F L U O R E S C E N T H I G H B AY S F L U O R E S C E N T L O W B AY S COMPLEX ENVIRONMENT REFLECTOR KITS
Industrial Fluorescent Energy Solutions
Our world is increasingly recognizing the importance of environmental sustainability and efficiency in building design. While cost containment and productivity gains are universal demands, increasing lighting efficiency requires an understanding of the role lighting plays in the business environment. Cooper Lighting has always been at the forefront in adopting and adapting to the latest advancements in lighting technology. Over the years, businesses and communities have benefitted from partnering with Cooper Lighting to improve energy efficiency and reduce costs while protecting and enriching the environment. To those of you considering a more efficient lighting upgrade, this brochure presents a variety of products and provides tips on how to make your retrofit project a success. A Cooper Lighting energy efficient lighting upgrade will reduce your utility bill; improve employee morale and productivity; and help protect and preserve the environment.
1
Table of Contents The Fluorescent Advantage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 3 Energy Savings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 3 Lamp Life and Lumen Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 3 Uniformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 3 Instant On/Off and Occupancy Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 4 T8 or T5HO? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 4 Thermal Performance and Light Output . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 5 Visible Light and the Scotopic/Photopic (S/P) Ratio . . . . . . . . . . . . . . . . . .pg. 6 Environmentally Friendly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 6 Product Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 7-8 HB/2HB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 9-14 I5/I8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 15-18 MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 19-20 3HBOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 21-22 2HBG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 23-24 HBHD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 25-26 ARCTIC BAY - AB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 27-28 VT2/VT3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 29-30 ECOFIT - STRIPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 31-32 ECOFIT - TROFFERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 33-34 OPTIONS AND ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 35-36 MOUNTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pgs. 37-38 OCCUPANCY SENSORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 39 POWER CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pg. 40 I5/I8 DOOR FRAMES AND WIREGUARDS . . . . . . . . . . . . . . . . . . . . . . . . .pg. 41 HB/2HB DOOR FRAMES AND WIREGUARDS . . . . . . . . . . . . . . . . . . . . . . .pg. 42
2
The Fluorescent Advantage The most popular and productive lighting upgrades today involve replacing outdated fluorescent or HID (High Intensity Discharge) lighting systems. High Performance fluorescent lighting systems from Cooper Lighting utilize the latest technologies and design platforms to provide dramatic energy savings and superior performance.
500
Energy Savings
455
400
Cooper Lighting fluorescent high bays offer dramatic energy savings opportunities over HID Lighting systems and provide quick returns.
300
346
200
221
229
F-Bay 2HB-632 $56.16 $74.88 $93.60 $112.32
F-Bay I5-454 T5HO $54.24 $72.32 $90.40 $108.48
100 0
400 Watt High Bay
KWH $0.06 $0.08 $0.10 $0.12
F-Bay 2HB-654 T5HO $26.16 $34.88 $43.60 $53.32
(based on 4000 hrs.)
ANNUAL ENERGY SAVINGS
Lamp Life and Lumen Maintenance Lamp Life & Lumen Maintenance 400 Watt High Bay T5 HO 6-Lamp T8 HO Ballast 6-Lamp
LIGHT OUTPUT
T5 and T8 fluorescent systems provide better maintained light levels over magnetic HID lighting systems with twice the lamp life. Multiple lamped fluorescent luminaires reduce the need for immediate maintenance. With fluorescent systems, the other lamps will stay illuminated when individual lamps extinguish.
T5 HO 4-Lamp End of Lamp Life
Initial
5000
10000
15000
20000
25000
35000
HOURS
Uniformity Linear fluorescent systems improve lighting uniformity compared with HID systems.
3
Dimensions 160 x 10 Fixture Type Number of Fixtures Initial Lumens per Lamp Initial Lumens per Fixture Light Loss Factor Input Wattage Maintained Average FC Max FC Min FC Average to Min Max to Min Vertical Average FC Max FC Min FC Average to Min
400W MH High Bay
4-Lamp 54W T5HO I5 Series
6-Lamp 32W HBF 2HB Series
13 36000 36000 0.66 455 43 47 37 1.2 1.3 22 35 12 2.9
13 4400 17600 0.855 229 33 38 27 1.2 1.4 15 23 9 1.7
13 2850 17100 0.963 221 43 48 36 1.2 1.3 20 30 11 2.7
400 Watt
High-Bay
Metalux 2HB-632 T8
Instant On/Off and Occupancy Sensors Fluorescent systems can be used with occupancy sensors to provide instant on/off capabilities to maximize energy savings. When using T8 lamps and occupancy sensors, Cooper Lighting industrial fluorescent luminaires use only softer starting “program start” ballasts to minimize damage to the lamp. Under frequent on/off cycles, program start ballasts will dramatically extend lamp life over “instant start” ballasts. Lamp Life Comparison
HRS/LAMP LIFE
40000 35000
Program Start Ballasts
30000
Instant Start Ballasts
25000 20000 15000 10000 5000 0
Metalux integral Occupancy Sensors are available in Aisle or 360° distributions.
15 min.
30 min.
3 hr.
1 hr.
12 hr.
Continuous
START FREQUENCY
T8 or T5HO? If your facility currently has T8 or T5HO lamps installed, the decision on lamp choice may be easy and allow for inventory consolidation. Both lamp types provide excellent performance but the attributes of each lamp type vary. Selection of lamp type is an important consideration. The following operating characteristics should be considered when making the selection:
Fluorescent High Bay System Comparison T8 Lighting Systems
T5HO Lighting Systems
First Costs
Similar within ranges to T5 systems with lower lamp costs offset by larger luminaire sizes.
Similar within ranges to T8 systems with higher lamp costs offset by smaller luminaire sizes.
Lamp Replacement Costs
Lower cost lamps offset with higher quantity for similar light output
Higher cost lamps offset with lower required quantity for similar light output
Lumens Per Watt
77
77
Application Heights
Suitable in wide ranges. Lower lumen output T8’s ideal for lower mounting heights below 15' and less ideal in mounting heights above 30'.
Suitable in wide ranges. Higher output T5HO lamps ideal for higher mounting heights where higher lumen values allow for a reduced number of lamps.
Ambient Environments
Dependent on luminaire. T8 systems achieve maximum output in 78°F (25°C) ambient environments. Starting temperature ranges as low as 0°F (-18°C) dependent on manufacturer of lamp, ballast, age of lamps and luminaire design
Dependent on luminaire. T5HO systems achieve maximum output in 95°F (35°C) ambient environments. Starting temperature ranges as low as -20°F (-29°C) dependent on manufacturer of lamps, ballast, age of lamps and luminaire design
Frequency of Starts
Standard T8 systems with instant start ballasts and frequent on/off cycles can dramatically reduce lamp life. Program Start T8 ballasts should be specified when used with high occurrence of on/off cycles.
Standard Program Start ballasted systems ideal for frequent starts and with use of occupancy sensors.
Ballasts Light Level Flexibility
Offered in multiple light output ranges typically from 71% to 115% of rated lamp life output allowing for flexibility in application without changing lamp type.
Currently offered in fixed Light output ranges.
Metalux 2HB632/PLUS using (6) 80+CRI T8 lamps with High Output ballasts.
Metalux I5455 using (4) T5HO 80+CRI lamps.
Luminaires in Comparison
Net Lumens: 17100
Net Lumens: 17600
Wattage: 221
Wattage: 229
4
Thermal Performance and Light Output Unlike HID lamps, T5 and T8 lamps reach optimal light output in specific temperature ranges. In partially or unconditioned spaces, temperatures from floor to ceiling can increase by over 20° in summer months. Annual Temperature Days Over 85°F (29°C)
Partially Conditioned Spaces 40 ft. 35 ft. @ 115°F (46°C)
30 ft. 20 ft.
20 ft. @ 95°F (35°C)
10 ft. 75°F (24°C)
Days over 85°F 0-10 11-40 41-70 71-99 100+
Bare Lamp Output in Ambient Temperatures 77°F (25°C)
95°F (35°C)
HID
100 90 80
T8
70
T5
60
Amalgam
50 40 30 20 °C °F
0 30
5 40
10 50
15 60
20 25 30 35 40 45 50 55 60 70 80 90 100 110 120 130 140
AMBIENT TEMPERATURES
Thermally advanced Cooper Lighting industrial products optimize light output of T5HO and T8 lamps for their designed temperature ranges. Choose lamp types that optimize light output for your ambient environment and consider the use of T5HO Amalgam lamps for higher performance over wider temperature ranges. ARCTIC BAY – AB Series
COLD
The Metalux Arctic Bay retains and manages heat allowing it to provide over 85% of light output in freezer applications down to -15°F (-26°C). 5
HOT
Metalux’s F-Bay series can be operated in environments up to 149°F (65°C) in open configurations.
Visible Light and the Scotopic/Photopic (S/P) Ratio Scotopic/photopic ratios have been developed that attempt to replicate a measurement system more akin to how our eyes perceive brightness. Even though our eyes use both rods and cones to see light, the rods are more sensitive to blue light (scotopic vision) and cones to yellow light (photopic vision). A traditional light meter measures only photopic lumens, which are the stated lumens referenced in lamp catalogs. A S/P Comparison of Fluorescent vs. HID 50000
LUMEN OUTPUT
The S/P Ratio acts as an adjustment to the existing photopic measurement by multiplying the standard lumens of a source with the S/P ratio or a factor thereof. As a result, an environment illuminated with warmer light sources, such as High Pressure Sodium, may appear darker than an environment illuminated with cooler light sources, like high CCT fluorescent lamps.
40% MORE LUMENS
20% LESS LUMENS
Initial System Lumens S/P Adjusted Initial Lumens
25000
0 2HB632 w/80 CRI 5000K Lamps
400W HPS High Bay
While an increasing number of lighting designers are endorsing the use of S/P ratios, this has not yet been endorsed by the Illuminating Engineering Society (IES). Cooper Lighting provides S/P adjusted lumen values throughout the product specification sections as reference information only and maintains no formal position on its application. Always test proposed products in application to validate results to your expectations
HPS vs. 5000K fluorescent – a visible difference!
Environmentally Friendly Cooper Lighting fluorescent luminaires are environmentally friendly. Housings and reflector assemblies are manufactured of recyclable steel and aluminum substrates and corrugated packaging is both recyclable and optimized in design to reduce waste on the job site. The use of low mercury fluorescent lamps also offers an attractive alternative to HID systems. A low mercury T5HO fluorescent lamp can contain as little 1.4 Mg. of mercury compared with up to 70 Mg. for a 400 watt Metal Halide lamp.
6
pgs. 15-18
pgs. 19-20
pgs. 21-22
HB/2HB
I5/I8
MB
3HBOT
Description
Industry-leading fluorescent high bay, HB & 2HB series features specification grade full body housing with two optical distributions - medium and wide - for structural integrity and optimal performance in conventional HID applications.
Narrow 11" specification grade body with two optics for medium and wide distributions and shielding options for industrial and aesthetic upgrades for retail and commercial applications.
High performance in narrow package with three optical distributions - Focus, Task, Normal - providing lower lighting power densities than HID and T12 sources at higher mounting heights. Continuous row installations provide unmatched uniformity performance.
Specification grade wide open body with optional side rails (3HBOT) is available with two optical distributions - medium and wide.
Lamping
HB: 2, 3, 4, lamp T5, T5HO, T8 2HB: 6 lamp T5, T5HO, T8
4': 2, 3, 4 lamp T5, T5HO, T8 8': 4, 6, 8 lamp T5, T5HO, T8
4': 1, 2 lamp T5HO, T8 8': 2, 4 lamp T5HO, T8
3HBOT: 8 lamp T5HO, T8
Replaces
150-400 Watt HPS 175-400 Watt MH HO, VHO T12 Fluorescent
150-400 Watt HPS 150-1000 Watt MH Slimline, HO, VHO T12 Fluorescent
150-400 Watt HPS 175-400 Watt MH HO, VHO T12 Fluorescent
400-1000 Watt, HPS 400-1000 Watt MH
Listings & Certification
UL/cUL Listed Damp Location
UL/cUL Listed Damp Location
UL/cUL Listed Damp Location
UL/cUL Listed Damp Location
Optional modular power receptacle meets UL2459 and NEC 410.73 (G) for make and break under load from outside to the luminaire to speed maintenance
Optional modular power receptacle meets UL2459 and NEC 410.73 (G) for make and break under load from outside to the luminaire to speed maintenance
Thermally optimized for environments up to 149°F (65°C) when used with high temperature ballasts in open uplight and downlight configurations
Thermally optimized for environments up to 149°F (65°C) when used with high temperature ballasts in open uplight and downlight configurations
T5 systems are warranted for ambient environments up to 104°F (40°C) in open uplight configurations
T5 systems are warranted for ambient environments up to 104°F (40°C) in open uplight configurations
T8 Systems are warranted for environments up to 122°F (50°C) in open uplight and downlight configurations
T8 Systems are warranted for environments up to 122°F (50°C) in open uplight and downlight configurations
AYC Chain, Top Connector Box, Gripple Y, HB Single Point Suspension, Stem Sets
AYC Chain, Top Connector Box, Gripple Loop, Gripple Toggle
Mounting
pgs. 9-14
7
Optional modular power receptacle meets UL2459 and NEC 410.73 (G) for make and break under load from outside to the luminaire to speed maintenance Thermally optimized for environments up to 122°F (50°C) when used with high temperature environment ballasts
AYC Chain, Gripple Y, Gripple Single Toggle
AYC Chain, Top Connector Box, Gripple Y, HB Single Point Suspension
HBG
HBHD
Arctic Bay
VT2/VT3
Ecofit Kits
Designed for use in high mounting height applications where periodic cleaning with high pressure is required. The 2HBHD is a surface mounted luminaire with a hole-free design and enclosed and gasketed to provide 800 psi hose down protection.
The Arctic Bay's enclosed full body housing and sealed and gasketed door frame provide optimal lamp operation - 90% rated light output down to -15°F (-26°C).
Energy efficient Vaportite fixture featuring T8 and T5HO lamp configurations with two optical distributions from a rugged and durable fiberglass housing and high impact diffuser.
Industrial & Troffer Ecofit conversion kits are an economical means of increasing fixture efficiency and energy savings when fixture removal is cost-prohibitive.
2HBHD: 4, 6 lamp T5, T5HO, T8
AB: 4 lamp T5HO 2AB: 6 lamp T5HO
4': 1, 2, 3 lamp T8 1, 2 lamp T5HO,
Industrial Strip 4': 1, 2 lamp T8, T5HO 8': 2, 4 lamp T8, T5HO
Description
pgs. 31-34
Energy-efficient alternative for recessed grid/lay-in concealed T, and slot grid ceilings and flange trim applications. HBG is available with optional shielding options for a seamless ceiling line.
Lamping
pgs. 29-30
2HBG: 4, 6 lamp T5, T5HO, T8
Replaces
pgs. 27-28
150-400 Watt HPS 175-400 Watt MH HO, VHO T12 Fluorescent
250-400 Watt HPS 250-400 Watt MH HO, VHO T12 Fluorescent
150-400 Watt HPS 175-400 Watt MH HO, VHO T12 Fluorescent
50-400 Watt HPS 50-400 Watt MH Slimline, HO, VHO T12 Fluorescent
Industrial Strip Slimline, HO, VHO T12 Fluorescent with channels 4"-5-1/4" wide Troffer 3, 4 lamp T12, T8 Fluorescent, nominal 24" x 24", 24" x 48"
Listings & Certification
pgs. 25-26
UL/cUL Listed Damp Location
UL/cUL Listed Wet Location
UL/cUL Listed Damp Location
Manufactured in compliance with USDA, FDA, NSF and Federal Standard 209E in surface mount applications
Thermally optimized for environments down to -20°F (-29°C)
UL/cUL Listed Wet Location
UL/cUL Listed Fixture Accessory
Mounting
pgs. 23-24
Recessed Grid or Flange
8': 2, 4, 6 lamp T8 2, 4, lamp T5HO
Troffer 24" x 24", 24" x 48": 2, 3 lamp T5HO, T8
IP65 Compliant
IP65 Compliant
Surface mount or Pendant mount
AYC Chain, Top Connector Box, Gripple Y, HB Single Point Suspension, Stem Sets
Mounting Bracket Included or VT2 Chain/Set-U
N/A
8
HB/2HB
H I G H - B AY I N D U S T R I A L L U M I N A I R E
Full bodied housing utilizes captive fasteners to protect optical assembly and assure structural integrity. Optional top access plate allows service in electrical compartment without removal of lamps. (T8 option only) Optional uplight apertures (approximately 8% uplight)
Housing is “Post” painted with a high performance polyester powder coat finish to protect against contaminants and oxidation.
Optional modular power receptacle meets UL2459 and NEC 410.73 and is UL/cUL rated for make and break under load from outside the luminaire to speed maintenance.
Thermally optimized F-Bay is suitable for environments up to 149°F (65°C) when used with high temperature environment ballasts. T5 systems are warranted for ambient environments up to 149°F (65°C) for three years and 131°F (55°C) for five years in open uplight and downlight configurations. T8 systems are warranted for environments up to 122°F (50°C) for five years. Die formed reflectors are faceted for 2, 3, 4 and 6 lamp configurations with two optical distributions medium and wide. Medium beam optical modules utilize 95% specular Miro 4 substrate while the wide distribution utilizes a high performance 95% reflective polyester powder coated finish. Integral occupancy sensor available and provides from 600 sq. ft. (MS) up to 1250 sq. ft. (MSO) of coverage in a maximum mounting height of 40'.
Modular F-Bay Power Supply
Cooper Lighting’s F-Bay Modular Power Supply option allows external fixture access for safe and easy servicing. There is no need to remove lamps or reflectors to disconnect fixture power with F-Bay Modular Power Supply. Access to the individual fixture’s power supply allows servicing without turning off all the fixtures disrupting occupants. F-Bay Modular Power Supply is a time saver in installation – simply plug & power. Code Compliance • UL/cUL Certified for Make/Break under load (UL2549) • Meets NEC requirements for ballast disconnect (NEC 410.73G) 1
1. Modular Power Supply Receptacle supplied mounted into fixture Access Plate 2. Modular Power Cord & Plugs in 120, 277, 347, & 480V configurations for easy plug & power into existing supply
9
• Allows for addition of Occupancy Sensor without hard connections
2 No internal fixture access required for installation or disconnecting power
Modular Motion Sensor Option supplied with Mounting Box and Modular Power Supply Receptacle
• Receptacles complete with insulating/dust cap
Shielding Options
Prismatic or clear acrylic lens & steel door frame Optional gasketed door available
Wireguard w/acrylic lens and steel door frame
Heavy duty stock wireguard (Ideal for gymnasium applications)
Mounting Accessories
TCB=Top Connector Box
FH-1=Fixture Hook 2-1/2" FL-1=Fixture Loop 2-1/2" RH-1=Retrofit Hanger SC-_-_=Stem Sets (fixed, (must be used with TCB) (must be used with TCB) (must be used with TCB) Swivel or Adjustable SCF=Fixed SCA=Adjustable SCS=Swivel
HB-SPS=Single Point Cable Kit
AYC-Mounting chain set (not for use in gymnasiums or similar recreational facilities)
Y=Mounting Toggle and 10' or 25' cable
HB-SPS=Two Point Suspension 65.6°C/150°F 57.2°C/135°F 48.9°C/120°F 40.6°C/105°F 32.2°C/90°F
Thermal Optimization
23.9°C/75°F
To optimize luminaire performance, HB/2HB series offers a variety of lamp and shielding options. Use the Thermal Optimization chart to determine the options that are appropriate for the ambient environments in which they will be installed.
