plk cable mount - Alera Lighting

Report 6 Downloads 149 Views
PLK CABLE MOUNT 1 , 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution

AR

S

SORS

CHIT

C

FEATURES • • • • • • • • • • •

Project Name

Type

Catalog No.

Date

EN

E

PROJECT INFORMATION TURAL

Crisp shape with clean, elegant lines Direct/Indirect lighting elements Up to 3T8, T5 or T5HO lamps in cross section Heavy 20-gauge steel body Wide selection of flush or regressed shielding, baffles, and louver Optional housing patterns available–perforated, slotted, or patterned strips on either side of shielding for added visual interest Control compatible for integral daylight harvesting, occupancy sensors, or dimming systems (small case size ballasts required) Available with optional installed open or closed loop daylight sensors (DSPL, DSL) when daylight dimming systems are desired Low profile, adjustable cable mount hanging system Distribution covers can be used to customize % up/ down light for classrooms and multi-purpose areas. Excellent for office and school applications

CONSTRUCTION

LABELS AND ELECTRICAL

—Modular mounting points maintain convenient, predictable locations. —The exact shape of the housing is maintained by the use of a patented inner die-cast plate at each fixture end (Patent# 6,796,676 B2) throughout the run to prevent snaking. The housing is designed to wrap around the plate and secures on top with concealed screws to ensure housing tolerances are consistent.

—All luminaires are built to UL1598 standards and bear the appropriate cUL or CSA labels. Damp location listed.

FINISH Housing and all painted parts are treated with a multistage phosphate prior to finish. Parts are then finished with a white powder coat for maximum consistent coverage and longevity. Other colors may be specified; refer to page Color Selection Guide or contact your local Alera Lighting representative.

SHIELDING —White Cross Baffle with opal overlay (WCB) —White Cross Baffle-high efficiency without overlay (WCBS) —Regressed Perforated panel (RPF) —Flat Perforated panel (FPF) —Opal Acrylic lens (OA) —Acrylic Pattern 12 Lens (A12) —Semi-specular parabolic louver (LD). For a dramatic touch, colored lensing material may be selected as an overlay; contact factory.

—Quick connect plugs standard.

CONTROLS COMPATIBILITY

Controls compatible. When used with Occupancy Sensors, most lamp vendors recommend Program Start ballast (EP) to extend lamp life. For daylight sensors installed, see information below.

ARCHITECTURAL SENSORS INSTALLED

Daylight sensors are used to measure available sunlight and reduce electric light for energy savings. Alera sensors are installed to be both accessible and visible below the housing DSPL: Philips Luxsense, Mark 7 0-10V dimming ballast. Closed loop sensor measures reflected light in a cone below the sensor. Pre-commissioned by Philips to 45fc standard; modest manual adjustability via sensor ring. DSL: Lutron EcoSystem, digital dimming ballast. Open loop sensor must be pointed directly at the source of natural light. System requires proprietary commissioning by others. Additional technical data: see TID sheets, Alera website and sensor manufacturer websites.

DISTRIBUTION —The standard distribution–20-30% down light. —Our (CLC) Center Lamp Cover directs 100% of the center lamp light down.

SHAPE AND DIMENSIONS 2"

MOUNTING To maintain consistent, predictable mounting points, fixtures use an adjustable aircraft cable yoke mounting mechanism from two points at each hanging location.

97⁄8"

ORDERING INFORMATION

PLK —



Name: Test #: Efficiency: LER:

PLK-2T8-PERF-WCB-E 13890 92% 80

EXAMPLE: PLK-24-3T5HO-PFST-CM48-WCB-EPU-MW





— CM









VOLTAGE FINISH U 120VMW Matte White (Std.) 277V ZT ZET Metallic 120 120V Silver ROW LENGTH 277 277V See Color Selection Guide 4 4' Single for other colors. 347 347V 8 8' Single HOUSING TYPE SHIELDING BALLAST OPTIONS 12 12' Single 1 Blank Solid (Std.) WCB White Cross Baffle E Electronic, DC Dust Cover (T8 only) 6, 7, 8 — Indicate Instant Start (Std. LR Left/Right Switching RPF Regressed PFST Perforated Strip row length for T8) (2-Lamp only) Perforated over 12' in 4' HSLT Horizontal Slot EP Electronic, IBOB Inboard/Outboard increments DISTRIBUTION FPF Flat Perforated Strip Programmed Switching (3-Lamp only) Note: Rows Blank None OA Opal Acrylic Lens VSLT Vertical Slot Strip Start (Std. for T5 over 12' will be EL One Emergency Battery 0/100 0% Uplight Reflector, & T5HO, optional A12 Pattern 12 .125" CLD Custom Laser Cut configured by Pack 2, 3 100% Downlight 6, 7 for T8) Alera. Example: Thick Acrylic Lens Design Strip EMC One Emergency 20/80 20% Uplight Reflector, 16' will be (2) ED Electronic, LD Low Iridescent IND Indirect only Circuit3, 4 8'. Alternate 80% Downlight 6, 7, 8 Dimming (Must Semi-Specular housing (solid configurations: NLC Night Light Circuit3, 4 40/60 40% Uplight Reflector, specify) Parabolic Louver bottoms) contact factory. 60% Downlight 6, 7, 8 GLR Fast Blow Fuse ESD Electronic, Step WCBS White Cross Baffle– 85/15 85% Uplight Reflector, GMF Slow Blow Fuse Dimming High Efficiency 6, 7 15% Downlight EDUMK7 Universal Voltage, TBAR T-Bar Mounting Without Overlay CLC Center Lamp Cover Electronic DSPL Philips LuxSense 6, 7, 8 A/V Mode Dimming Philips Daylight Sensor (Must 1 Includes .020 thick white overlay. Advance Mark 7 Specify Philips Advance 2 Specify voltage. For additional, specify quantity before nomenclature (Example: 2EL120). (0-10V) 0-10V Dimming Ballast)3 3 Not available with all configurations; some limitations apply. Contact factory for details. EDULUTES Universal Voltage, DSL Lutron Daylight Sensor 4 One extra feed drop per EMC/NLC. For through wiring, contact factory. Lutron EcoSystem (Must Specify Lutron 5 Lutron EcoSystem® series ballast. Contact factory for other Lutron ballasts. Digital Dimming EcoSystem (EC5 Series) 6 Dust cover not available when using optical distribution covers. Ballast 3, 5 Dimming Ballast)3, 5 7 Ships separately. 8 Optional distribution's pattern results vary according to lamp configurations. Contact factory for additional information. Unless specified, Alera will use fewest ballasts possible. Page 1/6 Rev. 11/28/16 BEAMS / PLK CM Protected by US Patent 6,796,676. Protected by Canada Patent 2,450,528. Specifications subject to change without notice. MODEL PLK Plank

LAMP TYPE AND PROFILE 1T5 One T5 Lamp 2T5 Two T5 Lamps 3T5 Three T5 Lamps 1T5HO One T5HO Lamp 2T5HO Two T5HO Lamps 3T5HO Three T5HO Lamps 1T8 One T8 Lamp 2T8 Two T8 Lamps 3T8 Three T8 Lamps

MOUNTING METHOD CM Adj. Aircraft Cable Mount (Std.)

SUSPENSION LENGTH 48 48" 96 96" Other lengths available on request.

© 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

PLK CABLE MOUNT 1 , 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution CROSS SECTION

2"

2"

9⅞" 1T8 Lamp

2"

9⅞" 2T8 Lamps

9⅞" 3T8 Lamps

2"

2"

9⅞" 1T5, T5HO Lamp

2"

9⅞" 2T5, T5HO Lamps

9⅞" 3T5, T5HO Lamps

PHOTOMETRIC DATA

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

PLK-1T8-WCB-E Plank Architectural Beam 9.75 × 48 1-Lamp with Gloss White Cross Baffle and Opal Overlay REL-1P32-SC 0.92 F32T8 2900 34 0º = 90  90º = 90 0º = 1.03  90º = 1.25 Length: 3.67 Width: 0.25 Height: 0.00

AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

3344 2587 2205 1974 1697 1493 1408 1332 1269 1224 1216 1212

3344 2642 2297 2074 1843 1554 1455 1360 1269 1269 1216 1077

3344 2831 2542 2373 2190 1964 1713 1555 1441 1315 1216 808

3344 3089 2894 2771 2628 2434 2135 1638 1338 1179 1013 673

3344 3265 3155 3069 2957 2741 2276 1555 1166 1133 946 673

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 207 327 529 620 774 1138 1767 2179 2799

