sf4c series - Panasonic Industrial Devices

Report 0 Downloads 76 Views
577 FIBER SENSORS

Ultra-slim Safety Light Curtain

SF4C SERIES Related Information

LASER SENSORS

Type 4

■■General terms and conditions.............. F-3 ■■SF-C13.......................................... P.663~ ■■General precautions...................... P.1595

■■Selection guide.............................. P.457~ ■■Glossary of terms........................ P.1549~ ■■Korea’s S-mark.............................. P.1602

PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS

Certified

AREA SENSORS

Conforming to OSHA / ANSI

Certified by NRTL

SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS

Certified [SF4C-H□(J-05) only]

PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS

Category 4 PLe SIL3

The control category differs depending on the configuration and wiring of the external circuit.

Machine safeguarding without sacrificing productivity Slim size for efficient applications Available work space is expanded from the previous model, and productivity is improved.

FA COMPONENTS

UV CURING SYSTEMS

BSF4-AH80

SF4C series

Previous

Usable work space

Usable work space

83 % (414 mm 16.299 in)

Selection Guide Safety Light Curtains Safety Control Units Safety Components

SF4C

If the machine opening is 500 mm 19.685 in

Thinness 13 mm 0.512 in

MACHINE VISION SYSTEMS

SF4D SF4B/ SF4B-G SF4B-C

panasonic.net/id/pidsx/global

43 mm 1.693 in

95 % (474 mm 18.661 in approx.)

Usable work space approx.

12 % UP (60 mm 2.362 in)

43 mm 1.693 in

13.2 mm 0.520 in

If the machine opening width is 500 mm 19.685 in

Shorter safety distance to downsize equipment The safety distance of SF4C series finger protection type is 84 mm 3.307 in shorter than that of SF4C series hard protection type (SF4C-H□). As a result, the depth and guard of the equipment can be downsized.

13.2 mm 0.520 in

If the machine opening width is 500 mm 19.685 in

Finger protection type 102 mm 4.016 in

Shortened by

84 mm 3.307 in

18 mm 0.709 in 100 mm 3.937 in min. *

SF2B SF2C Definition of Sensing Heights

SF4C series

Safety distance Safety distance

Hand protection type Finger protection type

102 mm 4.016 in 18 mm 0.709 in

Shortened by

84 mm 3.307 in

Calculation based on ISO 41 ms or longer being machinery’s stopping time. ** C alculation based on13855 ISO with 13855 with 41 ms or the longer beingmaximum the machinery's maximum stopping time. Hand protection type

Finger protection type

Safety distance which is dependent on the safety light curtain

Safety distance which is dependent on the maximum shutdown time of equipment

* The safety light curtain cannot be installed within a distance of 100 mm 3.937 in. (ISO 13855)

Ultra-slim Safety Light Curtain Type 4

SF4C SERIES

Can be used in a variety of applications for simplified equipment [Large multi-purpose indicator] The bright LED indicators located in the center of both sides of each safety light curtain can be illuminated by using external inputs. There is no need for setting up a separate indicator, so that equipment is consolidated.

Green

Red

PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS

External input device (Lighting / blinking signal) Large multi-purpose indicator

Input 1 Input 2

●Solid green

Equipment is operating

Use as an error indicator

Use as a muting lamp

present

SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS

SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS

Normal



AREA SENSORS

PARTICULAR USE SENSORS

●Blinking red Error

WIRE-SAVING SYSTEMS

Normal Solid red Emergency stop

FIBER SENSORS LASER SENSORS

Green / Red

* The lighting conditions of SF4C series can be changed by using a handy-controller SFC-HC (optional). It is possible to actuate the lighting together with internal operation, regardless of connection of the large multi-purpose indicator input wires.

Use as an operation indicator

578

MEASUREMENT SENSORS

Error blinking Confirm detail of error quickly on the digital display.

* The photo is SF4C-H□. SF4C-F□ differs in the position of digital display.

Use the handy-controller SFC-HC (optional) to change lighting conditions.

* If a failure diagnosis of muting lamp is needed as by the result of risk assessment, use the handy-controller SFC-HC (optional) to change the setting, and connect the muting lamp output wire (red) of this safety light curtain to an incandescent lamp separately.

STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES

Beam-axis alignment indicators help to reduce startup time

ENERGY MANAGEMENT SOLUTIONS

The beam channels of the safety light curtain are displayed in four blocks so that incident light position is shown at a glance. When the beam channel at the bottommost channel (or topmost channel), which is used as a reference for beam-axis alignments, is correctly aligned, the LED blinks red. After this, each block lights red as the beam axes successively become aligned. When all channel beam axes are aligned, all LEDs light green. The display also has a stability indicator (STB) added so that setup can be carried out with greater stability.

FA COMPONENTS

Beam-axis alignment indicator

MACHINE VISION SYSTEMS UV CURING SYSTEMS

A single model supports both PNP and NPN polarities reducing model numbers PNP transistor output and NPN transistor output are combined in a single model. Overseas equipment that uses PNP, replacement with NPN sensors, factories that are positively grounded, and transfer of equipment overseas are all situations where the control circuits for a single model are suitable for use worldwide.

