMENT T 1'-4" X 5'-6" (VERIFY) 1'-4 1/2" X 5'-6 7/16" FIXED UNIT V 11'-0" X 2'-6" 11'-0 1/2" X 2'-6 7/16" 8'0" FIXED/3'0" FIXED; MUNTIN TO ALIGN W/ DOOR "17" BELOW W 4'-0" X 4'-8" 4'-0 1/2" X 4'-8 7/16" 3 EQ. HORIZ. LITES– 2 FIXED OVER 1 HOPPER X' 12'-0" X 1'-8"/8'-6" 12'-0 1/2" X 1'-8 7/16"/8'-6 7/16" (3) 3'0"X1'8" FIXED MULLED UNITS/3'0"X10'0" (5) HORIZ. LITES– 4 EQ.FIXED OVER 1 HOPPER X 12'-0" X 1'-8"/6'-8" 12'-0 1/2" X 1'-8 7/16"/6'-8 7/16" (3) 3'0"X1'8" FIXED MULLED UNITS/3'0"X10'0" (4) EQ. HORIZ. LITES– 3 FIXED OVER 1 HOPPER Y 3'-3" x 1'-6" 3'-3 1/2" x 1'-6 7/16" FIXED WINDOW SCHEDULE NOTES: 4'-0 1/2" X 1'-6 7/16" Z 4'-3" X 1'-6" FIXED WINDOWS BYXKAWNEER W/ OWNER1'-6 SPECIFIED PAINTED WINDOW INSTALLER TO FIELD VERIFY ALL ROUGH AA 1'-6" 7'-6" 1/2" X 7'-6 7/16" FINISH BY MANUFACTURER. FIXED OPENINGS AS REQUIRED. ALL UNITS TO BE 1" INSULATED GLASS W/ ONE SIDE TO BE LAMINATED SAFETY GLASS OR EQUIVALENT. PROVIDE TEMPERED GLASS UNITS WHERE REQUIRED BY CODE. SEE DETAILS SHEET A5.1 FOR TYPICAL HEAD, JAMB, AND SILL CONDITIONS.
SLOP 1/4" PEE TO DRAI R 1'-0" N
DES.SIZE – NOMINAL ROUGH OPENING
J. CORDER
CLERESTORY WINDOWS– SEE A2.1/A4.1
Date Issued
SECOND FLOOR PLAN SCALE: 1/4" = 1'-0"
1/A3.2
1/A3.1 8'-5 1/2" 12'-8 1/2"
28'-10 1/2"
3'-7"
4'-5" 39'-0 1/2"
67'-11"
4'-3 1/2"
5'-0 1/2"
A1.2 CAUTION: DO NOT SCALE DRAWINGS
ELECTRICAL FIXTURE LEGEND S D 3 4
SWITCH– TYPICAL
S
SWITCH– DIMMER
S
SWITCH– 3-WAY SWITCH– 4-WAY
S
OUTLET TYPICAL OUTLET–GROUND FAULT INT. GFI
OUTLET – SWITCHED OUTLET– WATERPROOF
WP
OUTLET– 220 VOLT OUTLET– FLOOR MOUNTED
220
OUTLET– CABLE TELEVISION
207 West 4th Austin,Texas 512·472· Fax ·472·
E
OUTLET– TELEPHONE
TV
RECESSED CAN
S
PENDANT OR SURFACE MOUNT WALL WASHER WALL MOUNTED/SCONCE
PROVIDE ELEC. STUB OUT FOR ADD'L. LIGHTING AS REQ.– SEE A1.1
STEP LIGHT STEREO SPEAKER
NOTE: CONTRACTOR TO PROVIDE LIGHTS IN RETENTION POND; PHOTCELL/SWITCH AS REQ. VER. W/ OWNER
E
S
Street 78701 4980 4991
Seal
VENT FAN
E WP
S
FLUORESCENT STRIP
E
M
E
CEILING FAN
E
S
2X FLUOURESCENT
E
Project
E WP
8'-0"
MATTHEWS RESIDENCE
J
TO 2nd SW. PANEL
501 WESTLAKE DRIVE AUSTIN, TEXAS 78746
E WP
*REFER TO FIXTURE SCHEDULE FOR ALL TYPE SPECIFIC INFO.
