TABLE OF CONTENTS Topic
Page
1. Rheem Introduction
4-5
2. Core Technology
6
3. Nomenclature
7
4. Model Numbers
7
5. Technical Specifications
8
3
Air
r
n
ner
INT EG RAT ED HO ME COM FO RT
Founded in the USA as a steel drum manufacturer by the Rheem brothers Rheem expanded internationally to Australia, Brazil, Canada and Singapore
4
Air
r
n
ner
INTE G RATE D HO ME COM FORT
complete air
25 Air
r
n
ner
INTE G RATE D HO ME COM FORT
5
CORE TECHNOLOGY Turbo* Press the "Turbo" button on the remote Turbo controller to enjoy better air w. This enables the indoor temperature to reach the set temp in a shorter period of time. Clock
Standard Features Dehumidifying y. Vertical Auto Swing* air and For a more temperature distribution throughout the room, air discharge can automatically move vertically.
Time is displayed on the remote controller. Self-diagnosis Once abnormal operation or part failure occurs, the unit will automatically shutoff to protect the system. Meanwhile, it will indicate protection or error code for diagnosis.
Horizontal Auto Swing For a more air and temperature distribution throughout the room, air discharge Louvre can automatically move horizontally.
S
Quiet Operation The Unit is designed to operate at the Lock* This feature avoids any accidental lowest noise by an ultra-low fan operation by children. speed and auto adjustment. LED Display Beautiful LED display for an attractive This smart feature utilizes the mini look. sensor in the remote controller, which can sense its surrounding temperature and transmit the signal to the indoor unit. Hence, the indoor unit Energy Saving* When this function is activated, the and temperature adjusts the air temperature setting is kept within a accordingly to provide maximum comlimited range for saving energy. fort. Sleep Mode Timer While the unit is in cooling, energyAutomatically turns the air condisaving or dry mode, the sleep mode tioner ON or OFF within a 24-hour activates: period. a. After an hour, the set temperature increases by 1°C (2°F). Auto Restart b. After 2 hours, the set temperature In the case of power shutdown, this increases by another 1°C (2°F). feature allows for the automatic restart Hence, the set temperature will totally with the previous settings, when the increase by 2°C (4°F) in 2 hours and power resumes. then the unit will continue to operate at *Not applicable to 36K BTU model this temperature. I Feel
03 INTERNAL REVISION CODE CAPACITY R410A WALL MOUNT DUCT FREE IDU FOR FIX COMPRESSOR RHEEM
ODU: R
F
G
L
012
C
T 220-240V / 50HZ / 1PH COOLING ONLY CAPACITY R410A FIX COMPRESSOR ODU FOR DUCT FREE RHEEM
MODEL NUMBERS Model 12000 18000 24000 28000 36000
System Model Nos. RDMA-CTT012T03 RDMA-CTT018T03 RDMA-CTT024T03 RDMA-CTT028T03 RDMA-CTT036T03
IDU Model Nos. RDMA-012-03 RDMA-018-03 RDMA-024-03 RDMA-028-03 RDMA-036-03
ODU Model Nos. RFGL-012CT03 RFGL-018CT03 RFGL-024CT03 RFGL-028CT03 RFGL-036CT03
7
Air
r
n
ner
INTE G RATE D HO ME COM FORT
RDMA-CTTxxxT03 Series
TECHNICAL SPECIFICATIONS
Parameter Rated Voltage Power Supply Rated Frequency Phases Cooling Capacity* Power Input* EER* Cooling Capacity** Power Input** EER** Net Weight Indoor Unit Gross Weight Net Weight Outdoor Unit Gross Weight Refrigerant
* (I) Entering Air D.B.T / Air W.B.T: 80 °F / 66 °F, (O) Entering Air D.B.T: 95 °F ** (I) Entering Air D.B.T / Air W.B.T: 84 °F / 66 °F, (O) Entering Air D.B.T: 115 °F Note: Microphone position 1.5m in front & 1.5m below the unit, measured in anechoic chamber
8
Air
r
n
ner
INT EG RAT ED HO ME COM FO RT
RDMA-CTTxxxT03 Series
Notes
Notes
Notes
Why Rheem?
For continuous product improvement, Rheem reserves the right to make changes to the product