PLK CABLE MOUNT 1 , 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution
AR
S
SORS
CHIT
C
FEATURES • • • • • • • • • • •
Project Name
Type
Catalog No.
Date
EN
E
PROJECT INFORMATION TURAL
Crisp shape with clean, elegant lines Direct/Indirect lighting elements Up to 3T8, T5 or T5HO lamps in cross section Heavy 20-gauge steel body Wide selection of flush or regressed shielding, baffles, and louver Optional housing patterns available–perforated, slotted, or patterned strips on either side of shielding for added visual interest Control compatible for integral daylight harvesting, occupancy sensors, or dimming systems (small case size ballasts required) Available with optional installed open or closed loop daylight sensors (DSPL, DSL) when daylight dimming systems are desired Low profile, adjustable cable mount hanging system Distribution covers can be used to customize % up/ down light for classrooms and multi-purpose areas. Excellent for office and school applications
CONSTRUCTION
LABELS AND ELECTRICAL
—Modular mounting points maintain convenient, predictable locations. —The exact shape of the housing is maintained by the use of a patented inner die-cast plate at each fixture end (Patent# 6,796,676 B2) throughout the run to prevent snaking. The housing is designed to wrap around the plate and secures on top with concealed screws to ensure housing tolerances are consistent.
—All luminaires are built to UL1598 standards and bear the appropriate cUL or CSA labels. Damp location listed.
FINISH Housing and all painted parts are treated with a multistage phosphate prior to finish. Parts are then finished with a white powder coat for maximum consistent coverage and longevity. Other colors may be specified; refer to page Color Selection Guide or contact your local Alera Lighting representative.
SHIELDING —White Cross Baffle with opal overlay (WCB) —White Cross Baffle-high efficiency without overlay (WCBS) —Regressed Perforated panel (RPF) —Flat Perforated panel (FPF) —Opal Acrylic lens (OA) —Acrylic Pattern 12 Lens (A12) —Semi-specular parabolic louver (LD). For a dramatic touch, colored lensing material may be selected as an overlay; contact factory.
—Quick connect plugs standard.
CONTROLS COMPATIBILITY
Controls compatible. When used with Occupancy Sensors, most lamp vendors recommend Program Start ballast (EP) to extend lamp life. For daylight sensors installed, see information below.
ARCHITECTURAL SENSORS INSTALLED
Daylight sensors are used to measure available sunlight and reduce electric light for energy savings. Alera sensors are installed to be both accessible and visible below the housing DSPL: Philips Luxsense, Mark 7 0-10V dimming ballast. Closed loop sensor measures reflected light in a cone below the sensor. Pre-commissioned by Philips to 45fc standard; modest manual adjustability via sensor ring. DSL: Lutron EcoSystem, digital dimming ballast. Open loop sensor must be pointed directly at the source of natural light. System requires proprietary commissioning by others. Additional technical data: see TID sheets, Alera website and sensor manufacturer websites.
DISTRIBUTION —The standard distribution–20-30% down light. —Our (CLC) Center Lamp Cover directs 100% of the center lamp light down.
SHAPE AND DIMENSIONS 2"
MOUNTING To maintain consistent, predictable mounting points, fixtures use an adjustable aircraft cable yoke mounting mechanism from two points at each hanging location.