7.1 11.3 18.2 21.4 26.7 39.2 60.9 75.1 96.5

7.4 11.7 18.9 22.1 27.7 40.6 63.1 77.9 100.0

RCR

Luminaire

Angle

LUMINAIRE DATA Test 14038

RC RW 1 2 3 4 5 6 7 8 9 10

70 89 81 74 67 62 57 52 48 45 42

80 50 30 85 81 74 69 65 59 58 51 51 44 46 38 41 34 37 30 34 27 31 24

10 78 64 53 45 38 33 29 25 22 20

70 78 71 65 60 55 50 46 43 40 37

70 50 30 75 72 66 61 58 53 51 45 46 40 41 35 37 31 33 27 30 24 28 22

10 70 57 48 41 35 30 26 23 20 18

50 58 51 45 40 35 32 29 26 24 22

50 30 56 48 41 36 31 27 24 22 20 18

10 54 45 38 32 28 24 21 19 17 15

INDOOR CANDELA PLOT 0 0 18 16 14 12 10 9 8 7 7 6

180 165 600

150

120 300 105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75

ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

135

300

96.5% 76 Yes-VDT Intensive Use $3.16 based on 3000 hrs. and $0.08 per KWH

60

600 0 0.0

45 15 30 Horiz 0-180 90.0 45.0 Test Date 9/16/05

PHOTOMETRIC DATA

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

PLK-1T8-RPF-E Plank Architectural Beam 9.75 × 48 1-Lamp with Gloss White Regress Basket and Opal Overlay REL-1P32-SC 0.92 F32T8 2900 33 0º = 90  90º = 90 0º = 1.24  90º = 1.22 Length: 3.67 Width: 0.25 Height: 0.00

AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

1713 1666 1593 1526 1460 1350 1220 1083 892 680 608 538

1713 1653 1547 1493 1424 1329 1197 1055 892 725 608 538

1713 1653 1547 1477 1405 1309 1197 1055 823 589 540 538

1713 1639 1531 1460 1387 1268 1126 916 652 499 473 538

1713 1626 1516 1443 1351 1248 1079 833 583 499 473 538

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 113 183 309 363 812 1204 1883 2324 2687

3.9 6.3 10.6 12.5 28.0 41.5 64.9 80.1 92.7

4.2 6.8 11.5 13.5 30.2 44.8 70.1 86.5 100.0

RCR

Luminaire

Angle

LUMINAIRE DATA Test 14034

RC RW 1 2 3 4 5 6 7 8 9 10

70 83 76 69 63 58 53 49 45 42 39

80 50 30 79 76 69 64 61 55 54 47 48 41 43 36 38 31 34 28 31 25 28 22

10 73 60 50 42 36 31 26 23 20 18

70 73 66 60 55 50 46 43 39 36 34

70 50 30 70 67 61 57 54 48 47 42 42 36 37 32 34 28 30 25 28 22 25 20

10 64 53 44 37 32 27 24 21 18 16

50 51 45 40 35 31 28 25 23 21 19

50 30 49 42 36 31 27 24 21 19 17 15

10 48 40 33 28 24 21 18 16 14 12

INDOOR CANDELA PLOT 0 0 11 9 8 7 6 5 5 4 4 3

180 165 600

135

120 300 105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75

ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

150

300

92.7% 75 Yes-VDT Intensive Use $3.20 based on 3000 hrs. and $0.08 per KWH

60

600 0 0.0

15 30 45 Horiz 0-180 90.0 45.0 Test Date 9/9/05

Page 2/6 Rev. 11/28/16 © 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

BEAMS / PLK CM

PLK CABLE MOUNT 1 , 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution PHOTOMETRIC DATA

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

PLK-2T8-WCB-E Plank Architectural Beam 9.75 × 48 2-Lamp with Gloss White Center Louver and Side Reflectors REL-2P32-SC 0.88 F32T8 2900 63 0º = 90  90º = 90 0º = 1.03  90º = 1.23 Length: 3.67 Width: 0.25 Height: 0.00

AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

8095 6259 5314 4745 4107 3579 3402 3220 3053 2992 3040 3365

8095 6435 5544 5011 4435 3784 3473 3276 3121 3128 3175 3365

8095 6882 6126 5691 5183 4643 4059 3692 3499 3309 3243 3365

8095 7451 6876 6504 6059 5543 4974 4331 3636 3309 3243 3231

8095 7762 7366 7051 6662 6095 5467 4608 3567 3264 3243 3231

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 502 790 1266 1506 1211 1907 3221 4108 5613

