Photometric Test Report AWS

Report 0 Downloads 49 Views
REPORT

FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 17025:2005.

25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 Project No. G101607677

Date: April 29, 2014

REPORT NO. 101607677LAX-006 TEST OF ONE DYNAMIC WHITE LED PAR WW MODEL NO. OPTI TRI WHITE II

RENDERED TO ELATION PROFESSIONAL 6122 S. EASTERN AVENUE COMMERCE, CA, 90040

TEST:

Electrical and Photometric tests as required to the IESNA test standard.

STATEMENT OF LIMITATION:

This report must not be used by the client to claim product certification, approval, or endorsement by A2LA, NIST, or any agency of the federal government.

AUTHORIZATION:

The testing performed was authorized by signed quote number 500519256.

STANDARDS USED:

The following American National Standards or Illuminating Engineering Society of North America Test Guides were used in part or totally to test each specimen:

IESNA LM-79 - 2008: Electrical and Photometric Measurements of Solid State Lighting

DESCRIPTION OF SAMPLE:

The client submitted one prototype sample of model number Opti Tri White II. The sample was received by Intertek on April 25, 2014, in undamaged condition and one sample was tested as received. The sample designation was LAN1404250928-001.

DATES OF TESTS:

April 28, 2014 through April 29, 2014.

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

SUMMARY Model No.: Description:

Opti Tri White II Dynamic White LED PAR WW

Criteria Total Lumen Output (Lumens) Total Power (W) Luminaire Efficacy (LPW)

Sphere 2494 67.89 36.74

Criteria Power Factor Current ATHD % Correlated Color Temperature (CCT - K) Color Rendering Index (CRI - Ra) Color Rendering Index (CRI - R9) DUV Chromaticity Coordinate (x) Chromaticity Coordinate (y) Chromaticity Coordinate (u') Chromaticity Coordinate (v')

Result Goniometer 2497 66.78 37.39

Result 0.976 15.13 3230 82.0 5.4 0.000 0.421 0.398 0.243 0.517

EQUIPMENT LIST

Equipment Used LabSphere Power Supply LapSphere 3M Integrating Sphere LabSphere Spectrometer California Instruments Power Supply Yokogawa Power Meter Extech Instruments Stop Watch Omega Environmental Monitor LSI High Speed Mirror Goniometer Elgar Power Supply Yokogawa Power Analyzer Omega Environmental Monitor Tape Measure Stopwatch

Report No. 101607677LAX-006

Model Number LPS-100-0833 CA-11821-LRT CDS-3020 CSW5550 WT333 N/A N/A 6440T CW1251 WT210 iBTHX-W 33-428 365510

2 of 7

Control Number 000832 000830 000834 001338 001319 001380 000886 000943 000944 000945 000886 000684 001380

Last Date Calibrated 05/23/13 VBU VBU N/A 05/10/13 09/05/13 09/10/13 VBU VBU 11/14/13 09/09/13 12/09/13 11/05/13

Calibration Due Date 05/23/14 VBU VBU N/A 05/10/14 09/05/14 09/10/14 VBU VBU 11/14/14 09/09/14 12/09/14 11/05/14

Date: April 29, 2014

TEST METHODS Seasoning in Sample Orientation – LED Products No seasoning was performed in accordance with IESNA LM-79. Photometric and Electrical Measurements – Integrating Sphere Method A Labsphere CDS 3020 Spectrometer and Three Meter Sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Yokogawa Power Analyzer. The calibration of the sphere spectrometer system is traceable to the National Institute of Standards and Technology. Photometric and Electrical Measurements – Distribution Method A LSI Type C High Speed Model 6440 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Yokogawa Power Analyzer. Some graphics were created with Photometrics Plus software.

