5D
Safety module CS FS-1 Technical data Housing Made of polyamide PA 6.6 self-extinguishing, class V0 (UL94) Protection degree: IP40 (housing), IP20 (terminals) Dimensions: see page 5/82, shape C
Safety timer module with delayed contacts at energizing Main functions • For safety applications up to SIL 3 / PL e • Timed circuits through safety system with self-monitoring and redundancy • Suitable to control safety interlocked devices • 45 mm housing • Output contacts: 1 NO safety contact, 2 NC auxiliary contacts, • Supply voltages: 24 Vac/dc, 120 Vac, 230 Vac
Utilization categories Alternate current: AC15 (50...60 Hz) Ue (V) 230 Ie (A) 3 Direct current: DC13 (6 operations/minute) Ue (V) 24 Ie (A) 4
up to SIL 3 according to EN IEC 62061 up to PL e according to EN ISO 13849-1 up to cat. 4 according to EN ISO 13849-1 (dependent from the circuit structure) see page 7/34 -25°C...+55°C >10 millions of operations >100.000 operations outside 3, inside 2 2.5 kV 250 V II 0,2 kg
Power supply Rated operating voltage (Un): Max residual ripple in DC: Supply voltage tolerance: Rated power consumption AC: Rated power consumption DC:
24 Vac/dc; 50...60 Hz 120 Vac; 50...60 Hz 230 Vac; 50...60 Hz 10% 15% of Un < 5 VA < 2W
Control circuit Protection against short circuits: Operating time of PTC: Operating time tA: Releasing time in absence of power supply tR:
resistance PTC, Ih=0,5 A intervention > 100 ms, reset > 3 s see “Code structure” < 40 ms
In conformity with standards: IEC 60947-1, EN 60947-5-1, IEC 60204-1, EN 60204-1, EN ISO 13849-1, EN 999, EN 1037, EN ISO 12100-1, EN ISO 12100-2, EN ISO 13850, IEC 529, EN 60529, EN 61000-6-2, EN 61000-6-3, EN 62326-1, EN 60664-1, EN 60947-5-1, EN 62061, EN 13849-1, UL 508, CSA C22.2 n° 14-95
Markings, quality marks and certificates:
Approval UL: Approval GOST:
General data SIL level (SIL CL): Performance Level (PL): Safety category: Safety parameters: Ambient temperature: Mechanical endurance: Electrical endurance: Pollution degree: Rated impulse with stand voltage (Uimp): Rated insulation voltage (Ui): Over-voltage category: Weight:
E131787 POCC IT.AB24.B04512
Complying with the requirements requested by: Low Voltage Directive 2006/95/EC, Machinery Directive 2006/42/EC, Electromagnetic Compatibility 2004/108/EC
Output circuit Output contacts: Contacts type: Contacts material: Max switching voltage: Max switching current per contact: Conventional free air thermal current Ith: Max currents sum Σ Ith2: Min. current: Contacts resistance: Contact protection fuse:
1 NO safety contact, 2 NC auxiliary contacts, forced guided contacts silver alloy 230/240 Vac; 300 Vdc 6A 6A 36 A2 10 mA 100 m 6 A, F type
The number and the load capacity of output contacts can be increased by using expansion modules or contactors See page See page 5/51 - 5/61.
Releasing time delayed contacts Code structure
CS FS-11V024-TF1 Operating time tA 0 Fixed time (see TFx) 1 from 0,3 to 3 s, step 0,3 s 2 from 1 to 10 s, step 1 s 3 from 3 to 30 s, step 3 s 4 from 30 to 300 s, step 30 s Kind of connection V screw terminals M connector with screw terminals X connector with spring terminals
5/35
Operating time tA TF0.5 fixed 0,5 s TF1 fixed 1 s TF3 fixed 3 s TF10 fixed 10 s Supply voltage 024 24 Vac/dc
15%
120 120 Vac
15%
230 230 Vac
15%
Data type approved by UL Rated operating voltage (Un): Rated power consumption AC: Rated power consumption DC: Max switching voltage: Max switching current per contact: Utilization category
24 Vac/dc; 50...60 Hz 120 Vac; 50...60 Hz 230 Vac; 50...60 Hz < 5 VA < 2W 230 Vac 6A C300
Note: - Use 60° or 75 °C copper (Cu) conductor and wire size No. 30-12 AWG. - Terminal tightening torque of 5-7 Lb In. - Only for 24 Vac/dc version, supply from remote class 2 source or limited voltage and limited energy.