Lightweight! The SF4C series is made of resin that is approx. 45 % lighter than the conventional aluminum case type. Its lightweight body eases the burden on the mounting surface of the equipment and contributes to overall reduced weight during equipment transportation or overseas shipment. * Except the cable part

IP67 protection structure An IP67 (IEC) rating is achieved even in an ultra-slim resin body by using a laser welding method.

A fast response time for all models SF4C-H□: 7 ms*, SF4C-F□: 9 ms* The SF4C series reduces the safety distance as well as the calculation work required for the safety distance among models with different beam channels. * When connecting safety sensors (safety light curtains, etc) to the safety input,the response time will be the total time of connected units.

Mutual interference is reduced without needing for interference prevention lines The ELCA (Extraneous Light Check & Avoid) function automatically shifts the scan timing in order to avoid interference.

Material suitable for manufacturing a secondary battery Mounting bracket: SUS304

SF4C body is made of resin and the mounting bracket is made of Stainless Steel Mounting screw: SUSXM7* (SUS), so materials used are limited. Suitable for Body case: manufacturing secondary Polycarbonate alloy batteries or for food production equipment. * Effective from production in November 2010.

Reducing the number of malfunctions caused by extraneous light Double scanning method and retry processing are effective in eliminating the effects of extraneous light.

Selection Guide Safety Light Curtains Safety Control Units Safety Components

SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights

579 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS

Ultra-slim Safety Light Curtain Type 4

Handy-controller SFC-HC (Opitonal) enables the user to select a variety of settings

Operation of large multi-purpose indicators (factory setting: mode 0)

Large Mode Large Control outputs multi-purpose multi-purpose No. indicator 1 indicator 2 (OSSD 1 / OSSD 2) OFF High or Low High or Low ON 0 Lights up in red Lights up in green 1 Blinks in red Blinks in green 2 Lights up in red Blinks in green 3 Blinks in red Lights up in green 4 (Note 1) Lights up in red Blinks in red 5 (Note 1) Blinks in green Lights up in green 6 (Note 1) Lights up in green Lights up in red 7 (Note 1) Lights up in red Blinks in red -

Muting function

Override function

Valid

Valid

Blinks in green Lights up in green Blinks in green

Lockout blinking function

When lockout occurs

Valid

Blinks in red

Description Negative logic of the control outputs (OSSD 1, OSSD 2) (factory setting)

1

Positive logic of the control outputs (OSSD 1, OSSD 2)

PLC

2

For test input enabled: output OFF, For Disabled: output ON

3

For test input enabled: output ON, For Disabled: output OFF

HUMAN MACHINE INTERFACES

4

For unstable incident beam: OFF (Note 1)

ENERGY MANAGEMENT SOLUTIONS

5

For unstable incident beam: ON (Note 1)

6

For muting: ON

7

For muting: OFF

8

For beam received: ON, For beam interrupted: OFF (Note 2)

Selection Guide Safety Light Curtains Safety Control Units Safety Components

SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights

9

For beam received: OFF, For beam interrupted: ON (Note 2)

A

For safety input enabled: ON, Disabled: OFF

B

For safety input enabled: OFF, Disabled: ON

C

For lockout: OFF

D

For lockout: ON

1, 2 or 3 non-specified beam channels can be deactivated. This function is useful in the event when an object passes through the safety light curtain’s sensing area.

Notes: 1) The output cannot be used while the fix blanking function, floating blanking function or the muting function is activated. 2) This device outputs the beam received/interrupted state under activating the auxiliary output switching function using the handy-controller irrespective of activating other functions, fixed blanking function, floating blanking function, and muting function. Note: When the floating blanking function is used, the size of the min. sensing object is changed.

Safety, productivity, and cost reduction [Muting control function] The safety light curtain has a built-in muting control function that causes the line to stop only when a person passes through the safety light curtain, and does not stop the line when an object passes through. The muting sensors and muting lamps can be connected directly to the safety light curtain. Furthermore, the large multi-purpose indicators can be used as muting lamps, which contribute to less wiring troubles, improvement of safety and productivity, and cost reduction.

Muting lamps

Previous

UV CURING SYSTEMS

Floating blanking function which allows non-specified beam channels to be deactivated improves productivity

Muting sensors Safety circuit (Safety relay, etc.)

Safety light curtain

SF4C series

MACHINE VISION SYSTEMS

The SF4C series is equipped with a fixed blanking function which allows specific beam channels to be selectively interrupted without causing the control output (OSSD) to output the OFF signal. This function is convenient for use with applications in which certain fixed obstacles tend to interrupt specific beam channels.

Auxiliary output has selectable output configuration 0

FA COMPONENTS

Fixed blanking function which allows selective beam channels to be activated improves productivity

Invalid

Mode No.

LASER MARKERS

SFC-HC

Notes: 1) Blinking takes precedence in case of same color brinks or light up. Notes: 2) During lockout, it is possible to blink in red.