97⁄8"
ORDERING INFORMATION
PLK —
—
Name: Test #: Efficiency: LER:
PLK-2T8-PERF-WCB-E 13890 92% 80
EXAMPLE: PLK-24-3T5HO-PFST-CM48-WCB-EPU-MW
—
—
— CM
—
—
—
—
VOLTAGE FINISH U 120VMW Matte White (Std.) 277V ZT ZET Metallic 120 120V Silver ROW LENGTH 277 277V See Color Selection Guide 4 4' Single for other colors. 347 347V 8 8' Single HOUSING TYPE SHIELDING BALLAST OPTIONS 12 12' Single 1 Blank Solid (Std.) WCB White Cross Baffle E Electronic, DC Dust Cover (T8 only) 6, 7, 8 — Indicate Instant Start (Std. LR Left/Right Switching RPF Regressed PFST Perforated Strip row length for T8) (2-Lamp only) Perforated over 12' in 4' HSLT Horizontal Slot EP Electronic, IBOB Inboard/Outboard increments DISTRIBUTION FPF Flat Perforated Strip Programmed Switching (3-Lamp only) Note: Rows Blank None OA Opal Acrylic Lens VSLT Vertical Slot Strip Start (Std. for T5 over 12' will be EL One Emergency Battery 0/100 0% Uplight Reflector, & T5HO, optional A12 Pattern 12 .125" CLD Custom Laser Cut configured by Pack 2, 3 100% Downlight 6, 7 for T8) Alera. Example: Thick Acrylic Lens Design Strip EMC One Emergency 20/80 20% Uplight Reflector, 16' will be (2) ED Electronic, LD Low Iridescent IND Indirect only Circuit3, 4 8'. Alternate 80% Downlight 6, 7, 8 Dimming (Must Semi-Specular housing (solid configurations: NLC Night Light Circuit3, 4 40/60 40% Uplight Reflector, specify) Parabolic Louver bottoms) contact factory. 60% Downlight 6, 7, 8 GLR Fast Blow Fuse ESD Electronic, Step WCBS White Cross Baffle– 85/15 85% Uplight Reflector, GMF Slow Blow Fuse Dimming High Efficiency 6, 7 15% Downlight EDUMK7 Universal Voltage, TBAR T-Bar Mounting Without Overlay CLC Center Lamp Cover Electronic DSPL Philips LuxSense 6, 7, 8 A/V Mode Dimming Philips Daylight Sensor (Must 1 Includes .020 thick white overlay. Advance Mark 7 Specify Philips Advance 2 Specify voltage. For additional, specify quantity before nomenclature (Example: 2EL120). (0-10V) 0-10V Dimming Ballast)3 3 Not available with all configurations; some limitations apply. Contact factory for details. EDULUTES Universal Voltage, DSL Lutron Daylight Sensor 4 One extra feed drop per EMC/NLC. For through wiring, contact factory. Lutron EcoSystem (Must Specify Lutron 5 Lutron EcoSystem® series ballast. Contact factory for other Lutron ballasts. Digital Dimming EcoSystem (EC5 Series) 6 Dust cover not available when using optical distribution covers. Ballast 3, 5 Dimming Ballast)3, 5 7 Ships separately. 8 Optional distribution's pattern results vary according to lamp configurations. Contact factory for additional information. Unless specified, Alera will use fewest ballasts possible. Page 1/6 Rev. 11/28/16 BEAMS / PLK CM Protected by US Patent 6,796,676. Protected by Canada Patent 2,450,528. Specifications subject to change without notice. MODEL PLK Plank
LAMP TYPE AND PROFILE 1T5 One T5 Lamp 2T5 Two T5 Lamps 3T5 Three T5 Lamps 1T5HO One T5HO Lamp 2T5HO Two T5HO Lamps 3T5HO Three T5HO Lamps 1T8 One T8 Lamp 2T8 Two T8 Lamps 3T8 Three T8 Lamps
MOUNTING METHOD CM Adj. Aircraft Cable Mount (Std.)
SUSPENSION LENGTH 48 48" 96 96" Other lengths available on request.