General Catalog 2013-2014
5D Safety module CS FS-1 Operations diagram
Terminals layout
A1
17
Y1
Y2
25
35 A1/A2 17/18 25/26 ITALY
35/36
PWR CH1 CH2
tA
240 270 300 210 180 T[s] 150 120 90 60 30
tR
Legend: tA: Adjustable operating time (see “Code structure”) tR: Releasing time in absence of power supply A2
18
26
36
Internal wiring diagram L/+ A1
Y1
Y2
LED CH1
LOGIC CIRCUIT
LOGIC CIRCUIT
17
25
35
18
26
36
LED CH2
K2
LED PWR
K1 TIMER 1
TIMER 2
PE
A2
N/-
Circuit structure Control of a door-lock system with manual release L/+
F
STOP
K1
State 1: closed and locked gate. Interlock safety switch contacts closed
F
F
F
F
K1
START
Start
K2
K2 A1
Y1
Y2
A1 S11 S12 S31
17
Safety timer module CS FS-1 A2
S33
S34
23
13
Safety module CS AR-08 18
Safety switch
A2
Stop
State 3: base module and relay not activated. Timing start of CS FS-1
24
14
S21 S22 S35
K1
Timing
Door release K2 A1
21
11
A2
22
12
N/-
State 2: base module and relay activated. Module CS FS-1 not powered
M
State 4: closing delayed contacts of CS FS-1. Possibility of gate release through the push button
FG 60AD1D0A
The diagram shown displays the operation principle of a typical circuit for the control of a door-lock system with door blocking when interlock safety switch is not energized, and manual release of the single doors. In order to obtain the complete wiring diagram with different modalities of electrical blocking or with automatic door release, please contact our technical office. The diagram does not show the exact position of clamps in the product
General Catalog 2013-2014
5/36
5D
Safety module CS FS-2 Technical data Housing Made of polyamide PA 6.6 self-extinguishing, class V0 (UL94) Protection degree: IP40 (housing), IP20 (terminals) Dimensions: see page 5/82 shape C
Safety timer module with delayed contacts at energizing Main functions • For safety applications up to SIL 2 / PL d • Timed circuits through safety system with self-monitoring and redundancy • Suitable to control safety interlocked devices • 45 mm housing • Output contacts: 1 NO safety contact, 1 NC auxiliary contact, 1 CO auxiliary contact, • Supply voltages: 24 Vdc, 120 Vac
General data SIL level (SIL CL): Performance Level (PL): Safety category: Safety parameters: Ambient temperature: Mechanical endurance: Electrical endurance: Pollution degree: Rated impulse with stand voltage (Uimp): Rated insulation voltage (Ui): Over-voltage category: Weight:
up to SIL 2 according to EN IEC 62061 up to PL d according to EN ISO 13849-1 up to cat. 3 according to EN ISO 13849-1 see page 7/34 -25°C...+55°C >10 millions of operations >100.000 operations outside 3, inside 2 4 kV 250 V II 0,2 kg
Power supply Rated operating voltage (Un): Max residual ripple in DC: Supply voltage tolerance: Rated power consumption AC: Rated power consumption DC:
24 Vdc (A1-A2) 120 Vac; 50...60 Hz (B1-B2) 10% 15% of Un < 5 VA < 2W
Control circuit Protection against short circuits: Operating time of PTC: Operating time tA: Releasing time in absence of power supply tR:
resistance PTC, Ih=0,5 A intervention > 100 ms, reset > 3 s see “Code structure” < 40 ms
In conformity with standards: IEC 60947-1, EN 60947-5-1, IEC 60204-1, EN 60204-1, EN ISO 13849-1, EN 999, EN 1037, EN ISO 12100-1, EN ISO 12100-2, EN ISO 13850, IEC 529, EN 60529, EN 61000-6-2, EN 61000-6-3, EN 62326-1, EN 60664-1, EN 60947-5-1, EN 62061, EN 13849-1, UL 508, CSA C22.2 n° 14-95
Utilization categories Alternate current: AC15 (50...60 Hz) Ue (V) 230 Ie (A) 3 Direct current: DC13 (6 operations/minute) Ue (V) 24 Ie (A) 4 Markings and quality marks:
Approval UL: E131787 Approval TÜV SÜD: Z10 10 09 75157 002 Approval GOST: POCC IT.AB24.B04512 Complying with the requirements requested by: Low Voltage Directive 2006/95/EC, Machinery Directive 2006/42/EC, Electromagnetic Compatibility 2004/108/EC
Output circuit Output contacts: Contacts type: Contacts material: Max switching voltage: Max switching current per contact: Conventional free air thermal current Ith: Max currents sum Σ Ith2: Min. current: Contacts resistance: Contact protection fuse: Error signalling output (Y14): Rated operational voltage (Ue): Rated operational current (Ie):
1 NO safety contact, 1 NC auxiliary contact, 1 CO auxiliary contact, forced guided contacts silver alloy 230/240 Vac; 300 Vdc 6A 6A 36 A2 10 mA 100 m 6 A, F type Type PNP 24 Vdc 10 mA
The number and the load capacity of output contacts can be increased by using expansion modules or contactors. See page See page 5/51 - 5/61.
