Lithium Ion Battery - Discover AES

Report 1 Downloads 89 Views
42-48-6650 DATASHEET

Lithium Ion Battery

BENEFITS & FEATURES

Discover Advanced Energy (AES) batteries allow for equipment design and functionality improvements and deliver productivity gains through enhanced cycling, charge time and weight reductions in stationary and mobile applications. Dramatic improvements in cycle life and charge efficiency combined with zero maintenance requirements provide the end user with significant cost of ownership savings.

Efficient & Fast Charging Discover AES batteries are 15% more efficient than lead acid batteries, allowing for reduced charge times and greater utilization of renewable energy sources.

Charge Time (Hours)

MECHANICAL DRAWINGS

100%

A

Charge Returned

B

Discover AES Lead Acid

Hours

Efficient and Stable Discharge Deliver > 95% of their capacity at high and stable voltages, increasing equipment performance and reducing motor fatigue.

Discharge Voltage

Voltage

Terminal

8

Discover AES

20

Lead Acid

Depth of Discharge

C

10

1.60

A A

SECTION A-A Terminal units in mm

MECHANICAL SPECIFICATIONS 471.5 mm

18.5 in

Nominal Voltage

51.2 V

Width (B)

347.5 mm

13.7 in

Charge Voltage

54.4 V

Height (C)

375 mm

14.7 in

Maximum Voltage*

58.4 V

87 kg

192 lb

Minimum Voltage

44.8 V

Nominal Capacity (1C)

130 Ah

Nominal Energy (1C)

6656 Wh

Terminal Terminal Torque

M8 9 Nm +/- 3

6.64ft-lb

Case Material

Steel

IP Rating

IP 55

Max Continuous Current Peak Current

Renewable System Ready Xanbus commport provides plug and play integration with SE Conext XW+, SW, SCP, ComBox and Solar Charge Controllers.

130 A 600 A for 3 seconds

Electrical Specifications at 25°C. * Do not exceed 80V at the battery terminals.

ELECTRICAL SPECIFICATIONS Cell Chemistry

LiFePO4

Cell Modules

16S 26P

Charge Temperature

Weight Efficient Systems are 1/3 the weight of their lead acid battery equivalent. Battery Management System Integrated Battery Management System to prevent abuse outside of current, voltage and temperature limits.

ELECTRICAL SPECIFICATIONS

Length (A)

Weight

Partial State of Charge (SOC) Discover AES batteries will not suffer negative effects from partial SOC.

SAFETY AND PERFORMANCE CERTIFIED • IEC 62133 • UL 2271 (pending) • UL1973 (pending) • UN 38.3

SHIPPING CLASSIFICATION

Constant Power - Minutes of Discharge 500 W

1000 W

2000 W

3000 W

799

399

200

133

0°C / 45°C

32°F / 113°F

Discharge Temperature

-20°C / 50°C

-4°F / 122°F

Storage Temperature

-20°C / 45°C

-4°F / 113°F

@10A

@25A

@50A

@100A

Self-Discharge 25°C / 77°F

< 3% per month (battery off)

780

312

156

78

• UN 3480, Class 9 (Lithium ion batteries)

Constant Current - Minutes of Discharge

CAUTION: Extra considerations must be given to depths of discharge, operating voltages and currents when designing systems for use at maximum operating temperatures.

808-0004 REV E

#4 -13511 Crestwood Place, Richmond, BC, V6V 2E9, Canada

E: [email protected]

T: +1 (778) 776-3288

discoverbattery.com

Qualification is a hand shaking procedure that allows a charger to wake up an auto-on equiped AES battery. Qualification is an optional feature and not required for standard charging.

CAUTION :

Nominal Voltage

48 V

Qualification Voltage (VQ*) Qualification

Bulk

100%

57.6 I1

80%

54.4 U1

60%

51.2 I2

40% 20%

48

VBATT VQ

≥ 40 V 65 A recommended 130 A maximum

Bulk Current (I1) Absorption Voltage (U1)

54.4 V

Termination Charge Current

I2 ≤ 2 A

*Qualification is optional to utilize auto-on feature

44.8

IQ Voltage - U

Current - I

DISCHARGE VOLTAGE IN RELATION TO THE TEMPERATURE

VOLTAGE IN RELATION TO THE STATE OF CHARGE (SOC)

Testing Conditions: 1C Discharge, 1C Charge

Test Conditions: 25°C / 77°F, 0.5C Charge 57.6

56

54.4

54.4

51.2

52.8 51.2

48 0.3 C

44.8

Voltage

Voltage (VPCM)

Min 12 V / Max 48 V (IQ < 1 A)

Battery Voltage (VBATT)

Absorption

Battery Voltage [V]

Extra considerations must be given to depths of discharge, operating voltages and currents when designing systems for use at maximum operating temperatures.

VOLTAGE REGULATED IU CHARGING CURVE PARAMETERS

VOLTAGE REGULATED IU CHARGING CURVE

Charge Current % of Bulk Charge C-Rate [%]

NOTE 1 :

0.5 C

41.6

49.6 48

65°C / 149°F 45°C / 113°F 25°C / 77°F 0°C / 32°F -10°C / 14°F -20°C / -4°F

46.4

1C

38.4

44.8

35.2

43.2

32

41.6

100%

80%

60%

40%

20%

0%

0%

20%

State of Charge (SOC)

40%

60%

80%

100%

Capacity

THERMAL DERATING CURVE (CURRENT)

150 130A

Current (A)

125 100

80A

75 50 25

0

10

20

30

40

50

60

Temperature (°C)

CAUTION: Direct connection to DC motors without proper safety protection, motor controllers, and external motor voltage clamping systems (such as high power anti-parallel diodes or braking resistor systems) may result in damage to the internal pack protection system which may result in unsafe situations. Please consult Discover technical support before directly connecting any motor loads.

Discover Energy Corp. attempts to ensure the correctness of the product description and data contained herein. We reserve the right to change designs, specifications and pricing at any time without notice or obligation. It is the responsibility of the reader of this information to verify any and all information presented herein.

Updated: December 15th, 2016

#4 -13511 Crestwood Place, Richmond, BC, V6V 2E9, Canada

E: [email protected]

T: +1 (778) 776-3288

discoverbattery.com