HGN-375
IEC 60320 INLET SOCKET WITH SWITCH, SINGLE AND DOUBLE FUSE HOLDER, FLANGE MOUNT MECHANICAL DIMENSIONS (Unit: mm) 52.0
67.0
Use only with a 250V Fuse Employer uniqement avec un fusible de 250V
O
33.5
40.0+- 0.2 0.8 TYP.
FEATURES
The HGN-375 protects electronic equipment from common and differential mode line interference in the range of 10KHz up to 30MHz. This “combi-unit” is equipped with IEC connector, fuse holder for one or two 5 x 20 mm fuses, 2 pole on/off switch and fully enclosed metal housing.
60.5
These filters are also available for Medical equipment with low leakage current. HGN-375 series filters are high performance filters and have been designed to bring various medical equipments into compliance with EN55011 and FCC Part 15J, Class B conducted emissions limits.
28.5 6.30 TYP.
APPLICATIONS
57.5
Computer & networking equipment, Measuring & control equipment, Data processing equipment, laboratory instruments, Switching power supplies, other electronic equipment.
TECHNICAL DATA
• Rated Voltage: 125/250VAC • Rated Current: 1A, 2A, 4A, 6A, 10A • Power Line Frequency: 50/60Hz • Max. Leakage Current each Line to Ground: @ 250VAC 50Hz: 0.5mA, max @ 250VAC 50Hz: 2µA*, max • Hipot Rating (one minute) Line to Ground: 2250VDC Line to Line: 1450VDC • Temperature Range: -25C to +85C
45.0
6.0
40.0+- 0.2 29.5 4x R0.5
61.5 2x M3
* Medical application
Specifications subject to change without notice. Dimensions (mm). See Appendix A for recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076 e-mail:
[email protected] • www.powerdynamics.com
79
HGN-375 Series Example & Ordering Code HGN-375 - 1 CURRENT RATING (A):
= = = = =
SCHEMATIC:
M - F2
1 2 4 6 10
STANDARD TYPE
=
WITHOUT C(Y); C(X) ONLY
=M
FUSE OPTION:
BLANK
1 FUSE (5X20MM), 6.3/0.25 QUICK CONNECT
= F1
2 FUSE (5X20MM), 6.3/0.25 QUICK CONNECT
= F2
Attenuation Tables & Schematics Non-Medical Applications Insertion loss in dB (50 Ohm circuit)
40 37 22 19 17
51 41 30 26 30
46 35 42 37 32 32 29 29 51 79
31 29 30 29 80
21 21 23 25 51
3 10 7 16 60 75 5 12 10 11 60 73 8 10 16 19 40 67 5 8 15 16 30 51 2 9 13 17 26 33
89 82 84 79 53
80 82 80 80 60
39 39 40 50 40
E P
FUSE
L(mH)
FUSE
L(mH)
2200pF E' 2200pF
LOAD
38 35 20 17 15
N' 0.01 F
33 30 17 13 6
0.033 F
24 16 10 8 5
L(mH)
FUSE 0.068 F
10.3mA 4.6mA 2.5mA 1.2mA 0.8mA
LINE
1A 2A 4A 6A 10A
N
1M
Current L Comm. Mode(L-G) MHz Diff. mode(L-L) MHz Rating Value .01 .05 .1 .15 .5 1 5 10 30 .01 .05 .1 .15 .5 1 5 10 30
P'
Medical Applications
80
32 30 18 13 13
38 35 20 17 16
41 36 22 19 19
51 41 30 26 25
48 36 42 37 32 32 29 29 28 29
31 30 30 29 29
22 21 22 24 24
2 10 8 15 60 75 5 12 10 10 60 73 8 10 17 19 40 67 5 7 15 17 30 51 5 5 15 18 30 51
84 82 84 80 79
80 83 80 80 80
39 36 33 41 51
E P
FUSE
L(mH)
E'
LOAD
23 18 10 8 8
N' 0.01 F
10.3mA 4.6mA 2.5mA 1.2mA 0.8mA
N
0.033 F
1A 2A 3A 4A 6A
Comm. Mode(L-G) MHz Diff. mode(L-L) MHz .01 .05 .1 .15 .5 1 5 10 30 .01 .05 .1 .15 .5 1 5 10 30
0.068 F
L Value
LINE
Current Rating
1M
Insertion loss in dB (50 Ohm circuit)
P'
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076 e-mail:
[email protected] • www.powerdynamics.com