M WALL MOUNT 1, 2-Lamp, T5, T5HO. 1-Lamp T8, Direct Symmetric PROJECT INFORMATION Project Name

Type

Catalog No.

Date

CONSTRUCTION Extruded aluminum housing includes typical recycled content of 25-30%. END CAPS

DI SC ON TIN UE D

Die cast flat end caps for standard lamp configuration. Both end caps feature silicone gasket to eliminate light leak, see Light Seal. Ships installed on fixture.

minimizes the visibility of fingerprints and construction dust without sacrifice to aesthetic qualities. M4R - 95% Reflective Specular Aluminum louver combine glare control and performance with a high tech, cubed aesthetic. HEP - High efficiency specular parabolic louvers maximize downlight for enhanced efficiency where maximum light output is the primary concern.

FEATURES • 3½" × 3½" rectilinear beam appears to float just off vertical surface of wall • ADA compliant • 1 or 2 T5 or T5HO, 1T8 • Extensive aesthetic options • Symmetric downlight distribution with a wide choice of shieldings • Full family including cable mount, wall mount, surface mount and recessed • Companion fixtures include the 2½" × 3½" Microlyne® Mini and 3½" × 5" Microlyne® DirectIndirect • Aesthetic continuity across family, shielding and options • Patented clips for louver retention (Patent #8,142,048)

LIGHT SEAL

Housing unions between all joints include upper formed light seal and aligner connectors to block light. End of row and single units feature unique optimized V-0 closed cell silicone gasket light seal at joints between extruded housing and die cast end cap.

DISTRIBUTION

CONNECTIONS

ELECTRICAL

Secure, simple housing connections ensure row continuity. Standard lamp configuration features patent pending Ready Connect system for end cap connections.

—All luminaires are built to UL1598 standards and bear the appropriate cUL or CSA labels. Damp location listed. —Quick connect plugs standard.

MOUNTING

FINISH

Microlyne® Wall Mount uses cleverly designed, ADA compliant, discreet wall brackets to create a floating appearance approximately 1/2” from the vertical wall surface. Brackets are made with heavy gauge galvanized steel. REFLECTOR

High reflectance formed white reflector.

SHAPE AND DIMENSIONS

Shielding is provided for single or continuous row. OA - Opal Acrylic lens emphasizes the narrow rectilinear shape by creating a pleasant glow of white along the underside of the housing. WCB – White Cross Baffle emphasizes linearity with a crisp, clean bladed appearance. MA - Matte anodized louvers incorporate an attractive but subtle grain pattern which

4"

ORDERING INFORMATION

4 8 12 __





ROW LENGTH 4' Single 8' Single 12' Single Indicate row length in 4' increments.1, 2

MODEL M Microlyne

ROW PATTERN Blank Straight P Pattern (specify) Pattern layouts require factory approval drawings.

Page 1/2 Rev. 12/19/16

CONTROLS COMPATIBILITY

Controls compatible. When used with occupancy sensors, most lamp vendors recommend program start ballasts (EP) to extend lamp life.

Name: Test #: Efficiency: LER:

M-1T5-HEP-EP 14885 85.5% 70

EXAMPLE: M-16-1DT5-WM-WCB-EP120-MW-EL



WM





LAMP TYPE AND PROFILE MOUNTING 1DT5 One T5 WM Wall Mount Lamp3 1DT5HO One T5HO Lamp3 1DT8 One T8 Lamp 2DT5 Two T5 Lamps 3 DOWNLIGHT SHIELDING 2DT5HO Two T5HO OA Opal Acrylic Lens Lamps 3 WCB White Cross Baffle

VOLTAGE U 120V277V 120 120V 277 277V 347 347V

COLOR MW Matte White (Std.) ZT ZET Metallic Silver See Color Selection Guide for other colors.

BALLAST E Electronic, Instant Start, (Std. for T8) EP Electronic, Programmed Start (Std. for T5 & T5HO, optional for T8) ED Electronic, Dimming (Must Specify)4 ESD Electronic, Step Dimming (Contact factory)4 Unless specified, Alera will use fewest ballasts possible.

MA Matte Anodized Low Iridescent Semi-Specular Aluminum Louver (24 Cell) M4R 95% Reflective Specular Aluminum Louver (24 Cell) HEP High Efficiency Parabolic Specular Louver (15 Cell)

Rows over 12' will be configured by Alera. Example: 16' will be (2) 8'. For alternate configurations, contact factory. 2 Shorter increments are available–contact factory. 3 Lamps may cause visible socket shadow in down light component. 1

Matte White powder coat standard for end caps and housing. Zet Silver and additional colors and finishes optional.

