PEAUX-12

Product Specifications

PEAUX-12 Power Extender APPLICATION

FEATURES & BENEFITS • Works with incandescent, magnetic low voltage, halogen or neon/cold cathode lighting • Emulates the characteristics of the zone that it is connected to in terms of dimming range and resolution • Works with any D3208 Dimensions Multi-zone Controller/Dimmer to activate two auxiliary zones or add zones to the D3204 or D3206 Dimensions Multi-zone Controller

2.06 4.50

MOUNTING

2.80

4.72

All Power Extenders must have 4-1/2" spacing above and below each unit for proper ventilation and heat dissipation (refer to figure 3). Line voltage wiring should be at least 6ft away from sound or electronic equipment wiring. Mount Power Extender to wall box with “TOP” facing up as follows: For Wall Box Mounting (refer to figure 1), for Flush Mounting (refer to figure 2) and for Panel Mounting (not shown), proceed as follows: a. The enclosure must be in accordance with all local and national electrical codes.

Figure 3: Front View Spacing

b. Leviton DOES NOT recommend using a door to enclose the front of a panel, since this restricts airflow to the controls. c. If mounting multiple controls in an enclosure: • Ambient timperature within an enclosure “MUST o REMAIN BETWEEN”32 o o o 104 F (0 -40 C).

1900 Box Heat Shrink Tubing for Low-Voltage Wires 2 Gang Raised Cover Raised Cover Mounting Screws (4 Places)

TOP

4-1/2" (11.4 cm) Minimum

PEAUX

Power Extender Wallplate

Figure 1: Flush Mounting

• If not mounting in a metal enclosure, all units “MUST” be mounted in a wall box.

1900 Box Heat Shrink Tubing for Low-Voltage Wires 2 Gang Raised Cover Raised Cover Mounting Screws (4 Places)

d. To improve heat dissipation of controls, remove the faceplate from the unit.

4-1/2" (11.4 cm) Minimum

TOP

PEAUX Power Extender Wallplate

Figure 2: Surface Mounting

Leviton Mfg. Co., Inc. 59-25 Little Neck Pkwy • Little Neck, NY 11362-2591 • Tech Line: 1-800-824-3005 • Fax: 1-800-832-9538

Visit our Website at: www.leviton.com

PEAUX-12 Power Extender

Leviton’s PEAUX-12 Power Extender allows a D3200’s to control two auxiliary zones rated up to a total of 1920W/VA on 120V input power. The two auxiliary zones dim or switch a fully loaded circuit of incandescent and magnetic low voltage loads.

PEAUX-12 .........................

Product Specifications SPECIFICATIONS

Wiring Diagram 1: Single Feed Wiring Application w/Controller

Compatibility • All Dimension D3200 Multizone Controllers

Hot (Black) (120VAC)

Electrical

CAN L

Input Voltage: 120V, 50/60Hz

D3206/08 Controller/Dimmer

LOAD 2

Neutral Line

LOAD 1

HOT

N/C

N/C

Load Output Power: Phase independent of control device

NEUTRAL

CAN H

Load Rating: 1920W/VA Total 1000W/VA per zone max. Power Extender Auxiliary

Dimmer Input: 120V 50/60Hz

Green Ground

CAN H

CAN L

Testing/Code Compliance: UL Listed, CSA Certified and FCC Part 15

Low-Voltage Connector

Physical

LOAD

Color: Aluminum clear anodized extruded heat sink with a snap-on molded white cover

Neutral (White)

Back of device

Size: 4.72"L x 4.5"W x 0.5"H (120mm x 114mm x 12.7mm) Wiring Diagram 2: Dual Feed Wiring Application w/Controller

Environmental Operating Temperature Range: 0ºC to 40ºC Storage Temperature Range: -10ºC to 85ºC

Hot (Black) Line 1 (120VAC)

Relative Humidity: 20%-90% non-condensing Neutral 1 (White)

D3206/08 Controller/Dimmer

CAN L

Warranty: Limited 2-Year Warranty

LOAD 2

LOAD 1

N/C

HOT

INSTALLATION

NEUTRAL

Power Extender Auxiliary

N/C

CAN H

Neutral Line

Green Ground

CAN L

CAN H

High-Voltage Class 1 Wiring Low-Voltage Connector

• Connect wires in junction box using standard wiring practices.

Hot (Black) Line 2 (120VAC)

LOAD

• Pull power wiring from distribution panel and to light fixtures.

CAN H CAN L

• Each line voltage terminal can accept up to two #12 AWG wires.

Back of device

Neutral 2 (White)

LOAD 2

LOAD 1

N/C

Power Extender Auxiliary

HOT

• Daisy chain peripheral devices to LCnet bus.

NEUTRAL

NOT REQUIRED if installing only one D320X Zone Controller attached to no more than six zones.

N/C

Low-Voltage Class 2 Wiring

LOAD

• Make connections in junction box no longer than 29ft drop. • Run low voltage wires separately from line voltage. • Use CAT5-type twisted pair wiring.

Leviton Mfg. Co., Inc. 59-25 Little Neck Pkwy • Little Neck, NY 11362-2591 • Tech Line: 1-800-824-3005 • Fax: 1-800-832-9538

Visit our Website at: www.leviton.com © Copyright 2003 Leviton Manufacturing Co., Inc. All rights reseved. G-6835/A4-tp

LOAD