Harvey-Cleary Builders 8107 Springdale Road, Suite 105 Austin, TX 78752 (512) 928-9300 / (512) 928-9331 fax
7 Hamilton Landing, Ste. 200, Novato, CA
✔
APPROVED
NO EXCEPTIONS TAKEN
APPROVED AS NOTED
NOT SUBJECT TO REVIEW
REVISE & RESUBMIT
SUBMITTAL TRANSMITTAL FORM
REJECTED
Project Name : Hilton Lobby and Restaurant Renovation 04-04108 Project No.
TO:
Andy Carey - HCB
DATE:
6/29/2016
TO:
Gordon Bingaman - AA
DATE:
6/29/2016
TO:
Justin Gesch - AA
DATE:
6/29/2016
CC:
Dave Maynard - EDG
DATE:
6/29/2016
CC:
James Harvey - HCB
DATE:
6/29/2016
CC:
David Pryor - HCB
DATE:
6/29/2016
CC:
Steve Frintz - HCB
DATE:
6/29/2016
CC:
Gene del Monte - HH
DATE:
6/29/2016
CC:
John Culp - HH
DATE:
6/29/2016
RETURN DUE DATE: TO: Harvey-Cleary Builders -
✔
SEE ADDITIONAL COMMENTS BY:
RICCA ___________________________________
CORRECTIONS OR COMMENTS MADE TO THE SUBMITTAL DURING THIS REVIEW DO NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS. THIS CHECK IS ONLY FOR REVIEW OF THE GENERAL COMPLIANCE WITH THE DESIGN CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE WITH THE INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR: CONFIRMING AND CORRECTING ALL QUANTITIES AND DIMENSIONS; SELECTING FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION; COORDINATING HIS OR HER WORK WITH THAT OF ALL OTHER TRADES AND PERFORMING ALL WORK IN A SAFE AND SATISFACTORY MANNER.
Submittal Number
114000.02R1
Dave Maynard 16-0705 REVIEWED BY: _________________________________ DATE: ______________
1. REVIEWED BY EDG FOR AESTHETIC DESIGN INTENT ONLY - ALL LIFE SAFETY, CODE COMPLIANCE, OPERATIONAL AND INFRASTRUCTURAL REVIEWS BY OTHERS. 2. VERIFY ALL DIMENSIONS IN FIELD. 3. EDG NOTES IN GREEN.
7/5/2016
DATE:
TO:
DATE: X
1
1
4 LIST OF ATTACHED SUBMITTAL ONE TRADE SUB ONLY DRAWING NOS.
ITEMS
11 40 00
1
DESCRIPTION Kitchen Equipment Rough-In and Blocking Drawings
SEE COMMENTS BELOW
Mission Restaurant Supply
REVISE / RESUBMIT
SUBCONTRACTOR OR SUPPLIER:
REVIEWED
Copies
SUBMITTAL RETURNED TO SUB
REVIEW RETURNED TO HCB 3
06/29/16
NOTE MARKINGS
2
7/6/2016
114000.02R1 NO EXCEPTIONS TAKEN
1
FORWARDED FOR REVIEW
SUBMITTED FOR APPROVAL
CONTRACTOR'S SUBMITTAL STAMP:
X
COMMENTS: Expedited review request is so that we can get an approved set sent to our MEP contractors for rough-in purposes.
** Please keep this form with the submittal throughout the entire process. SENT BY: TITLE:
James "Andy" Carey Assistant Project Manager
DATE:
6/29/2016
cc:
File Field
JIM DITRAPANI
06-30-2016
page 1 of 1
S T RUCT URA L ,
Arizona
ME P ,
California
CI V I L
E NG I NE E RI NG
Colorado
Florida
&
Texas
CO NS T RUCT I O N
Lebanon
S E RV I CE S
Saudi Arabia
U.A.E.