E 3 3 D
S S
TO LANDSCAPE LIGHTS
M J
R
WL
L
TO SWITCH @ STAIR HALL ABOVE
WP M
10'-0"
5'-0"
B
P
S DS D
D 4
D
M
SS
8'-0"
F
SS S
F
R
E
S
M
VERIFY W/ ARCH.
R
E
S
TV
10'-0"
Sheet TO PHOTO SWITCH
8'-0" D
S S
E
SLOPED CLG.
8'-0"
S
SLOPED CLG. PTD. GYP. BD.
STUCCO SOFFIT W/ DRIP EDGE
B
S
7'-6"
SS
D
3 4 D M
3
VERIFY S
D
E R R M
S
4 D
D
A/C M
SS
E
LT. @ ART NICHE
FIXTURE SCHEDULE SCHEDULE NOTES: * = LIGHTOLIER OR APPROVED EQUAL – CONTRACTOR TO PROVIDE LIGHTOLIER #1126 "FRESNEL" OR #1128 "WHITE DIFFUSER" OR APPROVED EQUAL AT SHOWER/BATHTUB OR WET AREAS. –CONTRACTOR TO PROVIDE INSULATED CEILING (IC) FRAME KITS WHERE REQUIRED BY CODE. –EXTERIOR SCONCES AND FIXTURES TO BE HOODED AND SHIELDED AS PER CITY OF WESTLAKE CODE REQUIREMENTS. – VERIFY HEIGHT OF ALL HUNG (PENDANT) FIXTURES, CEILING FANS, AND INTERIOR AND EXTERIOR SCONCES IN FIELD W/ ARCHITECT.
Revisions
SCALE: 1/4" = 1'-0"
GENERAL ELECTRICAL NOTES
10'-0" A/C
D D
S
HW
F
M
M
F GFI
S
M
M
REFLECTED CEILING PLAN – FIRST FLOOR
M
8'-0"
R
S S
SS
GFI
11
M
8'-0"
R
S
S
M
M
R
SS
D
3 D
M
B
R
8'-0"
F
R
STUCCO SOFFIT W/ DRIP EDGE TYPICAL– SEE 10/A5.1
B
S
M
B
DES.MANUFACTURER FIXTURE TYPE
DESCRIPTION
WATTSADDITIONAL INFO.
ALLOWANCE
B C
LIGHTOLIER* SELECTION BY OWNER
4 1/2" ADJUSTABLE ACCENT LIGHT PENDANT FIXTURE
PAR16 31066/7770 FRAME N/A
75 150
STANDARD APERTURE CONE VER. MOUNT HT IN FLD.
$300 EACH
D E F
SELECTION BY OWNER CUSTOM DESIGN FIXTURE SELECTION BY ARCH.
52" VAR. SPEED CLG. FAN EXTERIOR WALL MOUNTED SCONCE SURFACE MOUNTED
PENDING SELECTION N/A TO BE SELECTED
N/A 150 75-150
VER. MOUNT HT IN FLD.
G H J K L M N P Q R S
SELECTION BY OWNER LIGHTOLIER* LIGHTOLIER* LIGHTOLIER* CUSTOM DESIGN FIXTURE LIGHTOLIER* CUSTOM PENDANT CUTSHEET FOR APPROVAL SELECTION BY OWNER LIGHTOLIER* CUTSHEET FOR APPROVAL
52" VAR. SPEED CLG. FAN (EXTERIOR) 2X2 SURFACE MOUNT FLUORESCENT 2X4 SURFACE MOUNT FLUORESCENT UNDER COUNTER INCANDESCENT STRIP INTERIOR WALL MOUNTED SCONCE 2 1/4" PINHOLE APERTURE CUSTOM PENDANT RECESSED FAN PENDANT FIXTURE 4 1/2" RECESSED DOWNLIGHT STEP LIGHT
PENDING SELECTION "PRISMALYTE" H50-13/120SO "PRISMALYTE" H50-14/120SO "TASKMASTER 1" H150-09 N/A MR16 31069/7027QD FRAME SELECTION BY OWNER PENDING SELECTION PENDING SELECTION A-LAMP(A17) A7053/A400 FRAME PENDING SELECTION
N/A 120 120 8PH-13PH 75 12V/42-75 100 N/A 150 100 35
3/T8 LAMP #PRB2SRAVA3U4 4/T8 LAMP #PRB2SRAVA440 TSLOO18W120 LENGTHS VARY SEE PL. VER. MOUNT HT IN FLD. STANDARD APERTURE CONE ` VENT THRU ROOF TYPICAL VER. MOUNT HT IN FLD. #2010 BRUSHED CLEAR CONE PHOTOCELL W/ SWITCH OVERRIDE
T V
SELECTION BY OWNER CUTSHEET FOR APPROVAL
36" VA. SPEED CLG. FAN WATERPROOF POOL LT.
