Instructions Subject: FRP ADA Splash Panel Retrofit Installation

020003338 11/10

Instructions Subject: FRP ADA Splash Panel Retrofit Installation The ADA touch pads are configured to mimic the function of the main touch pads on the left and right sides of the splash panel for handicapped accessibility to drink flavors. TOOLS NEEDED •

#2 Phillips Screwdriver



Power Drill



#29 (.136") Bit, for 6-32 Self-tapping Screw



Tape Measure



Marker or Scribe

ADA Touch Pads

KIT CONTENTS •

Splash Panel with ADA Touchpad's



Four Ribbon Cables



Zip Ties



ADA Flavor ID Label Sheet



Instruction Sheet



Template to Relocate Holes

ADA Ribbon Cable Wiring Diagram

INSTRUCTIONS 1. Disconnect dispenser from electrical power source. 2. Remove Merchandiser and Splash Panel. 3. Relocate both left and right Splash Panel screw mount points as shown below. Attach Template Using the Top Hole From the Bracket Removed.

Locate Current Right or Left Side Splash Panel Bracket & Remove Using #2 Phillips Screwdriver.

Use the Template to Locate , Mark, & Drill 2 New Holes Using a #29 (.136") Bit

Remove Template & Re-attach bracket.

Repeat process for opposite side of the machine.

a

b

c

d

4. Replace all 4 primary valve touch pad ribbon cables, (1,3,4,6) with the new cables supplied. Note that the new cables are numbered the same as the existing cables, (EXAMPLE: New cable marked #1 will replace existing cable #1), see the ADA Ribbon Cable Wiring Diagram illustration in the upper right of this page.

Manitowoc Beverage Systems Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com

FRP ADA Splash Panel Retrofit Installation

020003338 11/10

Route Ribbon Cables

Connect New Ribbon Cables to Board

Connect Ribbon Cables to Splash Panel

NOTE: Use the zip ties provided to secure the ribbon cables. The center plug with 2 ribbon cables is plugged into the control board. The shorter of the two cables is plugged into the touch pad control above the valve. The longer ribbon cable is to be fed down behind the syrup beverage tubing, exiting out the lower front of the unit, to be connected to the ADA Touch pad in the Splash Panel, see above.

5. After connecting all four ribbon cables to their respective touch pads, place the splash panel back into position and test each pad for function, see below. Each ADA touch pads should activate the nozzle indicated below. If the wrong nozzle is activated check for a cross connection of the ribbon cable. Note that the blue LED light will illuminate, (not blink) at the touch pad control above the valve during activation. CORRESPONDING PAD

S1

S3

F1 F3

S5

S7

S12

S10

F5 F7

S16

S14

S2

S4

F2 F4

S6

S8

S11

S9

F6 F8

S15

S13

N2

N1

S1

S3

S2

S4

S5

S7

S6

S8

Connect New Ribbon Cables to Board

N3

ADA 1

ADA 2

N5

N4

ADA 3

ADA 4

N6

S16

S14

S15

S13

S12

S10

S11

S9

CORRESPONDING PAD

CORRESPONDING PAD

CORRESPONDING PAD

Connect Ribbon Cables to Splash Panel

6. Once correct operation has been confirmed, place flavor I.D. labels on ADA touch pad as shown in Photo 6 by aligning the outer edges of the label with the control pad frame, and press into place. Replace the unit Merchandiser, and then the ADA Splash Panel. As you replace the splash panel do not pinch the ribbon cables.

Manitowoc Foodservice Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com