SHOP DRAWING SUBMITTAL REVIEW COMMENTS
DATE: 2016-06-30
PROJECT NAME: Hilton Lobby and Restaurant Renovation
TTG PROJ. NO: 1540262
OWNER: Hilton
CLIENT: Antenora Architects
ITEM(S) SUBMITTED: Kitchen Equipment Shop Drawings
SUBMITTAL NO: 14000.02R1
TITLE: Kitchen Equipment Rough-In and Blocking Drawings SUBMITTED BY: Harvey-Cleary Builders CODE
CODE DESCRIPTION
ACTION REQUIRED
A
NO EXCEPTIONS TAKEN.
NONE-FINAL REVIEW.
B
GENERAL COMPLIANCE WITH CONTRACT DOCUMENTS WITH EXCEPTIONS AND COMMENTS AS NOTED.
NONE-FINAL REVIEW IF NOTED COMMENTS ARE ACCEPTED - OTHERWISE RESUBMIT (SEE NOTE 1, 2, & 3 BELOW).
C
REJECTED - NOT IN COMPLIANCE WITH CONTRACT DOCUMENTS - EXCEPTION NOTED.
RESUBMIT SPECIFICATION SECTION IN ITS ENTIRETY.
D
ITEMS NOT INCLUDED IN SUBMITTAL.
SUBMIT SPECIFICATION SECTION IN ITS ENTIRETY.
E
OTHER.
MAKE CORRECTIONS AND RESUBMIT.
NOTE 1: FINAL SUBMITTAL DOCUMENTS WHICH BECOME A PART OF THE OWNER’S OPERATING AND MAINTENANCE MANUAL SHALL BE CORRECTED TO INCORPORATE ALL OF THE ENGINEER’S COMMENTS. NOTE 2: REVIEW IS FOR GENERAL COMPLIANCE WITH BASIC CONCEPT ONLY AND DOES NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITIES IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR PROPER MATCHING OF SPACES AND EQUIPMENT AT THE PROJECT SITE, FOR INFORMATION THAT PERTAINS SOLELY TO THE FABRICATION PROCESS OR TO TECHNIQUES OF CONSTRUCTION, FOR COORDINATION OF THE WORK OF ALL TRADES AND FOR COMPLYING WITH THE REQUIREMENTS OF ALL LOCAL TRADES AND THEIR ENFORCING AUTHORITIES. NOTE 3: WHEN THE CONTRACT DOCUMENTS CALL FOR MATERIALS OR CONSTRUCTION OF BETTER QUALITY OR LARGER SIZE THAN REQUIRED BY CODES AND REGULATIONS, PROVIDE THE QUALITY AND SIZE REQUIRED BY THE CONTRACT DOCUMENTS.
12710 Research Blvd., Suite 355, Austin, Texas 78759
(512) 416-1654
www.ttgcorp.com
ITEM
SPEC. SECTION
1
22 00 00
[Item P-118] Refer to plumbing drawing for PCU drain pipe routing. Drain shall connect to grease waste piping.
B
7
23 00 00
[Hood] Make sure to provide both hoods with modulating motorized damper furnished by Gaylord Industry. Dampers shall be connected to air vantage system.
B
8
26 00 00
All of the kitchen equipment electrical schedule shall be verify by the kitchen designer.
B
COMMENTS
CODE
REVIEWER: Arash Pasgar, Tim Bulgrin, and Aaron Garcia
DATE: 06-30-2016
PROJECT MANAGER: Paul Reyes P.E.
DATE: 06-30-2016
KEC TO VERIFY ALL DIMENSIONS
UP
FAX 972-241-3575 972-230-5000
13970 N. Stemmons Freeway Dallas, TX 75234
RESTAURANT SUPPLY
MISSION
NOTE: ITEMS 22 - 27 TO BE PROVIDED AND INSTALLED BY LIQUID LOGISTICS, CONTACT: KRIS BYRD, 512-987-8096. COORDINATE DIVISION OF RESPONSIBILITIES AND NECESSARY SERVICES. VERIFY WITH OWNER.