15.6°C/60°F 7.2°C/45°F -1°C/30°F -9.4°C/15°F -17.8°C/0°F -15°F
Unvented Vented w/Uplight wo/Uplight
Lensed Unvented Vented Lensed Luminaire w/Uplight wo/Uplight Luminaire
T8
T5HO
Vented w/Uplight T5HO Amalgam
Operating at approximately 90% or above of rated output
System Performance
HB
2HB
Mounting Height
40'
30' 250W MH
400W MH
250W HPS
400W HPS
400W MH
400W HPS
400W MH
400W HPS
20' 250W MH
250W HPS
250W MH
250W HPS
10' Energy Savings % Light Gain/Loss Part Number
66%
66%
8% -20%
HB-332-EB8/PLUS
50%
51%
38%
39%
50%
31%
10%
35%
16%
17% -4%
HB432UPL or HB432PSUPL
HB-354T5-EBT1
T8
HB454T5UPL or HB454T5UPL T5
51%
51%
20%
2HB632UPL or 2HB632PSUPL T8
52%
0%
24%
25%
44%
30%
2HB654T5UPL or 2HB654T5UPL T5
% light gain/light loss utilize S/P adjusted lumens.
10
2HB
Ordering Information
H I G H - B AY I N D U S T R I A L L U M I N A I R E
Sample Number: 2HB-632-A-UNV-EB82/PLUS-UPL-U
Voltage (2) UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage 120V=120 Volt 277V=277 Volt 347V=347 Volt 480V=480 Volt
Width 2=24" Series HB=High Bay Mounting Arrangement Blank=Stand Alone R=Continuous Row Mount No of Lamps 6=6 Lamps Lamp Type 32=32W T8 Lamps (48") 28T5=28W T5 Lamps (48") 54T5=54W T5HO Lamps (48") Distribution Blank=Medium (Specular Aluminum) G=Wide (High Reflectance White) (12)
Shielding Blank=None A=Prismatic Acrylic Lens & Door Frame WG=Wireguard & Door Frame A/WG=Acrylic Lens, Wireguard & Door Frame CL=Clear Acrylic Lens & Door Frame CL/WG=Clear Lens, Wireguard & Door Frame CL/DWG=Clear Lens, Drop Wireguard & Door Frame DWG=Drop Wireguard & Door Frame A/DWG=Acrylic Lens, Drop Wireguard & Door Frame
Options Lamps Installed L8830=T8 Lamp, 85CRI 3000K L8835=T8 Lamp, 85CRI 3500K L8841=T8 Lamp, 85CRI 4100K L8850=T8 Lamp, 85CRI 5000K L5830=T5 Lamp, 85CRI 3000K L5835=T5 Lamp, 85CRI 3500K L5841=T5 Lamp, 85CRI 4100K L5850=T5 Lamp, 85CRI 5000K GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (2) (see table on pg 36)
Ballast Type T8 Systems EB8 =T8 Electronic Instant Start (4) Total Harmonic Distortion < 10% No of Ballast 2 or 3 EB8 /PLUS= T8 Electronic Instant Start (4) High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 2 or 3 ER8 =T8 Electronic Program Rapid Start (4) Total Harmonic Distortion < 10% No of Ballast 2 or 3 ER8 /PLUS= T8 Electronic Program Start (4) High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 2 or 3
Packaging Options U=Unit Pack NUA=No Uplight Apertures PAL=Palletized In Housing (Cannot be Out of Carton combined w/UPL) PALC=Palletized UPL=Uplight Apertures In Carton PI/CPI=Plug-In (1, 2 or 3) (9) see pg 40 TILW=Tandem Inline Wiring MWS=Modular Wiring System MS=Aisle Coverage Motion Sensor (5) MSO=360° Coverage Motion Sensor (5) C3=3' Power Cord C6=6' Power Cord G2=Gasketed Door (Requires Selection of Lensed Door Frame) MP=Modular Power Receptacle (1) (2) PC3-=3' Power Cord & Plug (Specify Voltage) PC6-=6' Power Cord & Plug (Specify Voltage) TAP=Top Access Plate (11) TCBP=Top Connector Box Plate (6)
T5 Systems EBT =T5 Linear Electronic Program Rapid Start (3) Total Harmonic Distortion < 10% No of Ballast 2 or 3 EHT =T5 Linear Electronic Start High Ambient (7) (8) (12) Total Harmonic Distortion < 10% No of Ballast 2 or 3 DIM=Dimming
Accessories (order separately) AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-Hooks (10) TCB=Top Connector Box RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop HB-SPS=Single Point Cable Kit (13" Drop Length) GRIPPLE-Y- =Y Mounting Toggle, #2 Cable (Specify 10' or 30') MC3=3' Modular Power Cord MPC3=3' Modular Power Cord & Plug (Specify Voltage) MC6=6' Modular Power Cord MPC6=6' Modular Power Cord & Plug (Specify Voltage) MMS-CPD1200H=Aisle Motion Sensor, Box, Modular Power Receptacle (120/277V) MMS-CPD500H=360° Motion Sensor, Box, Modular Power Receptacle (120/277V) SWG/2HB-4FT-B=Heavy Duty Wireguard (2HB)
NOTES: (1)Requires use of MC or MPC cord accessories, specify voltage for plugs (2)Voltage must be specified when ordered with plugs, motion or emergency ballasts (3) EBT ballast systems suitable for operation in ambient environments up to 104°F (40°C) in open uplight configuration (4)ER8 and EB8 ballast systems suitable for operation in ambient environments up to 122°F (50°C) in open uplight configuration (5)Specify voltage (6)For use with Top Connector Box options See accessories (7)2 lamp ballast configurations only in UNC versions (8) EHT/HT5/HCT5 ballast systems suitable for ambient environments not to exceed 149°F (65°C) in open uplight configurations and less lens option (9)Cannot be combined with cord or cord & plug option See PI ordering information below (10)Not for use in high abuse applications such as gymnasiums (11)For use with T8 system with a maximum of two ballasts (including EM ballast) (12)Lensed 6-lamp T5HO luminaires must use High Ambient ballast option (EHT)
Quick Ship Ordering Information
Sample Number: 2HB632PS-MP-UPL-L5 Includes V Hangers for Quick Ship orders ship in 5 days in order quantities not to exceed 200 pieces rapid installation NOTE: Orders received after noon are entered on the following day
Ballast Type T5HO Systems T5=(2) 120/277V 4/2 Lamp T5 Electronic Program Rapid Start (13) HT5=(2) 120/277V 4/2 Lamp T5 High Ambient Electronic Program Rapid Start (8) HCT5=(2) 347/480V 2 Lamp T5 High Ambient Electronic Program Rapid Start (8) T8 Systems(4) Blank=(2) 120/277V 4/2 Lamp T8 Instant Start Electronic High Ballast Factor >1 15 PS=(2) 120/277V 4/2 Lamp T8 Electronic Program Rapid Start High Ballast Factor >1 15 (13)
Family 2HB No of Lamps 6=6 Lamps Lamp Type 32=32W T8 Lamps (48") 54=54W T5HO Lamps (48") NOTES: (13) Recommended when utilizing Motion Sensor option (14) Requires use of Modular cord and plug accessories (15) High lumen (3100 initial) 4100K T8 lamps supplied
Power Receptacle Blank=Standard Wiring to Access Plate MP=Modular Power Receptacle (14)
Dimensions
Optional Lamping Blank=No Lamps L4=Lamps Installed 80+CRI 4100K (15) L5=Lamps Installed 80+CRI 5000K
Quick Ship Accessories (order separately) MC3=3' Modular Power Cord MC6=6' Modular Power Cord MPC6=6' Modular Power Cord & Plug (Specify Voltage) MPC3=3' Modular Power Cord & Plug (Specify Voltage) MMS-CPD1200H=Aisle Motion Sensor, Box, Modular Power Receptacle (120/277V) MMS-CPD500H=360° Motion Sensor, Box, Modular Power Receptacle (120/277V)
Access Plate Opening
Mounting for Top Connector Box
6-Lamp T5/T8
11/16" [18mm] K O 17/64" Diameter Hole
Dimensions for Top View
2HB Lamp Configurations
24" [610mm]
4-3/4" [121mm] X=3-1/2" [89mm]
Optional Uplight Blank=No Uplight UPL=Uplight
Door Frames (for Field Installation)(12) 2HB-4-A-W/FRM PK=Prismatic Acrylic Lens & Frame (2HB) 2HB-FRM/CL PK=Clear Acrylic Lens & Frame (2HB) 2HB-FRM/WG PK=Wireguard & Frame (2HB) 2HB-FRM/CL/WG PK=Clear Acrylic Lens, Frame and Wireguard (2HB) 2HB-FRM/LENS/DROPWG PK=Drop Wireguard, Prismatic Lens and Frame (2HB) 2HB-FRM/CL/DROPWG PK=Drop Wireguard, Clear Acrylic Lens and Door Frame (2HB) 2HB-FRM/LENS/DROPWG PK=Drop Wireguard, Prismatic Acrylic Lens and Door Frame (2HB) 2HB-FRM/DROPWG PK=Drop Wireguard and Door Frame (2HB)
X
X
X
X
X
24" [610mm]
2-1/4" [58mm] 3-1/2" [89mm] 48" [1219mm]
11
Photometrics Coefficients of Utilization Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
108 98 88 80 73 67 62 57 53 50 46
108 93 80 70 62 55 49 45 41 37 34
108 108 89 85 74 68 62 56 53 47 46 40 41 35 36 31 33 27 29 24 27 22
2HB-654T5-G-UNV-EBT2-UPL Electronic Ballasts (6) 54W T5 lamps 26400 lumens Spacing criterion: (II) 1 3 x mounting height, (⊥) 1 4 x mounting height Efficiency 92% Test Report: 09312
99 85 74 64 57 51 46 41 38 35 32
99 82 69 58 50 44 39 35 31 28 26
Coefficients of Utilization 20% 30% 50 30 10
99 79 64 53 45 39 34 30 26 24 21
93 81 70 61 54 48 44 40 36 33 31
93 78 66 56 48 42 37 33 30 27 25
93 76 62 52 44 38 33 29 26 23 21
Lumens 5567 9168 16767 22592 24276
%Lamp 21 1 34 7 63 5 85 6 92 0
%Fixture 22 9 37 8 69 1 93 1 100 0
Coefficients of Utilization Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
108 98 89 80 73 67 62 57 53 50 47
108 93 81 70 62 55 50 45 41 37 34
108 108 89 86 74 69 63 57 54 48 47 41 41 35 37 31 33 27 30 25 27 22
2HB-632-G-UNV-EB82-UPL (2) Electronic Ballasts (6) 32W T8 lamps 17100 lumens Spacing criterion: (II) 1 3 x mounting height, (⊥) 1 4 x mounting height Efficiency 92 1% Test Report: 09308
98 85 74 65 57 55 46 42 38 35 32
98 82 69 59 51 44 39 35 31 28 26
Lumens 3635 6006 10946 14505 15743
113 99 86 76 68 61 56 51 46 43 40
113 113 95 91 80 75 69 63 60 54 53 47 47 41 43 37 39 33 35 30 32 28
103 91 80 71 63 57 52 48 44 41 38
20% 30% 50 30 10
103 103 88 85 75 71 65 60 57 52 51 45 45 40 41 36 37 33 34 30 31 27
98 86 76 67 61 55 50 46 42 39 37
98 84 72 63 55 49 44 40 36 33 31
98 82 68 58 51 44 39 35 32 29 27
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Lumens 7884 11985 18923 23788 25251
%Lamp 29 9 45 4 71 7 90 1 95 7
%Fixture 31 2 47 5 74 9 94 2 100 0
Coefficients of Utilization 20% 30% 50 30 10
98 79 65 54 45 39 34 30 27 24 22
93 80 70 61 54 48 44 40 36 33 31
93 78 66 56 49 43 38 34 30 28 25
%Lamp 21 3 35 1 64 0 84 8 92 1
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
93 76 62 52 44 38 33 29 26 23 21
113 103 94 86 79 73 68 63 59 55 52
113 99 87 77 68 61 56 51 46 43 40
113 113 95 91 80 75 69 63 60 54 53 47 47 41 43 37 39 33 35 30 32 28
2HB-632-UNV-EB82-UPL Electronic Ballasts (6) 32W T8 lamps 17100 lumens Spacing criterion: (II) 1 3 x mounting height, (⊥) 1 0 x mounting height Efficiency 96% Test Report: 09306
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
113 103 94 86 79 73 68 63 59 55 52
2HB-654T5-UNV-EBT2-UPL (2) Electronic Ballasts (6) F54T5/HO 830 54W lamps 4400 lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 1 0 x mounting height Efficiency 95 7% Test Report: 09309
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
%Fixture 23 1 38 1 69 5 92 1 100 0
103 91 80 71 63 57 52 48 44 41 38
20%
103 103 88 85 75 71 65 60 57 52 51 45 45 40 41 36 37 32 34 29 31 27
30% 50 30 10 98 86 76 68 61 55 50 46 42 39 36
98 84 72 63 55 49 44 40 36 33 31
98 82 69 58 51 44 39 35 32 29 27
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Lumens 4989 7631 12278 15392 16402
%Lamp 29 2 44 6 71 8 90 0 95 9
%Fixture 30 4 46 5 74 9 93 8 100 0
Illuminance Estimator Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD) Based on 100 ft. x 100 ft. Open Areas Multiplier Spacing on Center 15 ft 20 ft 25 ft 30 ft
15 ft FC LPD 59 0.6 41 0.42 26 0.27 15 0.15
4L 32W T8 0.67 20 ft FC LPD 55 0.6 38 0.42 24 0.27 14 0.15
25 ft FC LPD 51 0.6 35 0.42 23 0.27 9 0.15
30 ft FC LPD 47 0.6 33 0.42 21 0.27 12 0.15
2HB 6L 54W T5HO w/Uplight
35 ft FC LPD 44 0.6 31 0.42 20 0.27 11 0.15
Mounting Height
Mounting Height
2HB 6L 32W T8 Plus
Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD) Based on 100 ft. x 100 ft. Open Areas Multiplier Spacing on Center 15 ft 20 ft 25 ft 30 ft
15 ft FC LPD 80 1.23 55 0.86 35 0.55 20 0.31
4L 54W T5HO 0.67
20 ft FC LPD 74 1.23 51 0.86 33 0.55 19 0.31
25 ft FC LPD 69 1.23 48 0.86 31 0.55 17 0.31
30 ft FC LPD 64 1.23 45 0.86 29 0.55 16 0.31
35 ft FC LPD 60 1.23 42 0.86 27 0.55 15 0.31
Choose the spacing and mounting height to determine the average footcandle and watts per square foot values. Use the multipliers to factor other available lamp/ballast configurations.