© 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
PLK CABLE MOUNT 1 , 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution CROSS SECTION
2"
2"
9⅞" 1T8 Lamp
2"
9⅞" 2T8 Lamps
9⅞" 3T8 Lamps
2"
2"
9⅞" 1T5, T5HO Lamp
2"
9⅞" 2T5, T5HO Lamps
9⅞" 3T5, T5HO Lamps
PHOTOMETRIC DATA
Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet
PLK-1T8-WCB-E Plank Architectural Beam 9.75 × 48 1-Lamp with Gloss White Cross Baffle and Opal Overlay REL-1P32-SC 0.92 F32T8 2900 34 0º = 90 90º = 90 0º = 1.03 90º = 1.25 Length: 3.67 Width: 0.25 Height: 0.00
AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5 90.0
3344 2587 2205 1974 1697 1493 1408 1332 1269 1224 1216 1212
3344 2642 2297 2074 1843 1554 1455 1360 1269 1269 1216 1077
3344 2831 2542 2373 2190 1964 1713 1555 1441 1315 1216 808
3344 3089 2894 2771 2628 2434 2135 1638 1338 1179 1013 673
3344 3265 3155 3069 2957 2741 2276 1555 1166 1133 946 673
ZONAL LUMEN SUMMARY Zone
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
Lumens % Lamp % Fixt. 207 327 529 620 774 1138 1767 2179 2799
7.1 11.3 18.2 21.4 26.7 39.2 60.9 75.1 96.5
7.4 11.7 18.9 22.1 27.7 40.6 63.1 77.9 100.0
RCR
Luminaire
Angle
LUMINAIRE DATA Test 14038
RC RW 1 2 3 4 5 6 7 8 9 10
70 89 81 74 67 62 57 52 48 45 42
80 50 30 85 81 74 69 65 59 58 51 51 44 46 38 41 34 37 30 34 27 31 24
10 78 64 53 45 38 33 29 25 22 20
70 78 71 65 60 55 50 46 43 40 37
70 50 30 75 72 66 61 58 53 51 45 46 40 41 35 37 31 33 27 30 24 28 22
10 70 57 48 41 35 30 26 23 20 18
50 58 51 45 40 35 32 29 26 24 22
50 30 56 48 41 36 31 27 24 22 20 18
10 54 45 38 32 28 24 21 19 17 15
INDOOR CANDELA PLOT 0 0 18 16 14 12 10 9 8 7 7 6
180 165 600
150
120 300 105 90
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
135
300
96.5% 76 Yes-VDT Intensive Use $3.16 based on 3000 hrs. and $0.08 per KWH
60
600 0 0.0
45 15 30 Horiz 0-180 90.0 45.0 Test Date 9/16/05
PHOTOMETRIC DATA
Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet
PLK-1T8-RPF-E Plank Architectural Beam 9.75 × 48 1-Lamp with Gloss White Regress Basket and Opal Overlay REL-1P32-SC 0.92 F32T8 2900 33 0º = 90 90º = 90 0º = 1.24 90º = 1.22 Length: 3.67 Width: 0.25 Height: 0.00
AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5 90.0
1713 1666 1593 1526 1460 1350 1220 1083 892 680 608 538
1713 1653 1547 1493 1424 1329 1197 1055 892 725 608 538
1713 1653 1547 1477 1405 1309 1197 1055 823 589 540 538
1713 1639 1531 1460 1387 1268 1126 916 652 499 473 538
1713 1626 1516 1443 1351 1248 1079 833 583 499 473 538
ZONAL LUMEN SUMMARY Zone
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
Lumens % Lamp % Fixt. 113 183 309 363 812 1204 1883 2324 2687
3.9 6.3 10.6 12.5 28.0 41.5 64.9 80.1 92.7
4.2 6.8 11.5 13.5 30.2 44.8 70.1 86.5 100.0
RCR
Luminaire
Angle
LUMINAIRE DATA Test 14034
RC RW 1 2 3 4 5 6 7 8 9 10
70 83 76 69 63 58 53 49 45 42 39