WIRE-SAVING SYSTEMS

STATIC CONTROL DEVICES

HC

Operation of the large multi-purpose indicators can be configured

SIMPLE WIRE-SAVING UNITS

MEASUREMENT SENSORS

SF4C SERIES

Muting lamps

Muting unit

Muting sensors Safety circuit (Safety relay, etc.)

SF4C series

* If a failure diagnosis of muting lamp is needed as by the result of risk assessment, use the handy-controller SFC-HC (optional) to change the setting, and connect the muting lamp output wire (red) of this safety light curtain to an incandescent lamp separately.

Ultra-slim Safety Light Curtain Type 4

SF4C SERIES

HC

Selective muting area [Separate muting control function for each beam channel] The handy-controller SFC-HC (optional) can be used to carry out muting control for specified beam channels only. Because individual beam channel can be specified to suit the object, separate guards to prevent entry do not need to be set up.

While muting control is active (line operating)

Line stopped

580 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS

For example, depending on the height of the object, the muting function can be activated for 10 beam channels starting from the bottom most, so that if the 11th or subsequent beam channels are interrupted, it is judged that a person has entered the area and the line stops.

HC

Safety measures when objects exit [Exit muting control function] Muting at the exit of a machine is now possible using the handy-controller SFC-HC (optional). Just set a Max. four sec. delay timer on the muting sensors located at the exit. This is efficient for places with no installation space for muting sensors and also reduces cost and wiring.

SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS

Entrance side

WIRE-SAVING SYSTEMS MEASUREMENT SENSORS

Exit side

STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS

Muting sensors are not needed on the exit side!

FA COMPONENTS

By installing muting sensors only within the dangerous zone and setting up a delay timer on the sensor, muting control is made possible even on the exit side where muting sensors cannot be installed.

MACHINE VISION SYSTEMS UV CURING SYSTEMS

Reset input

Safety light curtain

SF4C series

The safety light curtain has a built-in external device monitoring function (such as deposited relay monitoring) and an interlock function. This allows a safety circuit to be constructed so that a separate safety relay unit is not needed, and the control box has become smaller to help to achieve to lower costs.

Previous

Safety circuit is constructed without the need for a safety relay unit [External device monitoring function] Monitoring

Safety relay unit

Safety relays

Motor, etc.

Reset input

SF4C series

Monitoring

Safety relays

Motor, etc.

The safety light curtain can directly connect to external devices (safety relay, etc) without an exclusive control unit. This allows for simplified equipment, cost reduction, and error prevention.

Selection Guide Safety Light Curtains Safety Control Units Safety Components

SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights

581 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS

Ultra-slim Safety Light Curtain Type 4

SF4C SERIES

Industry first*! Wire-saving when connecting to safety devices [Safety input function] Contact outputs such as an emergency stop switches or a safety door switches can be connected to the safety light curtain. Also, by using the handy-controller SFC-HC (optional) up to three sets of safety light curtains can be cascade connected for a consolidated safety output. * As of March 2009, in-company survey

Direct connection of safety devices

Safety door switch, emergency stop switch, etc.

SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS

SF4C series

Previous

SENSOR OPTIONS

Monitoring

Safety door switch, emergency stop switch, etc.

2NC

Monitoring

2NC

MEASUREMENT SENSORS

PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS

SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights

SF4C series

Contactor

Safety relays

Motor, etc.

Direct connection of various safety devices is possible for a simplified safety circuit.

By using the handy-controller SFC-HC (optional) up to three sets of safety light curtains can be cascade connected for a consolidated safety output. (Note) SF4C series

Previous Monitoring

Safety door switch, emergency stop switch, etc. 2NC

Monitoring

Monitoring Selection Guide Safety Light Curtains Safety Control Units Safety Components

Motor, etc.

A safety relay unit is needed for connecting safety devices other than safety light curtain.

MACHINE VISION SYSTEMS UV CURING SYSTEMS

Contactor

Safety relay unit

Contactor

Motor, etc.

Two safety relays are needed

Safety light curtain for each set of safety light curtain

Three sets of safety light curtains require three sets of safety relays.

2NC

HC

Safety door switch, emergency stop switch, etc.

Just two safety relays are enough

Monitoring

LASER MARKERS

Safety light curtain Safety relays Safety relay unit

Individual monitoring by auxiliary output

STATIC CONTROL DEVICES

SF4C series

Contactor

Motor, etc.

Outputs of safety devices are consolidated in one unit.

Individual monitoring on safety light curtains is possible while the outputs of three sets of safety light curtains and other safety devices are consolidated in one unit.

Note: This setting is possible with the use of handy-controller SFC-HC (optional) for SF4C series Ver.2.1 or later.

Ultra-slim Safety Light Curtain Type 4

SF4C SERIES

582

PRODUCT CONFIGURATION

FIBER SENSORS

Maintenance is prioritized Pigtailed type (with mounting bracket, connector attached cable)

Basic set in one model No. Cable type [Mounting bracket, with 5 m (16.404 ft) cable] Standard mounting bracket MS-SFC-1 (Accessory)

Standard mounting bracket MS-SFC-1 (Accessory)

1

AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS

3 Cable 5 m 16.404 ft (discrete wire)

Connector attached cable 0.5 m 1.640 ft

SENSOR OPTIONS

1 2 Safety light curtains

Min. sensing object ø14 mm ø0.551 in (10 mm 0.394 in beam pitch)

10 mm 0.394 in

Protective height

0.1 to 3 m 0.328 to 9.843 ft

Beam pitch 10 mm 10 mm 0.394 in 0.394 in Beam channel No.

Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch)

Finger protection type Hand protection type

Operating range (Note 1)

Appearance Beam channel No.

10 mm 0.394 in

Protective height

0.1 to 3 m 0.328 to 9.843 ft Beam pitch 10 mm 20 mm 0.394 in 0.787 in Actual operating range 0.1 m of the safety light curtain 0.328 ft Setting range of the receiver

3m 9.843 ft

Number of beam 2 Cable type channels

Model No. (Note 2)

1 Pigtailed type

Protective height (mm in)

SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS

SF4C-F15-J05

SF4C-F15

15

160 mm 6.299 in

SF4C-F23-J05

SF4C-F23

23

240 mm 9.449 in

MEASUREMENT SENSORS

SF4C-F31-J05

SF4C-F31

31

320 mm 12.598 in

STATIC CONTROL DEVICES

SF4C-F39-J05

SF4C-F39

39

400 mm 15.748 in

LASER MARKERS

SF4C-F47-J05

SF4C-F47

47

480 mm 18.898 in

SF4C-F55-J05

SF4C-F55

55

560 mm 22.047 in

SF4C-F63-J05

SF4C-F63

63

640 mm 25.197 in

SF4C-H8-J05

SF4C-H8

8

160 mm 6.299 in

ENERGY MANAGEMENT SOLUTIONS

SF4C-H12-J05

SF4C-H12

12

240 mm 9.449 in

FA COMPONENTS

SF4C-H16-J05

SF4C-H16

16

320 mm 12.598 in

MACHINE VISION SYSTEMS

SF4C-H20-J05

SF4C-H20

20

400 mm 15.748 in

SF4C-H24-J05

SF4C-H24

24

480 mm 18.898 in

UV CURING SYSTEMS

SF4C-H28-J05

SF4C-H28

28

560 mm 22.047 in

SF4C-H32-J05

SF4C-H32

32

640 mm 25.197 in

Notes: 1) The operating range is the possible setting distance between the emitter and the receiver. Receiver cannot be placed in this range

INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS

ORDER GUIDE

Type

PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS

2

4

LASER SENSORS

2) The  model No. with suffix “E” shown on the label affixed to the product is the emitter, “D” shown on the label is the receiver.

PLC HUMAN MACHINE INTERFACES

Selection Guide Safety Light Curtains Safety Control Units Safety Components

SF4D Emitter

Receiver

SF4B/ SF4B-G

Receiver

SF4B-C

3 4 Mating cables Appearance

For receiver For emitter

3 With connectors on both ends

4

Mating cables

W  ith connector on one end

Type

SF4C

Model No.

Description

SFB-CC10-MU

Length: 3 m 9.843 ft Cable with connector on one end for pigtailed type Net weight: 430 g approx. (2 cables) Two cables per set for emitter and receiver Length: 7 m 22.966 ft Cable color: Gray (for emitter), Gray with black line (for receiver) Net weight: 1,000 g approx. (2 cables) Length: 10 m 32.808 ft Connector color: Gray (for emitter), Black (for receiver) Net weight: 1,300 g approx. (2 cables) The min. bending radius: R6 mm R0.236 in

SFB-CCJ3E-MU

Length: 3 m 9.843 ft Net weight: 190 g approx. (1 cable)

SFB-CC3-MU SFB-CC7-MU

10 m 32.808 ft Cable with connectors on both ends for pigtailed type SFB-CCJ10E-MU Length: Net weight: 660 g approx. (1 cable) Cable color: Gray (for emitter), Gray with black line (for receiver)

SFB-CCJ3D-MU

Connector color: Gray (for emitter), Black (for receiver) Length: 3 m 9.843 ft Net weight: 210 g approx. (1 cable) The min. bending radius: R6 mm R0.236 in

10 m 32.808 ft SFB-CCJ10D-MU Length: Net weight: 680 g approx. (1 cable)

BSF4-AH80 SF2B SF2C Definition of Sensing Heights

583 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS

Ultra-slim Safety Light Curtain Type 4

SF4C SERIES

ORDER GUIDE Spare parts (Accessories for safety light curtain) Designation

Model No.