SHIELDING

3½"

M —

Symmetric downlight distribution is standard and used for general purpose lighting where uniform distribution is desired. Asymmetric downlight louver also available; see MA WM specification sheet.



OPTIONS LR Left/Right Switching (2-Lamp only) EL One Emergency Battery Pack Per Row4, 5, 7 EMC One Emergency Circuit4, 5, 6, 7 NLC Night Light Circuit4, 5, 6, 7 GLR Fast Blow Fuse GMF Slow Blow Fuse

Specify dedicated voltage. Not available with all configurations; some limitations apply. Contact factory for details. 6 One extra feed drop per EMC/NLC. For through wiring, contact factory. 7 For additional, specify quantity before nomenclature (Example: 2EL120, EMC277). 4 5

US and Canada Patents Pending. Specifications subject to change without notice.

© 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

BEAMS / M WM

M WALL MOUNT 1, 2-Lamp, T5, T5HO. 1-Lamp T8, Direct Symmetric CROSS SECTION

Opal Acrylic Lens

M4R

White Cross Baffle

HEP

Symmetric Louver

½"

Baffle

Lens

DI SC ON TIN UE D

3½"

2T5

1T8

Plaster Ring (Supplied By Others) 4" 3½" 1T5

PHOTOMETRIC DATA

LUMINAIRE DATA Test 14885 Luminaire

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle

ZONAL LUMEN SUMMARY Zone

M-1T5-HEP-EP Microlyne® Beams 3.5" × 48" 1-Lamp with 15 Cell Louver ICN-2S28 1.04 F28T5 2600 33 0º = 19  90º = 33

0-30 0-40 0-60 0-90 0-180

ENERGY DATA

Lumens % Lamp % Fixt. 850 1388 2145 2222 2222

32.7 53.4 82.5 85.5 85.5

Total Luminaire Efficiency Luminaire Efficacy Rating (LER) IESNA RP-1-2004 Compliance

38.3 62.5 96.5 100.0 100.0

Comparative Yearly Lighting Energy Cost per 1000 Lumens

INDOOR CANDELA PLOT

CANDELA SUMMARY

90

RCR

COEFFICIENTS OF UTILIZATION (%) 70 96 89 82 76 71 66 61 57 54 50

80 50 30 93 90 83 79 75 70 68 62 62 55 56 49 51 45 47 41 43 37 40 34

10 87 75 65 57 50 45 40 36 33 30

70 93 87 80 75 69 64 60 56 53 49

50 91 82 74 67 61 55 51 46 43 40

70

30 88 78 69 61 55 49 44 40 37 34

10 86 74 65 57 50 44 40 36 33 30

50 87 79 72 65 59 54 49 45 42 39

50 30 85 76 67 60 54 48 44 40 36 33

10 83 73 64 56 49 44 40 36 32 30

75

0 0 77 68 60 53 47 42 38 34 31 28

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

0.0

Angle

RC RW 1 2 3 4 5 6 7 8 9 10

85.5% 70 Yes - VDT Normal Use $3.43 based on 3000 hrs. and $0.08 per KWH

550

60

0 11474 30 11124 40 10524 45 9788 50 8674 55 7112 60 4629 65 2980 70 1164 75 42 80 0 85 0

22.5

11474 11522 10707 9940 8842 7169 4908 2802 1039 42 0 0

45.0

11474 11522 10890 9971 8473 6381 4026 1808 661 208 0 0

67.5

11474 11845 10749 9210 6916 4204 1765 484 126 42 0 0

90.0

11474 11907 10454 8707 6263 3284 904 127 63 42 0 0

1100

15

0

0.0

30 Horiz 0-180

45.0

45

Test Date 2/5/08

90.0

MICROLYNE® FAMILY QUICK REFERENCE PAGE FINDER

MR

SYMMETRIC

ASYMMETRIC

GRID/ SLOT GRID

MRA

X

MMRA

X

X

MR G

MMR

MRA G

M

MA

X

X

MM

MMA

X

X

MDI

MDIA

X

X

X

MMR, MMRA G

FLANGE

MR F

MRA F

MMR, MMRA F

PLASTER

MR P

MRA P

MMR, MMRA P

CABLE

M CM

MA CM

MM, MMA CM

SURFACE

M SM

MA SM

MM, MMA SM

WALL

M WM

MA WM

MM, MMA WM

MDI CM

MDIA CM

MDI WM

MDIA WM

Page 2/2 Rev. 12/19/16 © 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

BEAMS / M WM