M WALL MOUNT 1, 2-Lamp, T5, T5HO. 1-Lamp T8, Direct Symmetric PROJECT INFORMATION Project Name
Type
Catalog No.
Date
CONSTRUCTION Extruded aluminum housing includes typical recycled content of 25-30%. END CAPS
DI SC ON TIN UE D
Die cast flat end caps for standard lamp configuration. Both end caps feature silicone gasket to eliminate light leak, see Light Seal. Ships installed on fixture.
minimizes the visibility of fingerprints and construction dust without sacrifice to aesthetic qualities. M4R - 95% Reflective Specular Aluminum louver combine glare control and performance with a high tech, cubed aesthetic. HEP - High efficiency specular parabolic louvers maximize downlight for enhanced efficiency where maximum light output is the primary concern.
FEATURES • 3½" × 3½" rectilinear beam appears to float just off vertical surface of wall • ADA compliant • 1 or 2 T5 or T5HO, 1T8 • Extensive aesthetic options • Symmetric downlight distribution with a wide choice of shieldings • Full family including cable mount, wall mount, surface mount and recessed • Companion fixtures include the 2½" × 3½" Microlyne® Mini and 3½" × 5" Microlyne® DirectIndirect • Aesthetic continuity across family, shielding and options • Patented clips for louver retention (Patent #8,142,048)
LIGHT SEAL
Housing unions between all joints include upper formed light seal and aligner connectors to block light. End of row and single units feature unique optimized V-0 closed cell silicone gasket light seal at joints between extruded housing and die cast end cap.
DISTRIBUTION
CONNECTIONS
ELECTRICAL
Secure, simple housing connections ensure row continuity. Standard lamp configuration features patent pending Ready Connect system for end cap connections.
—All luminaires are built to UL1598 standards and bear the appropriate cUL or CSA labels. Damp location listed. —Quick connect plugs standard.
MOUNTING
FINISH
Microlyne® Wall Mount uses cleverly designed, ADA compliant, discreet wall brackets to create a floating appearance approximately 1/2” from the vertical wall surface. Brackets are made with heavy gauge galvanized steel. REFLECTOR
High reflectance formed white reflector.
SHAPE AND DIMENSIONS
Shielding is provided for single or continuous row. OA - Opal Acrylic lens emphasizes the narrow rectilinear shape by creating a pleasant glow of white along the underside of the housing. WCB – White Cross Baffle emphasizes linearity with a crisp, clean bladed appearance. MA - Matte anodized louvers incorporate an attractive but subtle grain pattern which
4"
ORDERING INFORMATION
4 8 12 __
—
—
ROW LENGTH 4' Single 8' Single 12' Single Indicate row length in 4' increments.1, 2
MODEL M Microlyne
ROW PATTERN Blank Straight P Pattern (specify) Pattern layouts require factory approval drawings.
Page 1/2 Rev. 12/19/16
CONTROLS COMPATIBILITY
Controls compatible. When used with occupancy sensors, most lamp vendors recommend program start ballasts (EP) to extend lamp life.
Name: Test #: Efficiency: LER:
M-1T5-HEP-EP 14885 85.5% 70
EXAMPLE: M-16-1DT5-WM-WCB-EP120-MW-EL
—
WM
—
—
LAMP TYPE AND PROFILE MOUNTING 1DT5 One T5 WM Wall Mount Lamp3 1DT5HO One T5HO Lamp3 1DT8 One T8 Lamp 2DT5 Two T5 Lamps 3 DOWNLIGHT SHIELDING 2DT5HO Two T5HO OA Opal Acrylic Lens Lamps 3 WCB White Cross Baffle
VOLTAGE U 120V277V 120 120V 277 277V 347 347V
COLOR MW Matte White (Std.) ZT ZET Metallic Silver See Color Selection Guide for other colors.
BALLAST E Electronic, Instant Start, (Std. for T8) EP Electronic, Programmed Start (Std. for T5 & T5HO, optional for T8) ED Electronic, Dimming (Must Specify)4 ESD Electronic, Step Dimming (Contact factory)4 Unless specified, Alera will use fewest ballasts possible.
MA Matte Anodized Low Iridescent Semi-Specular Aluminum Louver (24 Cell) M4R 95% Reflective Specular Aluminum Louver (24 Cell) HEP High Efficiency Parabolic Specular Louver (15 Cell)
Rows over 12' will be configured by Alera. Example: 16' will be (2) 8'. For alternate configurations, contact factory. 2 Shorter increments are available–contact factory. 3 Lamps may cause visible socket shadow in down light component. 1
Matte White powder coat standard for end caps and housing. Zet Silver and additional colors and finishes optional.