8.7 13.6 21.8 26.0 20.9 32.9 55.5 70.8 96.8

8.9 14.1 22.6 26.8 21.6 34.0 57.4 73.2 100.0

RCR

Luminaire

Angle

LUMINAIRE DATA Test 14014

RC RW 1 2 3 4 5 6 7 8 9 10

70 90 82 75 68 63 58 53 49 46 43

80 50 30 86 82 75 70 66 59 59 51 52 45 47 39 42 35 38 31 35 28 32 25

10 79 65 54 46 39 34 30 26 23 20

70 80 73 67 61 56 51 48 44 41 38

70 50 30 77 74 67 63 59 54 53 46 47 41 42 36 38 32 34 28 31 25 29 23

10 71 59 49 42 36 31 27 24 21 19

50 60 53 47 41 37 33 30 27 25 23

50 30 58 49 43 37 33 29 26 23 21 19

10 56 47 39 34 29 25 22 20 17 16

INDOOR CANDELA PLOT 0 0 22 19 16 14 12 11 10 9 8 7

180 165 1100

150

120 550 105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75

ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

135

550

96.8% 78 Yes-VDT Intensive Use $3.08 based on 3000 hrs. and $0.08 per KWH

60

1100 0 0.0

15 30 45 Horiz 0-180 90.0 45.0 Test Date 9/18/07

PHOTOMETRIC DATA

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

PLK-2T8-PERF-WCB-E Plank Architectural Beam 9.75 × 48 2-Lamp with Gloss White Center Louver and Side Reflectors ICN-2M32-MC 0.88 F32T8 2900 62 0º = 90  90º = 90 0º = 1.03  90º = 1.23 Length: 3.67 Width: 0.25 Height: 0.00

AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

7438 5784 4977 4496 3924 3293 3027 2859 2744 2674 2702 3096

7438 5933 5161 4695 4143 3518 3074 2887 2744 2720 2702 2692

7438 6245 5590 5193 4745 4213 3660 3220 3053 2856 2702 2423

7438 6692 6172 5824 5439 4950 4388 3803 3190 2810 2567 2288

7438 7126 6784 6504 6169 5666 5068 4303 3156 2538 2432 2154

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 460 724 1161 1370 1167 1839 3106 3965 5335

7.9 12.5 20.0 23.6 20.1 31.7 53.6 68.4 92.0

8.6 13.6 21.8 25.7 21.9 34.5 58.2 74.3 100.0

RCR

Luminaire

Angle

LUMINAIRE DATA Test 13890

RC RW 1 2 3 4 5 6 7 8 9 10

70 85 78 71 65 60 55 51 47 43 40

80 50 30 81 78 71 66 63 56 56 49 49 42 44 37 40 33 36 29 33 26 30 24

10 75 62 51 43 37 32 28 25 22 19

70 76 69 63 58 53 49 45 42 39 36

70 50 30 73 70 64 59 56 51 50 44 44 38 40 34 36 30 33 27 30 24 27 22

10 67 56 47 40 34 29 26 23 20 18

50 56 50 44 39 35 31 28 26 24 22

50 30 55 47 40 35 31 27 24 22 19 18

10 53 44 37 32 27 24 21 18 16 15

INDOOR CANDELA PLOT 0 0 20 17 15 13 11 10 9 8 7 7

180

165

150

135

1100 120 550 105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75

ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

92.0% 80 Yes-VDT Intensive Use $3.00 based on 3000 hrs. and $0.08 per KWH

60

550

1100 0 0.0

15 30 45 Horiz 0-180 90.0 45.0 Test Date 3/24/05

Page 3/6 Rev. 11/28/16 © 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

BEAMS / PLK CM

PLK CABLE MOUNT 1 , 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution PHOTOMETRIC DATA

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

PLK-2T8-RPF-E Plank Architectural Beam 9.75 × 48 2-Lamp with Gloss White Regress Basket and Opal Overlay REL-2P32-SC 0.88 F32T8 2900 62 0º = 90  90º = 90 0º = 1.24  90º = 1.21 Length: 3.67 Width: 0.25 Height: 0.00

AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

5033 4863 4625 4463 4234 3968 3590 3137 2538 1994 1621 1615

5033 4850 4594 4430 4198 3907 3543 3054 2470 1994 1554 1615

5033 4850 4548 4330 4052 3702 3285 2776 2230 1677 1621 1615

5033 4796 4457 4198 3869 3436 2933 2387 1818 1496 1486 1481

5033 4755 4380 4098 3742 3293 2769 2221 1681 1451 1419 1346

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 333 538 898 1050 1267 2013 3420 4376 5426