System Performance Table
Wattage
Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh
2HB632-EB81/PLUS
6
3100
94%
89%
1.15
17895
1.95
1.40
24989
221
$2.77
116
2HB654T5 or 2HB654T5-EHT
6
5000
93%
93%
1.00
25919
1.90
1.38
35727
346
$3.34
96
400W Metal Halide High Bay
1
36000
58%
78%
1
16307
1.50
1.22
19972
455
$9.33
34
400W High Pressure Sodium High Bay
1
50000
81%
78%
1
31631
0.62
0.79
24906
464
$7.63
42
2HB System Comparison
No of Lamps
Design S/P Lamp Lumen Fixture Ballast System S/P Brightness Adjusted Lumens Maintenance1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4
LER5
Comparison System
FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 5000K lamps 5 LER (Luminaire Efficiency Ratio) is an accepted method of comparing fixture performance
12
HB
Ordering Information
H I G H - B AY I N D U S T R I A L L U M I N A I R E
Sample Number: HB-432-A-UNV-EB81
Voltage (2) UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage 120V=120 Volt 277V=277 Volt 347V=347 Volt 480V=480 Volt
Width Blank=15" Series HB=High Bay Mounting Arrangement Blank=Stand Alone R=Continuous Row Mount
Options Lamps Installed L8830=T8 Lamp, 85CRI 3000K L8835=T8 Lamp, 85CRI 3500K L8841=T8 Lamp, 85CRI 4100K L8850=T8 Lamp, 85CRI 5000K L5830=T5 Lamp, 85CRI 3000K L5835=T5 Lamp, 85CRI 3500K L5841=T5 Lamp, 85CRI 4100K L5850=T5 Lamp, 85CRI 5000K GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (see table on pg 36)
No of Lamps 2=2 Lamps 3=3 Lamps 4=4 Lamps(12) Lamp Type 32=32W T8 Lamps (48") 28T5=28W T5 Lamps (48") 54T5=54W T5HO Lamps (48") Distribution Blank=Medium (Specular Aluminum) G=Wide (High Reflectance White) Shielding (12) Blank=None A=Prismatic Acrylic Lens & Door Frame WG=Wireguard & Door Frame A/WG=Acrylic Lens, Wireguard & Door Frame CL=Clear Acrylic Lens & Door Frame CL/WG=Clear Lens, Wireguard & Door Frame CL/DWG=Clear Lens, Drop Wireguard & Door Frame DWG=Drop Wireguard & Door Frame A/DWG=Acrylic Lens, Drop Wireguard & Door Frame
Ballast Type T8 Systems EB8 =T8 Electronic Instant Start (4) Total Harmonic Distortion < 10% No of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Instant Start (4) High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 1, 2 or 3 ER8 =T8 Electronic Program Rapid Start (4) Total Harmonic Distortion < 10% No of Ballast 1, 2 or 3 ER8 /PLUS= T8 Electronic Program Start (4) High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 1, 2 or 3
Packaging Options U=Unit Pack NUA=No Uplight Apertures PAL=Palletized In Housing (Cannot be Out of Carton combined w/UPL) PALC=Job Pack UPL=Uplight Apertures In Carton PI/CPI=Plug-In (1, 2 or 3) (9) see pg 40 TILW=Tandem Inline Wiring MWS=Modular Wiring System MS=Aisle Coverage Motion Sensor (5) MSO=360° Coverage Motion Sensor (5) C3=3' Power Cord C6=6' Power Cord G2=Gasketed Door (Requires Selection of Lensed Door Frame) MP=Modular Power Receptacle (1) (2) PC3-=3' Power Cord & Plug (Specify Voltage) PC6-=6' Power Cord & Plug (Specify Voltage) TAP=Top Access Plate (11) TCBP=Top Connector Box Plate (6)
T5 Systems EBT =T5 Linear Electronic Program Rapid Start (3) Total Harmonic Distortion < 10% No of Ballast 1, 2 or 3 EHT =T5 Linear Electronic Start High Ambient (7) (8) (12) Total Harmonic Distortion < 10% No of Ballast 1, 2 or 3 DIM=Dimming
Accessories (order separately) AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-Hooks (10) TCB=Top Connector Box RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop HB-SPS=Single Point Cable Kit (13" Drop Length) GRIPPLE-Y- =Y Mounting Toggle, #2 Cable (Specify 10' or 30') MC3=3' Modular Power Cord MPC3=3' Modular Power Cord & Plug (Specify Voltage) MC6=6' Modular Power Cord MPC6=6' Modular Power Cord & Plug (Specify Voltage) MMS-CPD1200H=Aisle Motion Sensor, Box, Modular Power Receptacle (120/277V) MMS-CPD500H=360° Motion Sensor, Box, Modular Power Receptacle (120/277V) SWG/HB-4FT-B=Heavy Duty Wireguard (HB)
NOTES: (1)Requires use of MC or MPC cord accessories, specify voltage for plugs (2)Voltage must be specified when ordered with plugs, motion or emergency ballasts (3) EBT ballast systems suitable for operation in ambient environments up to 104°F (40°C) in open uplight configuration (4)ER8 and EB8 ballast systems suitable for operation in ambient environments up to 122°F (50°C) in open uplight configuration (5) Specify voltage (6) For use with Top Connector Box options See accessories (7) 2 lamp ballast configurations only in UNC versions (8) EHT/HT5/HCT5 ballast systems suitable for ambient environments not to exceed 149°F (65°C) in open uplight configurations and less lens option (9) Cannot be combined with cord or cord & plug See PI ordering information below (10) Not for use in high abuse applications such as gymnasiums (11) For use with T8 system with a maximum of two ballasts (including Emergency ballast) (12)Lensed 4-lamp T5HO luminaires must use High Ambient ballast option (EHT)
Quick Ship Ordering Information
Sample Number: HB454T5-MP-UPL-L5
Quick Ship orders ship in 5 days in order quantities not to exceed 200 pieces NOTE: Orders received after noon are entered on the following day
Family HB Lamp Qty 4=4 Lamps Lamp Type 32=32W T8 Lamps (48") 54=54W T5HO Lamps (48") NOTES: (13) Recommended when utilizing Motion Sensor option (14) Requires use of Modular cord and plug accessories (15) High lumen (3100 initial) lamps supplied 4100K T8 only
Ballast Type T5HO Systems T5=(1) 120/277V 4 Lamp T5 Electronic Program Rapid Start (13) HT5=(1) 120/277V 4 Lamp T5 High Ambient Electronic Program Rapid Start (8) HCT5=(1) 347/480V 2 Lamp T5 High Ambient Electronic Program Rapid Start (8) T8 Systems (4) Blank=(1) 120/277V 4 Lamp T8 Instant Start Electronic High Ballast Factor >1 15 PS=(1) 120/277V 4 Lamp T8 Electronic Program Rapid Start High Ballast Factor >1 15 (13)
Includes V Hangers for rapid installation
Power Receptacle Blank=Standard Wiring to Access Plate MP=Modular Power Receptacle (14)
Door Frames (for Field Installation)(12) HB-FRM/LENS=Prismatic Acrylic Lens & Frame (HB) HB-FRM/CL PK=Clear Acrylic Lens & Frame (HB) HB-FRM/WG PK=Wireguard & Frame (HB) HB-FRM/LENS/WG PK=Prismatic Acrylic Lens, Frame and Wireguard (HB) HB-FRM/DROPWG PK=Frame and Drop Wireguard for HB
Quick Ship Accessories (order separately) MC3=3' Modular Power Cord MC6=6' Modular Power Cord MPC6=6' Modular Power Cord & Plug (Specify Voltage) MPC3=3' Modular Power Cord & Plug (Specify Voltage) MMS-CPD1200H=Aisle Motion Sensor, Box, Modular Power Receptacle (120/277V) MMS-CPD500H=360° Motion Sensor, Box, Modular Power Receptacle (120/277V)
Optional Uplight Blank=No Uplight UPL=Uplight Optional Lamping Blank=No Lamps L4=Lamps Installed 80+CRI 4100K(15) L5=Lamps Installed 80+CRI 5000K
Dimensions 2HB Lamp Configurations
Dimensions for Top View 3-Lamp T5/T8
2-Lamp T5/T8
Access Plate Opening
Mounting for Top Connector Box
X=6-5/16" [161mm]
X 15-7/16" [392mm]
X=3-9/16" [91mm]
11/16" [18mm] K O 17/64" Diameter Hole
4-3/4" [121mm]
4-3/4" [121mm]
X
X
15-7/16" [392mm]
15-7/16" [392mm]
4-Lamp T5/T8 4-3/4" [121mm]
2-1/4" [58mm] X=2-7/8" [74mm]
13
X
X
X
15-7/16" [392mm]
3-1/2" [89mm] 48" [1219mm]
Photometrics Coefficients of Utilization Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
112 103 95 88 81 75 70 65 61 57 54
112 99 88 79 71 64 58 53 49 46 42
112 112 96 93 83 78 72 67 63 58 56 51 51 45 46 41 42 37 38 33 35 31
HB-254T5-UNV-EBT1-UPL Electronic Ballasts (2) FP54/835/HO lamps 4400 lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 0 9 x mounting height Efficiency 95 5% Test Report: HB254T5UPL IES
101 91 81 73 66 60 54 50 46 43 40
101 88 77 67 60 53 48 44 40 37 34
Coefficients of Utilization 20% 30% 50 30 10
101 86 73 63 55 49 44 39 36 33 30
95 86 77 69 62 57 52 48 44 41 39
95 84 73 65 57 52 47 42 39 36 33
95 82 70 61 53 47 42 38 35 32 29
Lumens 3015 4377 6513 7608 8408
%Lamp 34 3 49 7 74 0 86 5 95 5
%Fixture 35 9 52 1 77 5 90 5 100 0
Coefficients of Utilization Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
97 89 81 74 67 61 56 52 48 44 41
97 85 74 65 58 51 45 41 36 33 30
97 82 69 59 51 44 38 33 29 26 23
HB-454T5-G-UNV-EBT2-UPL Electronic Ballasts (4) F54T5/830 HO lamps 4400 lumens Spacing criterion: (II) 1 3 x mounting height, (⊥) 1 3 x mounting height Efficiency 82 1% Test Report: HB454T5GUPL IES
97 79 64 54 45 38 33 28 24 21 18
88 78 69 61 54 47 42 38 34 31 28
88 76 65 56 48 41 36 32 28 25 22
Lumens 3436 5677 10418 13546 14453
108 96 85 75 67 60 54 49 45 41 38
108 108 92 89 79 74 68 62 59 53 52 46 46 41 42 36 38 32 34 29 31 27
98 87 77 69 62 55 50 46 42 39 36
98 85 73 63 56 49 44 39 36 33 30
20% 30% 50 30 10
98 83 69 59 51 44 39 35 31 28 26
92 82 73 65 58 53 48 44 40 37 34
92 80 70 61 53 47 42 38 35 32 29
92 78 66 57 49 43 38 34 31 28 25
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Lumens 3567 5750 9326 11066 12260
%Lamp 27 0 43 6 70 7 83 8 92 9
%Fixture 29 1 46 9 76 1 90 3 100 0
Coefficients of Utilization 20%
88 74 61 51 44 37 32 28 24 20 18
30% 50 30 10 84 74 65 58 51 45 40 36 33 29 27
84 72 62 53 46 40 35 31 27 24 21
%Lamp 19 5 32 3 59 2 77 0 82 1
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
84 70 59 50 43 36 31 27 23 20 18
110 102 93 86 79 73 68 64 59 56 52
110 98 86 77 69 62 57 52 48 44 41
110 110 94 91 81 76 70 65 61 56 55 49 49 43 44 39 40 35 37 32 34 29
HB-454T5-UNV-EBT2-UPL Electronic Ballasts (4) F54T5/835 HO lamps 4400 lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 0 8 x mounting height Efficiency 93 6% Test Report: HB454T5UPL IES
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
108 100 92 84 77 71 66 61 57 53 50
HB-354T5-UNV-EBT2-UPL Electronic Ballasts (3) FP54/835/HO lamps 4400 lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 1 3 x mounting height Efficiency 92 9% Test Report: HB354T5UPL IES
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
%Fixture 23 8 39 3 72 1 93 7 100 0
101 90 80 72 64 58 53 49 45 42 39
20%
101 101 88 85 76 72 66 62 58 54 52 47 47 42 43 38 39 34 36 31 33 29
30% 50 30 10 95 86 76 68 62 56 51 47 44 40 38
95 83 73 64 57 51 46 41 38 35 32
95 82 70 60 52 46 41 37 34 31 28
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Lumens 5656 8411 13046 15460 16480
%Lamp 32 1 47 8 74 1 87 8 93 6
%Fixture 34 3 51 0 79 2 93 8 100 0
Illuminance Estimator
Spacing on Center 15 ft 20 ft 25 ft 30 ft
15 ft FC LPD 51 0.8 34 0.55 23 0.35 13 0.2
20 ft FC LPD 47 0.8 33 0.55 21 0.35 12 0.2
25 ft FC LPD 44 0.8 31 0.55 20 0.35 11 0.2
30 ft FC LPD 41 0.8 29 0.55 18 0.35 10 0.2
Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD) Based on 100 ft. x 100 ft. Open Areas HB 4L 32W T8 PLUS
35 ft FC LPD 38 0.8 27 0.55 17 0.35 10 0.2
Mounting Height
Mounting Height
Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD) Multiplier Based on 100 ft. x 100 ft. Open Areas 2L 54W T5HO 0.50 HB 4L 54W T5HO 3L 54W T5HO 0.75
Spacing on Center 15 ft 20 ft 25 ft 30 ft
15 ft FC LPD 37 0.39 26 0.27 17 0.17 9 0.1
20 ft FC LPD 34 0.39 24 0.27 15 0.17 9 0.1
25 ft FC LPD 32 0.39 22 0.27 14 0.17 8 0.1
Multiplier 2L 32W T8 0.50 3L 32W T8 0.75
30 ft FC LPD 30 0.39 21 0.27 13 0.17 7 0.1
35 ft FC LPD 28 0.39 19 0.27 12 0.17 7 0.1
Choose the spacing and mounting height to determine the average footcandle and watts per square foot values. Use the multipliers to factor other available lamp/ballast configurations.
System Performance Table
Wattage
Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh
HB-332-EB8/PLUS
3
3100
94%
89%
1.15
8947
1.95
1.40
12494
101
$2.53
127
HB432 or HB432PS-EB81/PLUS
4
3100
94%
89%
1.15
11930
1.95
1.40
16659
147
$2.76
116
HB-354T5-EBT1
3
5000
93%
93%
1.00
12960
1.90
1.38
17864
182
$3.51
91
HB454T5 or HB454T5-EHT
4
5000
93%
94%
1.00
17410
1.90
1.38
23997
229
$3.26
98
250W Metal Halide High Bay
1
20800
58%
78%
1.00
9422
1.50
1.22
11540
295
$10.47
31
250W High Pressure Sodium High Bay
1
30000
81%
78%
1.00
18978
0.62
0.79
14944
300
$8.23
39
400W Metal Halide High Bay
1
36000
58%
78%
1.00
16307
1.50
1.22
19972
455
$9.33
34
400W High Pressure Sodium High Bay
1
50000
81%
78%
1.00
31631
0.62
0.79
24906
464
$7.63
42
HB System Comparison
No of Lamps
Design S/P Lamp Lumen Fixture Ballast System S/P Brightness Adjusted Lumens Maintenance1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4
LER5
Comparison System
FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 5000K lamps 5 LER (Luminaire Efficiency Ratio) is an accepted method of comparing fixture performance
14
I5/I8
H I G H - B AY I N D U S T R I A L L U M I N A I R E
Specification grade full body housing, end plates and socket tracks are die formed 20 gauge cold rolled steel in 4' or 8' lengths. Surface or suspension mounting (cable, chain, pendant mount or top connector box). Optional uplight apertures (approximately 8% uplight) Latched retention of optics (safety leader restraints) allows for easy access.
Thermally optimized F-Bay is suitable for environments up to 149°F (65°C) when used with high temperature environment ballasts. T5 systems are warranted for ambient environments up to 149°F (65°C) for three years and 131°F (55°C) for five years in open uplight configurations. T8 systems are warranted for environments up to 122°F (50°C) for five years.
Narrow 11" I5 and I8 housing allows mounting within 12" horizontally from the nearest edge of the sprinkler detector.
Optional modular power receptacle meets UL2459 and NEC 410.73 and is UL/cUL rated for make and break under load from outside the luminaire to speed maintenance.
Optical modules are fully enclosed inside housing to protect against damage. Die formed reflectors are faceted for 2, 3, 4, 6 and 8 lamp tandem configurations with two optical distributions medium and wide. Medium beam optical modules utilize 95% specular Miro 4 substrate while the wide distribution utilizes a high performance 95% reflective polyester powder coated finish. Integral occupancy sensor available and provides from 600 sq. ft. (MS) up to 1250 sq. ft. (MSO) of coverage at a maximum mounting height of 40'.
Modular F-Bay Power Supply
Cooper Lighting’s F-Bay Modular Power Supply option allows external fixture access for safe and easy servicing. There is no need to remove lamps or reflectors to disconnect fixture power with F-Bay Modular Power Supply. Access to the individual fixture’s power supply allows servicing without turning off all the fixtures disrupting occupants. F-Bay Modular Power Supply is a time saver in installation – simply plug & power. Code Compliance • UL/cUL Certified for Make/Break under load (UL2549) • Meets NEC requirements for ballast disconnect (NEC 410.73G) 1
1. Modular Power Supply Receptacle supplied mounted into fixture Access Plate 2. Modular Power Cord & Plugs in 120, 277, 347, & 480V configurations for easy plug & power into existing supply
15
• Allows for addition of Occupancy Sensor without hard connections
2 No internal fixture access required for installation or disconnecting power
Modular Motion Sensor Option supplied with Mounting Box and Modular Power Supply Receptacle
• Receptacles complete with insulating/dust cap
Shielding Options
Heavy duty wireguard finished in white Can be used alone or in combination with other shielding
Frosted acrylic or clear lens & frame (use with general distribution reflector, I5 only)
Thin blade white baffle w/23° longitudinal shielding
Asymmetric directional louver can be oriented in either direction for flexibility
Mounting Accessories
TCB=Top Connector Box
FH-1=Fixture Hook 2-1/2" FL-1=Fixture Loop 2-1/2" RH-1=Retrofit Hanger (must be used with TCB) (must be used with TCB) (must be used with TCB)
Row Mount
SC-_-_=Stem Sets (fixed, Swivel or Adjustable SCF=Fixed SCA=Adjustable SCS=Swivel
AYC-Mounting chain set
LOOP=Loop Hanger, TOGGLE=Single Toggle, #2 Cable #2 Cable
End plates provided with the “Quick-Tab” joining system for ease of row mounting Blank end plates provided for row ends
Dimensions I5/I8 Lamp Configurations
Dimensions for Top View
2-Lamp
3-Lamp
4-15/16" [126mm]
4-15/16" [126mm] 4-5/8" [118mm]
4-15/16" [126mm] X
X=2-3/4" [70mm]
11" [280mm]
Access Plate 11/16" [18mm] K.O. for Cable or Pendant Mounting
11/16" [18mm] K.O. for Cable or Pendant Mounting
4-Lamp
X
X=2-11/32" [60mm]
11" [280mm]
X
X
11" [280mm]
X
11" [280mm]
I5: 46" [1168mm] 92" [2337mm]
I8: 48" [1219mm] 96" [2438mm]
2-3/4" [70mm]
System Performance
I5
8TI5
I8
8TI8
Mounting Height
40' 400W MH
400W HPS
1000W MH
1000W HPS
1000W MH
1000W HPS
58%
58%
9%
26%
30' 250W MH
250W HPS
400W MH
400W HPS
400W MH
400W HPS
20' 250W MH
250W HPS
10' Energy Savings
38%
39%
50%
% Light Gain/Loss
36%
17%
16% -4%
Part Number
I5355
I5455
52%
24%
25%
58%
58%
66%
45%
31%
9%
26%
13% -13%
15% -14%
I8-332-EB81/PLUS
I8-432-EB81/PLUS
8TI5-354T5-EBT2
T5
8TI5-454T5-EBT3
T5
78%
T8
51%
51%
8TI8-432-EB83/PLUS
T8
% light gain/light loss utilize S/P adjusted lumens.
