Home
Add Document
Sign In
Create An Account
SACE Tmax T1N-D/PV UL
Download PDF
Comment
Report
9 Downloads
206 Views
Doc. N.° 1SDH000777R0003 - L9260
SACE Tmax T1N-D/PV UL
Connessione per Jumper Tmax T1N-D/PV UL Jumper connection Tmax T1N-D/PV UL
connection A T1N-D/PV-A grounded system wiring 4PS Kit
Upper supply
3
3
1
Lower supply
3
3
1
connection B T1N-D/PV-B ungrounded system wiring 2PS+2PS Kit
Upper supply
1
2
1
2
1
Lower supply
1
2
1
2
1
A
B
X
X
Y
X
X
CLACK
Y
Y
OFF
ON
TRIPPED
55 2.17"
200
Y
7.87"
200 7.87"
1 x 3 AWG (40°C) 1 x 1/0 AWG (50°C)
Busbar Jumper Kit T1N-D/PV-A for connection A grounded system wiring 4PS, lower supply
Busbar Jumper Kit T1N-D/PV-B for connection B ungrounded system wiring 2PS+2PS, lower supply
D
LOAD
LOAD
Connection A 4PS FCCu
Connection B 2PS+2PS FCCu
Availability for Lower supply
2PS+2PS LOWER SUPPLY
14 0.55" 36 1.42"
130 5.12"
25.7 1.01"
4 0.16"
65 2.56"
46.1 1.82"
Y
65 2.56"
4PS LOWER SUPPLY
36 1.42"
4 0.16"
100 3.94"
25.7 1.01"
X
X
130 5.12"
14 0.55" 36 1.42"
Availability for Lower supply
46.1 1.82"
36 1.42"
LOAD
100 3.94"
C
X
X
7Nm
7Nm
62 lb·in
62 lb·in
25 25 25 0.98" 0.98" 38.1 0.98" 1.5" 101.2 3.98"
11.2 0.44"
25 25 25 0.98" 0.98" 0.98" Y 38.1 1.5"
71 2.8" (see fig.H)
50 1.97" 103 4.06"
Connection B 2PS+2PS
Availability for Upper supply* FCCu
4PS UPPER SUPPLY
11.2 0.44" 71 2.8" (see fig.H)
Busbar Jumper Kit T1N-D/PV-B for connection B ungrounded system wiring 2PS+2PS, upper supply
F
Connection A 4PS
Availability for Upper supply*
25 0.98"
101.2 3.98"
103 4.06"
Busbar Jumper Kit T1N-D/PV-A for connection A grounded system wiring 4PS, upper supply
E
1 0.04"
100 3.94"
1 0.04" 25 0.98"
FCCu
LOAD
LOAD
LOAD
2PS+2PS UPPER SUPPLY
* Terminals configurations must be symmetrical with respect to x-x CB axis when CB is supplied from the top.
G Le uniche configurazioni utilizzabili sono quelle riportate in questo documento The configurations here represented are the only ones available
Tmax T1N-D/PV UL| ABB
H 12.5 0.49"
Ø 4.5 (M4) Ø 0.18"
A WITHOUT FLANGE SENZA MOSTRINA (mm)
53.5 2.11"
Y
B
C
D
E
80
78.2
47
18
39.1
72
103.2
47
18
39.1
3.08"
1.85"
0.71"
1.54"
103.2
1.85"
0.71"
1.54"
WITHOUT FLANGE 3,14" SENZA MOSTRINA 2.83" (inch)
X
107 4.21"
X B E
Y
50 1.97"
X
D
12.5 0.49"
C
Y
X Y A
min 16 mm min 0.63"
I 14 AWG...1/0 AWG = 7 Nm / 62 lb in
Cu Stranded
1,1 Nm 10 lb·in
MIN 14 AWG MAX 1/0 AWG CABLE SECTION:
required Cu wires (number x section)
ambient T 40°C (UL489) In (A) 1 x 3 AWG 100
Jumper example
Label that indicates type of jumper kit installed on breaker 7 Nm 62 lb·in
www.abb.com © Copyright 2011-2014 ABB. All rights reserved.
50°C (UL489B) 1 x 1/0 AWG
Recommend Documents
SACE Tmax XT UL
SACE Tmax XT UL
SACE Tmax T6N/PV UL
SACE Tmax
SACE Tmax
SACE Tmax XT
SACE Tmax XT
SACE Tmax XT
SACE Tmax XT
SACE Emax 2 - Tmax XT
×
Report SACE Tmax T1N-D/PV UL
Your name
Email
Reason
-Select Reason-
Pornographic
Defamatory
Illegal/Unlawful
Spam
Other Terms Of Service Violation
File a copyright complaint
Description
×
Sign In
Email
Password
Remember me
Forgot password?
Sign In
Login with Facebook
Our partners will collect data and use cookies for ad personalization and measurement.
Learn how we and our ad partner Google, collect and use data
.
Agree & Close