Photometric Test Report

Report 4 Downloads 71 Views
REPORT

FOR THE SCOPE OF ACCREDITATION UNDER A2LA TO ISO/IEC 17025:2005.

25800 COMMERCENTRE DRIVE, LAKE FOREST, CA 92630 Project No. G101607677

Date: April 29, 2014

REPORT NO. 101607677LAX-001 TEST OF ONE DYNAMIC WHITE LED PAR FULL ON MODEL NO. OPTI TRI WHITE II

RENDERED TO ELATION PROFESSIONAL 6122 S. EASTERN AVENUE COMMERCE, CA, 90040

TEST:

Electrical and Photometric tests as required to the IESNA test standard.

STATEMENT OF LIMITATION:

This report must not be used by the client to claim product certification, approval, or endorsement by A2LA, NIST, or any agency of the federal government.

AUTHORIZATION:

The testing performed was authorized by signed quote number 500519256.

STANDARDS USED:

The following American National Standards or Illuminating Engineering Society of North America Test Guides were used in part or totally to test each specimen:

IESNA LM-79 - 2008: Electrical and Photometric Measurements of Solid State Lighting

DESCRIPTION OF SAMPLE:

The client submitted one prototype sample of model number Opti Tri White II . The sample was received by Intertek on April 25, 2014, in undamaged condition and one sample was tested as received. The sample designation was LAN1404250928-001.

DATES OF TESTS:

April 28, 2014 through April 29, 2014.

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

SUMMARY Model No.: Description:

Opti Tri White II Dynamic White LED PAR Full On

Criteria Total Lumen Output (Lumens) Total Power (W) Luminaire Efficacy (LPW)

Sphere 3680 103.6 35.52

Criteria Power Factor Current ATHD % Correlated Color Temperature (CCT - K) Color Rendering Index (CRI - Ra) Color Rendering Index (CRI - R9) DUV Chromaticity Coordinate (x) Chromaticity Coordinate (y) Chromaticity Coordinate (u') Chromaticity Coordinate (v')

Result Goniometer 3712 102.5 36.21

Result 0.987 11.41 3834 81.9 -8.6 0.008 0.382 0.362 0.232 0.495

EQUIPMENT LIST

Equipment Used LabSphere Power Supply LapSphere 3M Integrating Sphere LabSphere Spectrometer California Instruments Power Supply Yokogawa Power Meter Extech Instruments Stop Watch Omega Environmental Monitor LSI High Speed Mirror Goniometer Elgar Power Supply Yokogawa Power Analyzer Omega Environmental Monitor Tape Measure Stopwatch

Report No. 101607677LAX-001

Model Number LPS-100-0833 CA-11821-LRT CDS-3020 CSW5550 WT333 N/A N/A 6440T CW1251 WT210 iBTHX-W 33-428 365510

2 of 7

Control Number 000832 000830 000834 001338 001319 001380 000886 000943 000944 000945 000886 000684 001380

Last Date Calibrated 05/23/13 VBU VBU N/A 05/10/13 09/05/13 09/10/13 VBU VBU 11/14/13 09/09/13 12/09/13 11/05/13

Calibration Due Date 05/23/14 VBU VBU N/A 05/10/14 09/05/14 09/10/14 VBU VBU 11/14/14 09/09/14 12/09/14 11/05/14

Date: April 29, 2014

TEST METHODS Seasoning in Sample Orientation – LED Products No seasoning was performed in accordance with IESNA LM-79. Photometric and Electrical Measurements – Integrating Sphere Method A Labsphere CDS 3020 Spectrometer and Three Meter Sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Yokogawa Power Analyzer. The calibration of the sphere spectrometer system is traceable to the National Institute of Standards and Technology. Photometric and Electrical Measurements – Distribution Method A LSI Type C High Speed Model 6440 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Yokogawa Power Analyzer. Some graphics were created with Photometrics Plus software.