Data type approved by UL
Releasing time delayed contacts Code structure
CS FS-20VU24-TFxx Operating time tA
Operating time tA
0 1 2 3 4
TFxx xx s (fixed time)
Fixed time (see TFxx) from 0,3 to 3 s, step 0,3 s from 1 to 10 s, step 1 s from 3 to 30 s, step 3 s from 30 to 300 s, step 30 s
Kind of connection V screw terminals M connector with screw terminals X connector with spring terminals
5/37
Rated operating voltage (Un): 24 Vdc, 120 Vac; 50...60 Hz: Rated power consumption AC: < 5 VA Rated power consumption DC: < 2 W Max switching voltage: 230 Vac Max switching current per contact: 6 A Utilization category: C300
- Use 60° or 75 °C copper (Cu) conductor and wire size No. 30-12 AWG. - Terminal tightening torque of 5-7 Lb In. - Only for 24 Vac/dc version, supply from remote class 2 source or limited voltage and limited energy.
Data type approved by TÜV SÜD
Supply voltage U24 24 Vdc 24 Vdc (A1-A2) 120 120 Vac (B1-B2)
15% 15% 15%
Rated operating voltage (Un): 24 Vdc; ± 15%, 120 Vac ± 15% Rated power consumption: 5 VA max AC, 2 W max DC Output switching current (max): 4 A Output switching power (max): 1380 VA Working temperature: -25 °C … + 55°C Storage temperature: -25 °C … + 70°C Protection degree: IP40 (housing), IP20 (terminals) Tested according to: 2006/42/EEC Machine Directive, EN ISO 138491:2008 (up to Cat. 4 PL e), EN 50178:1997, EN 60947-5-3/A1:2005, EN 61508-1:1998 (SIL 1-3), EN 61508-2:2000 (SIL 1-3), EN 615084:1998 (SIL 1-3), IEC 62061:2005 (SIL CL 3)
General Catalog 2013-2014
5D Safety module CS FS-2 Operations diagram
Terminals layout CS FS-20••••-TFxx
CS FS-2••••• Delay on Normal operation without faults
CS FS-2•••••
35
36
38
17
35
36
38
17
A1
A2
B1
B2
A1
A2
B1
B2
A1/A2 - B1/B2 17/18
ITALY
ITALY
PWR
25/26
PWR
OUT
OUT
FAULT
FAULT
35/36
240 270 300 210 180 T[s] 150 120 90 60 30
DELAY: xx sec
35/38
tA 25
26 Y14 18
25
26 Y14 18
tR
Legend: tA: Adjustable operating time (see “Code structure”) tR: Releasing time in absence of power supply
Internal wiring diagram L
+
B1
A1
17
25
18
26
35
OUT
K3
P1
LED PWR
K1 FAULT
P2
B2
A2
N
-
Y14
K2
36
38
A1-A2: 24 Vdc B1-B2: 120 Vac
General Catalog 2013-2014
5/38
5D
Safety module CS FS-3 Technical data Housing Made of polyamide PA 6.6 self-extinguishing, class V0 (UL94) Protection degree: IP40 (housing), IP20 (terminals) Dimensions: see page 5/82 shape C
Safety timer module with ON pulse function Main functions • For safety applications up to SIL 2 / PL d • Timed circuits through safety system with self-monitoring and redundancy • Suitable to control safety interlocked devices • 45 mm housing • Output contacts: 1 NO safety contact, 1 NC auxiliary contact, 1 CO auxiliary contact, • Supply voltages: 24 Vdc, 120 Vac
General data SIL level (SIL CL): Performance Level (PL): Safety category: Safety parameters: Ambient temperature: Mechanical endurance: Electrical endurance: Pollution degree: Rated impulse with stand voltage (Uimp): Rated insulation voltage (Ui): Over-voltage category: Weight:
up to SIL 2 according to EN IEC 62061 up to PL d according to EN ISO 13849-1 up to cat. 3 according to EN ISO 13849-1 see page 7/34 -25°C...+55°C >10 millions of operations >100.000 operations outside 3, inside 2 4 kV 250 V II 0,2 kg
Power supply Rated operating voltage (Un): Max residual ripple in DC: Supply voltage tolerance: Rated power consumption AC: Rated power consumption DC:
24 Vdc (A1-A2) 120 Vac; 50...60 Hz (B1-B2) 10% 15% of Un < 5 VA < 2W
Control circuit Protection against short circuits: Operating time of PTC: ng time tA: Releasing time in absence of power supply tR: Start-up time tS:
resistance PTC, Ih=0,5 A see “Code structure” < 40 ms < 200 ms
In conformity with standards: IEC 60947-1, EN 60947-5-1, IEC 60204-1, EN 60204-1, EN ISO 13849-1, EN 999, EN 1037, EN ISO 12100-1, EN ISO 12100-2, EN ISO 13850, IEC 529, EN 60529, EN 61000-6-2, EN 61000-6-3, EN 62326-1, EN 60664-1, EN 60947-5-1, EN 62061, EN 13849-1, UL 508, CSA C22.2 n° 14-95
Utilization categories Alternate current: AC15 (50...60 Hz) Ue (V) 230 Ie (A) 3 Direct current: DC13 (6 operations/minute) Ue (V) 24 Ie (A) 4 Markings and quality marks:
Approval UL: E131787 Approval TÜV SÜD: Z10 10 09 75157 002 Approval GOST: POCC IT.AB24.B04512 Complying with the requirements requested by: Low Voltage Directive 2006/95/EC, Machinery Directive 2006/42/EC, Electromagnetic Compatibility 2004/108/EC
Output circuit Output contacts: Contacts type: Contacts material: Max switching voltage: Max switching current per contact: Conventional free air thermal current Ith: Max currents sum Σ Ith2: Min. current: Contacts resistance: Contact protection fuse: Error signalling output (Y14): Rated operational voltage (Ue): Rated operational current (Ie):
1 NO safety contact, 1 NC auxiliary contact, 1 CO auxiliary contact, forced guided contacts silver alloy 230/240 Vac; 300 Vdc 6A 6A 36 A2 10 mA 100 m 6 A, F type Type PNP 24 Vdc 10 mA
The number and the load capacity of output contacts can be increased by using expansion modules or contactors. See page See page 5/51 - 5/61.
Data type approved by UL
Releasing time delayed contacts Code structure
CS FS-30VU24-TFxx Releasing time tA 0 Fixed time (see TFxx) 1 from 0,3 to 3 s, step 0,3 s 2 from 1 to 10 s, step 1 s 3 from 3 to 30 s, step 3 s 4 from 30 to 300 s, step 30 s Kind of connection V screw terminals M connector with screw terminals X connector with spring terminals
5/39
Releasing time tA TFxx xx s (fixed time)
Rated operating voltage (Un): 24 Vdc, 120 Vac; 50...60 Hz: Rated power consumption AC: < 5 VA Rated power consumption DC: < 2 W Max switching voltage: 230 Vac Max switching current per contact: 6 A Utilization category: C300
- Use 60° or 75 °C copper (Cu) conductor and wire size No. 30-12 AWG. - Terminal tightening torque of 5-7 Lb In. - Only for 24 Vac/dc version, supply from remote class 2 source or limited voltage and limited energy.