Standard mounting bracket

Description

• MS-SFC-1

Standard mounting bracket

MS-SFC-1

Allows the safety light curtain to be mounted at the rear with one M5 hexagon-socket-head bolt. Mounting direction of the bracket can be selected between vertical or horizontal (no dead zone). (4 pcs. per set for emitter and receiver)

Test rod ø14

SF4C-TR14

Min. sensing object for regular checking (ø14 mm ø0.551 in)

Test rod ø25

SF4C-TR25

Min. sensing object for regular checking (ø25 mm ø0.984 in)

Safety light curtain

M5 hexagonsocket-head bolt Purchase separately. Four bracket set Four M3 (length: 4 mm 0.157 in) countersunk screws

<Mountable in three directions>

PARTICULAR USE SENSORS

Safety light curtain

SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS

Standard mounting bracket MS-SFC-1 (Accessory)

WIRE-SAVING SYSTEMS MEASUREMENT SENSORS

M3 (length: 4 mm 0.157 in) countersunk screw with loose-proof agent

STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS

Selection Guide Safety Light Curtains Safety Control Units Safety Components

SF4D SF4B/ SF4B-G

OPTIONS Mounting brackets Designation

Description

NA2-N compatible mounting bracket

MS-SFC-2

Used when changing over area sensor NA2-N series to the SF4C series. The mounting holes of NA2-N series can continue to be used. Center mounting by a M6 hexagon-socket-head bolt is also possible. (4 pcs. per set for emitter and receiver)

Versatile bracket

MS-SFC-3

Two ways of mounting are possible. 1 Rear mounting which enables beam adjustment 2 Dead zoneless center mounting on aluminum frame (4 pcs. per set for emitter and receiver)

MS-SFC-4

Used to support the safety light curtain in the middle. Be sure to purchase it when using the versatile bracket MS-SFC-3(optional) on SF4C-F55(-J05), SF4C-F63(-J05), SF4C-H28(-J05) or SF4C-H32(-J05). (2 pcs. per set for emitter and receiver)

Intermediate supporting bracket for versatile bracket

Versatile bracket

BSF4-AH80 SF2B SF2C Definition of Sensing Heights

• MS-SFC-2

• MS-SFC-4

Mounting holes for M4 screw Mounting hole for M6 hexagon-sockethead bolt

Mounting holes for M4 screw

Mounting hole for M6 hexagon-sockethead bolt M4 screw Purchase separately.

Safety light curtain

Intermediate supporting bracket for versatile bracket

• MS-SFC-3

SF4B-C SF4C

NA2-N compatible mounting bracket

Model No.

Mounting hole for M6 hexagon-sockethead bolt

Mounting holes for M4 screw

Mounting hole for M6 hexagon-sockethead bolt (Mount on either one)

Ultra-slim Safety Light Curtain Type 4

SF4C SERIES

OPTIONS

FIBER SENSORS LASER SENSORS

Control unit Designation

Appearance

Model No.

Slim type control unit

PHOTOELECTRIC SENSORS

Description

MICRO PHOTOELECTRIC SENSORS

Use a discrete wire cable to connect to the safety light curtain. Relay output. Compatible with up to Control Category 4.

SF-C13

AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS

●Recommended safety relay Panasonic Corporation SF relay, slim type SF relay, slim type SFS3-L-DC24V (AG1S132) SFS4-L-DC24V (AG1S142)

Item

DIN terminal block SFS4-SFD (AG1S847)[4-poles type] SFS6-SFD (AG1S867)[6-poles type]

Note: Contact Panasonic Corporation for details on the recommended products.

Type Model No. Part No.

With LED indicator SFS3-L-DC24V SFS4-L-DC24V AG1S132 AG1S142

Contact arrangement Rated nominal switching capacity Min. switching capacity Coil rating Rated power consumption Operation time Release time

3a1b

4a2b

6 A / 250 V AC, 6 A / 30 V DC 1 mA / 5 V DC 20.8 mA / 24 V DC 15 mA / 24 V DC

Ambient temperature Applicable standards

360 mW

500 mW

20 ms or less 20 ms or less –40 to +85 °C –40 to +185 °F (Humidity: 5 to 85 % RH) UL/c-UL, TÜV, Korea's S-mark

Appearance

Wire-saving Y-shaped connector

Model No.

SFC-WY1

Cable with connector on one side

Description Wire-saving connector for SF4C-F□-J05 and SF4C-H□-J05. Cables of emitter and receiver are consolidated into one cable for wire-saving. Wiring has +24 V, 0 V, OSSD 1, OSSD 2, output polarity setting wire (shield), large multi-purpose indicator input 1, and large multi-purpose indicator input 2 only. Net weight: 40 g approx. Power wire and synchronization wire are connected inside the connector. Interlock is disabled (automatic reset).

WY1-CCN3

Cable length: 3 m 9.843 ft Net weight: 200 g approx. (1 cable)

WY1-CCN10

Cable length: 10 m 32.808 ft Net weight: 620 g approx. (1 cable)

Mating cable for Y-shaped connector Cable color: Gray (with black line) Connector color: Black The min. bending radius: R6 mm R0.236 in Connector outer diameter: ø14 mm ø0.551 in max.

PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS

A total of 24 wires

Y-shaped connector

HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS

Selection Guide Safety Light Curtains

By using the Y-shaped connector, the least required wires such as power or safety output are consolidated into one cable. Man-hours taken for wiring is eliminated to the minimum. Construction times as well as wiring mistakes are greatly reduced. Previous

INDUCTIVE PROXIMITY SENSORS

PLC

Y-shaped connectors Type

584

Only 7 wires Less wiring mistakes! Reduced wiring time! Easy wiring to Safety PLC, etc.