UP
HILTON AUSTIN
Food Service Equipment Plan
Schindler Schindler
HILTON AUSTIN CONVENTION CENTER 500 E. 4TH STREET AUSTIN, TX 78701
DN
HILTON AUSTIN LEVEL 2
1
EQUIPMENT LAYOUT PLAN SCALE:
1/4" = 1'-0"
6/10/2016
K-1
P-01
(9)
UP
UP B
CW
COLD WATER SUPPLY
FS
FLOOR SINK (WITH GRATE)
SU
STUB-UP
SCW
SOFT COLD WATER SUPPLY
FS
FLOOR SINK
AFF
ABOVE FINISHED FLOOR
HW
HOT WATER SUPPLY (140°)
G
GAS
FFF
FLUSH W/FINISHED FLOOR
W
WASTE DRAIN
G
GAS CONNECTION
BFF
BELOW FINISHED FLOOR
HD
HUB DRAIN
SS
STEAM SUPPLY
BTC
BRANCH TO CONNECTION
FD
FLOOR DRAIN
CR
CONDENSATE RETURN
FFD
FUNNEL FLOOR DRAIN
PVC
6" PVC CONDUIT
FAX 972-241-3575 972-230-5000
PLUMBING SYMBOLS AND ABBREVIATIONS
13970 N. Stemmons Freeway Dallas, TX 75234
ITEM/#
RESTAURANT SUPPLY
QTY.
MISSION
PLUMBING COORDINATION
B
B B
F
A
B
Schindler
B C
D
E
F
G
H
I
J
K
L
HILTON AUSTIN CONVENTION CENTER 500 E. 4TH STREET AUSTIN, TX 78701
B
HILTON AUSTIN
Schindler
F
Food Service Special Conditions Plan
DN
L
HILTON AUSTIN LEVEL 2
2
EQUIPMENT SPECIAL CONSITIONS PLAN SCALE:
1/4" = 1'-0"
6/10/2016
K-2
UP
DN
FAX 972-241-3575 972-230-5000
SCALE: NOT TO SCALE
13970 N. Stemmons Freeway Dallas, TX 75234
-
RESTAURANT SUPPLY
INDIRECT WASTE LINE
MISSION
UP
-
PLEASE REFERENCE GAYLORD SHOP DRAWINGS - AC
GENERAL PLUMBING AND MECHANICAL NOTES
GENERAL PLUMBING AND MECHANICAL NOTES
3
SCALE:
1/4" = 1'-0"
LEVEL 2
PLUMBING SYMBOLS AND ABBREVIATIONS CW
COLD WATER SUPPLY
FS
FLOOR SINK (WITH GRATE)
SU
STUB-UP
SCW
SOFT COLD WATER SUPPLY
FS
FLOOR SINK
AFF
ABOVE FINISHED FLOOR
HW
HOT WATER SUPPLY (140°)
G
GAS
FFF
FLUSH W/FINISHED FLOOR
W
WASTE DRAIN
G
GAS CONNECTION
BFF
BELOW FINISHED FLOOR
HD
HUB DRAIN
SS
STEAM SUPPLY
BTC
BRANCH TO CONNECTION
FD
FLOOR DRAIN
CR
CONDENSATE RETURN
FFD
FUNNEL FLOOR DRAIN
PVC
6" PVC CONDUIT
HILTON AUSTIN CONVENTION CENTER 500 E. 4TH STREET AUSTIN, TX 78701
HILTON AUSTIN
GENERAL PLUMBING AND MECHANICAL NOTES
EQUIPMENT LAYOUT PLAN PLUMBING CONNECTIONS PLAN
HILTON AUSTIN
Food Service Plumbing Connections Plan
Schindler Schindler
PLUMBING COORDINATION
6/10/2016
K-3
GENERAL ELECTRICAL NOTES
POS IN THIS LOCATION IS INTEGRATED INTO MILLWORK. OUTLETS TO BE APPROX. 36" AFF - COORDINATE WITH MILLWORK
There will be a conflict with electrical stub up, floor sink and trash can. KEC to coordinate and locate all correctly.