Data type approved by TÜV SÜD
Supply voltage U24 24 Vdc 24 Vdc (A1-A2) 120 120 Vac (B1-B2)
15% 15% 15%
Rated operating voltage (Un): 24 Vdc; ± 15%, 120 Vac ± 15% Rated power consumption: 5 VA max AC, 2 W max DC Output switching current (max): 4 A Output switching power (max): 1380 VA Working temperature: -25 °C … + 55°C Storage temperature: -25 °C … + 70°C Protection degree: IP40 (housing), IP20 (terminals) Tested according to: 2006/42/EEC Machine Directive, EN ISO 138491:2008 (up to Cat. 4 PL e), EN 50178:1997, EN 60947-5-3/A1:2005, EN 61508-1:1998 (SIL 1-3), EN 61508-2:2000 (SIL 1-3), EN 615084:1998 (SIL 1-3), IEC 62061:2005 (SIL CL 3)
General Catalog 2013-2014
5D Safety module CS FS-3 Operations diagram
Terminals layout CS FS-30••••-TFxx
CS FS-3••••• Delay off Normal operation without faults
CS FS-3•••••
35
36
38
17
35
36
38
17
A1
A2
B1
B2
A1
A2
B1
B2
A1/A2 - B1/B2 17/18
ITALY
25/26
ITALY
PWR
PWR
OUT
OUT
FAULT
35/36
FAULT 240 270 300 210 180 T[s] 150 120 90 60 30
DELAY: xx sec
35/38
tS
tA
Operation without power supply 25
26 Y14 18
25
26 Y14 18
A1/A2 - B1/B2 17/18 25/26 35/36
Internal wiring diagram L
+
B1
A1
35/38
tS 17
25
18
26
Legend: tA: Adjustable releasing time (see “Code structure”) tA1: Releasing time if power supply is minor to tA tR: Releasing time in absence of power supply tS: Start-up time
K3
P1
tR
35
OUT
LED PWR
tA1
K1 FAULT
P2
B2
A2
N
-
Y14
K2
36
38
A1-A2: 24 Vdc B1-B2: 120 Vac
General Catalog 2013-2014
5/40
5D
Safety module CS FS-5 Technical data
Safety timer module with delayed contacts at opening of the input channels Main functions • For safety applications up to SIL 2 / PL d • Timed circuits through safety system with self-monitoring and redundancy • Suitable to control safety interlocked devices • 45 mm housing • Output contacts: 1 NO safety contact, 1 NC auxiliary contact, 1 CO auxiliary contact, • Supply voltages: 24 Vdc, 120 Vac
Utilization categories Alternate current: AC15 (50...60 Hz) Ue (V) 230 Ie (A) 3 Direct current: DC13 (6 operations/minute) Ue (V) 24 Ie (A) 4 Markings and quality marks:
Approval UL: E131787 Approval TÜV SÜD: Z10 10 09 75157 002 Approval GOST: POCC IT.AB24.B04512 Complying with the requirements requested by: Low Voltage Directive 2006/95/EC, Machinery Directive 2006/42/EC, Electromagnetic Compatibility 2004/108/EC
Housing Made of polyamide PA 6.6 self-extinguishing, class V0 (UL94) Protection degree: IP40 (housing), IP20 (terminals) Dimensions: see page 5/82 shape C General data SIL level (SIL CL): up to SIL 2 according to EN IEC 62061 Performance Level (PL): up to PL d according to EN ISO 13849-1 Safety category: up to cat. 3 according to EN ISO 13849-1 Safety parameters: see page 7/34 Ambient temperature: -25°C...+55°C Mechanical endurance: >10 millions of operations Electrical endurance: >100.000 operations Pollution degree: outside 3, inside 2 Rated impulse with stand voltage (Uimp): 4 kV Rated insulation voltage (Ui): 250 V Over-voltage category: II Weight: 0,2 kg Power supply Rated operating voltage (Un): 24 Vdc (A1-A2) 120 Vac; 50...60 Hz (B1-B2) Max residual ripple in DC: 10% Supply voltage tolerance: 15% of Un Rated power consumption AC: < 5 VA Rated power consumption DC: < 2W Control circuit Protection against short circuits: resistance PTC, Ih=0,5 A Operating time of PTC: intervention > 100 ms, reset > 3 s see “Code structure” Releasing time tA: Releasing time in absence of power supply tR: < 40 ms Input circuit 50 Max input resistance: Input current: < 8 mA Activation time tS: < 40 ms > 50 ms Minimum endurance of input signal tMIN: In conformity with standards: IEC 60947-1, EN 60947-5-1, IEC 60204-1, EN 60204-1, EN ISO 13849-1, EN 999, EN 1037, EN ISO 12100-1, EN ISO 12100-2, EN ISO 13850, IEC 529, EN 60529, EN 61000-6-2, EN 61000-6-3, EN 62326-1, EN 60664-1, EN 60947-5-1, EN 62061, EN 13849-1, UL 508, CSA C22.2 n° 14-95 Output circuit Output contacts: 1 NO safety contact, 1 NC auxiliary contact, 1 CO auxiliary contact, Contacts type: forced guided contacts Contacts material: silver alloy Max switching voltage: 230/240 Vac; 300 Vdc Max switching current per contact: 6A Conventional free air thermal current Ith: 6A Max currents sum Σ Ith2: 36 A2 Min. current: 10 mA Contacts resistance: 100 m Contact protection fuse: 6 A, F type Error signalling output (Y14): Type PNP Rated operational voltage (Ue): 24 Vdc Rated operational current (Ie): 10 mA The number and the load capacity of output contacts can be increased by using expansion modules or contactors. See page See page 5/51 - 5/61.