Safety Control Units Safety Components

SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C

SF4C series Pig tailed type

SF4C series Cable type Safety PLC / Remote I/O / Safety relay unit / SF-C13, etc.

Safety PLC / Remote I/O / Safety relay unit / SF-C13, etc.

Definition of Sensing Heights

585 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS

Ultra-slim Safety Light Curtain Type 4

OPTIONS Product configuration Emitter Receiver ・

MICRO PHOTOELECTRIC SENSORS

PRESSURE / FLOW SENSORS

Extension cable

Extension cable (1 cable for receiver) SFB-CCJ3D-MU (3 m 9.843 ft for receiver) SFB-CCJ10D-MU (10 m 32.808 ft for receiver)

AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS

SF4C SERIES

Pigtailed type 0.5 m 1.640 ft

Extension cable (1 cable for emitter)

INDUCTIVE PROXIMITY SENSORS

SFB-CCJ3E-MU (3 m 9.843 ft for emitter) SFB-CCJ10E-MU (10 m 32.808 ft for emitter)

PARTICULAR USE SENSORS

SFB-CCJ3D (3 m 9.843 ft) SFB-CCJ10D (10 m 32.808 ft)

Y-shaped connector SFC-WY1

Cable with connector on one side (Common for all models) WY1-CCN3 (3 m 9.843 ft) WY1-CCN10 (10 m 32.808 ft)

SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS

Connector pin layout Black connector

WIRE-SAVING SYSTEMS MEASUREMENT SENSORS

2

Connector pin No.

1 8

3

Receiver

7

STATIC CONTROL DEVICES

Emitter

6

4 5

Gray connector

LASER MARKERS PLC

Description

1

OSSD 2

2

+24 V

3

OSSD 1

4

Not used

5

Large multi-purpose indicator input 1

6

Large multi-purpose indicator input 2

7

0V

8

Output polarity setting wire (Shield)

HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS

Wiring diagram of control unit SF-C13



• Connect the safety light curtain control outputs OSSD 1 and OSSD 2 to S1 and S2 respectively.

• Connect the safety light curtain control outputs OSSD 1 and OSSD 2 to S4 and S2 respectively and ground the + side.

UV CURING SYSTEMS

Selection Guide Safety Light Curtains

Y-shaped connector

WY1-CCN□

+24 V DC

+24 V DC

Not used (Yellow-green)

+24 V (Brown)

Safety Components

0V (Blue)

SF4D

Not used (Yellow-green)

+24 V (Brown)

Large multi-purpose indicator input 1 (Gray)

Large multi-purpose indicator input 2 (Gray / Black)

Output polarity setting wire (Shield)

PLC, etc.

A1

S1

BSF4-AH80 Ui

OSSD 1 (Black)

L1

RESET (Note 1) (Note 1) FUSE1 FUSE2 (Note 2) S2 S3 S4 X1 X2 X3 13 23 33 41

F

SF2B

PLC, etc.

OSSD 2 (White)

OSSD 2 (White)

SF4B-C

Large multi-purpose indicator input 2 (Gray / Black)

Output polarity setting wire 0 V (Shield) (Blue)

OSSD 1 (Black)

SF4B/ SF4B-G

F.G.

K1

S1

S2 S3 S4

X1

X2

F Ui

A2 0V

INTER_LOCK

AUX KA, KB: Force-guided relay F.G. or magnet contactor

KA N

FUSE2 33 41

K1

RESET (Note 1) (Note 2)

K2

FAULT 14 24

X3 13 23

SF-C13 control circuit

K2 OUT

L1 (Note 1) FUSE1

A1

SF-C13 control circuit

SF2C Definition of Sensing Heights

Y-shaped connector

WY1-CCN□

Large multi-purpose indicator input 1 (Gray)

Safety Control Units

SF4C

Safety light curtain (SF4C-F□-J05 and SF4C-H□-J05)

Safety light curtain (SF4C-F□-J05 and SF4C-H□-J05)

34 42

L1L2L3

KB

OUT

KB KA

M 3~

Notes: 1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. 3) Unused wires must be insulated.

A2 0V

INTER_LOCK

FAULT

14 24 34 42 AUX KA, KB: Force-guided relay KB or magnet contactor KA N

L1L2L3

KB KA

M 3~

Notes: 1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. 3) Unused wires must be insulated.

Ultra-slim Safety Light Curtain Type 4

SF4C SERIES

OPTIONS

FIBER SENSORS

Handy-controller

LASER SENSORS

Pigtailed type Appearance

Model No. Mating cable

Handycontroller

Fixe d Floa blan ting king Aux blan Lighiliary king cont emoutp trol issi ut on

Co de Mo nito Pro r Co tect py

FU

NC TIO

N

SFC-HC

CEL

ENTER

TE R

Handy-controller

Cable type +V 0 V

Cable set for cable type connection

Synchronization – Synchronization +

Not used

FUNCTION

CANCEL

Terminal block

ENTER

Handy-controller

SF4C-F□

Designation

SAFETY LIGHT CURTAINS / SAFETY COMPONENTS

INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS

Metal protection case Applicable beam channels

MICRO PHOTOELECTRIC SENSORS

PRESSURE / FLOW SENSORS

Cable set

Control circuit

SFC-WNC1

PHOTOELECTRIC SENSORS

AREA SENSORS

FUNCTION

CANCEL

CAN

EN

Control circuit

Designation

586

Metal protection case (2 pcs. per set for emitter and receiver)

SF4C-H□

Model No.