5.7 9.3 15.5 18.1 21.8 34.7 59.0 75.5 93.6

6.1 9.9 16.5 19.3 23.4 37.1 63.0 80.7 100.0

RCR

Luminaire

Angle

LUMINAIRE DATA Test 14031

RC RW 1 2 3 4 5 6 7 8 9 10

70 85 78 71 65 59 54 50 46 43 40

80 50 30 81 78 71 66 63 56 55 48 49 42 44 37 39 32 36 29 32 26 29 23

10 75 61 51 43 37 32 27 24 21 19

70 75 68 62 57 52 48 44 41 38 35

70 50 30 72 69 63 59 56 50 49 43 44 38 39 33 35 29 32 26 29 23 26 21

10 67 55 46 39 33 29 25 22 19 17

50 54 48 42 37 33 30 27 24 22 20

50 30 53 45 39 33 29 26 23 20 18 16

10 51 42 36 30 26 23 20 17 15 14

INDOOR CANDELA PLOT 0 0 16 13 11 10 9 8 7 6 5 5

180

165

150

120 600 105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75

ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

135

1200

600

93.6% 77 Yes-VDT Intensive Use $3.12 based on 3000 hrs. and $0.08 per KWH

60

1200 0 0.0

15 30 45 Horiz 0-180 90.0 45.0 Test Date 9/18/07

PHOTOMETRIC DATA

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

PLK-3T8-WCB-E Plank Architectural Beam 9.75 × 48 3-Lamp with Gloss White Center Louver and Side Reflectors REL-3P32-SC 0.88 F32T8 2900 88 0º = 90  90º = 90 0º = 1.02  90º = 1.17 Length: 3.67 Width: 0.25 Height: 0.00

AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

12424 9523 8071 7201 6187 5420 5092 4802 4494 4306 4256 4308

12424 9632 8239 7433 6516 5584 5162 4830 4528 4442 4256 3904

12424 10079 8852 8179 7447 6668 5889 5385 5077 4669 4256 3500

12424 10770 9801 9291 8797 8243 7579 6829 5934 5031 4459 3500

12424 11230 10537 10187 9819 9368 8799 7967 6860 5394 4662 3500

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 752 1173 1871 2224 1518 2517 4463 5794 8018

8.6 13.5 21.5 25.6 17.4 28.9 51.3 66.6 92.2

9.4 14.6 23.3 27.7 18.9 31.4 55.7 72.3 100.0

RCR

Luminaire

Angle

LUMINAIRE DATA Test 14017

RC RW 1 2 3 4 5 6 7 8 9 10

70 86 78 71 65 60 55 51 47 44 41

80 50 30 82 79 72 66 63 57 56 49 50 43 45 38 40 33 36 30 33 27 30 24

10 76 62 52 44 38 32 28 25 22 20

70 77 70 64 58 53 49 45 42 39 37

70 50 30 73 71 64 60 57 51 50 45 45 39 40 34 36 30 33 27 30 24 27 22

10 68 56 47 40 34 30 26 23 20 18

50 57 51 45 40 36 32 29 26 24 22

50 30 56 48 41 36 31 28 25 22 20 18

10 54 45 38 32 28 24 21 19 17 15

INDOOR CANDELA PLOT 0 0 22 19 16 14 12 11 10 9 8 7

180

165

135

120 850 105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75

ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

150

1700

850

92.2% 80 Yes-VDT Normal Use $3.00 based on 3000 hrs. and $0.08 per KWH

60

1700 0 0.0

15 30 45 Horiz 0-180 90.0 45.0 Test Date 8/11/05

Page 4/6 Rev. 11/28/16 © 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

BEAMS / PLK CM

PLK CABLE MOUNT 1 , 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution PHOTOMETRIC DATA

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

PLK-1T5HO-WCB-EP Plank Architectural Beam 9.75 × 48 1-Lamp with Gloss White Center Louver and Opal Overlay ICN2S5490C 1.02 F54T5HO 4450 62 0º = 90  90º = 90 0º = 1.03  90º = 1.25 Length: 3.67 Width: 0.25 Height: 0.00

AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

4540 3509 2971 2671 2318 2045 1924 1832 1749 1677 1757 1750

4540 3603 3124 2837 2519 2168 1994 1888 1818 1813 1757 1615

4540 3888 3492 3252 2975 2679 2370 2165 2024 1904 1824 1615

4540 4240 3967 3750 3504 3129 2651 2249 1989 1904 1757 1481

4540 4430 4242 4048 3778 3334 2745 2221 1887 1813 1757 1481

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 282 446 716 847 1225 1793 2785 3434 4281

6.3 10.0 16.1 19.0 27.5 40.3 62.6 77.2 96.2

6.6 10.4 16.7 19.8 28.6 41.9 65.0 80.2 100.0

RCR

Luminaire

Angle

LUMINAIRE DATA Test 14020

RC RW 1 2 3 4 5 6 7 8 9 10

70 88 80 73 67 61 56 52 48 44 41

80 50 30 84 80 73 68 64 58 57 50 51 43 45 38 41 33 37 30 33 27 30 24

10 77 63 53 44 38 33 28 25 22 20

70 77 70 64 59 54 49 46 42 39 37

70 50 30 74 71 65 60 57 52 51 45 45 39 40 34 36 30 33 27 30 24 27 22

10 69 57 47 40 34 30 26 23 20 18

50 56 49 44 39 35 31 28 25 23 21

50 30 54 46 40 35 30 27 24 21 19 17

10 53 44 37 31 27 23 20 18 16 14

INDOOR CANDELA PLOT 0 0 16 14 12 10 9 8 7 7 6 5

180

165

150

120 400 105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75

ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

135

800

400

96.2% 70 Yes-VDT Intensive Use $3.43 based on 3000 hrs. and $0.08 per KWH

60

800 0 0.0

15 30 45 Horiz 0-180 90.0 45.0 Test Date 8/15/05

PHOTOMETRIC DATA

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

PLK-1T5HO-RPF-EP Plank Architectural Beam 9.75 × 48 1-Lamp with Regress Perforated Basket and Opal Overlay ICN-2S54 1.02 F54T5HO 4450 63 0º = 90  90º = 90 0º = 1.24  90º = 1.21 Length: 3.67 Width: 0.25 Height: 0.00

AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5

2276 2208 2098 2024 1916 1800 1642 1444 1166 952 878 942

2276 2181 2067 1991 1898 1759 1619 1416 1166 997 878 808

2276 2167 2037 1958 1843 1718 1596 1416 1166 907 811 808

2276 2154 2022 1908 1807 1677 1478 1249 960 771 743 673

90.0 2276 2140 1976 1875 1770 1616 1408 1138 858 725 676 673

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 150 242 408 484 1314 1945 3061 3804 4287

3.4 5.4 9.2 10.9 29.5 43.7 68.8 85.5 96.3

3.5 5.6 9.5 11.3 30.7 45.4 71.4 88.7 100.0

RCR

Luminaire

Angle

LUMINAIRE DATA Test 14036

RC RW 1 2 3 4 5 6 7 8 9 10

70 86 78 71 65 60 55 50 46 43 40

80 50 30 82 79 72 66 63 56 56 48 49 42 44 37 39 32 35 28 32 25 29 23

10 75 62 51 43 37 31 27 24 21 18

70 75 68 62 56 52 47 44 40 37 35

70 50 30 72 69 63 58 55 50 49 43 43 37 39 32 35 28 31 25 28 22 26 20

10 66 54 45 38 33 28 24 21 19 16

50 52 46 40 36 32 28 25 23 21 19

50 30 50 43 37 32 28 24 21 19 17 15

10 49 40 34 29 25 21 18 16 14 13

INDOOR CANDELA PLOT 0 0 9 8 7 6 5 4 4 4 3 3

180 165 1000

135

120 500 105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75

ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

150

500

96.3% 69 Yes-VDT Intensive Use $3.48 based on 3000 hrs. and $0.08 per KWH

60

1000 0 0.0

15 30 45 Horiz 0-180 90.0 45.0 Test Date 9/13/05

Page 5/6 Rev. 11/28/16 © 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

BEAMS / PLK CM

PLK CABLE MOUNT 1 , 2, 3-Lamp T5, T5HO, T8, Direct/Indirect Distribution PHOTOMETRIC DATA

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

PLK-2T5HO-WCB-EP Plank Architectural Beam 9.75 × 48 2-Lamp with Gloss White Center Louver and Opal Overlay ICN2S5490C 1.00 F54T5HO 4450 121 0º = 90  90º = 90 0º = 1.02  90º = 1.21 Length: 3.67 Width: 0.25 Height: 0.00

AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

9890 7573 6417 5724 4964 4377 4153 3942 3739 3626 3716 3904

9890 7749 6647 6023 5275 4541 4200 3970 3773 3717 3581 3231

9890 8263 7275 6686 6078 5400 4834 4469 4288 3944 3783 3096

9890 8900 8071 7549 7063 6484 5913 5274 4494 4034 3716 2692

9890 9279 8592 8179 7720 7220 6617 5746 4596 4125 3783 2827

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 608 952 1514 1798 2078 3203 5222 6569 8366

6.8 10.7 17.0 20.2 23.4 36.0 58.7 73.8 94.0

7.3 11.4 18.1 21.5 24.8 38.3 62.4 78.5 100.0

RCR

Luminaire

Angle

LUMINAIRE DATA Test 14021

RC RW 1 2 3 4 5 6 7 8 9 10

70 86 78 72 66 60 55 51 47 44 41

80 50 30 82 79 72 67 63 57 56 49 50 43 45 37 40 33 36 29 33 26 30 24

10 76 62 52 44 37 32 28 25 22 19

70 76 69 63 58 53 49 45 42 39 36

70 50 30 73 70 64 60 56 51 50 44 44 38 40 34 36 30 32 27 30 24 27 21

10 68 56 47 39 34 29 25 22 20 18

50 56 49 43 38 34 31 28 25 23 21

50 30 54 46 40 34 30 27 24 21 19 17

10 52 43 37 31 27 23 20 18 16 14

INDOOR CANDELA PLOT 0 0 17 15 13 11 10 9 8 7 6 6

180

165

150

120 850 105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75

ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

135

1700

850

94.0% 69 Yes-VDT Normal Use $3.48 based on 3000 hrs. and $0.08 per KWH

60

1700 0 0.0

15 30 45 Horiz 0-180 90.0 45.0 Test Date 8/17/05

PHOTOMETRIC DATA

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

PLK-3T5HO-WCB-EP Plank Architectural Beam 9.75 × 48 3-Lamp with Gloss White Center Louver and Opal Overlay ICN-4S5490C-2LS 1.00 F54T5HO 4450 183 0º = 90  90º = 90 0º = 1.02  90º = 1.16 Length: 3.67 Width: 0.25 Height: 0.00

AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

16049 12260 10368 9225 7958 6995 6617 6274 5900 5757 5810 5923

16049 12409 10583 9540 8396 7220 6711 6302 5900 5893 5743 5115

16049 13005 11425 10585 9673 8693 7743 7162 6757 6255 5945 4846

16049 13736 12558 11879 11225 10431 9479 8467 7306 6391 5608 4577

16049 14400 13554 13074 12557 11863 10864 9716 8198 6845 5878 4308

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 968 1510 2405 2861 2725 4341 7284 9259 12120

7.3 11.3 18.0 21.4 20.4 32.5 54.8 69.4 90.8

8.0 12.5 19.8 23.6 22.5 35.8 60.1 76.4 100.0

RCR

Luminaire

Angle

LUMINAIRE DATA Test 14024

RC RW 1 2 3 4 5 6 7 8 9 10

70 84 76 70 64 58 54 50 46 43 40

80 50 30 80 77 70 65 62 55 54 48 48 41 43 36 39 32 35 29 32 26 29 23

10 74 60 50 43 36 31 27 24 21 19

70 74 68 62 56 52 48 44 41 38 35

70 50 30 71 68 62 58 55 50 49 43 43 37 39 33 35 29 32 26 29 23 26 21

10 66 54 45 39 33 29 25 22 19 17

50 55 48 43 38 34 30 27 25 23 21

50 30 53 45 39 34 30 26 23 21 19 17

10 51 43 36 31 26 23 20 18 16 14

INDOOR CANDELA PLOT 0 0 18 16 13 12 10 9 8 7 7 6

180

165

150

135

2600 120 1300 105 90

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

75

ENERGY DATA Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

90.8% 66 Noncompliant $3.64 based on 3000 hrs. and $0.08 per KWH

1300

60

2600 0 0.0

15 30 45 Horiz 0-180 90.0 45.0 Test Date 9/6/05

Page 6/6 Rev. 11/28/16 © 2016 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

BEAMS / PLK CM