EC
UP
FAX 972-241-3575
ELEC PANELS NOW FACE THE RESTAURANT-AA
972-230-5000
NOT TO SCALE
13970 N. Stemmons Freeway Dallas, TX 75234
-
EX. HOOD FIRE SYSTEM REMOTE PULL STATION RECESSED J-BOX
RESTAURANT SUPPLY
DETAIL
MISSION
-
UP COORDINATE LOCATION OF PULL STATION WITH LIGHTING CONTROLS AND ELECTRICAL PANELS, ETC.
AGREED BY EDG, FOR AESTHETIC INTENT ONLY
EC
ELECTRICAL SYMBOLS AND ABBREVIATIONS Schindler
HILTON AUSTIN CONVENTION CENTER 500 E. 4TH STREET AUSTIN, TX 78701
V.I.F.
HILTON AUSTIN
Schindler
EC
Food Service Electrical Connections Plan
COORD NEW PULL STATION LOCATION ON BACK OR SIDE OF COLUMN - AA
DN
HILTON AUSTIN LEVEL 2
ELECTRICAL GENERAL NOTES
4
EQUIPMENT LAYOUT PLAN ELECTRICIAL CONNECTIONS PLAN
ALL DIMENSIONS ARE FROM COLUMN CENTER LINES, FINISHED FACE OF WALLS AND/OR FLOORS TO CENTERS OF BOXES OR CONDUIT ALL DIMENSIONS UP TO 4'-0" ARE SHOWN IN INCHES. ROUGH-INS SHOWN ARE FOR EQUIPMENT TO BE FURNISHED. SEE ARCHITECTURAL/ELECTRICAL DRAWINGS FOR ALL OTHER REQUIREMENTS.
SCALE:
WILL NOT BE RESPONSIBLE TO FURNISH ELECTRICAL APPURTENANCES SUCH AS LINE OR DISCONNECT SWITCHES, SAFETY CUTOUTS, CONTROL PANELS, FUSE BOXES, FITTINGS, CONDUIT, OR WIRING OTHER THAN THOSE FURNISHED AS A STANDARD PART OF THE EQUIPMENT BY THE MANUFACTURER
1/4" = 1'-0"
ALL WORK TO BE PERFORMED IN FULL ACCORDANCE WITH ALL APPLICABLE CODES RELATING TO ROUGH-INS, HOOK-UP, AND INSTALLATION OF EQUIPMENT.
6/10/2016
K-4
Schindler
5 SCALE: Schindler
HILTON AUSTIN CONVENTION CENTER 500 E. 4TH STREET AUSTIN, TX 78701
HILTON AUSTIN
Food Service Ventilation Connections Plan
UP UP
DN
HILTON AUSTIN
LEVEL 2
EQUIPMENT LAYOUT PLAN VENTILATION CONNECTIONS PLAN
1/4" = 1'-0"
6/10/2016
K-5
972-230-5000
FAX 972-241-3575
13970 N. Stemmons Freeway Dallas, TX 75234
RESTAURANT SUPPLY
MISSION
FAX 972-241-3575 972-230-5000
13970 N. Stemmons Freeway Dallas, TX 75234
RESTAURANT SUPPLY
MISSION NOTE: ITEMS 122 - 128 TO BE PROVIDED AND INSTALLED BY LIQUID LOGISTICS, CONTACT: KRIS BYRD, 512-987-8096. COORDINATE DIVISION OF RESPONSIBILITIES AND NECESSARY SERVICES. VERIFY WITH OWNER.