16
I5/I8
Ordering Information
H I G H - B AY I N D U S T R I A L L U M I N A I R E
Sample Number: 8TI5-254T5-TBW-120V-EBT1-UPL-U
Length Blank=4' Length 8T=8' Length Series I5=T5 Industrial I8=T8 Industrial Mounting Arrangement Blank=Stand Alone R=Continuous Row Mount No of Lamps 2=2 Lamps 3=3 Lamps 4=4 Lamps Lamp Type 28T5=28W T5 Std (4') Lamps 54T5=54W T5HO (4') Lamps 32=32W T8 (4') Lamps Distribution Optic Blank=Medium (Specular Aluminum) G=Wide (High Reflectance White)
Voltage (3) UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage 120V=120 Volt 277V=277 Volt 347V=347 Volt 480V=480 Volt
Ballast Type T5 Systems EBT =T5 Linear Electronic Program Rapid Start (4) Total Harmonic Distortion < 10% No of Ballast 1, 2 or 3 EHT =T5 Linear Electronic Start High Ambient (8) (9) Total Harmonic Distortion < 10% No of Ballast 1, 2 or 3
Options I5 Lamps Installed L5830=T5 Lamp, 85CRI 3000K L5835=T5 Lamp, 85CRI 3500K L5841=T5 Lamp, 85CRI 4100K L5850=T5 Lamp, 85CRI 5000K I8 Lamps Installed L8830=T8 Lamp, 85CRI 3000K L8835=T8 Lamp, 85CRI 3500K L8841=T8 Lamp, 85CRI 4100K L8850=T8 Lamp, 85CRI 5000K GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (3) (see table on pg 36)
T8 Systems EB8 =T8 Electronic Instant Start (5) Total Harmonic Distortion < 10% No of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Instant Start (5) High Ballast Factor >1 15 No of Ballast Total Harmonic Distortion < 10% 1, 2 or 3 ER8 =T8 Electronic Program Rapid Start (5) Total Harmonic Distortion < 10% No of Ballast 1, 2 or 3 ER8 /PLUS= T8 Electronic Program Start High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 1, 2 or 3
Shielding Options Blank=Open TBW=Thin White Baffle FL=Frosted Acrylic Lens & Frame (2) CL=Clear Acrylic Lens & Door Frame ASY= Asymmetric Directional Louver (2) WG=Heavy Duty Wireguard
DIM=Dimming NOTES: (1) Requires use of MC or MPC cord accessories, specify voltage for plugs (2) Use with wide distribution optic only (3) Voltage must be specified when ordered with plugs, motion or emergency ballasts (4) EBT ballast systems suitable for operation in ambient environments up to 104°F (40°C) (5) ER8 and EB8 ballast systems suitable for operation in ambient environments up to 122°F (50°C) in open uplight configurations (6) Specify voltage (7) For use with Top Connector Box options See accessories (8) 2 lamp ballast configurations only in UNC High Ambient versions (9) EHT ballast systems suitable for ambient environments not to exceed 149°F (65°C) in open uplight configurations and less lens option (10) TAP option available with a maximum of two ballasts, including EM battery pack (11) Not for use in gymnasiums or similar recreational facilities
Stock Catalog Items I5455=4 lamp, 54W T5HO, Program Rapid Start Ballast, Top Connector Plate, Uplight, 850 Lamps Installed I5355=3 lamp, 54W T5HO, Program Rapid Start Ballast, Top Connector Plate, Uplight, 850 Lamps Installed
System Performance Tables
Packaging Options U=Unit Pack NUA=No Uplight Apertures In Housing PAL=Palletized (Cannot be combined w/UPL) Out of Carton UPL=Uplight Apertures PALC=Palletized PI/CPI=Plug-In (1, 2 or 3) See pg 40 In Carton TILW=Tandem Inline Wiring MWS=Modular Wiring System (6) MS=Aisle Coverage Motion Sensor MSO=360° Coverage Motion Sensor (6) C3=3' Power Cord C6=6' Power Cord MP=Modular Power Receptacle (1) (3) PC3-=3' Power Cord & Plug (Specify Voltage) TAP=Top Access Plate (10) TCBP=Top Connector Box Plate (7) Accessories (order separately) TCB=Top Connector Box RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop SHK=Hook w/ Safety Screw PC3-=3' Power Cord & Plug (Specify Voltage) PC6-=6' Power Cord & Plug (Specify Voltage) AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-Hooks (11) GRIPPLE TOGGLE- =Single Toggle, #2 Cable (Specify 10' or 30') GRIPPLE LOOP- =Loop Hanger, #2 Cable (Specify 10' or 30') MC6=6' Modular Power Cord MPC6=6' Modular Power Cord & Plug (Specify Voltage) MMS-CPD1200H=Aisle Motion Sensor, Box, Modular Power Receptacle (120/277V) MMS-CPD500H=360° Motion Sensor, Box, Modular Power Receptacle (120/277V) Door Frames (for Field Installation) I5-FRM/LENS=Frosted Acrylic Lens & Frame (I5) I8-FRM/LENS PK=Frosted Acrylic Lens & Frame (I8) I5-FRM/CL PK=Clear Acrylic Lens & Frame (I5) I8-FRM/CL PK=Clear Acrylic Lens & Frame (I8) WG/I5-4FT-B=Heavy Duty Wireguard (I5) WG/I8-4FT-B=Heavy Duty Wireguard (I8) 90800PPK=Thin White Blade Baffle (I5) BAFFLE 4FT I8=Thin White Blade Baffle (I8) 90801PPK=Asymmetrical Directional Louver
Wattage
Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh
I5355
3
5000
93%
94%
1.00
13113
1.90
1.38
18075
182
$3.43
93
I5455
4
5000
93%
93%
1.00
17298
1.90
1.38
23844
229
$3.30
97
8TI5355
6
5000
93%
94%
1.00
26282
1.90
1.38
36227
346
$3.24
99
250W Metal Halide High Bay
1
20800
58%
78%
1.00
9422
1.50
1.22
11540
295
$10.47
31
250W High Pressure Sodium High Bay
1
30000
81%
78%
1.00
18978
0.62
0.79
14944
300
$8.23
39
400W Metal Halide High Bay
1
36000
58%
78%
1.00
16307
1.50
1.22
19972
455
$9.33
34
400W High Pressure Sodium High Bay
1
50000
81%
78%
1.00
31631
0.62
0.79
24906
464
$7.63
42
8
5000
93%
94%
1.00
35042
1.90
1.38
48303
458
$3.22
99
1
102800
45%
78%
1.00
36083
1.50
1.22
44192
1085
$10.07
32
LER5
I5 System Comparison
No of Lamps
Design S/P Lamp Lumen Fixture Ballast System S/P Brightness Adjusted Lumens Maintenance1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4
LER5
Comparison System
8I5 Comparison System 8TI5-454T5 Comparison System 1000W Metal Halide High Bay
Wattage
Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh
I8-332-EB8/PLUS
3
3100
94%
94%
1.15
9450
1.95
1.40
13196
101
$2.27
141
I8-432-EB8/PLUS
4
3100
94%
94%
1.15
12600
1.95
1.40
17595
147
$2.47
129
250W Metal Halide High Bay
1
20800
58%
78%
1.00
9422
1.50
1.22
11540
295
$10.47
31
250W High Pressure Sodium High Bay
1
30000
81%
78%
1.00
18978
0.62
0.79
14944
300
$8.23
39
400W Metal Halide High Bay
1
36000
58%
78%
1.00
16307
1.50
1.22
19972
455
$9.33
34
400W High Pressure Sodium High Bay
1
50000
81%
78%
1.00
31631
0.62
0.79
24906
464
$7.63
42
8
3100
94%
94%
1.15
25200
1.95
1.40
35190
302
$2.54
126
1
102800
45%
78%
1.00
36083
1.50
1.22
44192
1085
$10.07
32
I8 System Comparison
No of Lamps
Design S/P Lamp Lumen Fixture Ballast System S/P Brightness Adjusted Lumens Maintenance1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4
Comparison System
8I8 System Comparison 8I8-432-EB8/PLUS Comparison System 1000W Metal Halide High Bay
FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 5 LER (Luminaire Efficiency Ratio) is an accepted method of comparing fixture performance
17
Photometrics Coefficients of Utilization Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
109 101 93 86 80 73 68 63 59 54 51
109 97 87 78 70 63 57 52 47 43 39
I5-454T5-UNV-EBT2-UPL (2) Electronic Ballasts (4) 54W T5 lamps 4400 lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 0 8 x mounting height Efficiency 92 8% Test Report: 236P118
109 109 94 91 81 77 71 66 63 57 55 50 49 44 44 39 40 34 35 30 32 27
Coefficients of Utilization 20% 30% 50 30 10
100 100 100 90 87 85 80 76 73 72 67 63 65 60 55 59 53 48 54 47 43 49 43 38 44 38 34 40 34 30 37 31 27
94 85 76 69 63 56 51 47 43 39 36
94 83 73 65 58 51 46 41 37 33 30
94 81 70 61 54 47 42 37 33 29 26
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Lumens 5508 8329 12731 15217 16330
%Lamp 31 3 47 3 72 3 86 5 92 8
%Fixture 33 7 51 0 78 0 93 2 100 0
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
115 107 99 91 85 78 73 68 63 58 54
115 103 92 83 74 67 61 55 50 46 42
I5-354T5-UNV-EBT2-UPL (2) Electronic Ballasts (3) F54T5/HO/830K lamps 4400 lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 0 7 x mounting height Efficiency 98 2% Test Report: 236P108
115 115 100 97 86 81 76 70 67 61 59 53 53 47 48 42 43 37 38 33 35 30
30% 50 30 10
105 105 105 95 92 90 85 81 77 77 71 67 69 63 59 63 56 51 57 51 46 52 46 41 48 41 37 44 37 33 40 34 29
Lumens 4637 6733 10058 12070 12966
99 90 81 73 66 60 55 50 46 42 39
%Lamp 35 1 51 0 76 2 91 4 98 2
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
110 101 92 85 78 72 66 62 58 54 51
110 97 85 75 67 60 54 50 45 42 39
I8-332-UNV-EB81-UPL Electronic Ballast F32T8/TL835 Lamps 3000 lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 1 1 x mounting height Efficiency 94 1% Test Report: 236P188C
110 110 93 90 79 74 68 62 59 53 52 46 46 41 42 36 38 32 34 29 32 27
100 89 78 69 62 56 51 46 43 39 37
100 86 74 64 56 49 44 40 36 33 30
99 88 77 69 61 55 49 45 40 36 33
99 86 74 65 57 50 45 40 36 32 29
%Fixture 35 8 51 9 77 6 93 1 100 0
Lumens 2530 3885 6299 7803 8468
95 80 67 58 50 44 39 35 31 27 24
87 78 70 63 57 52 47 43 39 36 33
87 76 67 59 52 46 42 38 34 30 27
87 74 63 55 48 42 38 34 30 26 24
82 74 66 60 55 49 45 41 38 34 32
82 72 64 57 51 45 40 37 33 29 27
82 71 61 54 47 41 37 33 29 26 23
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
110 102 95 88 81 75 70 65 60 56 53
110 99 88 79 71 64 59 54 49 45 41
I5-354T5-TBW-UNV-EBT2-UPL (2) Electronic Ballasts (3) F54T5/HO lamps 4400 lumens Spacing criterion: (II) 1 0 x mounting height, (⊥) 0 7 x mounting height Efficiency 94 2% Test Report: 236P107
Lumens 4945 7390 11071 13159 14293
%Lamp 28 1 42 0 62 9 74 8 81 2
%Fixture 34 6 51 7 77 5 92 1 100 0
110 110 95 92 83 78 73 68 64 59 57 51 51 46 46 41 42 37 37 33 34 29
100 90 81 73 66 60 55 50 46 42 39
100 88 77 68 61 54 49 44 40 36 33
20% 30% 50 30 10
100 86 74 64 57 50 44 40 36 32 29
94 85 77 70 63 58 53 48 44 41 37
94 83 74 66 59 52 47 43 39 35 32
94 82 71 62 55 48 43 39 35 31 28
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Lumens 4535 6495 9563 11373 12428
%Lamp 34 4 49 2 72 4 86 2 94 2
%Fixture 36 5 52 3 76 9 91 5 100 0
Coefficients of Utilization 20%
100 83 70 59 51 44 39 35 32 29 26
30% 50 30 10 95 84 74 66 59 53 48 44 42 38 35
95 82 70 61 54 48 43 39 35 32 30
%Lamp 28 1 43 2 70 0 86 7 94 1
%Fixture 29 9 45 9 74 4 92 1 100 0
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
95 80 67 57 49 43 38 34 31 28 26
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
95 82 71 63 55 49 44 39 35 31 28
30% 50 30 10
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
Coefficients of Utilization Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
95 85 76 68 61 55 50 46 41 38 35
20%
Coefficients of Utilization 20%
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
95 88 82 75 70 64 60 56 52 48 45
I5-454T5-TBW-UNV-EBT2-UPL (2) Electronic Ballasts (4) 54W T5 4400 lumens Spacing criterion: (II) 1 1 x mounting height, (⊥) 0 9 x mounting height Efficiency 81 2% Test Report: 236P112
Coefficients of Utilization Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
107 98 89 81 74 68 63 59 54 51 48
107 94 82 72 64 57 51 46 42 39 36
I8-432-UNV-EB81-UPL Electronic Ballast F32T8-TL835 lamps 3000 lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 1 3 x mounting height Efficiency 91 2% Test Report: 236P197C
107 107 90 87 76 71 65 59 56 50 49 43 43 37 39 33 35 29 31 26 29 24
98 86 75 66 59 53 48 43 40 37 34
98 83 71 61 53 46 41 37 33 30 28
20% 30% 50 30 10
98 81 67 56 48 41 36 32 29 26 23
92 81 71 63 56 50 46 42 38 35 33
92 79 68 58 51 45 40 36 32 29 27
92 77 64 54 46 40 35 31 28 25 23
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Lumens 2861 4657 8121 10169 10943
%Lamp 23 8 38 8 67 7 84 7 91 2
%Fixture 26 1 42 6 74 2 92 9 100 0
Illuminance Estimator Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD) Based on 100 ft. x 100 ft. Open Manufacturing Area
Mounting Height
Spacing on Center 15 ft 20 ft 25 ft
15 ft FC LPD 45 0.75 31 0.52 20 0.33
20 ft FC LPD 42 0.75 29 0.52 19 0.33
25 ft FC LPD 39 0.75 27 0.52 17 0.33
30 ft FC LPD 36 0.75 25 0.52 16 0.33
35 ft FC LPD 34 0.75 24 0.52 15 0.33
Multiplier 6L 32W T8 1.5
I8 4L 32W T8 w/Uplight
Mounting Height
Multiplier 6L 54W T5HO 1.5
I5 4L 54W T5HO
Spacing on Center 15 ft 20 ft 25 ft
15 ft FC LPD 36 0.4 25 0.28 16 0.18
20 ft FC LPD 33 0.4 23 0.28 15 0.18
25 ft FC LPD 30 0.4 21 0.28 14 0.18
30 ft FC LPD 28 0.4 20 0.52 13 0.33
35 ft FC LPD 26 0.4 18 0.28 12 0.18
Choose the spacing and mounting height to determine the average footcandle and watts per square foot values. Use the multipliers to factor other available lamp/ballast configurations.
18
MB
M I C R O - B AY L U M I N A I R E
UL/cUL listed to meet U.S. and Canadian standards. Suspension is convenient and flexible with the SS Aircraft Cable “Y” Toggle Mounting Kits. Adjustment for luminaire mounting height is provided at luminaire rather than structure. Cable Mounting Kit
Specular Miro reflectors for precise light control minimum 95% total reflectivity. Three optical distribution patterns are available: Focus - SC < .9 Task - .9 ≤ SC < 1.2 Normal - 1.2 ≤ SC ≤ 1.4
Dimensions Dimensions for Top View 4' and 8'
Rigid exterior connector/coupling with pre-punched holes facilitates easy installation of coupled sections up to 32' long.
7/8" [23mm] K.O. (3) Ceiling Stand-Off Embossments
1-3/4" x 3-1/4" K.O. (1) Ground Screw Bump
2-11/16" [69mm] (4’) 43-3/4" [1112mm]
(8’) 91-3/4" [2330mm]
(4’) 48" [1220mm]
(8’) 96" [2438mm]
T5 Lamp Configurations
Integral occupancy sensor available and provides from 600 sq. ft. up to 1250 sq. ft. of coverage in a maximum mounting height of 40'.
Focus Beam 1 or 2 Lamp X
Rigid Exterior Connector
Optional pre-wired factory installed multiple circuit plug-in connectors.
1-31/32" [51mm]
3-9/32" [84mm] X=2-11/16" [69mm]
1" [26mm] 4-5/16" [110mm]
Normal Beam 1 or 2 Lamp X 1-31/32" [51mm]
3-9/32" [84mm]
Plug-In Connectors
Occupancy Sensor
MB Ordering Information
Sample Number (T5): MB-154T5-FB-UNV-EBT1-U
(T8): MB-132-NB-UNV-EB81-U
X=2-11/16" [69mm]
1-3/16" [31mm] 4-5/16" [110mm]
Task Beam 1 or 2 Lamp X
Tandem Blank= 4' Length 8T= 8' Length Series MB= Micro-Bay Number of Lamps (Not included)
1=1 Lamp 2=2 Lamps Lamp Types 32=32W T8 (48") 54T5=54W T5HO (48") Reflector FB=Concentrated Focus Beam TB=Medium Task Beam NB=Wide Normal Beam Voltage UNV=Universal 120-277 Voltage UNC=Universal 347/480 Voltage Options GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (see table on pg 36) (2)
19
Ballast Type (1) T5 Systems EBT =T5 Linear Electronic Program Rapid Start Total Harmonic Distortion < 10% No of Ballast 1 or 2 EHT =T5 Linear Electronic Program Rapid Start High Ambient Total Harmonic Distortion < 10% (4) No of Ballast 1 or 2 T8 Systems EB8 =T8 Electronic Instant Start (5) Total Harmonic Distortion < 10% No of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start (5) High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start (5) Total Harmonic Distortion < 10% No of Ballast 1 or 2 ER8 /PLUS= T8 Electronic Program Start (5) High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 1 or 2 DIM=Dimming
Options Packaging PI/CPI=Plug-In (1, 2 or 3) U=Unit Pack See pg 40 C3=3' Power Cord C6=6' Power Cord PC3-=3' Power Cord & Plug (Specify Voltage) (3) PC6-=6' Power Cord & Plug (Specify Voltage) (3)
1-31/32" [51mm]
3-9/32" [84mm] X=2-11/16" [69mm]
1-7/16" [37mm] 4-5/16" [110mm]
T8 Lamp Configurations Focus Beam 1 or 2 Lamp
Accessories (order separately) AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-Hooks GRIPPLE-Y- =Y Mounting Toggle, #2 Cable (Specify 10' or 30') GRIPPLE-TOGGLE- =Single Toggle, #2 Cable (Specify 10' or 30') MB-EXT-LONG-CONN-KIT-U=Rigid Connector Support for Continuous Channel Installation MS=Aisle Coverage Motion Sensor (3) (6) MSO=360° Coverage Motion Sensor (3) (6) MB-SENSOR-KIT-CTR/MT-U=Aisle Coverage Motion Sensor, Center Mount Hardware, 120/277V MB-SENSOR-KIT-END/MT-U=Aisle Coverage Motion Sensor, End Mount Hardware, 120/277V MB-SENSOR-KIT-CTR/480V-U=Aisle Coverage Motion Sensor, Center Mount Hardware, 480V MB-SENSOR-KIT-END/480V-U=Aisle Coverage Motion Sensor, End Mount Hardware, 480V WG/MB-4FT-T5-NB-B=Wireguard for T5HO (7)
NOTES: (1) Products also available in non-US voltages and frequencies for international markets (2) Voltage to be specified with emergency ballast option (3) Voltage must be specified when ordered with plugs, motion or emergency ballasts (4) 2 lamp ballast configurations only in UNC versions (5) ER8 and EB8 ballast systems suitable for operation in ambient environments up to 50°C (6) Must ship as accessory separately (7) For use with T5HO Focus, Normal or Wide Beam optics only
X
29/32" [24mm]
5-11/16" [145mm]
X=2-11/16" [69mm]
9-1/16" [231mm]
Normal Beam 1 or 2 Lamp X 3-5/32" [81mm] X=2-11/16" [69mm]
29/32" [24mm] 7-3/32" [181mm]
Task Beam 1 or 2 Lamp X 3-5/32" [81mm] X=2-11/16" [69mm]
29/32" [24mm] 7-9/16" [193mm]
Photometrics Coefficients of Utilization Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
⊥
||
112 101 92 84 76 70 65 60 56 52 49
112 97 84 73 65 58 52 47 43 40 37
112 112 92 88 77 71 65 59 56 50 49 43 43 37 39 33 35 29 32 26 29 24
MB-132-NB-UNV-EB81 Electronic Ballast (1) 32WT8 Lamp 2850 lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 1 2 x mounting height Efficiency 94 1% Test Report: 10267
105 90 78 69 61 55 49 45 41 38 35
105 87 73 62 54 47 42 38 34 31 28
Coefficients of Utilization 20% 30% 50 30 10
105 84 69 57 49 42 37 32 29 26 24
100 87 75 66 59 53 48 44 40 37 34
100 84 71 61 53 46 41 37 34 31 28
100 81 67 56 48 41 36 32 29 26 24
||
Lumens 722 1133 2012 2679 2682
%Lamp 25 3 39 8 70 6 94 0 94 1
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10 113 102 93 84 77 70 65 60 56 53 49
113 97 84 73 65 58 52 47 43 40 37
113 113 93 89 77 71 65 59 56 49 49 42 43 37 39 33 35 29 32 26 29 24
MB-132-TB-UNV-EB81 (1) Electronic Ballast (1) 32W T8 lamps 2850 lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 1 0 x mounting height Efficiency 95 1% Test Report: 10266
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
%Fixture 26 9 42 3 75 0 99 9 100 0
106 91 79 69 61 55 49 45 41 38 35
106 88 73 62 54 47 42 37 34 31 28
20% 30% 50 30 10
106 85 69 57 48 42 36 32 29 26 24
101 87 76 66 59 53 48 43 40 37 34
101 84 71 61 53 46 41 37 33 30 28
101 82 67 56 48 41 36 32 29 26 23
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Lumens 700 1104 2001 2707 2711
%Lamp 24 6 38 7 70 2 95 0 95 1
%Fixture 25 8 40 7 73 8 99 9 100 0
Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
System Performance
MB 2 LAMP T12 1 LAMP T12 HO
8TMB
2 LAMP T12 1 LAMP T12 HO
Energy Savings
56%
61%
48%
55%
56%
61%
% Light Gain/Loss
38%
37%
23%
22%
38%
37%
Part Number
||
2 LAMP T12 1 LAMP T12 HO
MB-232-FB-EB81
MB-154T5-FB-EBT1
8TMB-232-FB-EB81
T8
T5
T8
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10 109 99 91 83 76 70 65 60 56 53 50
109 95 83 73 65 58 53 48 44 41 38
109 109 91 88 77 72 66 60 57 51 50 44 45 39 40 35 36 31 33 28 31 26
MB-132-FB-UNV-EB81 (1) Electronic Ballast (1) 32W T8 lamps 2850 lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 0 9 x mounting height Efficiency 91 4% Test Report: 09512
101 89 78 69 62 55 50 46 42 39 36
101 86 73 63 55 49 43 39 36 33 30
101 84 69 58 50 44 38 34 31 28 26
20% 30% 50 30 10 97 86 75 66 59 54 49 45 41 38 35
97 83 71 61 54 48 43 39 35 32 30
97 81 68 57 49 43 38 34 31 28 26
Zonal Lumen Summary 0-30 0-40 0-60 0-90 0-180
787 1211 2048 2599 2604
27 6 42 5 71 9 91 2 91 4
30 2 46 5 78 7 99 8 100 0
% light gain/light loss utilize S/P adjusted lumens.
