Model: HYW-45 T5

Report 11 Downloads 40 Views
Model: HYW-45 T5 INDUSTRIAL RANGE Powered by YANMAR Market: Australia

B10

K3

WATER-COOLED THREE PHASE 50 HZ DIESEL

CE

COMPLIANCE

Generator Ratings SERVICE Power Power Rated Speed Standard Voltage Available Voltages Rated at power factor

kVA kW r.p.m.

PRP(Prime) 41 33

STANDBY 45 36 1.500

V

400

V Cos Phi

230 /400V 0,8

Definitions Standby rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).

General Data Documents

A full set of operation and maintenance manuals and circuit wiring diagrams.

Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Quality Standards

Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) air inlet temp, 100m (328ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869:1998, Class A2.

Warranty

BS4999, BS5000, BSEN60034, BSEN61000, IEC60034

All equipment carries full manufacturer’s warranty. 2000 hours/12 months

HIMOINSA HEADQUARTERS:

Ctra. Murcia - San Javier, Km. 23,6 | 30730 SAN JAVIER (Murcia) Spain Tel.+34 968 19 11 28 Fax +34 968 19 12 17 Fax +34 968 19 04 20 [email protected] www.himoinsa.com

Manufacture facilities: QR Code SPAIN • FRANCE • INDIA • CHINA • USA Subsidiaries: ITALY | PORTUGAL | POLAND | GERMANY I SINGAPORE | UAE | MEXICO | PANAMÁ | ARGENTINA | ANGOLA

Generator Power Pty Ltd

ABN 99 110 686 747 Postal Address: PO Box 664, Padstow NSW 2211 Factory: 6 - 8 Exceller Avenue, Bankstown NSW 2200 Telephone: 9790 6800 Fax: 9790 6400 Email: [email protected] Website: www.generatorpower.com.au

Model: HYW-45 T5 INDUSTRIAL RANGE Powered by YANMAR Market: Australia

Engine Specification

Alternator Specification

PRP

Engine Rated Output

(Kw)

Standby

37,7

Engine Manufacturer

Alternator Alternator Manufacturer

41,8 YANMAR

Engine Model Engine Type Injection Type

4TNV98T Diesel 4 strokes-cycle Direct Turbocharged

Aspiration Type Cylinders Arrangement (mm) Bore and Stroke Displacement

Compression Ratio

18,1

Insulation Type AVR Model Winding Pitch Voltage Regulation NL-FL IP Rating Telephone Interference

Fuel Consumption StandBy (L/hr) Fuel Consumption 100% PRP (L/hr)

11,3 10,25 7,78 5,49

Excitation System Bearing Coupling Coating (Standard)

3,319 API grade CF, CF4 CI-4

Fuel Consumption 75 % PRP (L/hr) Fuel Consumption 50 % PRP (L/hr) Lube Oil Consumption Full Load (g/kwh) Total Oil Capacity

(L)

Total Coolant Capacity Governor Type

Star-serie S-3 11"1/2 12 H class AS480 2/3 _ +1% A.V.R. (Electronic) IP23 THF