80 50 30 79 76 69 64 61 55 54 47 48 41 43 36 38 31 34 28 31 25 28 22
10 73 60 50 42 36 31 26 23 20 18
70 73 66 60 55 50 46 43 39 36 34
70 50 30 70 67 61 57 54 48 47 42 42 36 37 32 34 28 30 25 28 22 25 20
10 64 53 44 37 32 27 24 21 18 16
50 51 45 40 35 31 28 25 23 21 19
50 30 49 42 36 31 27 24 21 19 17 15
10 48 40 33 28 24 21 18 16 14 12
INDOOR CANDELA PLOT 0 0 11 9 8 7 6 5 5 4 4 3
180 165 600
135
120 300 105 90
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
150
300
92.7% 75 Yes-VDT Intensive Use $3.20 based on 3000 hrs. and $0.08 per KWH
60
600 0 0.0
15 30 45 Horiz 0-180 90.0 45.0 Test Date 9/9/05
Page 2/6 Rev. 11/28/16 © 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
BEAMS / PLK CM
PLK CABLE MOUNT 1 , 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution PHOTOMETRIC DATA
Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet
PLK-2T8-WCB-E Plank Architectural Beam 9.75 × 48 2-Lamp with Gloss White Center Louver and Side Reflectors REL-2P32-SC 0.88 F32T8 2900 63 0º = 90 90º = 90 0º = 1.03 90º = 1.23 Length: 3.67 Width: 0.25 Height: 0.00
AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5 90.0
8095 6259 5314 4745 4107 3579 3402 3220 3053 2992 3040 3365
8095 6435 5544 5011 4435 3784 3473 3276 3121 3128 3175 3365
8095 6882 6126 5691 5183 4643 4059 3692 3499 3309 3243 3365
8095 7451 6876 6504 6059 5543 4974 4331 3636 3309 3243 3231
8095 7762 7366 7051 6662 6095 5467 4608 3567 3264 3243 3231
ZONAL LUMEN SUMMARY Zone
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
Lumens % Lamp % Fixt. 502 790 1266 1506 1211 1907 3221 4108 5613
8.7 13.6 21.8 26.0 20.9 32.9 55.5 70.8 96.8
8.9 14.1 22.6 26.8 21.6 34.0 57.4 73.2 100.0
RCR
Luminaire
Angle
LUMINAIRE DATA Test 14014
RC RW 1 2 3 4 5 6 7 8 9 10
70 90 82 75 68 63 58 53 49 46 43
80 50 30 86 82 75 70 66 59 59 51 52 45 47 39 42 35 38 31 35 28 32 25
10 79 65 54 46 39 34 30 26 23 20
70 80 73 67 61 56 51 48 44 41 38
70 50 30 77 74 67 63 59 54 53 46 47 41 42 36 38 32 34 28 31 25 29 23
10 71 59 49 42 36 31 27 24 21 19
50 60 53 47 41 37 33 30 27 25 23
50 30 58 49 43 37 33 29 26 23 21 19
10 56 47 39 34 29 25 22 20 17 16
INDOOR CANDELA PLOT 0 0 22 19 16 14 12 11 10 9 8 7
180 165 1100
150
120 550 105 90
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
135
550
96.8% 78 Yes-VDT Intensive Use $3.08 based on 3000 hrs. and $0.08 per KWH
60
1100 0 0.0
15 30 45 Horiz 0-180 90.0 45.0 Test Date 9/18/07
PHOTOMETRIC DATA
Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet
PLK-2T8-PERF-WCB-E Plank Architectural Beam 9.75 × 48 2-Lamp with Gloss White Center Louver and Side Reflectors ICN-2M32-MC 0.88 F32T8 2900 62 0º = 90 90º = 90 0º = 1.03 90º = 1.23 Length: 3.67 Width: 0.25 Height: 0.00
AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5 90.0
7438 5784 4977 4496 3924 3293 3027 2859 2744 2674 2702 3096
7438 5933 5161 4695 4143 3518 3074 2887 2744 2720 2702 2692