HILTON AUSTIN CONVENTION CENTER 500 E. 4TH STREET AUSTIN, TX 78701
1/4" = 1'-0"
HILTON AUSTIN
SCALE:
Food Service Equipment Plan
6
EQUIPMENT LAYOUT PLAN
HILTON AUSTIN LEVEL 1
6/10/2016
K-6
B
1/4" = 1'-0"
(1)
PLUMBING SYMBOLS AND ABBREVIATIONS CW
COLD WATER SUPPLY
FS
FLOOR SINK (WITH GRATE)
SU
STUB-UP
SCW
SOFT COLD WATER SUPPLY
FS
FLOOR SINK
AFF
ABOVE FINISHED FLOOR
HW
HOT WATER SUPPLY (140°)
G
GAS DROP
FFF
FLUSH W/FINISHED FLOOR
W
WASTE DRAIN
G
GAS CONNECTION
BFF
BELOW FINISHED FLOOR
HD
HUB DRAIN
SS
STEAM SUPPLY
BTC
BRANCH TO CONNECTION
FD
FLOOR DRAIN
CR
CONDENSATE RETURN
FFD
FUNNEL FLOOR DRAIN
PVC
6" PVC CONDUIT
A
B C
D
E
F
G
H
I
J
FAX 972-241-3575 972-230-5000
ITEM/#
P-01
K
HILTON AUSTIN CONVENTION CENTER 500 E. 4TH STREET AUSTIN, TX 78701
QTY.
HILTON AUSTIN
SCALE:
Food Service Special Conditions Plan
7
EQUIPMENT SPECIAL CONDITIONS PLAN
13970 N. Stemmons Freeway Dallas, TX 75234
B
RESTAURANT SUPPLY
MISSION
H
HILTON AUSTIN LEVEL 1
PLUMBING COORDINATION
6/10/2016
K-7
FAX 972-241-3575 972-230-5000
13970 N. Stemmons Freeway Dallas, TX 75234
RESTAURANT SUPPLY
VERIFY WITH OWNER. BELIEVE THESE ARE AIR COOLED NOT WATER COOLED
GENERAL PLUMBING AND MECHANICAL NOTES
-
INDIRECT WASTE LINE
-
SCALE: NOT TO SCALE
PLUMBING / MECHANICAL GENERAL NOTES KEC WILL FIELD VERIFY THAT TABLE/COUNTER LEGS DO NOT LAND ON FLOOR SINKS OR DRAINS MANIFOLD SINK DRAINS WITH AIR GAP CONNECTION TO FLOOR SINK EXTEND SINK DRAIN WITH AIR GAP CONNECTION TO FLOOR SINK
PLUMBING SYMBOLS AND ABBREVIATIONS
MANIFOLD TO EQUIPMENT CONNECTIONS WITH INDIVIDUAL GAS SHUT OFF VALVES INSTALL AUTOMATIC GAS SHUT-OFF VALVES AT CEILING FURNISHED BY KEC FOR EXHAUST HOOD FIRE SUPPRESSION SYSTEM
CW
COLD WATER SUPPLY
FS
FLOOR SINK (WITH GRATE)
SU
STUB-UP
ALL DIMENSIONS ARE FROM COLUMN CENTER LINES, FINISHED FACE OF WALLS AND/OR FLOORS TO CENTERS OF DRAINS OR PIPING
SCW
SOFT COLD WATER SUPPLY
FS
FLOOR SINK
AFF
ABOVE FINISHED FLOOR
ROUGH-INS SHOWN ARE FOR EQUIPMENT TO BE FURNISHED BY THE KITCHEN EQUIPMENT CONTRACTOR. SEE ARCHITECEURAL/MECHANICAL DRAWINGS FOR ALL OTHER REQUIREMENTS.
HW
HOT WATER SUPPLY (140°)
G
GAS DROP
FFF
FLUSH W/FINISHED FLOOR
W
WASTE DRAIN
G
GAS CONNECTION
BFF
BELOW FINISHED FLOOR
HD
HUB DRAIN
SS
STEAM SUPPLY
BTC
BRANCH TO CONNECTION
THE KITCHEN EQUIPMENT CONTRACTOR WILL NOT BE RESPONSIBLE FOR FURNISHING ACCESSORIES SUCH AS TEES, MIXING VALVES, ELBOWS, SHUT-OFF VALVES, FITTINGS, PIPING, EXHAUST OR SUPPLY AIR DUCTS, OR DUCT FIRE WRAP OTHER THAN THOSE FURNISHED AS A STANDARD PART OF THE EQUIPMENT BY THE MANUFACTURER.