SHIELDING
3½"
M —
Symmetric downlight distribution is standard and used for general purpose lighting where uniform distribution is desired. Asymmetric downlight louver also available; see MA WM specification sheet.
—
OPTIONS LR Left/Right Switching (2-Lamp only) EL One Emergency Battery Pack Per Row4, 5, 7 EMC One Emergency Circuit4, 5, 6, 7 NLC Night Light Circuit4, 5, 6, 7 GLR Fast Blow Fuse GMF Slow Blow Fuse
Specify dedicated voltage. Not available with all configurations; some limitations apply. Contact factory for details. 6 One extra feed drop per EMC/NLC. For through wiring, contact factory. 7 For additional, specify quantity before nomenclature (Example: 2EL120, EMC277). 4 5
US and Canada Patents Pending. Specifications subject to change without notice.
© 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
BEAMS / M WM
M WALL MOUNT 1, 2-Lamp, T5, T5HO. 1-Lamp T8, Direct Symmetric CROSS SECTION
Opal Acrylic Lens
M4R
White Cross Baffle
HEP
Symmetric Louver
½"
Baffle
Lens
DI SC ON TIN UE D
3½"
2T5
1T8
Plaster Ring (Supplied By Others) 4" 3½" 1T5
PHOTOMETRIC DATA
LUMINAIRE DATA Test 14885 Luminaire
Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle
ZONAL LUMEN SUMMARY Zone
M-1T5-HEP-EP Microlyne® Beams 3.5" × 48" 1-Lamp with 15 Cell Louver ICN-2S28 1.04 F28T5 2600 33 0º = 19 90º = 33
0-30 0-40 0-60 0-90 0-180
ENERGY DATA
Lumens % Lamp % Fixt. 850 1388 2145 2222 2222
32.7 53.4 82.5 85.5 85.5
Total Luminaire Efficiency Luminaire Efficacy Rating (LER) IESNA RP-1-2004 Compliance
38.3 62.5 96.5 100.0 100.0
Comparative Yearly Lighting Energy Cost per 1000 Lumens
INDOOR CANDELA PLOT
CANDELA SUMMARY
90
RCR
COEFFICIENTS OF UTILIZATION (%) 70 96 89 82 76 71 66 61 57 54 50
80 50 30 93 90 83 79 75 70 68 62 62 55 56 49 51 45 47 41 43 37 40 34
10 87 75 65 57 50 45 40 36 33 30
70 93 87 80 75 69 64 60 56 53 49
50 91 82 74 67 61 55 51 46 43 40
70
30 88 78 69 61 55 49 44 40 37 34
10 86 74 65 57 50 44 40 36 33 30
50 87 79 72 65 59 54 49 45 42 39
50 30 85 76 67 60 54 48 44 40 36 33
10 83 73 64 56 49 44 40 36 32 30
75
0 0 77 68 60 53 47 42 38 34 31 28
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
0.0
Angle
RC RW 1 2 3 4 5 6 7 8 9 10
85.5% 70 Yes - VDT Normal Use $3.43 based on 3000 hrs. and $0.08 per KWH
550
60
0 11474 30 11124 40 10524 45 9788 50 8674 55 7112 60 4629 65 2980 70 1164 75 42 80 0 85 0
22.5
11474 11522 10707 9940 8842 7169 4908 2802 1039 42 0 0
45.0
11474 11522 10890 9971 8473 6381 4026 1808 661 208 0 0
67.5
11474 11845 10749 9210 6916 4204 1765 484 126 42 0 0
90.0
11474 11907 10454 8707 6263 3284 904 127 63 42 0 0
1100
15
0
0.0
30 Horiz 0-180
45.0
45
Test Date 2/5/08
90.0
MICROLYNE® FAMILY QUICK REFERENCE PAGE FINDER
MR
SYMMETRIC
ASYMMETRIC
GRID/ SLOT GRID
MRA
X
MMRA
X
X
MR G
MMR
MRA G
M
MA
X
X
MM
MMA
X
X
MDI
MDIA
X
X
X
MMR, MMRA G
FLANGE
MR F
MRA F
MMR, MMRA F
PLASTER
MR P
MRA P
MMR, MMRA P
CABLE
M CM
MA CM
MM, MMA CM
SURFACE
M SM
MA SM
MM, MMA SM
WALL
M WM
MA WM
MM, MMA WM
MDI CM
MDIA CM
MDI WM
MDIA WM
Page 2/2 Rev. 12/19/16 © 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com