7438 6245 5590 5193 4745 4213 3660 3220 3053 2856 2702 2423
7438 6692 6172 5824 5439 4950 4388 3803 3190 2810 2567 2288
7438 7126 6784 6504 6169 5666 5068 4303 3156 2538 2432 2154
ZONAL LUMEN SUMMARY Zone
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
Lumens % Lamp % Fixt. 460 724 1161 1370 1167 1839 3106 3965 5335
7.9 12.5 20.0 23.6 20.1 31.7 53.6 68.4 92.0
8.6 13.6 21.8 25.7 21.9 34.5 58.2 74.3 100.0
RCR
Luminaire
Angle
LUMINAIRE DATA Test 13890
RC RW 1 2 3 4 5 6 7 8 9 10
70 85 78 71 65 60 55 51 47 43 40
80 50 30 81 78 71 66 63 56 56 49 49 42 44 37 40 33 36 29 33 26 30 24
10 75 62 51 43 37 32 28 25 22 19
70 76 69 63 58 53 49 45 42 39 36
70 50 30 73 70 64 59 56 51 50 44 44 38 40 34 36 30 33 27 30 24 27 22
10 67 56 47 40 34 29 26 23 20 18
50 56 50 44 39 35 31 28 26 24 22
50 30 55 47 40 35 31 27 24 22 19 18
10 53 44 37 32 27 24 21 18 16 15
INDOOR CANDELA PLOT 0 0 20 17 15 13 11 10 9 8 7 7
180
165
150
135
1100 120 550 105 90
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
92.0% 80 Yes-VDT Intensive Use $3.00 based on 3000 hrs. and $0.08 per KWH
60
550
1100 0 0.0
15 30 45 Horiz 0-180 90.0 45.0 Test Date 3/24/05
Page 3/6 Rev. 11/28/16 © 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
BEAMS / PLK CM
PLK CABLE MOUNT 1 , 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution PHOTOMETRIC DATA
Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet
PLK-2T8-RPF-E Plank Architectural Beam 9.75 × 48 2-Lamp with Gloss White Regress Basket and Opal Overlay REL-2P32-SC 0.88 F32T8 2900 62 0º = 90 90º = 90 0º = 1.24 90º = 1.21 Length: 3.67 Width: 0.25 Height: 0.00
AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5 90.0
5033 4863 4625 4463 4234 3968 3590 3137 2538 1994 1621 1615
5033 4850 4594 4430 4198 3907 3543 3054 2470 1994 1554 1615
5033 4850 4548 4330 4052 3702 3285 2776 2230 1677 1621 1615
5033 4796 4457 4198 3869 3436 2933 2387 1818 1496 1486 1481
5033 4755 4380 4098 3742 3293 2769 2221 1681 1451 1419 1346
ZONAL LUMEN SUMMARY Zone
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
Lumens % Lamp % Fixt. 333 538 898 1050 1267 2013 3420 4376 5426
5.7 9.3 15.5 18.1 21.8 34.7 59.0 75.5 93.6
6.1 9.9 16.5 19.3 23.4 37.1 63.0 80.7 100.0
RCR
Luminaire
Angle
LUMINAIRE DATA Test 14031
RC RW 1 2 3 4 5 6 7 8 9 10
70 85 78 71 65 59 54 50 46 43 40
80 50 30 81 78 71 66 63 56 55 48 49 42 44 37 39 32 36 29 32 26 29 23
10 75 61 51 43 37 32 27 24 21 19
70 75 68 62 57 52 48 44 41 38 35
70 50 30 72 69 63 59 56 50 49 43 44 38 39 33 35 29 32 26 29 23 26 21
10 67 55 46 39 33 29 25 22 19 17
50 54 48 42 37 33 30 27 24 22 20
50 30 53 45 39 33 29 26 23 20 18 16
10 51 42 36 30 26 23 20 17 15 14
INDOOR CANDELA PLOT 0 0 16 13 11 10 9 8 7 6 5 5
180
165
150
120 600 105 90
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
135
1200
600
93.6% 77 Yes-VDT Intensive Use $3.12 based on 3000 hrs. and $0.08 per KWH