Illuminance Estimator Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD) Based on 120 ft. x 10 ft. Aisle
Micro-Bay
20 ft MB-132-NB MB-154-NB MB-232-FB MB-254-FB
Qty 30 17 16 11
FC 31 31 31 32
25 ft LPD 0.8 0.84 0.76 0.99
Qty 38 21 19 13
FC 32 31 30 31
30 ft LPD 1.01 1.03 0.90 1.17
Qty 44 24 23 16
FC 31 35 31 32
35 ft LPD 1.17 1.18 1.09 1.44
Qty 52 28 26 18
FC 31 30 30 31
40 ft LPD 1.39 1.38 1.24 1.62
Qty 58 32 30 20
FC 30 30 30 30
LPD 1.55 1.57 1.43 1.80
Choose the spacing and mounting height to determine the average footcandle and watts per square foot values.
System Performance Table
Wattage
Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh
MB-232-FB-EB81
2
3100
94%
95%
1.00
5542
1.95
1.40
7740
56
$2.43
MB-154T5-FB-UNV-EBT1
1
5000
93%
98%
1.00
4543
1.90
1.38
6262
65
$3.40
94
8TMB-232-FB-EB81
2
3100
94%
95%
1.00
5537
1.95
1.40
7731
56
$2.44
131
MB System Comparison
No of Lamps
Design S/P Lamp Lumen Fixture Ballast System S/P Brightness Adjusted Lumens Maintenance1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4
LER5
131
Comparison System (2) 34W T12 Strip
2
2750
88%
90%
0.90
3920
1.50
1.22
4801
126
$10.37
31
(1) 96" T12HO Strip
1
8630
58%
90%
0.88
3964
1.50
1.22
4855
145
$12.07
27
FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 5 LER (Luminaire Efficiency Ratio) is an accepted method of comparing fixture performance
20
3HBOT
H I G H - B AY I N D U S T R I A L L U M I N A I R E
Integral occupancy sensor available and provides from 600 sq. ft. up to 1250 sq. ft. of coverage at a maximum mounting height of 40'. Side rails are used to protect optical cavity and add rigidity.
Specification grade open body housing, end plates and socket tracks are die formed 20 gauge cold rolled steel.
Thermally optimized F-Bay is suitable for environments up to 122°F (50°C) when used with high temperature environment ballasts.
Pressure lock lampholders.
Optional modular power receptacle and cord sets meets UL2459 and NEC 410.73 and are UL/cUL rated for make and break under load from outside the luminaire.
Ordering Information
Sample Number: 3HBOT-832-UNV-EB82/PLUS-UPL-U
Width 3=32" wide Series HBOT=High Bay Open Top Version No of Lamps 8=8 Lamps Wattage (Length) 32=32W T8 Lamps (48") 54T5=54W T5HO Lamps (48") Distribution Blank=Medium (Specular Aluminum) G=Wide (White Painted)
Voltage (2) UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage(6) 120V=120 Volt 277V=277 Volt 347V=347 Volt 480V=480 Volt Options Lamps Installed L8830=T8 Lamp, 85CRI 3000K L8835=T8 Lamp, 85CRI 3500K L8841=T8 Lamp, 85CRI 4100K L8850=T8 Lamp, 85CRI 5000K L5830=T5 Lamp, 85CRI 3000K L5835=T5 Lamp, 85CRI 3500K L5841=T5 Lamp, 85CRI 4100K L5850=T5 Lamp, 85CRI 5000K GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (2) (see table on pg 36)
NOTES: (1)Requires use of MC or MPC cord accessories, specify voltage for plugs (2)Voltage must be specified when ordered with plugs, motion or emergency ballasts (3) EBT ballast systems suitable for operation in ambient environments up to 104°F (40°C) (4) Specify voltage on ballast (5) For use with Top Connector Box options See accessories (6) 2 lamp ballast configurations only in EHT-UNC versions (7) ER8 and EB8 ballast systems suitable for operation in ambient environments up to 122°F (50°C) in open uplight configuration
21
Die formed reflectors are faceted for 8 lamp configurations with two optical distributions medium and wide. Medium beam optical modules utilize 95% specular Miro 4 substrate while the wide distribution utilizes a high performance 95% reflective polyester powder coated finish.
Ballast Type T8 Systems EB8 =T8 Electronic Instant Start (7) Total Harmonic Distortion < 10% No of Ballast 2 or 3 EB8 /PLUS= T8 Electronic Instant Start (7) High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 2 or 3 ER8 =T8 Electronic Program Rapid Start (7) Total Harmonic Distortion < 10% No of Ballast 2 or 3 ER8 /PLUS= T8 Electronic Program Start (7) High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 2 or 3 T5 Systems EBT =T5 Linear Electronic Program Rapid Start Total Harmonic Distortion < 10% No of Ballast 2, 3 or 4 EHT =T5 Programmed Start High Ambient (6) Total Harmonic Distortion < 10% No of Ballast 2, 3 or 4 DIM=Dimming
Packaging Options UPL=Uplight Apertures U=Unit Pack PI/CPI=Plug-In (1, 2 or 3) PAL=Palletized See pg 40 Out of Carton TILW=Tandem Inline Wiring PALC=Palletized MWS=Modular Wiring System In Carton MS=Aisle Coverage Motion Sensor (4) MSO=360° Coverage Motion Sensor (4) MP=Modular Power Receptacle (1) (2) PC3-=3' Power Cord & Plug (Specify Voltage) (2) PC6-=6' Power Cord & Plug (Specify Voltage) (2) TCBP=Top Connector Box Plate (5)
(3)
Accessories (order separately) AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-Hooks TCB=Top Connector Box RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop MPC6=6' Modular Power Cord & Plug (Specify Voltage) MC6=6' Modular Power Cord MMS-CPD1200H=Aisle Motion Sensor, Box, Modular Power Receptacle (120/277V) MMS-CPD500H=360° Motion Sensor, Box, Modular Power Receptacle (120/277V)
Photometrics
Illuminance Estimator Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD) Based on 100 ft. x 100 ft. Open Area
Coefficients of Utilization
106 100 93 87 81 75 70 65 61 56 52
106 97 88 80 73 66 60 55 50 45 41
3HBOT-854T5-UNV-EBT2-UPL (2) Electronic Ballasts (8) F54T5HO/841 54W T5 lamps 4500 lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 1 0 x mounting height Efficiency 90 3% Test Report: 3HB854T5UPL IES
106 106 94 92 84 80 74 70 67 62 59 54 54 49 48 44 43 39 39 34 35 30
98 90 82 75 69 62 57 52 48 43 40
98 88 79 71 64 57 52 47 42 37 34
98 86 76 67 60 53 48 43 38 33 30
30% 50 30 10 93 86 79 72 66 60 55 51 46 42 39
93 84 76 69 62 56 50 46 41 37 33
3HBOT 8L 54W T5HO w/Uplight
93 83 74 66 59 52 47 42 37 33 30
Lumens 13023 19856 28801 30819 32523
%Lamp 36 2 55 2 80 0 85 6 90 3
15 ft FC LPD 57 0.91 36 0.58 20 0.33 9 0.15
20 ft FC LPD 53 0.91 34 0.58 19 0.33 9 0.15
25 ft FC LPD 50 0.91 32 0.58 18 0.33 8 0.15
30 ft FC LPD 47 0.91 30 0.58 17 0.33 8 0.15
35 ft FC LPD 45 0.91 29 0.58 16 0.33 7 0.15
40 ft FC LPD 42 0.91 27 0.58 15 0.33 7 0.15
3HBOT 8L 32W T8 w/Uplight
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Spacing on Center 20 ft 25 ft 30 ft 35 ft
Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD) Based on 100 ft. x 100 ft. Open Area
%Fixture 40 0 61 1 88 6 94 8 100 0
Mounting Height
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
20%
Mounting Height
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
Spacing on Center 20 ft 25 ft 30 ft 35 ft
15 ft FC LPD 52 0.56 33 0.36 19 0.20 8 0.09
20 ft FC LPD 48 0.56 31 0.36 17 0.20 8 0.09
25 ft FC LPD 45 0.56 29 0.36 16 0.20 7 0.09
30 ft FC LPD 42 0.56 27 0.36 15 0.20 7 0.09
35 ft FC LPD 40 0.56 25 0.36 14 0.20 6 0.09
40 ft FC LPD 37 0.56 24 0.36 13 0.20 6 0.09
Choose the spacing and mounting height to determine the average footcandle and watts per square foot values.
System Performance
Dimensions
3HBOT
3HBOT Lamp Configurations 8-lamp
Mounting Height
40'
5-3/16" [131mm]
1000W MH
X=4" [102mm]
1000W MH
X
X
X
X
X
X
X
32-11/16" [830mm]
30' Dimensions for Top View 41-1/2" [1054mm]
20'
33" [838mm]
10' 7/8" KO (4)
Energy Savings % Light Gain/Loss Part Number
72%
58%
-18%
Top Connector Emboss
Ceiling Standoff Embossment
32-5/16" [820mm]
11/16" X 1" KO (2)
14%
3HBOT832EB/PLUS
3HBOT854T5EBT2
T8
T5 48" [1220mm]
% light gain/light loss utilize S/P adjusted lumens.
System Performance Table
Wattage
Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh
3HBOT-832-EB/PLUS
8
3100
94%
90%
1.15
24128
1.95
1.40
33693
302
$2.77
115
3HBOT-854T5-EBT2
8
5000
93%
90%
1.00
33480
1.90
1.38
46149
458
$3.53
91
1
102800
45%
70%
1.00
32382
1.50
1.22
39660
1085
$12.51
26
3HBO System Comparison
No of Lamps
Design S/P Lamp Lumen Fixture Ballast System S/P Brightness Adjusted Lumens Maintenance1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4
LER5
Comparison System 1000W Metal Halide High Bay
FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 5000K lamps 5 LER (Luminaire Efficiency Ratio) is an accepted method of comparing fixture performance
22
2HBG
R E C E S S E D H I G H - B AY I N D U S T R I A L L U M I N A I R E
Nominal 6-5/8" deep, para-contoured housing, die formed 20 gauge cold rolled steel.
Heavy gauge end plates, securely attached with interlocking tabs and screws.
Recessed mount for in standard grid/lay-in, concealed T, and slot grid ceilings. Flange trim with supporting swing gates conceal the edges of the ceiling opening.
End plates have integral Grid-Lock feature for safety and convenience. Housing features enable fixture to be converted from Grid to T-Option or vice-versa in the field. Die formed reflectors are faceted for 4 and 6 lamp configurations with two optical distributions medium and wide. Medium beam optical modules utilize 95% specular Miro 4 substrate while the wide distribution utilizes a high performance 95% reflective polyester powder coated finish.
Prismatic and clear lens with door frame option
Pressure lock lampholders.
Ordering Information
Sample Number: 2HBG-654T5-A-UNV-EBT2-U
Width 2=24" Series HB=High Bay Trim Type G=Grid/Lay-in (Standard) F=Flange Trim No of Lamps 4=4 Lamps 6=6 Lamps Lamp Type 32=32W T8 Lamps (48") 28T5=28W T5 Lamps (48") 54T5=54W T5HO Lamps (48") Distribution Optic Blank=Medium (Specular Aluminum) G=Wide (White Painted)
Voltage (1) UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage (T5 linear only) 120V=120 Volt 277V=277 Volt 347V=347 Volt Options Lamps Installed L8830=T8 Lamp, 85CRI 3000K L8835=T8 Lamp, 85CRI 3500K L8841=T8 Lamp, 85CRI 4100K L8850=T8 Lamp, 85CRI 5000K L5830=T5 Lamp, 85CRI 3000K L5835=T5 Lamp, 85CRI 3500K L5841=T5 Lamp, 85CRI 4100K L5850=T5 Lamp, 85CRI 5000K GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (1) (see table on pg 36)
Downlight Optic Blank=Open A=Prismatic Acrylic Lens & Steel Door Frame CL=Clear Acrylic Lens & Steel Door Frame
NOTES: (1) Voltage must be specified when ordered with emergency ballasts in ambient environments up to 122°F (50°C) without lens option
23
Packaging Ballast Type U=Unit Pack T8 Systems (2) PAL=Job Pack, out of carton EB8 =T8 Electronic Instant Start PALC=Job Pack, in carton Total Harmonic Distortion < 10% No of Ballast Accessories (order separately) 1 or 2 MWS=Modular Wiring System, EB8 /PLUS= T8 Electronic Instant Start (2) (Refer to MWS Catalog Online) High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start Total Harmonic Distortion < 10%(2) No of Ballast 1 or 2 ER8 /PLUS= T8 Electronic Program Start High Ballast Factor >1 15 (2) Total Harmonic Distortion < 10% No of Ballast 1 or 2 T5 Systems EBT =T5 or T5HO Linear Electronic Program Rapid Start Total Harmonic Distortion < 10% No of Ballast 1 or 2
Ceiling Compatibility G Grid/Lay-in Standard
(2) ER8
and EB8 ballast systems suitable for operation
F Flange Trim With Supporting Swing Gates
Ceiling Type
Trim Type
Exposed Grid Concealed T Slot Grid Flange
G G G F
Photometrics Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
⊥ ||
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10 99 91 82 75 69 63 58 54 50 47 44
99 87 76 66 59 53 47 43 39 36 33
99 83 70 59 51 45 40 36 32 29 26
2HBG-632-UNV-EB82 (2) Electronic Ballasts (6) F32T8/TL835 lamps 3000 lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 1 4 x mounting height Efficiency 83 4% Test Report: 2HBG632 IES
99 80 65 54 46 39 34 30 27 24 22
93 81 71 62 56 50 45 41 37 34 32
93 79 67 57 50 44 39 35 31 28 26
Coefficients of Utilization 20% 30% 50 30 10
93 76 63 53 45 39 34 30 27 24 22
89 78 68 60 54 48 44 40 36 34 31
89 76 65 56 48 43 38 34 31 28 26
89 74 61 52 44 38 34 30 27 24 22
||
⊥
Lumens 4174 6937 11814 15014 15014
%Lamp 23 2 38 5 65 6 83 4 83 4
88 81 74 68 63 58 54 50 47 44 41
88 78 68 61 55 49 45 41 37 35 32
88 75 64 55 48 43 38 35 32 29 27
2HBG-654T5-UNV-EBT2 (3) Electronic Ballasts (6) F54T5HO/841 lamps 4400 lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 1 1 x mounting height Efficiency 73 5% Test Report: 2HBG654T5 IES
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
%Fixture 27 8 46 2 78 7 91 5 100 0
System Performance
88 72 60 51 44 38 34 30 27 25 23
82 73 65 58 52 47 43 39 36 33 31
82 71 61 53 47 42 37 34 31 28 26
20%
82 69 58 50 43 38 34 30 27 25 23
30% 50 30 10 78 70 62 56 50 45 41 38 35 33 30
78 68 59 52 46 41 37 33 30 28 26
78 67 57 49 42 37 33 30 27 25 23
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Lumens 6821 10503 16195 19412 19412
%Lamp 25 8 39 8 61 3 73 5 73 5
%Fixture 35 1 54 1 83 4 100 0 100 0
Dimensions
2HBG
2HBG Lamp Configurations
Mounting Height
6-lamp
40'
4-5/8" [117mm] X=3-1/2" [89mm]
30' 400W MH
400W HID
400W MH
400W HID
20'
X
X
X
X
X
23-3/4" [603mm]
4-lamp 5-5/8" [143mm]
250W MH
250W HID
250W MH
250W HID 23-3/4" [603mm]
10' Dimensions for Top View Energy Savings % Light Gain/Loss Part Number
68%
-33%
68%
- 33%
2HBG-432-ER8/PLUS
51%
51%
50%
51%
24%
25%
11%
11%
3%
3%
35%
35%
2HBG-632-ER82/PLUS
2HBG-454-EBT1
T8
7/8" [22mm] K.O. (4)
Access Plate 7/8" [22mm] K.O. (2)
1-1/2" [38mm] 23-3/4" [603mm]
2HBG-654-EBT2
T5
% light gain/light loss utilize S/P adjusted lumens.
5-1/4" [133mm] 3-3/4" [95mm]
7-23/32" [196mm] 48" [1219mm]
System Performance Table
Wattage
Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh
2HBG-432-ER81/PLUS
4
3100
94%
80%
1.15
10724
1.95
1.40
14975
147
$3.41
94
2HBG-632-EB82/PLUS
6
3100
94%
80%
1.15
16085
1.95
1.40
22462
221
$3.42
94
2HBG-454T5-EBT1
4
5000
93%
80%
1.00
14880
1.90
1.38
20511
229
$4.47
72
2HBG-654T5-EBT2
6
5000
93%
80%
1.00
22320
1.90
1.38
30766
346
$4.50
71
250W Metal Halide High Bay
1
20800
58%
78%
1.00
9422
1.50
1.22
11540
295
$10.47
31
250W High Pressure Sodium High Bay
1
30000
81%
78%
1.00
18978
0.62
0.79
14944
300
$8.23
39
400W Metal Halide High Bay
1
36000
58%
78%
1.00
16307
1.50
1.22
19972
455
$9.33
34
400W High Pressure Sodium High Bay
1
50000
81%
78%
1.00
31631
0.62
0.79
24906
464
$7.63
42
2HBG System Comparison
No of Lamps
Design S/P Lamp Lumen Fixture Ballast System S/P Brightness Adjusted Lumens Maintenance1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4
LER5
Comparison System
FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 4100K lamps 5 LER (Luminaire Efficiency Ratio) is an accepted method of comparing fixture performance
24
HBHD
H O S E D O W N H I G H - B AY I N D U S T R I A L L U M I N A I R E
High performance white enamel finish improves efficiency and protects against elements. Optional brushed stainless steel finish for corrosive chemical environments.