Report No. 101607677LAX-006

3 of 7

Date: April 29, 2014

RESULTS OF TEST Photometric and Electrical Measurements at Ambient Temperature (25°C +/- 1°C) - Integrating Sphere Method

Intertek Sample No. LAN1404250928-001

Correlated Color Temperature (K)

3230

CRI -Ra 82.0

Input Input Voltage Current {Vac} (mA) 120.7 579.3

Base Orientation UP

CRI -R9 5.4

DUV 0.000

CIE 31’ Chromaticity Coordinate (x) 0.421

Input Power (Watts) 67.89

Input Current Power ATHD Factor (%) 0.976 15.13

CIE 31’ Chromaticity Coordinate (y) 0.398

Luminous Flux (Lumens) 2494

CIE 76’ Chromaticity Coordinate (u’) 0.243

Lumen Efficacy (LPW) 36.74

CIE 76’ Chromaticity Coordinate (v’) 0.517

Spectral Distribution over Visible Wavelengths nm 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435

mW/nm -0.029 0.018 -0.051 -0.056 -0.063 -0.056 -0.047 -0.027 -0.028 -0.016 0.011 0.032 0.124 0.319 0.681 1.347 2.461 4.342

nm 440 445 450 455 460 465 470 475 480 485 490 495 500 505 510 515 520 525

mW/nm 7.594 13.040 19.540 21.680 17.990 14.350 12.330 10.520 9.617 9.795 10.500 11.580 12.810 14.030 15.080 16.040 16.950 17.770

nm 530 535 540 545 550 555 560 565 570 575 580 585 590 595 600 605 610 615

mW/nm 18.720 19.620 20.700 21.840 23.060 24.410 25.890 27.450 29.070 30.630 32.120 33.360 34.210 34.670 34.950 34.780 34.150 33.090

nm 620 625 630 635 640 645 650 655 660 665 670 675 680 685 690 695 700 705

mW/nm 31.610 29.930 28.020 25.990 23.910 21.710 19.650 17.640 15.750 13.940 12.290 10.770 9.401 8.184 7.060 6.099 5.264 4.557

nm 710 715 720 725 730 735 740 745 750 755 760 765 770 775 780

mW/nm 3.924 3.377 2.910 2.481 2.117 1.812 1.547 1.323 1.141 0.978 0.851 0.730 0.615 0.528 0.454

Spectral Data Over Visible Wavelengths

40.000 35.000

(mW/nm)

30.000 25.000 20.000 15.000 10.000 5.000 0.000 350

400

450

500

550

600

650

700

750

800

Nanometers

Report No. 101607677LAX-006

4 of 7

Date: April 29, 2014

RESULTS OF TEST (cont'd) Photometric and Electrical Measurements at Ambient Temperature (25°C +/- 1°C) – Distribution Method

Intertek Sample No. LAN1404250928-001

Base Orientation UP

Input Input Voltage Current {Vac} (mA) 120.0 570.4

Input Power (Watts) 66.78

Input Absolute Lumen Efficacy Power Luminous Flux (Lumens Per Factor (Lumens) Watt) 0.976 2497 37.39

Intensity (Candlepower) Summary at 25°C - Candelas Maximum Candela Value: Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

0 23023 20036 8635 2463 701 330 211 122 74 41 24 22 19 10 12 3 0 0 12

22.5 23027 20214 8866 2529 693 319 198 132 74 45 38 24 15 22 3 0 2 17 8

23083 45 23007 20259 8938 2626 695 325 197 119 70 38 35 17 17 1 0 16 0 2 5

Report No. 101607677LAX-006

67.5 23083 20420 9150 2685 742 337 205 118 76 49 37 11 9 12 6 5 2 0 6

90 23037 20546 9273 2776 787 357 213 130 74 44 44 29 16 7 6 1 0 8 0

5 of 7

Date: April 29, 2014

RESULTS OF TEST (cont'd) Illumination Plots Mounting Height: 10 ft. Illuminance - Cone of Light

Isoillumination Plot

Zonal Lumens and Percentages at 25°C

Zonal Lumen Summary and Percentages at 25°C Zone Lumens 0-30 2348 0-40 2425 0-60 2482 60-90 14.6 0-90 2496 90-180 0.5 0-180 2497

Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100

% Luminaire 94.0 97.1 99.4 0.6 100.0 0.0 100.0

Report No. 101607677LAX-006

6 of 7

Lumens 1429 756.4 162.6 77.0 36.6 19.9 8.2 4.2 2.2 0.5

% Luminaire 57.2 30.3 6.5 3.1 1.5 0.8 0.3 0.2 0.1 0.0

Date: April 29, 2014

PICTURE (not to scale) X

CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report.

In Charge Of Tests:

Report Reviewed By:

Erik Linares Technician Lighting Division

Kenda Branch Engineer Lighting Division

Attachment: None

Report No. 101607677LAX-006

7 of 7

Date: April 29, 2014