PENDING SELECTION PENDING SELECTION
N/A 40
PHOTOCELL W/ SWITCH OVERRIDE
W X Y Z
OWNER TO SELECT 8' TRACK LIGHTS IRIS OR EQ. LIGHTOLIER
SURFACE MOUNT OR PENDANT FIXTURE TRACK LIGHT STRIPS (8' OR EQ.) 4" MONOPOINT 4" REC. DN. LT. W/ LIGHTGEM 1404/05
PENDING SELECTION ARCH. TO SPEC. ARCH. TO SPEC. COBALT BLUE LIGHTGEM TRIM
150 N/A 60 VERIFY
$200 EACH $150 EACH $100 EACH $200 EACH
VER. MOUNT LOC. W/ ARCH. VER. MOUNT LOC. W/ ARCH.
$150 EACH $150 each $300 EACH N/A
–CONTRACTOR TO PROVIDE EXTRA ELECTRICAL CONDUIT FROM MAIN BREAKER BOX TO ATTIC FOR FUTURE POSSIBLE ELECTRONIC EQUIPMENT. –VERIFY AND COORD. LOCATIONS AND UTILITY REQUIREMENT OF ALL APPLIANCES AND EQUIPMENT PRIOR TO CONSTRUCTION. –WALL SCONCE HEIGHTS TO BE DETERMINED IN FIELD; CONSULT WITH ARCHITECT. ALL DIMENSIONS ARE TO CENTERLINE OF BOX. ALL EXTERIOR SCONCES TO MEET CITY OF WESTLAKE REQUIREMENTS; HOOD AND SHIELD AS REQUIRED. –ALL RECESSED LIGHTING FIXTURE TRIM RINGS TO BE PAINTED TO MATCH ADJACENT CONDITIONS (TYP.) –SWITCHES TO BE GANGED AS SHOWN. VERIFY SHOWN LOCATIONS WITH ARCHITECT IN FIELD PRIOR TO INSTALLATION. –THERMOSTAT(S) TO BE LOCATED BY HVAC ENGINEER. VERIFY LOCATIONS W/ARCHITECT. –GENERAL CONTRACTOR TO COORDINATE FIRE AND SECURITY ALARM SYSTEM WITH OWNER. CONSULT W/ ARCHITECT AS REQUIRED FOR SECURITY INSTALLATION AT ALL DOOR/WINDOW PENETRATIONS. –ELECTRICIAN TO INSTALL WHITE SMOKE DETECTORS TO CODE (HARDWIRED). VER. LOC. IN FLD. W/ ARCH. –ELECTRICIAN TO USE COPPER WIRE ONLY; NO ALUMINUM. –ALLOW ADEQUATE SWITCHED STUB-OUTS AT FRONT AND REAR FOR LANDSCAPE LIGHTING, ARCHITECTURAL LIGHTING. ALL TREE/LANDSCAPE LIGHTS TO BE LOCATED IN FIELD W/ ARCHITECT. PROVIDE SECOND SWITCH PANEL AT ENTRY FOR EXTERIOR LIGHTS –ALL SWITCHPLATES TO BE MOUNTED AT 54" A.F.F. U.N.O. ALL ELECTRICAL WALL OUTLETS TO BE MOUNTED AT 12" A.F.F. U.N.O. PLATES TO MATCH SWITCHPLATES, TYP. LOCATE ALL FLOOR OUTLETS WITH ARCHITECT IN FIELD. –CONTRACTOR TO PROVIDE GFI TYPE OUTLETS AT ALL WET AREAS & AS REQUIRED BY CODE. ALL OUTLETS AT BATHROOM,UTILITY, KITCHEN COUNTERS, ETC. TO BE MOUNTED AT 42" A.F.F. VERIFY W/ ARCHITECT AS REQUIRED. –ALL SPEAKER LOCATIONS TO BE COORDINATED BY AUDIO VISUAL CONSULTANT W/ ARCHITECT. –ALL FURR DOWNS TO BE PTD. GYP. BD. U.N.O. –ALL EXTERIOR SOFFITS TO BE PAINT GRIP METAL TO MATCH ROOF U.N.O. SEE A.1 FOR TYPICAL DETAIL. ALL STUCCO SOFFITS TO HAVE DRIP EDGES SIMILAR TO TYPICAL WINDOW HEAD DETAILS ON SHEET A5.2.