Sealed housing is enclosed and gasketed to provide 800 psi hose down protection.
White, closed cell, Flexiseal™ gasketing surrounds perimeter of lens to seal lens to door frame and around perimeter of door to seal door to housing. Another layer seals fixture to ceiling system after installation. Product can be surface or suspension mounted.
One piece, heavy gauge extruded lens in prismatic clear acrylic. Captive, flush mounted stainless steel fasteners secure one piece door to housing. Die formed reflectors are faceted for 4 and 6 lamp configurations with two optical distributions medium and wide. Medium beam optical modules utilize 95% specular Miro 4 substrate while the wide distribution utilizes a high performance 95% reflective polyester powder coated finish. UL/cUL and CSA listed for wet locations. Manufactured in compliance with USDA, FDA, NSF and Federal Standard 209E in surface mount applications.
Ordering Information
Sample Number: 2HBHD-654T5-A-UNV-EBT2-U
Width 2=24" Series HBHD=High Bay Hose Down No of Lamps 4=4 Lamps 6=6 Lamps Lamp Type 32=32W T8 Lamps (48") 28T5=28W T5 Lamps (48") 54T5=54W T5HO Lamps (48") Distribution Blank=Medium (Specular Aluminum) G=Wide (High Reflectance White)
Shielding A=Prismatic Acrylic Lens & Door Frame CL=Clear Acrylic Lens & Door Frame Voltage (1) UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage (T5 linear only) (2) 120V=120 Volt 277V=277 Volt 347V=347 Volt 480V=480 Volt Options Lamps Installed L8830=T8 Lamp, 85CRI 3000K L8835=T8 Lamp, 85CRI 3500K L8841=T8 Lamp, 85CRI 4100K L8850=T8 Lamp, 85CRI 5000K L5830=T5 Lamp, 85CRI 3000K L5835=T5 Lamp, 85CRI 3500K L5841=T5 Lamp, 85CRI 4100K L5850=T5 Lamp, 85CRI 5000K GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (1) (see table on pg 36)
NOTES: (1) Voltage must be specified when ordered with plugs or emergency ballasts ordered separately, see accessories
25
(2) 2
Ballast Type (1) T8 Systems EB8 =T8 Electronic Instant Start Total Harmonic Distortion < 10% No of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start Total Harmonic Distortion < 10% No of Ballast 1 or 2 ER8 /PLUS= T8 Electronic Program Start High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 1 or 2 T5 Systems EBT =T5 Linear Electronic Program Rapid Start Total Harmonic Distortion < 10% No of Ballast 1, 2 or 3 EHT =T5 Linear Electronic Start High Ambient (2) Total Harmonic Distortion < 10% No of Ballast 1, 2 or 3 DIM=Dimming
lamp ballast configurations only in UNC versions
(3) Cord
Packaging Options (3) C3=3' Power Cord U=Unit Pack C6=6' Power Cord PAL=Pallet Pack PC3-=3' Power Cord & Plug PALC=Job Pack (1) (Specify Voltage) In Carton PC6-=6' Power Cord & Plug (Specify Voltage) (1) SSN=Stainless Steel Door/Brushed 304 Finish SHN=Stainless Steel Housing Brushed 304 Finish PM=Pendant Mount (4) Accessories (order separately) SCA-48=Stem Set Adjustable 48" length SCF-=Stem Set Fixed (specify length) SCS=Stem Set 45° Swivel (specify length)
and plug options only available with pendant mount option
(4) Stems
must be
Photometrics Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10 81 75 68 62 57 53 49 45 42 40 37
81 72 63 56 49 44 40 36 33 31 28
81 69 58 50 44 38 34 31 28 25 23
2HBHD-632-CL-UNV-EB82 (2) Electronic Ballasts (6) F32T8/TL835 lamps 3000 lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 1 2 x mounting height Efficiency 68 1% Test Report: 2HBHD632CL IES
81 66 55 46 39 34 30 27 24 21 19
76 67 59 52 47 42 38 35 32 29 27
76 65 56 48 42 37 33 30 27 25 23
Coefficients of Utilization 20% 30% 50 30 10
76 63 53 45 38 34 30 26 24 21 19
72 65 57 51 45 41 37 34 31 29 27
72 63 54 47 41 37 33 29 27 24 22
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
72 61 52 44 38 33 29 26 23 21 19
Lumens 3768 6124 10121 12258 12258
%Lamp 20 9 34 0 56 2 68 1 68 1
70 65 60 55 51 47 44 41 38 36 34
70 63 56 50 45 40 37 34 31 29 27
70 61 52 45 40 36 32 29 26 24 22
2HBHD-654T5-CL-UNV-EBT2 (3) Electronic Ballasts (6) F54T5HO/841 54W lamps 4400 lumens Spacing criterion: (II) 1 0 x mounting height, (⊥) 1 2 x mounting height Efficiency 52 9% Test Report: 2HBHD654T5CL IES
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
%Fixture 30 7 50 0 82 6 91 5 100 0
System Performance
70 59 49 42 36 32 28 26 23 21 19
66 59 53 47 42 39 35 32 30 28 26
20% 30% 50 30 10
66 66 57 56 50 47 44 41 39 36 35 31 31 28 28 25 26 23 24 21 22 19
63 57 51 46 41 37 34 32 29 27 25
63 55 48 43 38 34 31 28 26 23 22
63 54 46 40 35 31 28 25 23 21 19
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Lumens 5876 8802 13385 15627 15627
%Lamp 22 3 33 3 50 7 59 2 59 2
%Fixture 37 6 56 3 85 7 75 3 100 0
Dimensions
2HBHD
HBHD Lamp Configurations 4-lamp
Mounting Height
40'
4-1/2" [115mm] 5" 5" 5" [127mm] [127mm] [127mm]
30'
23-11/16" [602mm]
400W MH
400W MH
400W HPS
6-lamp
400W HPS
4-1/2" [115mm]
20' 250W MH
250W HPS
250W MH
250W HPS
X
X=3-1/2" [89mm]
X
X
X
X
23-11/16" [602mm]
10' Dimensions for Top View Energy Savings
50%
% Light Gain/Loss Part Number
51%
51%
21% -2%
52%
9% -13%
2HBHD-432-CLEB81/PLUS
2HBHD-632-CLEB81/PLUS
22%
24%
26%
4%
(4) 3/8" [10mm] Dia Mounting Hole
25%
(2) 7/8" [22mm] KO Gasketed Access Plate 12" [305mm]
15% -6%
2HBHD-454-CL-EBT1
T8
24%
23 11/16" [602mm]
10 3/16" [259mm]
2HBHD-654-CL-EBT2 1 1/2" [38mm]
36" [914mm]
T5
48" [1219mm]
% light gain/light loss utilize S/P adjusted lumens.
System Performance Table
Wattage
Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh
2HBHD-432-CL-EB81/PLUS
4
3100
94%
68%
1.15
9128
1.95
1.40
12747
147
$4.71
68
2HBHD-632-CL-EB82/PLUS
6
3100
94%
68%
1.15
13693
1.95
1.40
19121
221
$4.72
68
2HBHD-454T5-CL-EBT1
4
5000
93%
53%
1.00
9839
1.90
1.38
13563
229
$10.21
31
2HBHD-654T5-CL-EBT2
6
5000
93%
53%
1.00
14759
1.90
1.38
20344
346
$10.29
31
250W Metal Halide Encl & Gasketed High Bay
1
20800
58%
68%
1.00
8179
1.50
1.22
10018
295
$13.90
23
250W High Pressure Sodium Encl & Gasketed High Bay
1
30000
81%
68%
1.00
16475
0.62
0.79
12973
300
$10.91
29
400W Metal Halide Encl & Gasketed High Bay
1
36000
58%
68%
1.00
14157
1.50
1.22
17338
455
$12.39
26
400W High Pressure Sodium Encl & Gasketed High Bay
1
50000
81%
68%
1.00
27459
0.62
0.79
21621
464
$10.13
32
2HBHD System Comparison
No of Lamps
Design S/P Lamp Lumen Fixture Ballast System S/P Brightness Adjusted Lumens Maintenance1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4
LER5
Comparison System
FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 5000K lamps 5 LER (Luminaire Efficiency Ratio) is an accepted method of comparing fixture performance
26
ARCTIC BAY - AB Series
H I G H - B AY I N D U S T R I A L L U M I N A I R E
Enclosed, full bodied 20 gauge housing utilizes captive fasteners to protect optical assembly and assure structural integrity of housing while retaining heat for optimal system performance. Thermally optimized Arctic Bay is suitable for environments down to -20°F (-29°C). Housing is “post” painted with a high performance polyester powder coat finish to protect against contaminants and oxidation.
Occupancy sensor: integral high humidity, low temperature sensor provides 1400 sq. ft. of coverage in mounting heights up to 40'. MS/OB option keeps two inner lamps illuminated full time using outer lamps for occupancy control. MS/AO Option relay rotates on/off cycle between 2 lamp and 4 lamp ballasts to minimize lamp degradation.
Sealed and gasketed door frame provides a thermal environment for optimal lamp operation. Optional clear or prismatic shielding available.
ARCTIC BAY 120%
The Arctic Bay provides over 90% of it’s rated light output in ambient environments down to -15°F (-26°C). Recommended for use in -20°F (-29°C) to 32°F (0°C) environments.
RELATIVE LIGHT OUTPUT
110%
Thermal Optimization
100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0
Ordering Information
-5°F (-20°C)
15°F (-9°C)
35°F (1°C)
55°F (12°C)
AMBIENT TEMPERATURE - DEGREE (F) Sample Number: 2AB-654T5-UNV-EBT2-MS/0B-U
Width Blank=15" 2=24" Series AB=Arctic Bay Mounting Arrangement Blank=Stand Alone R=Continuous Row Mount No of Lamps 4=4 Lamps (AB) 6=6 Lamps (2AB) Lamp Type 54T5=54W T5HO Lamps (48") Distribution Blank=Medium (Specular Aluminum) G=Wide (White Painted)
Shielding Blank=Prismatic Acrylic Lens w/Gasketed Door Frame CL=Clear Acrylic Lens w/Gasketed Door Frame (2)
Voltage UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage 120V=120 Volt 277V=277 Volt 347V=347 Volt 480V=480 Volt
Ballast Type EBTL =T5 Linear Electronic Program Rapid Start Total Harmonic Distortion < 10% Minimum Start Temp -20°F (-29°C) No of Ballast 1, 2 or 3 DIM=Dimming Options C3=3' White Cord Fixture Attached C6=6' White Cord Fixture Attached MS/OB=Aisle Modular Sensor Wired with Inner Two Lamps Constant On (3) MSO/OB=360° Modular Sensor Wired with Inner Two Lamps Constant On (3) MS/AO=Aisle Motion Sensor/Alternate Off (Alternate Ballast Relay) (3) (4) MSO/AO=360° Motion Sensor/Alternate Off (Alternate Ballast Relay) (3) (4) PC3-Voltage=3' Cord/Plug Fixture Attached(2) PC6-Voltage=6' Cord/Plug Fixture Attached(2) TCBP=Top Connector Box Plate
Options Lamps Installed L5835=T5 Lamp, 85CRI 3500K L5841=T5 Lamp, 85CRI 4100K L5850=T5 Lamp, 85CRI 5000K GL=Single Element Fuse GM=Double Element Fuse EL=Emergency installed (see table on pg 36) (2)
NOTES: (1)Requires use of voltage specific modular cord assembly See accessories
27
-15°F (-26°C)
(2)Voltage
must be specified when ordered with plugs, motion or emergency ballasts
(3)Specify
Packaging U=Unit Pack PAL=Palletized Out of Carton PALC=Job Pack In Carton Accessories (order separately) AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-Hooks RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop HB-SPS=Single Point Cable Kit (13" Drop Length) Gripple Y-=Y Mounting Toggle, #2 Cable (Specify 10' or 30') TCB=Top Connector Box SCA-48=Stem Set Adjustable 48" length SCF-=Stem Set Fixed (specify length) SCS=Stem Set 45° Swivel (specify length)
voltage of ballast
(4)Requires
(2) ballasts Not available in 480V
Mounting Accessories
TCB=Top Connector Box
FH-1=Fixture Hook 2-1/2" FL-1=Fixture Loop 2-1/2" RH-1=Retrofit Hanger (must be used with TCB) (must be used with TCB) (must be used with TCB)
HB-SPS=Single Point Cable Kit
HB-SPS=Two Point Suspension
SC-_-_=Stem Sets (fixed, Swivel or Adjustable SCF=Fixed SCA=Adjustable SCS=Swivel
AYC-Mounting chain set
Y=Mounting Toggle and 10' or 25' cable
Dimensions Dimensions for Top View
Arctic Bay Lamp Configurations AB 4-Lamp 4-3/4" [121mm]
Mounting for Top Connector Box
Access Plate Opening
2AB 6-Lamp
11/16" [18mm] K O 17/64" Diameter Hole
5-1/2" [140mm] X
X=2-7/8" [74mm]
X
X
X
X=3-1/2" [89mm]
15-7/16" [392mm]
X
X
X
X 24" [610mm]
24" [610mm]
System Performance
AB Mounting Height
2-1/4" [58mm] 3-1/2" [89mm]
40' 48" [1219mm]
30'
Photometrics 400W MH
400W HPS
Coefficients of Utilization
20' 400W MH
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
400W HPS
10' Energy Savings
50%
% Light Gain/Loss Part Number
51%
3% -21%
2AB-454T5-UNV-EBTL
24%
25%
35%
19%
2AB-654T5-UNV-EBTL
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10 78 71 66 60 56 51 48 45 42 39 37
78 69 61 54 48 44 40 36 33 31 29
78 66 57 49 43 38 34 31 28 26 24
2AB-654T5-UNV-EBT2-U Electronic Ballasts (6) F54W T5HO lamps 5000 lumens Spacing criterion: (II) 1 1 x mounting height, (⊥) 1 2 x mounting height Efficiency 65 1% Test Report: BAL13590 IES
T5
% light gain/light loss utilize S/P adjusted lumens.
78 64 53 45 39 34 30 27 24 22 20
72 64 57 51 46 42 38 35 32 30 28
72 63 54 47 42 37 33 30 27 25 23
20%
72 61 51 44 38 34 30 27 24 22 20
30% 50 30 10 69 62 55 49 44 40 37 34 31 29 27
69 60 52 46 41 36 33 30 27 25 23
69 59 50 43 38 33 30 27 24 22 20
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Lumens 6856 10426 16414 19532 19532
%Lamp 22 9 34 8 54 7 65 1 65 1
%Fixture 35 1 53 4 84 0 100 0 100 0
System Performance Table
Wattage
Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh
AB-454T5-UNV-EBTL1
4
5000
93%
73%
1.00
13578
1.90
1.38
18716
229
$5.36
60
2AB-654T5-UNV-EBTL2
6
5000
93%
73%
1.00
20367
1.90
1.38
28074
346
$5.40
59
400W Metal Halide High Bay
1
36000
58%
71%
1.00
14825
1.50
1.22
18157
455
$11.29
28
400W High Pressure Sodium High Bay
1
50000
81%
71%
1.00
28755
0.62
0.79
22642
464
$9.24
35
Arctic Bay System Comparison
No of Lamps
Design S/P Lamp Lumen Fixture Ballast System S/P Brightness Adjusted Lumens Maintenance1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4
LER5
Comparison System
FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 5000K lamps 5 LER (Luminaire Efficiency Ratio) is an accepted method of comparing fixture performance
28
VT2/VT3
VA P O R T I T E I N D U S T R I A L
No holes required for surface/chain mounting from supplied mounting bracket. Fiberglass housing is reinforced polyester and self-extinguishing (ASTM-D635-74) plastic of a permanent pearl gray color.
Polyurethane gasketing is formed in the housing providing a continuous seamless seal for the diffuser.
High impact lens options to withstand the most demanding environments UL Listed for wet locations (standard).UL/cUL Listed. A watertite hub for 1/2" conduit entry is provided at each end of housing (standard) for continuous feed. Sturdy cam latches clamp diffuser tightly for a positive seal between housing, gasketing and diffuser.
Unit has full metal liner (channel) secured by brass internal/external mounting studs for positive grounding, maximum protection and rigidity.
Optional die formed or 95% Specular Miro finished reflector.