60
1200 0 0.0
15 30 45 Horiz 0-180 90.0 45.0 Test Date 9/18/07
PHOTOMETRIC DATA
Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet
PLK-3T8-WCB-E Plank Architectural Beam 9.75 × 48 3-Lamp with Gloss White Center Louver and Side Reflectors REL-3P32-SC 0.88 F32T8 2900 88 0º = 90 90º = 90 0º = 1.02 90º = 1.17 Length: 3.67 Width: 0.25 Height: 0.00
AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5 90.0
12424 9523 8071 7201 6187 5420 5092 4802 4494 4306 4256 4308
12424 9632 8239 7433 6516 5584 5162 4830 4528 4442 4256 3904
12424 10079 8852 8179 7447 6668 5889 5385 5077 4669 4256 3500
12424 10770 9801 9291 8797 8243 7579 6829 5934 5031 4459 3500
12424 11230 10537 10187 9819 9368 8799 7967 6860 5394 4662 3500
ZONAL LUMEN SUMMARY Zone
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
Lumens % Lamp % Fixt. 752 1173 1871 2224 1518 2517 4463 5794 8018
8.6 13.5 21.5 25.6 17.4 28.9 51.3 66.6 92.2
9.4 14.6 23.3 27.7 18.9 31.4 55.7 72.3 100.0
RCR
Luminaire
Angle
LUMINAIRE DATA Test 14017
RC RW 1 2 3 4 5 6 7 8 9 10
70 86 78 71 65 60 55 51 47 44 41
80 50 30 82 79 72 66 63 57 56 49 50 43 45 38 40 33 36 30 33 27 30 24
10 76 62 52 44 38 32 28 25 22 20
70 77 70 64 58 53 49 45 42 39 37
70 50 30 73 71 64 60 57 51 50 45 45 39 40 34 36 30 33 27 30 24 27 22
10 68 56 47 40 34 30 26 23 20 18
50 57 51 45 40 36 32 29 26 24 22
50 30 56 48 41 36 31 28 25 22 20 18
10 54 45 38 32 28 24 21 19 17 15
INDOOR CANDELA PLOT 0 0 22 19 16 14 12 11 10 9 8 7
180
165
135
120 850 105 90
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
150
1700
850
92.2% 80 Yes-VDT Normal Use $3.00 based on 3000 hrs. and $0.08 per KWH
60
1700 0 0.0
15 30 45 Horiz 0-180 90.0 45.0 Test Date 8/11/05
Page 4/6 Rev. 11/28/16 © 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
BEAMS / PLK CM
PLK CABLE MOUNT 1 , 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution PHOTOMETRIC DATA
Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet
PLK-1T5HO-WCB-EP Plank Architectural Beam 9.75 × 48 1-Lamp with Gloss White Center Louver and Opal Overlay ICN2S5490C 1.02 F54T5HO 4450 62 0º = 90 90º = 90 0º = 1.03 90º = 1.25 Length: 3.67 Width: 0.25 Height: 0.00
AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5 90.0
4540 3509 2971 2671 2318 2045 1924 1832 1749 1677 1757 1750
4540 3603 3124 2837 2519 2168 1994 1888 1818 1813 1757 1615
4540 3888 3492 3252 2975 2679 2370 2165 2024 1904 1824 1615
4540 4240 3967 3750 3504 3129 2651 2249 1989 1904 1757 1481
4540 4430 4242 4048 3778 3334 2745 2221 1887 1813 1757 1481
ZONAL LUMEN SUMMARY Zone
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
Lumens % Lamp % Fixt. 282 446 716 847 1225 1793 2785 3434 4281
6.3 10.0 16.1 19.0 27.5 40.3 62.6 77.2 96.2
6.6 10.4 16.7 19.8 28.6 41.9 65.0 80.2 100.0
RCR
Luminaire
Angle
LUMINAIRE DATA Test 14020
RC RW 1 2 3 4 5 6 7 8 9 10
70 88 80 73 67 61 56 52 48 44 41