Report No. 101607677LAX-001

3 of 7

Date: April 29, 2014

RESULTS OF TEST Photometric and Electrical Measurements at Ambient Temperature (25°C +/- 1°C) - Integrating Sphere Method

Intertek Sample No. LAN1404250928-001

Correlated Color Temperature (K)

3834

CRI -Ra 81.9

Input Input Voltage Current {Vac} (mA) 120.1 873.9

Base Orientation UP

CRI -R9 -8.6

DUV 0.008

CIE 31’ Chromaticity Coordinate (x) 0.382

Input Power (Watts) 103.6

Input Current Power ATHD Factor (%) 0.987 11.41

CIE 31’ Chromaticity Coordinate (y) 0.362

Luminous Flux (Lumens) 3680

CIE 76’ Chromaticity Coordinate (u’) 0.232

Lumen Efficacy (LPW) 35.52

CIE 76’ Chromaticity Coordinate (v’) 0.495

Spectral Distribution over Visible Wavelengths nm 350 355 360 365 370 375 380 385 390 395 400 405 410 415 420 425 430 435

mW/nm -0.077 -0.075 -0.079 -0.035 -0.059 -0.099 -0.074 0.015 -0.076 -0.011 0.042 0.178 0.443 1.173 2.470 4.862 8.647 14.510

nm 440 445 450 455 460 465 470 475 480 485 490 495 500 505 510 515 520 525

mW/nm 23.340 36.010 49.730 52.990 42.150 30.420 23.340 18.130 14.790 13.590 13.760 15.010 17.140 19.850 22.620 25.280 27.680 29.600

nm 530 535 540 545 550 555 560 565 570 575 580 585 590 595 600 605 610 615

mW/nm 31.330 32.670 33.970 35.080 36.080 37.130 38.200 39.290 40.670 42.050 43.510 45.150 47.200 50.360 55.330 60.320 55.490 44.900

nm 620 625 630 635 640 645 650 655 660 665 670 675 680 685 690 695 700 705

mW/nm 38.000 33.800 30.680 27.950 25.450 23.040 20.810 18.720 16.710 14.870 13.170 11.600 10.200 8.912 7.780 6.754 5.901 5.100

nm 710 715 720 725 730 735 740 745 750 755 760 765 770 775 780

mW/nm 4.471 3.871 3.365 2.917 2.497 2.166 1.866 1.614 1.395 1.240 1.062 0.908 0.785 0.683 0.587

Spectral Data Over Visible Wavelengths

70.000 60.000

(mW/nm)

50.000 40.000 30.000

20.000 10.000 0.000 350

400

450

500

550

600

650

700

750

800

Nanometers

Report No. 101607677LAX-001

4 of 7

Date: April 29, 2014

RESULTS OF TEST (cont'd) Photometric and Electrical Measurements at Ambient Temperature (25°C +/- 1°C) – Distribution Method

Intertek Sample No. LAN1404250928-001

Input Input Voltage Current {Vac} (mA) 120.0 865.6

Base Orientation UP

Input Power (Watts) 102.5

Input Absolute Lumen Efficacy Power Luminous Flux (Lumens Per Factor (Lumens) Watt) 0.987 3712 36.21

Intensity (Candlepower) Summary at 25°C - Candelas Maximum Candela Value: Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90

0 33724 29628 12895 3758 1053 488 283 170 106 74 51 32 30 9 26 0 7 10 1

22.5 33783 29566 13022 3793 1046 478 295 169 100 79 46 31 30 13 3 15 5 12 0

33885 45 33757 29579 13329 3886 1063 493 294 191 108 69 60 40 34 9 20 1 7 0 0

Report No. 101607677LAX-001

67.5 33885 29697 13621 3946 1096 492 312 178 104 74 57 36 38 8 5 11 7 11 5

90 33834 29584 13800 4065 1123 509 310 173 117 75 65 47 29 21 10 5 0 4 0

5 of 7

Date: April 29, 2014

RESULTS OF TEST (cont'd) Illumination Plots Mounting Height: 10 ft. Illuminance - Cone of Light

Isoillumination Plot

Zonal Lumens and Percentages at 25°C

Zonal Lumen Summary and Percentages at 25°C Zone Lumens 0-30 3482 0-40 3594 0-60 3687 60-90 25.1 0-90 3712 90-180 0.2 0-180 3712

Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100

% Luminaire 93.8 96.8 99.3 0.7 100.0 0.0 100.0

Report No. 101607677LAX-001

6 of 7

Lumens 2114 1129 239.4 112.2 57.9 34.3 14.2 6.6 4.4 0.2

% Luminaire 56.9 30.4 6.4 3.0 1.6 0.9 0.4 0.2 0.1 0.0

Date: April 29, 2014

PICTURE (not to scale) X

CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report.

In Charge Of Tests:

Report Reviewed By:

Erik Linares Technician Lighting Division

Kenda Branch Engineer Lighting Division

Attachment: None

Report No. 101607677LAX-001