Ordering Information
New Architectural Form VT3 VT3’s EN-SEAL gasketing offers IP65 resistance to water absorption. TM
Sample Number: 8TVT2-254DR-UNV-EB82-M4-U
Width Blank=4' Length 8T=8' Length
Voltage (1) 120V=120 Volt 277V=277 Volt 347V=347 Volt 480V=480 Volt UNV=Universal Voltage 120/277V UNC=Universal Voltage 347/480V
Series VT2=Vaportite VT3=Vaportite (Gasketed Enclosure) Number of Lamps (3) 1=1 lamp (T5 or T8) 2=2 lamps (T5 or T8) 3=3 lamps (T8 only)
Options GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (3) (4) (see table on pg 36)
(Lamps not included)
Lamp Type 28=28W T5 Lamp (4' Long) 32=32W T8 Lamp (4' Long) 54T5=54W T5HO Lamp (4' Long)
Lens DR=Internal Prismatic Lens/15% DR High Impact Additive (Standard) DR-50=50% High Impact Additive DR-100%=100% High Impact Additive (Extreme) LEX=High Impact Clear Polycarbonate LEXAN Lens/Low Brightness Pattern
WL=Wet Location Ballast Type (1) Label T8 Systems EB8 =T8 Electronic Instant Start (4) Total Harmonic Distortion < 10% No of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start (4) High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start (4) Total Harmonic Distortion < 10% No of Ballast 1 or 2 ER8 /PLUS= T8 Electronic Program Start (4) High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 1 or 2 EB8 /L= T8 Electronic Instant Start Low Ballast Factor > 0 80 No of Total Harmonic Distortion < 40% Ballast 1 or 2 T5 Systems EBT =T5 Electronic Program Start
(1) Ballast
(2) Not
NOTES: type used only if ballast & voltage is chosen available when specifying emergency ballasts, voltage must be specific (3) T5HO is only available in 1 or 2-lamp versions only (4) Emergency option in 3 lamp version must use remote mount test switch (5) Top Hub required when stem mounting (6) VT2 only
29
No of Ballast 1 or 2 EHT =T5HO Linear Electronic Program Rapid Start High Ambient Total Harmonic Distortion < 10% No of Ballast 1 or 2
Packaging Options U=Unit Pack RIF1=Radio Interference Suppressor PALC=Job Pack (5) in Carton TH=(2) Top Watertite Hubs TEH=(2) Top & (2) End Watertite Hubs (all Watertite Hubs have 1/2" Conduit Entry) (5) DD=Deep Diffuser (4' Length) (6) (Available for 4' Fixture Length) To Complement 5-7/8" Deep Diffuser Depth of [150mm] 8' Fixture M4=Specular Reflector SSL=Stainless Steel Latches Accessories (order separately) VT2-Chain/Set-U=Chain Hanging Set Includes 6 ft of chain, 4 large S-Hooks and 4 small S-Hooks Order Two (2) Kits for each 4' or 8' Fixture VT2-SS-MBK=Stainless Steel Mounting Bracket VT2 Stem Bushing=1/2" 3/8" (Required when using Stem Sets Requires (1) per Stem Set )
Photometrics Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
⊥
||
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10 87 78 70 64 58 53 49 45 42 39 37
87 73 63 55 48 43 39 35 32 29 27
87 70 57 48 41 36 32 28 25 23 21
VT2-254DR-UNV-EB81-WL-M4-U Electronic Ballast (2) F54/T5/835 Lamps 4460 Lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 1 6 x mounting height Efficiency 74 3% Test Report: 127P111
87 66 52 43 36 31 27 23 21 18 17
80 67 58 51 45 40 36 32 30 27 25
80 64 53 45 39 34 30 27 24 22 20
Coefficients of Utilization 20% 30% 50 30 10
80 62 50 41 34 30 26 23 20 18 16
76 64 55 48 42 38 34 31 28 26 24
76 61 51 43 38 33 29 26 23 21 19
⊥
76 59 48 40 34 29 25 22 20 18 16
||
Lumens 1411 2397 4380 6268 6614
%Lamp 15 8 26 9 49 1 70 3 74 2
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10 96 86 77 70 64 58 54 50 46 43 40
96 81 69 60 53 47 42 38 35 32 29
96 77 63 53 45 39 35 31 28 25 23
VT2-232DR-UNV-EB81-WL-M4-U Electronic Ballast (2) T8 Lamps 2850 Lumens Spacing criterion: (II) 1 3 x mounting height, (⊥) 1 6 x mounting height Efficiency 81 7% Test Report: 127P113
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
%Fixture 21 3 36 2 66 2 94 8 100 0
96 73 58 47 40 34 29 26 23 20 18
87 74 63 55 49 44 39 35 32 30 27
87 70 58 49 43 37 33 29 26 24 22
20%
87 68 54 45 38 32 28 25 22 20 18
30% 50 30 10 82 69 60 52 46 41 37 34 31 28 26
82 67 56 47 41 36 32 28 25 23 21
82 64 52 43 37 31 27 24 21 19 17
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Lumens 985 1675 2999 4316 4658
%Lamp 17 3 29 4 52 6 75 7 81 7
%Fixture 21 1 36 0 64 4 92 7 100 0
Dimensions Z
5" [127mm] X
Y
6-5/8" [168mm] 7" [178mm]
Z
5" [127mm] X
W=2-5/8" [67mm] X=2-1/8" [54mm]
Dimensions for Top View
3-lamp (T8 only)
2-lamp
1-lamp
Y
Z
5" [127mm] X
Y
4'
41-1/2" [1054mm] Optional Back Hub Locations 38-3/4" [984mm] 1/4" x 28" Stud (2 Places)
W 6-5/8" [168mm] 7" [178mm]
W 6-5/8" [168mm] 7" [178mm]
6-5/8" [168mm] X=5-3/8" [137mm]
Y=3-3/16" [81mm] Z=1-1/2" [38mm]
8'
Y
X
Y=5-3/8" [102mm]
49-13/16" [1265mm]
89-1/2" [2273mm] Optional Back Hub Locations 87-1/16" [2211mm] 1/4" x 28" Stud (4 Places)
6-5/8" [168mm] X=5-3/8" [137mm] Y=5-3/8" [102mm]
40-13/16" [1037mm]
X
5-1/8" [130mm] 97-13/16" [2484mm]
40-13/16" [1037mm]
Y
System Performance
VT2 Lamp Type
175 MH
150W HPS
175 MH
150W HPS
175 MH
150W HPS
Energy Savings
45%
38%
66%
61%
49%
43%
% Light Gain/Loss
30%
39%
12%
24%
42%
50%
Part Number
VT2-254T5DR-M4
VT2-232DR-EB8/PLUS-M4 VT2-332DR-EB8/PLUS-M4
T5
T8
T8
% light gain/light loss utilize S/P adjusted lumens.
System Performance Table
Wattage
Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh
VT2-254T5DR-M4
2
5000
93%
74%
1.00
6910
1.90
1.50
6910
117
$5.29
VT2-232DR-EB8/PLUS-M4
2
3100
94%
82%
1.15
5476
1.95
1.40
7646
73
$3.25
98
VT2-332DR-EB8/PLUS-M4
3
3100
94%
82%
1.15
8214
1.95
1.40
11470
108
$7.43
43
175W Metal Halide Garage Light
1
13600
58%
70%
1.00
5474
1.50
1.22
6705
213
$14.65
22
150W High Pressure Sodium Garage Light
1
12900
81%
70%
1.00
7335
0.62
0.79
5776
188
$14.84
22
Vaportite Comparison (Specular Reflector)
No of Lamps
Design S/P Lamp Lumen Fixture Ballast System S/P Brightness Adjusted Lumens Maintenance1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4
LER5
60
Comparison System
FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 5000K lamps 5 LER (Luminaire Efficiency Ratio) is an accepted method of comparing fixture performance
30
ECOFIT – STRIPS
ENERGY EFFICIENT CONVERSION KITS
Description Ecofit conversion kits are an economical means of increasing fixture efficiency and energy savings. Ecofit conversion kits are ideal for applications where fixture removal is cost-prohibitive. Ecofit conversion kits are designed for applications with conventional 1 or 2-lamp strip/channel fixtures, such as task, coves, display cases, utility, and general area lighting.
Construction Socket tracks are die formed 20 gauge cold rolled steel. Toolless ballast access for easy wiring access and installation
Optical Modules
Electrical
Mounting
Die formed reflectors faceted for 1 and 2 lamp configurations with two optical distributions medium and wide. Medium beam optical modules utilize 95% specular Miro 4 substrate while the wide distribution utilizes a high performance 91% reflective polyester powder coated finish.
Optional electronic ballasts are Class “P” and are positively secured by mounting bolts. Twist-lock lampholders. UL/cUL listed. Suitable for damp locations.
Retrofit installation in standard 4' and 8' strip lengths and fits channels 4" to 5-5/8" wide. Hardware included. Kits are bulk packed for easier handling.
Ordering Information
Width Blank=4' 8=8' Series ECS=Ecofit Strip No of Lamps 1=1 Lamp 2=2 Lamps Lamp Type 32=32W T8 Lamp (48") 54=54W T5HO Lamp (48")
Sample Number: ECS-232-M-UNV-EB81-10B
Optics M=Medium (Specular Aluminum) W=Wide (White Painted)
Voltage NB=No Ballast UNV=Universal Voltage Ballast Included
Ballast/Socket Type T8 Systems EB8 =T8 Electronic Instant Start (1) Total Harmonic Distortion < 10% No of Ballast 1, 2 or Blank EB8 /PLUS=T8 Electronic Instant Start (1) High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 1 or 2 EB8 /L=T8 Electronic Instant Start w/ < 0 80 (1) Ballast Factor Total Harmonic No of Distortion < 10% Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start (1) Total Harmonic Distortion < 10% No of Ballast 1, 2 or Blank ER8 /PLUS= T8 Electronic Program Rapid Start High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 1 or 2 T5 Systems EBT =T5HO Electronic Program Start Total Harmonic Distortion < 10% No of Ballast 1 or 2
NOTES: (1)When using Ecofit Kits without ballasts, indicate ballast type and system to designate shunted or unshunted sockets Ex: ECS-232-M-NB-EB8-10B
31
Packaging 10B=10 Pack Quantities 80B=80 Pack Quantities U=Unit Pack
Photometrics Coefficients of Utilization Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
109 97 87 79 72 66 60 56 52 49 45
109 92 79 68 60 53 47 43 39 36 33
109 109 87 83 71 65 60 53 51 44 44 37 38 32 34 28 31 25 28 22 25 20
ECS-132-M-EB81 Electronic Ballast (1) 32W T8 2900 lumens Spacing criterion: (II) 1 3 x mounting height, (⊥) 1 5 x mounting height Efficiency 91 7% Test Report: ECS132MEB81
102 86 73 64 56 50 45 40 37 34 31
102 82 68 57 49 42 37 33 30 27 24
Coefficients of Utilization 20%
102 79 63 51 43 36 32 28 25 22 20
30% 50 30 10 97 82 70 61 54 48 43 39 36 33 30
97 79 65 55 47 41 36 32 29 26 24
97 76 61 50 42 36 31 27 24 22 20
Lumens 571 952 1809 2645 2661
%Lamp 19 7 32 8 62 4 91 2 91 7
106 96 86 78 71 65 60 55 52 48 45
106 91 78 68 59 53 47 43 39 36 33
106 106 86 82 71 65 60 53 51 44 44 38 39 33 35 29 31 25 28 23 25 21
ECS-232-M-EB81 Electronic Ballast (2) 32W T8 2900 lumens Spacing criterion: (II) 1 3 x mounting height, (⊥) 1 4 x mounting height Efficiency 89 4% Test Report: ECS232MEB81
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
%Fixture 21 5 35 8 68 0 99 4 100 0
99 85 73 63 56 50 45 41 37 34 31
99 81 67 57 49 43 38 33 30 27 25
20%
99 78 63 52 43 37 32 28 25 23 20
30% 50 30 10 95 81 70 61 54 48 43 39 36 33 30
95 78 65 55 48 42 37 33 30 27 25
95 76 61 51 43 37 32 28 25 22 20
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Lumens 1194 1983 3682 5161 5185
%Lamp 20 6 34 2 63 5 89 0 89 4
%Fixture 23 0 38 2 71 0 99 5 100 0
Installation 1-Lamp
2-Lamp
All components (reflectors, socket brackets, sockets, screws, and wire nuts) are included in each kit for installation and require only a few basic tools for assembly.
Reflector Dimensions
System Performance
Strip ECOFIT
5-1/8" [131mm] 2" [51mm]
2 LAMP T12 2 LAMP T12 SL
51%
42%
% Light Gain/Loss
9%
1%
Part Number
X=2-1/2" [64mm]
X
Energy Savings
10-5/8" [270mm]
ECS-132- 8ECS-132M-EB81 MEB81/PLUS
% light gain/light loss utilize S/P adjusted lumens.
System Performance Table
Wattage
Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh
ECS-132-M-EB81
1
3100
94%
89%
1.15
2993
1.95
1.40
4179
46
$3.43
93
8ECS-132-M-EB81/PLUS
2
3100
94%
89%
1.15
5985
1.95
1.40
8358
73
$2.72
118
Industrial & Channel (Strip) Ecofit Comparison
No of Lamps
Design S/P Lamp Lumen Fixture Ballast System S/P Brightness Adjusted Lumens Maintenance1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4
LER5
Comparison System 2L T12 Strip
2
2750
88%
71%
0.90
3093
1.50
1.22
3788
94
$12.43
26
2L T12 SL Strip
2
5330
93%
79%
0.88
6883
1.50
1.22
8430
126
$6.89
46
FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 5000K lamps 5 LER (Luminaire Efficiency Ratio) is an accepted method of comparing fixture performance
32
ECOFIT – TROFFERS
ENERGY EFFICIENT CONVERSION KITS
Description Ecofit conversion kits are an economical means of increasing fixture efficiency and energy savings. Ecofit conversion kits are ideal for applications where fixture removal is cost-prohibitive. Ecofit conversion kits are designed for applications with conventional 3 or 4-lamp recessed 2' x 4' fixtures. Retrofitting 3 and 4-lamp troffers to 2-lamps with high performance retrofit conversion kits can reap up to 50% energy savings.
Construction Socket tracks are die formed 20 gauge cold rolled steel. Toolless ballast access for easy wiring access and installation.
Optical Modules
Electrical
Mounting
Die formed reflectors are faceted for 2 lamp configuration with two optical distributions medium and wide. Medium beam optical modules utilize 95% specular Miro 4 substrate while the wide distribution utilizes a high performance 91% reflective polyester powder coated finish.
Optional electronic ballasts are Class “P” and are positively secured by mounting bolts. Twist-lock lampholders.(1) UL/cUL listed. Suitable for damp locations.
Retrofit installation in standard 2' x 2' and 2' x 4' recessed troffers. Hardware included.
Ordering Information
Width 2=24" Wide (only) Series ECT=Ecofit Troffer No of Lamps 2=2 Lamps 3=3 Lamps Lamp Type 17=17W T8 Lamp (24") 32=32W T8 Lamp (48") 24=24W T5HO Lamp (24") 54=54W T5HO Lamp (48")
Sample Number: 2ECT-217-M-UNV-EB81-10B
Optics M=Medium (Specular Aluminum) W=Wide (White Painted)
Voltage NB=No Ballast UNV=Universal Voltage Ballast Included
Ballast/Socket Type T8 Systems EB8 =T8 Electronic Instant Start (1) Total Harmonic Distortion < 10% No of Ballast 1, 2 or Blank EB8 /PLUS= T8 Electronic Instant Start (1) High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start (1) Total Harmonic Distortion < 10% No of Ballast 1, 2 or Blank ER8 /PLUS= T8 Electronic Program Rapid Start (1) High Ballast Factor >1 15 No of Total Harmonic Distortion < 10% Ballast 1 or 2 EB8 /L=T8 Electronic Instant Start w/ < 0 80 (1) Ballast Factor Total Harmonic No of Distortion < 10% Ballast 1 or 2 T5 Systems EBT =T5HO Electronic Program Start Total Harmonic Distortion < 10% No of Ballast 1, 2 or Blank
NOTES: (1) When using Ecofit Kits without ballasts, indicate ballast type and system to designate shunted or unshunted sockets Ex: 2ECT-232-M-NB-EB8-10B
33
Packaging 10B=10 Pack Quantities 80B=80 Pack Quantities U=Unit Pack
Photometrics Coefficients of Utilization Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
105 95 86 78 72 66 61 56 52 49 46
105 91 79 69 61 54 48 44 40 37 34
105 105 87 84 73 67 61 55 53 47 46 40 40 35 36 30 32 27 29 24 27 22
ECT-332-W-EB81 Electronic Ballast (3) FO32/841 lamps 2850 lumens Spacing criterion: (II) 1 3 x mounting height, (⊥) 1 4 x mounting height Efficiency 88 1% Test Report: ECT332WEB81
98 85 74 65 57 51 46 42 38 35 32
98 82 69 59 51 44 39 35 31 29 26
Coefficients of Utilization 20% 30% 50 30 10
98 80 65 54 46 39 34 30 27 24 22
94 82 71 62 55 49 45 40 37 34 32
94 79 67 57 50 43 38 34 31 28 26
rc rw RCR 0 1 2 3 4 5 6 7 8 9 10
94 77 63 53 45 39 34 30 27 24 22
Lumens 1907 3152 5753 7534 7534
%Lamp 22 3 36 9 67 3 88 1 88 1
105 97 89 82 76 70 65 61 57 53 50
105 93 82 74 66 60 54 50 46 42 39
105 105 89 86 77 73 67 62 59 54 52 47 47 42 42 37 39 34 35 31 32 28
ECT-232-M-EB81 Electronic Ballast (2) 32W T8 F32T8/TL841 lamps 3050 lumens Spacing criterion: (II) 1 2 x mounting height, (⊥) 1 1 x mounting height Efficiency 88% Test Report: ECT232MEB81
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Effective floor cavity reflectance 80% 50% 70 50 30 10 50 30 10
%Fixture 25 3 41 8 76 4 100 0 100 0
98 87 78 70 63 57 52 48 55 41 38
98 85 74 65 57 51 46 41 45 35 32
20%
98 82 70 60 53 46 41 37 38 30 28
30% 50 30 10 94 84 75 67 61 55 51 46 34 40 37
94 82 71 63 56 50 45 41 37 34 32
94 80 68 59 52 46 41 37 33 30 28
Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180
Lumens 1896 2988 4632 5366 5366
%Lamp 31 1 49 0 75 9 88 0 88 0
%Fixture 35 3 55 7 86 3 100 0 100 0
Installation All components (reflectors, socket brackets, sockets, screws, and wire nuts) are included in each kit for installation and require only a few basic tools for assembly.
Reflector Dimensions
System Performance
Troffer ECOFIT 3 LAMP T12 4 LAMP T12
X
3 LAMP T12 4 LAMP T12
9-3/4" [248mm]
3 LAMP T12 4 LAMP T12 3 LAMP T12 4 LAMP T12
19-13/16" [505mm]
Energy Savings
44%
54%
44%
% Light Gain/Loss
37%
3%
34% -1%
Part Number
X=1-7/8" [48mm]
54%
ECT-232-M-EB81/PLUS ECT-232-W-EB81/PLUS
55%
64%
55%
64%
17% -27%
14% -32%
ECT-232-M-EB82
ECT-232-W-EB82
% light gain/light loss utilize S/P adjusted lumens.