80 50 30 84 80 73 68 64 58 57 50 51 43 45 38 41 33 37 30 33 27 30 24
10 77 63 53 44 38 33 28 25 22 20
70 77 70 64 59 54 49 46 42 39 37
70 50 30 74 71 65 60 57 52 51 45 45 39 40 34 36 30 33 27 30 24 27 22
10 69 57 47 40 34 30 26 23 20 18
50 56 49 44 39 35 31 28 25 23 21
50 30 54 46 40 35 30 27 24 21 19 17
10 53 44 37 31 27 23 20 18 16 14
INDOOR CANDELA PLOT 0 0 16 14 12 10 9 8 7 7 6 5
180
165
150
120 400 105 90
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
135
800
400
96.2% 70 Yes-VDT Intensive Use $3.43 based on 3000 hrs. and $0.08 per KWH
60
800 0 0.0
15 30 45 Horiz 0-180 90.0 45.0 Test Date 8/15/05
PHOTOMETRIC DATA
Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet
PLK-1T5HO-RPF-EP Plank Architectural Beam 9.75 × 48 1-Lamp with Regress Perforated Basket and Opal Overlay ICN-2S54 1.02 F54T5HO 4450 63 0º = 90 90º = 90 0º = 1.24 90º = 1.21 Length: 3.67 Width: 0.25 Height: 0.00
AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5
2276 2208 2098 2024 1916 1800 1642 1444 1166 952 878 942
2276 2181 2067 1991 1898 1759 1619 1416 1166 997 878 808
2276 2167 2037 1958 1843 1718 1596 1416 1166 907 811 808
2276 2154 2022 1908 1807 1677 1478 1249 960 771 743 673
90.0 2276 2140 1976 1875 1770 1616 1408 1138 858 725 676 673
ZONAL LUMEN SUMMARY Zone
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
Lumens % Lamp % Fixt. 150 242 408 484 1314 1945 3061 3804 4287
3.4 5.4 9.2 10.9 29.5 43.7 68.8 85.5 96.3
3.5 5.6 9.5 11.3 30.7 45.4 71.4 88.7 100.0
RCR
Luminaire
Angle
LUMINAIRE DATA Test 14036
RC RW 1 2 3 4 5 6 7 8 9 10
70 86 78 71 65 60 55 50 46 43 40
80 50 30 82 79 72 66 63 56 56 48 49 42 44 37 39 32 35 28 32 25 29 23
10 75 62 51 43 37 31 27 24 21 18
70 75 68 62 56 52 47 44 40 37 35
70 50 30 72 69 63 58 55 50 49 43 43 37 39 32 35 28 31 25 28 22 26 20
10 66 54 45 38 33 28 24 21 19 16
50 52 46 40 36 32 28 25 23 21 19
50 30 50 43 37 32 28 24 21 19 17 15
10 49 40 34 29 25 21 18 16 14 13
INDOOR CANDELA PLOT 0 0 9 8 7 6 5 4 4 4 3 3
180 165 1000
135
120 500 105 90
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
150
500
96.3% 69 Yes-VDT Intensive Use $3.48 based on 3000 hrs. and $0.08 per KWH
60
1000 0 0.0
15 30 45 Horiz 0-180 90.0 45.0 Test Date 9/13/05
Page 5/6 Rev. 11/28/16 © 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
BEAMS / PLK CM
PLK CABLE MOUNT 1 , 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution PHOTOMETRIC DATA
Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet
PLK-2T5HO-WCB-EP Plank Architectural Beam 9.75 × 48 2-Lamp with Gloss White Center Louver and Opal Overlay ICN2S5490C 1.00 F54T5HO 4450 121 0º = 90 90º = 90 0º = 1.02 90º = 1.21 Length: 3.67 Width: 0.25 Height: 0.00
AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5 90.0
9890 7573 6417 5724 4964 4377 4153 3942 3739 3626 3716 3904
9890 7749 6647 6023 5275 4541 4200 3970 3773 3717 3581 3231