FD
FLOOR DRAIN
CR
CONDENSATE RETURN
ALL WORK TO BE PERFORMED IN FULL ACCORDANCE WITH ALL APPLICABLE CODES RELATING, TO ROUGH-INS, HOOK-UP, AND INSTALLATION OF EQUIPMENT.
FFD
FUNNEL FLOOR DRAIN
PVC
6" PVC CONDUIT
FLUSH OUT ALL PIPING AND DRAINAGE SYSTEMS PRIOR TO CONNECTION OF FOODSERVICE EQUIPMENT.
HILTON AUSTIN CONVENTION CENTER 500 E. 4TH STREET AUSTIN, TX 78701
SEE NOTE ON K-6.
MISSION
PLUMBING COORDINATION
1/4" = 1'-0"
HILTON AUSTIN
SCALE:
Food Service Plumbing Connections Plan
8
EQUIPMENT LAYOUT PLAN PLUMBING CONNECTIONS PLAN
HILTON AUSTIN LEVEL 1
PLUMBER TO SET GAS VALVES, FURNISHED BY KITCHEN EQUIPMENT SUPPLIER, IN THE GAS LINE AS PART OF THE FUEL SHUT OFFS FOR THE FIRE SUPPRESSION SYSTEM PLUMBER TO MAKE FINAL CONNECTION FROM THE MAIN GAS LINE TO EACH PIECE OF EQUIPMENT WITH FLEXIBLE GAS DISCONNECT HOSE PROVIDED BY KITCHEN EQUIPMENT SUPPLIER
6/10/2016
K-8
ELECTRICAL SYMBOLS AND ABBREVIATIONS
13970 N. Stemmons Freeway Dallas, TX 75234
HILTON AUSTIN LEVEL 1
ELECTRICAL GENERAL NOTES ALL DIMENSIONS ARE FROM COLUMN CENTER LINES, FINISHED FACE OF WALLS AND/OR FLOORS TO CENTERS OF BOXES OR CONDUIT ALL DIMENSIONS UP TO 4'-0" ARE SHOWN IN INCHES. ROUGH-INS SHOWN ARE FOR EQUIPMENT TO BE FURNISHED. SEE ARCHITECTURAL/ELECTRICAL DRAWINGS FOR ALL OTHER REQUIREMENTS. WILL NOT BE RESPONSIBLE TO FURNISH ELECTRICAL APPURTENANCES SUCH AS LINE OR DISCONNECT SWITCHES, SAFETY CUTOUTS, CONTROL PANELS, FUSE BOXES, FITTINGS, CONDUIT, OR WIRING OTHER THAN THOSE FURNISHED AS A STANDARD PART OF THE EQUIPMENT BY THE MANUFACTURER ALL WORK TO BE PERFORMED IN FULL ACCORDANCE WITH ALL APPLICABLE CODES RELATING TO ROUGH-INS, HOOK-UP, AND INSTALLATION OF EQUIPMENT.
6/10/2016
K-9
972-230-5000
FAX 972-241-3575
RESTAURANT SUPPLY
NEEDS TO BE VERIFIED, BY WHO? - AC
HILTON AUSTIN CONVENTION CENTER 500 E. 4TH STREET AUSTIN, TX 78701
GENERAL ELECTRICAL NOTES
MISSION
1/4" = 1'-0"
ASK OWNER. WHAT ARE THEY GETTING FROM THEIR VENDORS.
HILTON AUSTIN
SCALE:
SEE NOTE ON K-6.
Food Service Electrical Connections Plan
9
EQUIPMENT LAYOUT PLAN ELECTRICAL CONNECTIONS PLAN