15

8

MS-SFCH-8

23

12

MS-SFCH-12

31

16

MS-SFCH-16

39

20

MS-SFCH-20

47

24

MS-SFCH-24

55

28

MS-SFCH-28

63

32

MS-SFCH-32

• MS-SFCH-8

• MS-SFCH-12/16/20/24/28/32

SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES

Introduction to Panasonic Industrial Devices SUNX sensors that can be used as muting sensors Compact Photoelectric Sensor

CX-400 SERIES Ver.2

Ultra-slim Photoelectric Sensor

EX-10 SERIES Ver.2

U-shaped Micro Photoelectric Sensor

PM-25/45/65  SERIES

Rectangular-shaped Inductive Proximity Sensor

GX-F/H SERIES

ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS

• World standard size • Wide variation

• 3.5 mm 0.138 in thickness • Long sensing range: 1 m 3.281 ft (thru-beam type: EX-19) * The EX-20 series that is compatible with M3 mounting screws is also available.

P.245~

P.279~

• Three protection circuits standard on all models • Ample beam emitting / receiving distance of 6 mm 0.236 in

• Easy to mount with M3 screws

P.395~

• Industry longest in stable sensing range • 10 times the durability (Compared to previous models) • IP68G rating

Selection Guide Safety Light Curtains Safety Control Units Safety Components

P.785~ SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights

587

Ultra-slim Safety Light Curtain Type 4

SPECIFICATIONS

FIBER SENSORS

MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS

SF4C-F□

Item

Model No.

PHOTOELECTRIC SENSORS

Safety light curtain individual specifications

No. of beam channels Protective height Large multipurpose indicator lights off Large multipurpose indicator lights up PFHD MTTFD Net weight Pigtailed Total of type emitter and Cable type receiver

( )

LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS

Selection Guide Safety Light Curtains Safety Control Units Safety Components

SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights

Model No.

Item

Type Pigtailed type Cable type

No. of beam channels Protective height Large multipurpose indicator lights off Large multipurpose indicator lights up PFHD MTTFD Net weight Pigtailed Total of type emitter and Cable type receiver

Current consumption

STATIC CONTROL DEVICES

15 160 mm 6.299 in

Min. sensing object ø14 mm ø0.551 in type (10 mm 0.394 in beam pitch) SF4C-F23-J05 SF4C-F31-J05 SF4C-F39-J05 SF4C-F47-J05 SF4C-F55-J05 SF4C-F23 SF4C-F31 SF4C-F39 SF4C-F47 SF4C-F55

SF4C-F63-J05 SF4C-F63

23 31 39 47 55 63 240 mm 9.449 in 320 mm 12.598 in 400 mm 15.748 in 480 mm 18.898 in 560 mm 22.047 in 640 mm 25.197 in

Emitter: 70 mA or less Receiver: 80 mA or less

Emitter: 75 mA or less Receiver: 85 mA or less

Emitter: 80 mA or less Receiver: 90 mA or less

Emitter: 85 mA or less Receiver: 95 mA or less

Emitter: 105 mA or less Receiver: 110 mA or less

Emitter: 110 mA or less Receiver: 115 mA or less

Emitter: 115 mA or less Receiver: 120 mA or less

Emitter: 120 mA or less Receiver: 125 mA or less

2.29 × 10–9

2.73 × 10–9

3.18 × 10–9

3.62 × 10–9 100 years or more

4.06 × 10–9

4.50 × 10–9

4.95 × 10–9

210 g approx.

270 g approx.

340 g approx.

400 g approx.

470 g approx.

540 g approx.

600 g approx.

600 g approx.

670 g approx.

730 g approx.

800 g approx.

860 g approx.

930 g approx.

1,000 g approx.

SF4C-H□

WIRE-SAVING SYSTEMS MEASUREMENT SENSORS

Type Pigtailed type SF4C-F15-J05 SF4C-F15 Cable type

Current consumption

LASER SENSORS

SF4C SERIES

( )

SF4C-H8-J05 SF4C-H8

Min. sensing object ø25 mm ø0.984 in type (20 mm 0.787 in beam pitch) SF4C-H12-J05 SF4C-H16-J05 SF4C-H20-J05 SF4C-H24-J05 SF4C-H28-J05 SF4C-H32-J05 SF4C-H12 SF4C-H16 SF4C-H20 SF4C-H24 SF4C-H28 SF4C-H32

8 160 mm 6.299 in

12 16 20 24 28 32 240 mm 9.449 in 320 mm 12.598 in 400 mm 15.748 in 480 mm 18.898 in 560 mm 22.047 in 640 mm 25.197 in

Emitter: 70 mA or less Receiver: 85 mA or less

Emitter: 70 mA or less Receiver: 90 mA or less

Emitter: 75 mA or less Receiver: 95 mA or less

Emitter: 80 mA or less Receiver: 100 mA or less

Emitter: 120 mA or less Receiver: 135 mA or less

Emitter: 120 mA or less Receiver: 140 mA or less

Emitter: 120 mA or less Receiver: 145 mA or less

Emitter: 120 mA or less Receiver: 150 mA or less

1.66 × 10–9

1.90 × 10–9

2.10 × 10–9

2.33 × 10–9 100 years or more

2.54 × 10–9

2.77 × 10–9

2.98 × 10–9

240 g approx.