Drawn By J. CORDER
Date Issued
A1.3 CAUTION: DO NOT SCALE DRAWINGS
ELECTRICAL FIXTURE LEGEND S D 3 4
SWITCH– TYPICAL
S
SWITCH– DIMMER
S
SWITCH– 3-WAY
S
SWITCH– 4-WAY OUTLET TYPICAL OUTLET–GROUND FAULT INT.
GFI
WP
OUTLET – SWITCHED OUTLET– WATERPROOF OUTLET– 220 VOLT
220
OUTLET– FLOOR MOUNTED OUTLET– CABLE TELEVISION
TV
OUTLET– TELEPHONE RECESSED CAN PENDANT OR SURFACE MOUNT
207 West 4th Austin,Texas 512·472· Fax ·472·
WALL WASHER WALL MOUNTED/SCONCE STEP LIGHT STEREO SPEAKER
Street 78701 4980 4991
VENT FAN
Seal
FLUORESCENT STRIP
CEILING FAN NOTE: CONTRACTOR TO PROVIDE EXTERIOR SOFFIT LIGHTS OVER ENTRY STEPS. PROVIDE SWITCH AT 2ND SW. PANEL AT ENTRY
2X FLUOURESCENT
4'-0
"
G
R
S LO
"
S
IN CEIL P E D CH B SLOOF PIT RO
11'-4" VER.
F
D
R
SLOPED CEILING
M
7'-6"
7'-6"
Z
D
BARREL VAULTED CLG.
Z
S
+24"
D D
M
M
9'-0"
3 D D
M S S S D D S S D
F
SS
F
9'-0"
. CLG . PE . BD SLO . GYP PTD
HVAC
9'-0"
D
B
M
P
7'-6"
S S S
R
S SS
D 3 3 D DM
LN. OF BACK WALL OF FURR DOWN RECESS; SEE A3.2
Sheet
GYP. BD. R
S
D 3
S
Y
"
7'-6"
"
1/2
D DS
S B
Y
B
4'-0
R
9'-0"
PROVIDE STUB OUT FOR UNDER SHELF LT. STRIP; SEE 6/A4.1
Z
7'-0"
S
F
S M
M
501 WESTLAKE DRIVE AUSTIN, TEXAS 78746 5'-8
S
S
1'-6"
3 D
TV
D
D
8'-0"
MATTHEWS RESIDENCE
S
R
TO "M" THIS LOC. SEE A1.3
Y
Project
D
E
B
8'-0"
Y
.
WP S
3 D
4'-0
B
OW OLL
R
OF GT
6'-0"
CLG
R
TV
*REFER TO FIXTURE SCHEDULE FOR ALL TYPE SPECIFIC INFO.
PED
X 7'-6"
R
B
R
M
X
B
OUTLET ON END WALL BELOW L COUNTER
Revisions N
R
N
N
X Z
9'-0" R
X
3 D D
S S S TV
R
K
R
R
R K
K
R K
DISP.
R
R
R 3
SS
R K
R K
1'-6"
E
3
WP
3 3D D D
WP
S SS
Z
1'-6"
REFLECTED CEILING PLAN – SECOND FLOOR 11 SCALE: 1/4" = 1'-0"
Drawn By J. CORDER
VERIFY OUTLET HEIGHTS AT BOTH TV AND STEREO CABS. SEE A4.1 FOR MORE CABINET LAY OUT PROVIDE CONT. PLUG STRIP @ BASE OF COUNTER TOP AT BACKSPLASH; COORD. SPEC. AND LOC. W/ ARCH.
Date Issued
NOTE: IN WALL PLATE SPEAKERS TO BE MOUNTED AT REAR WALL OF COVE SOFFIT OVER KITCHEN; VER. LOC. IN FIELD W/ ARCH.
A1.4 CAUTION: DO NOT SCALE DRAWINGS