Regulations Compliance Report

Report 5 Downloads 66 Views
Regulations Compliance Report Approved Document L1A 2010 edition assessed by Stroma FSAP 2009 program, Version: 1.5.0.79 Printed on 16 October 2014 at 10:09:29 Project Information: Assessed By:

Mark Heptonstall (STRO004925)

Building Type:

Maisonette

Plot Reference:

F07

Dwelling Details: NEW DWELLING DESIGN STAGE Site Reference : 80 Woodcote Valley Road Address :

F07, 80 Woodcote Valley Road, Purley, Croydon, CR8 3BE

Client Details: Name: Address : This report covers items included within the SAP calculations. It is not a complete report of regulations compliance. 1 TER and DER Fuel for main heating system: Natural gas Fuel factor: 1.00 (natural gas) Target Carbon Dioxide Emission Rate (TER) Dwelling Carbon Dioxide Emission Rate (DER) 2 Fabric U-values Element Average External wall 0.26 (max. 0.30) Party wall 0.00 (max. 0.20) Floor 0.20 (max. 0.25) Roof 0.15 (max. 0.20) Openings 1.40 (max. 2.00) 3 Air permeability Air permeability at 50 pascals Maximum 4 Heating efficiency Main Heating system:

Secondary heating system:

18.94 kg/m² 13.67 kg/m²

OK

Highest 0.30 (max. 0.70) 0.20 (max. 0.70) 0.16 (max. 0.35) 1.40 (max. 3.30)

OK OK OK OK OK

5.00 10.0

Boiler system with radiators or underfloor - mains gas Data from manufacturer Combi boiler Efficiency 89.0 % SEDBUK2009 Minimum 88.0 %

OK

OK

None

5 Cylinder insulation Hot water Storage: No cylinder 6 Controls Space heating controls Programmer, room thermostat and TRVs Hot water controls: No cylinder Boiler interlock: Yes 7 Low energy lights Percentage of fixed lights with low-energy fittings 100.0% Minimum 75.0%

Stroma FSAP 2009 Version: 1.5.0.79 (SAP 9.90) - http://www.stroma.com

N/A OK OK

OK

Page 1 of 2

Regulations Compliance Report 8 Mechanical ventilation Not applicable 9 Summertime temperature Overheating risk (Thames valley): Based on: Overshading: Windows facing: South Windows facing: North Windows facing: West Roof windows facing: North Roof windows facing: West Ventilation rate: Blinds/curtains:

Slight

OK

Average or unknown 2.55m², Overhang twice as wide as window, ratio NaN 7.35m², Overhang twice as wide as window, ratio NaN 1.9m², Overhang twice as wide as window, ratio NaN 0.5m² 1.9m²

8.00 shutter closed 100% of daylight hours

10 Key features Roof window U-value Windows U-value Doors U-value Photovaltaic array

Stroma FSAP 2009 Version: 1.5.0.79 (SAP 9.90) - http://www.stroma.com

1.4 W/m²K 1.4 W/m²K 1.4 W/m²K

Page 2 of 2

SAP Input Property Details: F07 F07, 80 Woodcote Valley Road, Purley, Croydon, CR8 3BE Address: England Located in: Thames valley Region: UPRN: 27 August 2014 Date of assessment: 16 October 2014 Date of certificate: New dwelling design stage Assessment type: New dwelling Transaction type: Unknown Tenure type: No related party Related party disclosure: Indicative Value Low Thermal Mass Parameter: Dwelling designed to use less than 125 litres per Person per day: True Property description:

Dwelling type: Detachment: Year Completed:

Maisonette

Floor Location: Floor 0 Floor 1

Floor area:

Living area: Front of dwelling faces:

21.1 m² (fraction 0.286) South

2014

Storey height:

49.27 m² 24.4 m²

2.5 m 2.2 m

Opening types:

Name:

Source:

Type:

Glazing:

Argon:

Frame:

Entrance Front Rear Side RL RL

Manufacturer Manufacturer Manufacturer Manufacturer Manufacturer Manufacturer

Solid Windows Windows Windows Roof Windows Roof Windows

double-glazed double-glazed double-glazed double-glazed double-glazed

Yes Yes Yes Yes Yes

Wood PVC-U PVC-U PVC-U PVC-U PVC-U

Name:

Gap:

Frame Factor: g-value:

U-value:

Area:

No. of Openings:

Entrance Front Rear Side RL RL

mm 16mm 16mm 16mm 16mm 16mm

0.7 0.7 0.7 0.7 0.7 0.7

1.4 1.4 1.4 1.4 1.4 1.4

1.89 2.55 7.35 1.9 0.5 1.9

1 1 1 1 1 1

Name:

Type-Name:

Entrance Front Rear Side RL RL

or or or or or

more more more more more

Location:

Communal Walls External Walls External Walls External Walls Sloping Roof Sloping Roof

Overshading:

0 0.76 0.76 0.76 0.76 0.76

Orient:

Width:

East South North West North West

0 0 0 0 0 0

Height: 0 0 0 0 0 0

Average or unknown

Opaque Elements:

Type: Gross area: External Elements External Walls Communal Walls Stud Walls

57.44 17.88 21.2

Openings: 11.8 1.89 0

Net area:

U-value:

45.64 15.99 21.2

0.25 0.25 0.3

Stroma FSAP 2009 Version: 1.5.0.79 (SAP 9.90) - http://www.stroma.com

Ru value: 0 0.43 0

Curtain wall: False False False

Kappa: N/A N/A N/A

Page 1 of 3

SAP Input Roof Void Roof Sloping Roof Exposed Floor

Internal Elements Party Elements Party Walls

26.32 15.13 17.29 3.02

0 0 2.4

26.32 15.13 14.89

0.14 0.14 0.16 0.2

0 0 0

24.59

N/A N/A N/A N/A

N/A

Thermal bridges:

Thermal bridges:

Ventilation: Pressure test: Ventilation: Number of chimneys: Number of open flues: Number of fans: Number of sides sheltered: Pressure test:

User-defined y-value y =0.04 Reference: ECDs

Yes (As designed) Natural ventilation (extract fans) 0 0 3 3 5

Main heating system:

Main heating system:

Central heating systems with radiators or underfloor heating Gas boilers and oil boilers Fuel: mains gas Info Source: Manufacturer Declaration Manufacturer's data Efficiency: 89.0% (SEDBUK2009) Condensing combi with automatic ignition Fuel Burning Type: Systems with radiators Pump in heat space: Yes Enhanced Load Compensator Delayed start

Main heating Control:

Main heating Control:

Programmer, room thermostat and TRVs Control code: 2106 Boiler interlock: Yes

Secondary heating system:

Secondary heating system:

None

Water heating:

Water heating:

From main heating system Water code: 901 Fuel :mains gas No hot water cylinder Solar panel: False

Others:

Electricity tariff: In Smoke Control Area: Conservatory: Low energy lights: Terrain type: EPC language: Wind turbine:

standard tariff Unknown No conservatory 100% Low rise urban / suburban English No

Stroma FSAP 2009 Version: 1.5.0.79 (SAP 9.90) - http://www.stroma.com

Page 2 of 3

SAP Input Photovoltaics:

Photovoltaic 1

Assess Zero Carbon Home:

No

Installed Peak power: 0.7 Tilt of collector: 30° Overshading: None or very little Collector Orientation: South

Stroma FSAP 2009 Version: 1.5.0.79 (SAP 9.90) - http://www.stroma.com

Page 3 of 3

SAP 2009 Overheating Assessment Calculated by Stroma FSAP 2009 program, produced and printed on 16 October 2014

Property Details: F07 Maisonette England Thames valley Yes 2 South Average or unknown None Indicative Value Low False

Dwelling type: Located in: Region: Cross ventilation possible: Number of storeys: Front of dwelling faces: Overshading: Overhangs: Thermal mass parameter: Night ventilation: Blinds, curtains, shutters: Ventilation rate during hot weather (ach):

8 ( Windows fully open)

Overheating Details: 466.9 58 524.87

Summer ventilation heat loss coefficient: Transmission heat loss coefficient: Summer heat loss coefficient:

(P1) (P2)

Overhangs: Orientation:

Ratio:

Z_overhangs:

South (Front) North (Rear) West (Side) North (RL) West (RL)

0 0 0 0 0

1 1 1 1 1

Orientation:

Z blinds:

Solar access:

Overhangs:

Z summer:

South (Front) North (Rear) West (Side) North (RL) West (RL)

1 1 1 1 1

0.9 0.9 0.9 1 1

1 1 1 1 1

0.9 0.9 0.9 1 1

Solar shading:

(P8) (P8) (P8) (P8) (P8)

Solar gains: Orientation (calculation for July) South (Front) 0.9 x North (Rear) 0.9 x West (Side) 0.9 x 1x 1x

Area 2.55 7.35 1.9 0.5 1.9

Flux 110.52 85.34 117.78 85.34 204

g_ 0.76 0.76 0.76 0.76 0.76

FF 0.7 0.7 0.7 0.7 0.7

Shading 0.9 0.9 0.9 1 1 Total

Gains 121.45 270.31 96.44 20.43 185.58 694.21 (P3/P4)

July 398.2 1092.4 2.08 17.8

August 406.62 1002.06 (P5) (P6) 1.91 17.8

Internal gains:

Internal gains Total summer gains Summer gain/loss ratio Mean summer external temperature (Thames valley)

Stroma FSAP 2009 Version: 1.5.0.79 (SAP 9.90) - http://www.stroma.com

June 415.01 1149.6 2.19 15.4

Page 1 of 2

SAP 2009 Overheating Assessment Thermal mass temperature increment Threshold temperature Likelihood of high internal temperature

1.3 18.89 Not significant

Assessment of likelihood of high internal temperature:

Slight

Stroma FSAP 2009 Version: 1.5.0.79 (SAP 9.90) - http://www.stroma.com

1.3 21.18 Slight

1.3 21.01 Slight

(P7)

Page 2 of 2

Predicted Energy Assessment F07 Dwelling type: Top floor Maisonette 80 Woodcote Valley Road Date of assessment: 27 August 2014 Purley Produced by: Mark Heptonstall Croydon Total floor area: 73.67 m² CR8 3BE This is a Predicted Energy Assessment for a property which is not yet complete. It includes a predicted energy rating which might not represent the final energy rating of the property on completion. Once the property is completed, an Energy Performance Certificate is required providing information about the energy performance of the completed property. Energy performance has been assessed using the SAP 2009 methodology and is rated in terms of the energy use per square metre of floor area, energy efficiency based on fuel costs and environmental impact based on carbon dioxide (CO2) emissions.

Energy Efficiency Rating

The energy efficiency rating is a measure of the overall efficiency of a home. The higher the rating the more energy efficient the home is and the lower the fuel bills are likely to be.

Environmental Impact (CO2) Rating

The environmental impact rating is a measure of a home’s impact on the environment in terms of carbonn dioxide (CO2) emissions. The higher the rating the less impact it has on the environment.