Regulations Compliance Report Approved Document L1A 2010 edition assessed by Stroma FSAP 2009 program, Version: 1.5.0.79 Printed on 16 October 2014 at 10:09:35 Project Information: Assessed By:
Mark Heptonstall (STRO004925)
Building Type:
Flat
Plot Reference:
F06
Dwelling Details: NEW DWELLING DESIGN STAGE Site Reference : 80 Woodcote Valley Road Address :
F06, 80 Woodcote Valley Road, Purley, Croydon, CR8 3BE
Client Details: Name: Address : This report covers items included within the SAP calculations. It is not a complete report of regulations compliance. 1 TER and DER Fuel for main heating system: Natural gas Fuel factor: 1.00 (natural gas) Target Carbon Dioxide Emission Rate (TER) Dwelling Carbon Dioxide Emission Rate (DER) 2 Fabric U-values Element Average External wall 0.24 (max. 0.30) Party wall 0.00 (max. 0.20) Floor 0.10 (max. 0.25) Roof (no roof) Openings 1.40 (max. 2.00) 3 Air permeability Air permeability at 50 pascals Maximum 4 Heating efficiency Main Heating system:
Secondary heating system:
21.69 kg/m² 14.80 kg/m²
OK
Highest 0.25 (max. 0.70) 0.10 (max. 0.70)
OK OK OK
1.40 (max. 3.30)
OK
5.00 10.0
Boiler system with radiators or underfloor - mains gas Data from manufacturer Combi boiler Efficiency 89.0 % SEDBUK2009 Minimum 88.0 %
OK
OK
None
5 Cylinder insulation Hot water Storage: No cylinder 6 Controls Space heating controls Programmer, room thermostat and TRVs Hot water controls: No cylinder Boiler interlock: Yes 7 Low energy lights Percentage of fixed lights with low-energy fittings 100.0% Minimum 75.0%
Stroma FSAP 2009 Version: 1.5.0.79 (SAP 9.90) - http://www.stroma.com
N/A OK OK
OK
Page 1 of 2
Regulations Compliance Report 8 Mechanical ventilation Not applicable 9 Summertime temperature Overheating risk (Thames valley): Based on: Overshading: Windows facing: South Windows facing: North Windows facing: East Windows facing: West Ventilation rate: Blinds/curtains:
Slight
OK
Average or unknown 3.8m², Overhang twice as wide as window, ratio NaN 6.35m², Overhang twice as wide as window, ratio NaN 2.5m², Overhang twice as wide as window, ratio NaN 0.6m², Overhang twice as wide as window, ratio NaN
6.00 shutter closed 100% of daylight hours
10 Key features Windows U-value Doors U-value Floors U-value Photovaltaic array
Stroma FSAP 2009 Version: 1.5.0.79 (SAP 9.90) - http://www.stroma.com
1.4 W/m²K 1.4 W/m²K 0.1 W/m²K
Page 2 of 2
SAP Input Property Details: F06 F06, 80 Woodcote Valley Road, Purley, Croydon, CR8 3BE Address: England Located in: Thames valley Region: UPRN: 27 August 2014 Date of assessment: 16 October 2014 Date of certificate: New dwelling design stage Assessment type: New dwelling Transaction type: Unknown Tenure type: No related party Related party disclosure: Indicative Value Low Thermal Mass Parameter: Dwelling designed to use less than 125 litres per Person per day: True Property description:
Dwelling type: Detachment: Year Completed:
Flat
Floor Location: Floor 0
Floor area:
Living area: Front of dwelling faces:
24.16 m² (fraction 0.432) South
2014
Storey height:
55.88 m²
2.5 m
Opening types:
Name:
Source:
Type:
Glazing:
Argon:
Frame:
Entrance Front Rear Side Side
Manufacturer Manufacturer Manufacturer Manufacturer Manufacturer
Solid Windows Windows Windows Windows
double-glazed double-glazed double-glazed double-glazed
Yes Yes Yes Yes
Wood PVC-U PVC-U PVC-U PVC-U
Name:
Gap:
Frame Factor: g-value:
U-value:
Area:
No. of Openings:
Entrance Front Rear Side Side
mm 16mm 16mm 16mm 16mm
0.7 0.7 0.7 0.7 0.7
1.4 1.4 1.4 1.4 1.4
1.89 3.8 6.35 2.5 0.6
1 1 1 1 1
Name:
Type-Name:
Entrance Front Rear Side Side
Overshading:
or or or or
more more more more
Location:
Communal Walls External Walls External Walls External Walls External Walls
0 0.76 0.76 0.76 0.76
Orient:
Width:
South South North East West
0 0 0 0 0
Height: 0 0 0 0 0
Average or unknown
Opaque Elements:
Type: Gross area: External Elements External Walls Communal Walls Ground Floor
Internal Elements Party Elements Party Walls
53.2 18.15 55.88
Openings: 13.25 1.89
Net area:
U-value:
39.95 16.26
0.25 0.25 0.1
14.5
Stroma FSAP 2009 Version: 1.5.0.79 (SAP 9.90) - http://www.stroma.com
Ru value: 0 0.43
Curtain wall: False False
Kappa: N/A N/A N/A
N/A
Page 1 of 2
SAP Input Thermal bridges:
Thermal bridges:
Ventilation: Pressure test: Ventilation: Number of chimneys: Number of open flues: Number of fans: Number of sides sheltered: Pressure test:
User-defined y-value y =0.04 Reference: ECDs
Yes (As designed) Natural ventilation (extract fans) 0 0 2 3 5
Main heating system:
Main heating system:
Central heating systems with radiators or underfloor heating Gas boilers and oil boilers Fuel: mains gas Info Source: Manufacturer Declaration Manufacturer's data Efficiency: 89.0% (SEDBUK2009) Condensing combi with automatic ignition Fuel Burning Type: Systems with radiators Pump in heat space: Yes Enhanced Load Compensator Delayed start
Main heating Control:
Main heating Control:
Programmer, room thermostat and TRVs Control code: 2106 Boiler interlock: Yes
Secondary heating system:
Secondary heating system:
None
Water heating:
Water heating:
From main heating system Water code: 901 Fuel :mains gas No hot water cylinder Solar panel: False
Others:
Electricity tariff: In Smoke Control Area: Conservatory: Low energy lights: Terrain type: EPC language: Wind turbine: Photovoltaics:
standard tariff Unknown No conservatory 100% Low rise urban / suburban English No
Assess Zero Carbon Home:
No
Photovoltaic 1
Installed Peak power: 0.53 Tilt of collector: 30° Overshading: None or very little Collector Orientation: South
Stroma FSAP 2009 Version: 1.5.0.79 (SAP 9.90) - http://www.stroma.com
Page 2 of 2
SAP 2009 Overheating Assessment Calculated by Stroma FSAP 2009 program, produced and printed on 16 October 2014
Property Details: F06 Flat England Thames valley Yes 1 South Average or unknown None Indicative Value Low False
Dwelling type: Located in: Region: Cross ventilation possible: Number of storeys: Front of dwelling faces: Overshading: Overhangs: Thermal mass parameter: Night ventilation: Blinds, curtains, shutters: Ventilation rate during hot weather (ach):
6 ( Windows fully open)
Overheating Details: 276.61 44.5 321.15
Summer ventilation heat loss coefficient: Transmission heat loss coefficient: Summer heat loss coefficient:
(P1) (P2)
Overhangs: Orientation:
Ratio:
Z_overhangs:
South (Front) North (Rear) East (Side) West (Side)
0 0 0 0
1 1 1 1
Orientation:
Z blinds:
Solar access:
Overhangs:
Z summer:
South (Front) North (Rear) East (Side) West (Side)
1 1 1 1
0.9 0.9 0.9 0.9
1 1 1 1
0.9 0.9 0.9 0.9
Solar shading:
(P8) (P8) (P8) (P8)
Solar gains: Orientation (calculation for July) South (Front) 0.9 x North (Rear) 0.9 x East (Side) 0.9 x West (Side) 0.9 x
Area 3.8 6.35 2.5 0.6
Flux 110.52 85.34 117.78 117.78
g_ 0.76 0.76 0.76 0.76
FF 0.7 0.7 0.7 0.7
Shading 0.9 0.9 0.9 0.9 Total
Gains 180.98 233.53 126.89 30.45 571.85 (P3/P4)
July 326.89 898.75 2.8 17.8 1.3 21.9 Slight
August 334.07 835.25 (P5) (P6) 2.6 17.8 1.3 (P7) 21.7 Slight
Internal gains:
Internal gains Total summer gains Summer gain/loss ratio Mean summer external temperature (Thames valley) Thermal mass temperature increment Threshold temperature Likelihood of high internal temperature
Stroma FSAP 2009 Version: 1.5.0.79 (SAP 9.90) - http://www.stroma.com
June 340.57 944.12 2.94 15.4 1.3 19.64 Not significant
Page 1 of 2
SAP 2009 Overheating Assessment Assessment of likelihood of high internal temperature:
Stroma FSAP 2009 Version: 1.5.0.79 (SAP 9.90) - http://www.stroma.com
Slight
Page 2 of 2
Predicted Energy Assessment F06 Dwelling type: Ground floor Flat 80 Woodcote Valley Road Date of assessment: 27 August 2014 Purley Produced by: Mark Heptonstall Croydon Total floor area: 55.88 m² CR8 3BE This is a Predicted Energy Assessment for a property which is not yet complete. It includes a predicted energy rating which might not represent the final energy rating of the property on completion. Once the property is completed, an Energy Performance Certificate is required providing information about the energy performance of the completed property. Energy performance has been assessed using the SAP 2009 methodology and is rated in terms of the energy use per square metre of floor area, energy efficiency based on fuel costs and environmental impact based on carbon dioxide (CO2) emissions.
Energy Efficiency Rating
The energy efficiency rating is a measure of the overall efficiency of a home. The higher the rating the more energy efficient the home is and the lower the fuel bills are likely to be.
Environmental Impact (CO2) Rating
The environmental impact rating is a measure of a home’s impact on the environment in terms of carbonn dioxide (CO2) emissions. The higher the rating the less impact it has on the environment.