Data type approved by UL
Releasing time delayed contacts Code structure
CS FS-50VU24-TFxx Releasing time tA 0 Fixed time (see TFxx) 1 from 0,3 to 3 s, step 0,3 s 2 from 1 to 10 s, step 1 s 3 from 3 to 30 s, step 3 s 4 from 30 to 300 s, step 30 s Kind of connection V screw terminals M connector with screw terminals X connector with spring terminals
5/41
Releasing time tA TFxx xx s (fixed time)
Rated operating voltage (Un): 24 Vdc, 120 Vac; 50...60 Hz: Rated power consumption AC: < 5 VA Rated power consumption DC: < 2 W Max switching voltage: 230 Vac Max switching current per contact: 6 A Utilization category: C300
- Use 60° or 75 °C copper (Cu) conductor and wire size No. 30-12 AWG. - Terminal tightening torque of 5-7 Lb In. - Only for 24 Vac/dc version, supply from remote class 2 source or limited voltage and limited energy.
Data type approved by TÜV SÜD
Supply voltage U24 24 Vdc 24 Vdc (A1-A2) 120 120 Vac (B1-B2)
15% 15% 15%
Rated operating voltage (Un): 24 Vdc; ± 15%, 120 Vac ± 15% Rated power consumption: 5 VA max AC, 2 W max DC Output switching current (max): 4 A Output switching power (max): 1380 VA Working temperature: -25 °C … + 55°C Storage temperature: -25 °C … + 70°C Protection degree: IP40 (housing), IP20 (terminals) Tested according to: 2006/42/EEC Machine Directive, EN ISO 138491:2008 (up to Cat. 4 PL e), EN 50178:1997, EN 60947-5-3/A1:2005, EN 61508-1:1998 (SIL 1-3), EN 61508-2:2000 (SIL 1-3), EN 615084:1998 (SIL 1-3), IEC 62061:2005 (SIL CL 3)
General Catalog 2013-2014
5D Safety module CS FS-5 Operations diagram
Terminals layout CS FS-50••••-TFxx
CS FS-5•••••
35
36
38
17
35
36
38
17
A1
A2
B1
B2
A1
A2
B1
B2
Configuration with automatic start
A1/A2 - B1/B2 ITALY
ITALY
PWR
PWR
OUT
OUT
FAULT
FAULT
activation conditions safety output
240 270 300 210 180 T[s] 150 120 90 60 30
DELAY: xx sec
S11 S12 S52 S34
S11 S12 S52 S34
25
25
26 Y14 18
tS
tA
tS
tR
t< tA
Configuration with manual start
26 Y14 18
A1/A2 - B1/B2 activation conditions start safety output
tS
Internal wiring diagram
tA
tS
tMIN L
tR
t< tA
tMIN
+
B1
A1
S12 S52
S11
S34
17
35
25
Legend: tA: Adjustable releasing time (see “Code structure”) tR: Releasing time in absence of power supply tS: Activation time tMIN: Minimum endurance of input signal
OUT
K3 LED PWR
P1
K1 FAULT
P2
B2
A2
N
-
K2
18
Y14
26
36
38
A1-A2: 24 Vdc B1-B2: 120 Vac Inputs configuration Gate monitoring Input configuration with manual start 1 channel
2 channels
+
N
S12
S11
A1
S52
+
B2
S11
A1
CS FS-5 A2
Automatic start
General Catalog 2013-2014
B1
-
L
As regards the indicated diagrams, in order to activate the module with the automatic start, it is necessary to short the start button between S33 and S34 terminals.
S12
S52
B2
S34
A2
CS FS-5 S34
B1
N
L
-
Gate monitoring and safety magnetic sensors. S1
S1
S34
S34
The safety module can control both gate monitoring circuits or safety magnetic sensors. Replace the switches contacts with the sensors contacts. The sensors can only be used in the 2-channel configuration.
5/42