9890 8263 7275 6686 6078 5400 4834 4469 4288 3944 3783 3096
9890 8900 8071 7549 7063 6484 5913 5274 4494 4034 3716 2692
9890 9279 8592 8179 7720 7220 6617 5746 4596 4125 3783 2827
ZONAL LUMEN SUMMARY Zone
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
Lumens % Lamp % Fixt. 608 952 1514 1798 2078 3203 5222 6569 8366
6.8 10.7 17.0 20.2 23.4 36.0 58.7 73.8 94.0
7.3 11.4 18.1 21.5 24.8 38.3 62.4 78.5 100.0
RCR
Luminaire
Angle
LUMINAIRE DATA Test 14021
RC RW 1 2 3 4 5 6 7 8 9 10
70 86 78 72 66 60 55 51 47 44 41
80 50 30 82 79 72 67 63 57 56 49 50 43 45 37 40 33 36 29 33 26 30 24
10 76 62 52 44 37 32 28 25 22 19
70 76 69 63 58 53 49 45 42 39 36
70 50 30 73 70 64 60 56 51 50 44 44 38 40 34 36 30 32 27 30 24 27 21
10 68 56 47 39 34 29 25 22 20 18
50 56 49 43 38 34 31 28 25 23 21
50 30 54 46 40 34 30 27 24 21 19 17
10 52 43 37 31 27 23 20 18 16 14
INDOOR CANDELA PLOT 0 0 17 15 13 11 10 9 8 7 6 6
180
165
150
120 850 105 90
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
135
1700
850
94.0% 69 Yes-VDT Normal Use $3.48 based on 3000 hrs. and $0.08 per KWH
60
1700 0 0.0
15 30 45 Horiz 0-180 90.0 45.0 Test Date 8/17/05
PHOTOMETRIC DATA
Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet
PLK-3T5HO-WCB-EP Plank Architectural Beam 9.75 × 48 3-Lamp with Gloss White Center Louver and Opal Overlay ICN-4S5490C-2LS 1.00 F54T5HO 4450 183 0º = 90 90º = 90 0º = 1.02 90º = 1.16 Length: 3.67 Width: 0.25 Height: 0.00
AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5 90.0
16049 12260 10368 9225 7958 6995 6617 6274 5900 5757 5810 5923
16049 12409 10583 9540 8396 7220 6711 6302 5900 5893 5743 5115
16049 13005 11425 10585 9673 8693 7743 7162 6757 6255 5945 4846
16049 13736 12558 11879 11225 10431 9479 8467 7306 6391 5608 4577
16049 14400 13554 13074 12557 11863 10864 9716 8198 6845 5878 4308
ZONAL LUMEN SUMMARY Zone
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
Lumens % Lamp % Fixt. 968 1510 2405 2861 2725 4341 7284 9259 12120
7.3 11.3 18.0 21.4 20.4 32.5 54.8 69.4 90.8
8.0 12.5 19.8 23.6 22.5 35.8 60.1 76.4 100.0
RCR
Luminaire
Angle
LUMINAIRE DATA Test 14024
RC RW 1 2 3 4 5 6 7 8 9 10
70 84 76 70 64 58 54 50 46 43 40
80 50 30 80 77 70 65 62 55 54 48 48 41 43 36 39 32 35 29 32 26 29 23
10 74 60 50 43 36 31 27 24 21 19
70 74 68 62 56 52 48 44 41 38 35
70 50 30 71 68 62 58 55 50 49 43 43 37 39 33 35 29 32 26 29 23 26 21
10 66 54 45 39 33 29 25 22 19 17
50 55 48 43 38 34 30 27 25 23 21
50 30 53 45 39 34 30 26 23 21 19 17
10 51 43 36 31 26 23 20 18 16 14
INDOOR CANDELA PLOT 0 0 18 16 13 12 10 9 8 7 7 6
180
165
150
135
2600 120 1300 105 90
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
90.8% 66 Noncompliant $3.64 based on 3000 hrs. and $0.08 per KWH
1300
60
2600 0 0.0
15 30 45 Horiz 0-180 90.0 45.0 Test Date 9/6/05
Page 6/6 Rev. 11/28/16 © 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com
BEAMS / PLK CM