System Performance Table
Wattage
Cost of 1000 S/P Adj Lmns 4000 hrs $0.08 kWh
ECT-232-M-EB8/PLUS
2
3100
94%
88%
1.15
5898
1.95
1.68
8236
73
$2.80
114
ECT-232-W-EB8/PLUS
2
3100
94%
85%
1.15
5683
1.95
1.68
7937
73
$3.02
106
ECT-232-M-EB81
2
3100
94%
88%
0.88
4513
1.95
1.68
6302
58
$3.80
84
ECT-232-W-EB81
2
3100
94%
85%
0.88
4349
1.95
1.68
6073
58
$4.10
78
3L T12 Parabolic
3
2750
88%
65%
0.90
4247
1.50
1.22
5202
130
$13.67
23
4L T12 Troffer
4
2750
88%
75%
0.90
6534
1.50
1.22
8002
160
$9.48
34
Troffer Ecofit Comparison
No of Lamps
Design S/P Lamp Lumen Fixture Ballast System S/P Brightness Adjusted Lumens Maintenance1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4
LER5
Comparison System
FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 4100K lamps 5 LER (Luminaire Efficiency Ratio) is an accepted method of comparing fixture performance
34
OPTIONS & ACCESSORIES Lamp Options Brand
Lamp
HB/2HB
I8
MB (1)
3HBO/3HBOT
HBG
HBHD
VT2 (1)
VT3 (1)
Generic
L8730
X
X
X
X
X
X
X
X
L8735
X
X
X
X
X
X
X
X
L8741
X
X
X
X
X
X
X
X
I5
AB
LB30 LB35 LB41
GE
L5830
X
X
X
X
X
X
X
X
X
L5835
X
X
X
X
X
X
X
X
X
L5841
X
X
X
X
X
X
X
X
X
LGSP30M/OC8 (GE)
X
X
X
X
X
X
X
X
LGSP35M/OC8 (GE)
X
X
X
X
X
X
X
X
LGSP41M/OC8 (GE)
X
X
X
X
X
X
X
X
LGSPX30M/OC8 (GE)
X
X
X
X
X
X
X
X
LGSPX35M/OC8 (GE)
X
X
X
X
X
X
X
X
LGSPX41M/OC8 (GE)
X
X
X
X
X
X
X
X
LGF24T5M/830 (GE) LGF24T5M/835 (GE) LGF24T5M/841 (GE)
Philips
LGF28T5M/830 (GE)
X
X
X
X
X
X
LGF28T5M/835 (GE)
X
X
X
X
X
X
LGF28T5M/841 (GE)
X
X
X
X
X
X
LGF54T5M/830 (GE)
X
X
X
X
X
X
X
X
X
LGF54T5M/835 (GE)
X
X
X
X
X
X
X
X
X
LGF54T5M/841 (GE)
X
X
X
X
X
X
X
X
X
LWF17T8M/TL730 (Philips) LWF17T8M/TL735 (Philips) LWF17T8M/TL741 (Philips) LWF32T8M/TL730 (Philips)
X
X
X
X
X
X
LWF32T8M/TL735 (Philips)
X
X
X
X
X
X
LWF32T8M/TL741 (Philips)
X
X
X
X
X
X
LWF17T8M/TL830 (Philips) LWF17T8M/TL835 (Philips) LWF17T8M/TL841 (Philips) LWF32T8M/TL830 (Philips)
X
X
X
X
X
X
X
LWF32T8M/TL835 (Philips)
X
X
X
X
X
X
X
LWF32T8M/TL841 (Philips)
X
X
X
X
X
X
X
LWF24T5M/830 (Philips) LWF24T5M/835 (Philips) LWF24T5M/841 (Philips)
Sylvania
LWF28T5M/830 (Philips)
X
X
X
X
X
X
LWF28T5M/835 (Philips)
X
X
X
X
X
X
LWF28T5M/841 (Philips)
X
X
X
X
X
X
LWF54T5M/830 (Philips)
X
X
X
X
X
X
X
X
X
LWF54T5M/835 (Philips)
X
X
X
X
X
X
X
X
X
LWF54T5M/841 (Philips)
X
X
X
X
X
X
X
X
X
LSFO17M/730K (OSI) LSFO17M/735K (OSI) LSFO17M/741K (OSI) LSFO17M/830K (OSI) LSFO17M/835K (OSI) LSFO17M/841K (OSI) LSFO32M/730K (OSI)
X
X
X
X
X
X
X
X
LSFO32M/735K (OSI)
X
X
X
X
X
X
X
X
LSFO32M/741K (OSI)
X
X
X
X
X
X
X
X
LSFO32M/830K (OSI)
X
X
X
X
X
X
X
X
LSFO32M/835K (OSI)
X
X
X
X
X
X
X
X
LSFO32M/841K (OSI)
X
X
X
X
X
X
X
X
LSF24T5M/830 (OSI) LSF24T5M/835 (OSI) LSF24T5M/841 (OSI)
35
NOTES:
LSF28T5M/830 (OSI)
X
X
X
X
X
X
LSF28T5M/835 (OSI)
X
X
X
X
X
X
LSF28T5M/841 (OSI)
X
X
X
X
X
X
LSF54T5M/830 (OSI)
X
X
X
X
X
X
X
X
X
LSF54T5M/835 (OSI)
X
X
X
X
X
X
X
X
X
LSF54T5M/841 (OSI)
X
X
X
X
X
X
X
X
X
(1) Lamps
supplied, not installed
Emergency Options Nomenclature
Description
HB/2HB
I5
I8
MB
3HBO/3HBOT
HBG
HBHD
VT2
VT3
Generic
EL4 (350-450 Im) EL8 (600-700 Im)
X X
X X
X X
X X
X X
X X
X X
X X
X X
Sure-Lites
EL-FBP140X (350-450 Im) EL-FBP240U (600-700 Im) EL-FBP240M (600-700 Im) EL-FBP240H (1100-1400 Im)
X X X X
X X X X
X X X X
X X X X
X X X X
X X X X
X X X X
X X X X
Bodine
EL-B100 (350-450 Im) EL-B90 (500-600 Im) EL-B70A (600-700 Im) EL-B60 (600-700 Im) EL-B60U (600-700 Im) EL-B50 (1100-1400 Im) (1) EL-B50U (1100-1400 Im) (1) EL-B50ST (1100-1400 Im) (1) EL-B50RCT (1100-1400 Im) (1) EL-I32 (up to 550 Im) EL-I40 (up to 700 Im) EL-I48 (up to 700 Im) EL-I320 (1300 Im) (1) EL-I880 (2000 Im) (1) EL-I232 (2 @ 1400 Im) EL-ISD80 (1300 Im) (1) (2) EL-I40DL (up to 700 Im) (2) EL-I48DL (up to 700 Im) (2) EL-I80DL (1300 Im) (2) EL-I232DL (2 @ 1400 Im) (2)
X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X
Iota
X
X X X X X X X X
NOTES: (1) For battery wired to two lamps, specify “/2L” after battery description
(2) Approved
AB
for wet location listing
F-Bay Mounting Accessories Fixture Series
Gripple Single Toggle
Gripple “Y” Toggle
AYC
TCB/ STEM
TCB/ RH-1
TCB/ FH-1
TCB/ FL-1
HB-SPS
HB
X
X
X
X
X
X
X
2HB
X
X
X
X
X
X
X
3HBO/3HBOT
X
X
X
X
X
X
I5
X
X
X
X
X
X
X
I8
X
X
X
X
X
X
X
AB
X
X
X
X
X
X
MB
X
Gripple Loop Hanger
X X X X X
X
Packaging Options HB/2HB
I5
I8
MB
3HBO/3HBOT
HBG
HBHD
AB
VT2
VT3
U
Unit Pack
X
X
X
X
X
X
X
X
X
X
PAL
Palletized out of carton on a 25" x 48" pallet, shrink wrapped
X
X
X
X(3)
X
X
X
PALC
Palletized in carton on a 25" x 48" pallet, shrink wrapped
X
X
X
X(3)
X
X
X
X
X
Nomenclature Description
NOTES:
(3) Pallet
size is 40" x 58"
36
Mounting MOUNTING ACCESSORIES
D E S I G N AT I O N
DESCRIPTION
Top Connector Box
TCB= Top Connector Box (Includes Plate) TCBP= Top Connector Box Plate (Mounted on fixture) HB-TCB-KIT-U= Complete TCB Kit (Supplied Separately) HB-TCB-KIT-NO-PLATE-U= Kit for Fixture w/TCBP Installed
Suitable for conduit mounting or for use with fixture hook, loop or safety hook. Use chain or cable set to meet NEC requirements for single point mounting, as well as to prevent cantilevering and rotation of fixture from one central location. Ideal for Retrofit opportunities!
FRONT
SIDE
TOP
2-5/16" [59mm]
3-9/16" [91mm]
4-11/16" [120mm]
X 4-11/16" [120mm]
X=2-11/32" [60mm]
MOUNTING METHODS
D E S I G N AT I O N
DESCRIPTION
Hook and Safety Hook
FH–1= Fixture Hook
Fixture Hook 2-1/2" (must be used with TCB)
TOP 3-3/8" [86mm] 1-1/2" HEX. [39mm]
1-7/8" [48mm]
1-3/16" [31mm]
MOUNTING METHODS
1" [26mm]
D E S I G N AT I O N
DESCRIPTION
FL–1= Fixture Loop
Fixture Loop 2-1/2" (must be used with TCB)
MOUNTING METHODS
D E S I G N AT I O N
DESCRIPTION
Retrofit Hanger
RH–1= Retrofit Hanger
Cast Aluminum Hanger w/Toggle Nut & Carriage Bolt for quick installation (must be used with TCB)
MOUNTING METHODS
D E S I G N AT I O N
DESCRIPTION
Loop
Stem
Accessories (order separately) = Stem Set (Order Two Per Fixture) SC Length: 6", 8", 12", 24", 36", 48", 60", 72") F=Fixed S=45° Swivel A=Adjustable (48" Only)
37
Fixed, swivel or adjustable stem sets are available in various lengths.
Mounting MOUNTING METHODS
D E S I G N AT I O N
DESCRIPTION
AYC Chain Set
AYC–Chain/Set–U=Mounting chain set (3)
(2) sturdy Wire Hooks and 36" Chain Sets w/S-hooks
Note: Not for use in high abuse areas such as gymnasiums or similar recreational facilities.
MOUNTING METHODS
D E S I G N AT I O N
DESCRIPTION
“Y” Toggle
Gripple–Y–10=Mounting Toggle and 10' Cable
10', Y Toggle #2 Cable
Gripple–Y–-25=Mounting Toggle and 25' Cable
25', Y Toggle #2 Cable
MOUNTING METHODS
D E S I G N AT I O N
DESCRIPTION
Loop Hanger/Single Toggle
Gripple–Loop–10
10' Loop Hanger #2 Cable
Gripple–Loop–30
30' Loop Hanger #2 Cable
Gripple–Toggle–10
10' Single Toggle #2 Cable
Gripple–Toggle–30
30' Single Toggle #2 Cable
Loop Hanger
Single Toggle
MOUNTING METHODS
D E S I G N AT I O N
DESCRIPTION
SPS Cable Kit
HB–SPS (1) (2)
Single Point Cable Kit= Stainless Steel Cable Kit for single point suspension. (Fixture dropped below mounting point by 13")
SINGLE POINT
TWO POINT
Two Point Suspension= (Fixture dropped below mounting point by 29") Note: Not for use in high abuse areas such as gymnasiums or similar recreational facilities. NOTES:
(1) Only
one required per fixture
(2) Fixture
Hook not included
38
Occupancy Sensors O C C U PA N C Y S E N S O R S
D E S I G N AT I O N
DESCRIPTION
CPD-1200H
MS= Aisle Coverage Occupancy Sensor (120V-277V) (1)
CPD-1200 Aisle Coverage Occupancy Sensor (120V-277V) (Rectangular Beam, Pattern Coverage)
600' sq ft
40' Height
MMS-CPD1200H= Aisle Motion Sensor for Modular Power Supply Option (120V/277V) (1)
Supplied with Mounting Box and Modular Power Supply Receptacle. 600' sq. ft. For use with MP option
E AT
PL
D
EN
X
X=Height 4-5/8" [118mm]
Width 4-5/8" [118mm] Length 4-5/8" [118mm]
NOTES: (1) One motion sensor per fixture required
O C C U PA N C Y S E N S O R S
D E S I G N AT I O N
CPD-500H
MSO= 360° Coverage Occupancy Sensor (120V-277V)(1)
DESCRIPTION
CPD-500 360° Coverage Occupancy Sensor (120V-277V) (360° Circular Pattern Coverage)
Approximately 1250 sq ft @ 40 ft
MMS-CPD500H= 360° Motion Sensor for Modular Power Supply Option (120V/277V) (1)
NOTES: (1) One Motion Sensor per fixture required
39
Supplied with Mounting Box and Modular Power Supply Receptacle For use with MP option
Power Connections POWER CONNECTIONS
D E S I G N AT I O N
DESCRIPTION
PC3, PC6
PC3= 3' Power Cord & Plug (specify voltage for plug)
PC3 – 3' long Cord & Plug set w/NEMA L515 or L715 twist lock plug (white)
PC6= 6' Power Cord & Plug (specify voltage for plug)
PC6 – 6' long Cord & Plug set w/NEMA L515 or L715 twist lock plug (white)
MPC3=3' Modular Power Cord & Plug MPC6=6' Modular Power Cord & Plug
MPC3=3' long Modular Cord & Plug set w/NEMA L/515 or L715 twist lock plug white. Use with MP option. MPC6=6' long Modular Cord & Plug set w/NEMA L/515 or L715 twist lock plug white. Use with MP option.
POWER CONNECTIONS
D E S I G N AT I O N
DESCRIPTION
C3, C6
C3= 3' Cord
C3 – 3' long 3/16 STW white Power Cord
C6= 6' Cord
C6 – 6' long 3/16 STW white Power Cord
MC3=3' Cord
MC3 – 3' long 3/16" Standard Modular Power Cord. For use with MP option.
MC6=6' Cord
MC6 – 6' long 3/16" Standard Modular Power Cord. For use with MP option.
POWER CONNECTIONS
D E S I G N AT I O N
DESCRIPTION
MWS
MWS= Modular Wiring System
MWS is a simple and cost effective modular wiring system consisting of factory assembled components. MWS arrives at the job site ready to be snapped together into a complete branch circuit wiring system. With MWS, branch circuit wiring can be installed in minutes instead of hours. Reduces labor by 80% for lowest total installed cost. Fixtures and wiring are portable for future flexibility.
MDS6= 6' Modular Power Cord with MWS
27DS18/2G06MP Connect directly to F-Bay or Motion Sensor
P I O P T I O N O R D E R I N G I N F O R M AT I O N
Catalog Number Suffix
Number of Circuits
Circuit Wired To Ballast
PI 1 BLK PI 2 BLU PI 2 BLK
1 2 2
Black Blue Black
PI 3 RED PI 3 BLU PI 3 BLK
3 3 3
Red Blue Black
Catalog Numbering System The PI System is available in sections up to 8' in length for continuous row wiring by simply plugging the sections together. Each PI section is factory wired to the ballast leads. Color coding of wires is as follows: PI-1 = One Circuit - 2 Wires: one black, one white PI-2 = Two Circuits - 3 Wires: one black, one blue, one white PI-3 = Three Circuits - 4 wires: one black, one blue, one red, one white When ordering the PI2/PI3 System it is necessary to specify the number of fixtures required for each circuit. All wiring to external feeds, using cord or cord & plug, are responsibility of installing licensed contractor. Cord and cord & plug sets must be ordered separately if PI option is chosen.
PI1 - Single Circuit Plug-In
PI2 - Two Circuit Plug-In
PI3 - Three Circuit Plug-In
SAMPLE NUMBER: PI1BLK-WG
SAMPLE NUMBER: PI2BLK-WG
SAMPLE NUMBER: PI3BLK-WG
PI1= Single Circuit BLK=Black Hot
NG= No Ground (ground provided by fixture body) WG= With Ground (separate ground wire in harness)
For complete product data, reference the Fluorescent Specification binder Specifications & dimensions subject to change without notice Consult your Cooper Lighting Representative for availability and ordering information
PI2= Two Circuit
Leave Blank=Single Neutral 2NEU=Two Neutrals
BLK=Black Hot BLU=Blue Hot
NG= No Ground (ground provided by fixture body) WG= With Ground (separate ground wire in harness)
Leave Blank=Single Neutral /WHT=White Neutral /GRY=Gray Neutral
PI3= Three Circuit
Leave Blank=Single Neutral 2NEU=Two Neutrals
BLK=Black Hot BLU=Blue Hot RED=Red Hot
NG= No Ground (ground provided by fixture body) WG= With Ground (separate ground wire in harness)
Leave Blank=Single Neutral /WHT=White Neutral /GRY=Gray Neutral
40
I5/I8 Lens, Door Frames and Wireguards
41
I5/I8 LENS
D E S I G N AT I O N
DESCRIPTION
FROSTED ACRYLIC LENS
I5-FRM/LENS= Frosted Acrylic Lens & Frame (use with general distribution reflector, I5 only) I8-FRM/LENS= Frosted Acrylic Lens & Frame (use with general distribution reflector, I8 only) I5-FRM/CL PK= Clear Acrylic Lens & Frame (use with general distribution reflector, I5 only) I8-FRM/CL PK= Clear Acrylic Lens & Frame (use with general distribution reflector, I8 only)
In white door frame w/”Herringbone” patterned end rail
I5/I8 WIREGUARD
D E S I G N AT I O N
DESCRIPTION
HEAVY DUTY WIREGUARD
WG/I5-4FT-B= 4' Heavy Duty Wireguard (for I5) WG/I8-4FT-B= 4' Heavy Duty Wireguard (for I8)
Finished in white. Can be used alone or in combination with other shielding
I5/I8 BAFFLE
D E S I G N AT I O N
DESCRIPTION
TBW
90800PPK= 4' Thin Blade White Baffle (for I5) BAFFLE 4FT I8 (WHITE) 11571919= 4' Thin Blade White Blade Baffle (for I8)
Thin Blade White Baffle w/23° longitudinal shielding
I5/I8 LOUVER
D E S I G N AT I O N
DESCRIPTION
ASYMMETRIC LOUVER
90801PPK= Asymmetric Directional Louver (use with general distribution reflector)
Can be oriented in either direction for flexibility
HB/2HB Lens, Door Frames and Wireguards HB/2HB LENS & DOOR FRAME
D E S I G N AT I O N
DESCRIPTION
PRISMATIC & CLEAR ACRYLIC LENS & DOOR FRAME
HB-FRM/LENS PK= Prismatic Acrylic Lens & Door Frame for HB (use with general distribution reflector)
A wide choice of acrylic lenses in a steel door frame (G1 & G2 optional)
2HB-4-A W/FRM PK= Prismatic Acrylic Lens & Door Frame for 2HB (use with general distribution reflector) HB-FRM/CL PK= Clear Acrylic Lens & Door Frame for HB 2HB-FRM/CL PK= Clear Acrylic Lens & Door Frame for 2HB
HB/2HB LENS & WIREGUARD
D E S I G N AT I O N
WIREGUARD
HB-FRM/WG PK= Frame and Wireguard for HB 2HB-FRM/WG PK= Frame and Wireguard for 2HB HB-FRM/LENS/WG PK= Frame and Prismatic Acrylic Lens with Wireguard for HB 2HB-FRM/CL/WG PK= Frame and Clear Lens with Wireguard for 2HB
HB/2HB DROP WIREGUARD
D E S I G N AT I O N
DROP WIREGUARD
HB-FRM/DROPWG PK= Frame and Drop Wireguard for HB 2HB-FRM/CL/DROPWG PK= Drop Wireguard, Clear Acrylic Lens and Door Frame for 2HB 2HB-FRM/LENS/DROPWG PK= Drop Wireguard, Prismatic Acrylic Lens and Door Frame for 2HB 2HB-FRM/DROPWG PK= Drop Wireguard and Door Frame for 2HB
H B / 2 H B H E AV Y D U T Y W I R E G U A R D
D E S I G N AT I O N
DESCRIPTION
HEAVY DUTY STOCK WIREGUARD
SWG/2HB-4FT-B= Heavy Duty Wireguard for field installation, 2HB only SWG/HB-4FT-B= Heavy Duty Wireguard for field installation, HB only
Finished in white
42
Cooper Lighting Customer First Center 1121 Highway 74 South Peachtree City, GA 30269
International Sales, USA Cooper Lighting 1121 Highway 74 South Peachtree City, GA 30269
P: 770-486-4800 F: 770-486-4801
P: 770-486-4800 F: 770-486-4801
www.cooperlighting.com
Canada Cooper Lighting 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 P: 905-507-4000 F: 905-568-7049
Domestic Facilities Cranbury, New Jersey Elk Grove Village, Illinois Irving, Texas Ontario, California Peachtree City, Georgia
The Cooper Lighting Family Halo Metalux Lumark Sure-Lites Neo-Ray Corelite Portfolio Iris Shaper io Lumière Invue McGraw-Edison Streetworks Fail-Safe MWS DLS RSA Ametrix
Canadian Facility Calgary, Alberta T2E 7V9
Cooper Lighting, Metalux and Fail-Safe are valuable trademarks of Cooper Industries in the United States and other countries. You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries. Cooper Industries, Ltd. 600 Travis, Ste. 5800 Houston, TX 77002-1001 P: 713-209-8400 www.cooperindustries.com
ACF080768