300 g approx.

360 g approx.

420 g approx.

490 g approx.

550 g approx.

610 g approx.

630 g approx.

700 g approx.

760 g approx.

820 g approx.

880 g approx.

950 g approx.

1,000 g approx.

Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. PFHD: Probability of dangerous failure per hour, MTTFD: Mean time to dangerous failure (in years)

Ultra-slim Safety Light Curtain Type 4

SF4C SERIES

SPECIFICATIONS

FIBER SENSORS

Safety light curtain common specifications Type Applicable standards

Item

Model No.

International standard Japan Europe (EU) (Note 2) North America (Note 3)

Pigtailed type SF4C-F□-J05

Supply voltage

SF4C-H□-J05

SF4C-F□

SF4C-H□

ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 Machinery Directive, EMC Directive, RoHS Directive

Operating range (Note 4) Min. sensing object (Note 5) Effective aperture angle

LASER SENSORS

Cable type

IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3) JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3) EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2

CE marking directive compliance Beam pitch

0.1 to 3 m 0.328 to 9.843 ft 10 mm 0.394 in

20 mm 0.787 in

10 mm 0.394 in

20 mm 0.787 in

ø14 mm ø0.551 in opaque object ø25 mm ø0.984 in opaque object ø14 mm ø0.551 in opaque object ø25 mm ø0.984 in opaque object ±2.5° or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] 24 V DC +10 –15 % Ripple P-P 10 % or less

PNP open-collector transistor / NPN open-collector transistor (switching method)

Control outputs (OSSD 1, OSSD 2)

Operation mode Protection circuit Response time

Auxiliary output (Non-safety output)

<When selecting PNP output> • Max. source current: 200 mA • Applied voltage: same as supply voltage (between the control output and +V) • Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) • Leakage current: 200 µA or less (including power supply OFF condition) • Max. load capacity: 1 µF (No load to Max. source current) • Load wiring resistance: 3 Ω or less

<When selecting NPN output> • Max. sink current: 200 mA • Applied voltage: same as supply voltage (between the control output and 0 V) • Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) • Leakage current: 200 µA or less (including power supply OFF condition) • Max. load capacity: 1 µF (No load to Max. sink current) • Load wiring resistance: 3 Ω or less

ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)(Note 6,7) Incorporated OFF response: 9 ms or less, OFF response: 7 ms or less, OFF response: 9 ms or less, ON response: 90 ms or less ON response: 90 ms or less ON response: 90 ms or less PNP open-collector transistor / NPN open-collector transistor (switching method) <When selecting PNP output> • Max. source current: 100 mA • Applied voltage: same as supply voltage(between the auxiliary source and +V) • Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)

OFF response: 7 ms or less, ON response: 90 ms or less

<When selecting NPN output> • Max. sink current: 100 mA • Applied voltage: same as supply voltage(between the auxiliary sink and 0 V) • Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)

Operation mode OFF when control outputs are ON, ON when control outputs are OFF [Factory setting, operating mode can be changed using the handy-controller SFC-HC(optional).] Protection circuit Incorporated ELCA function Incorporated (reducing mutual interference automatically) Test / reset input function Incorporated Interlock function Incorporated [Manual reset / Automatic reset (Note 8)] External device monitoring function Incorporated Safety input function Incorporated (safety contact) Muting function / Override function Incorporated Optional functions (Note 9)

Environmental resistance

Pollution degree Operating altitude Degree of protection Ambient temperature Ambient humidity Ambient illuminance Dielectric strength voltage Insulation resistance Vibration resistance Shock resistance Emitting element Material Cable Cable extension Accessories

588

Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting 3 2,000 m 6,561 68 ft or less (Note 10) IP67 / IP65 (IEC) –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +60 °C –13 to +140 °F 30 to 85 % RH, Storage: 30 to 85 % RH Incandescent light: 5,000 ℓx or less at the light-receiving face 1,000 V AC for one min. between all supply terminals connected together and enclosure 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each Infrared LED (Peak emission wavelength: 855 nm 0.034 mil) Enclosure: Polycarbonate alloy, Sensing surface: Polycarbonate alloy, MS-SFC-1 (Standard mounting bracket): SUS 0.15 mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long 0.15 mm2 (power line: 0.2 mm2) 8-core heat-resistant PVC cable, 5 m 16.404 ft long Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver optional mating cables

Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable (Note 11) (Note 12)

MS-SFC-1 (Standard mounting bracket): 1 set, MS-SFC-1 (Standard mounting bracket): 1 set, MS-SFC-1 (Standard mounting bracket): 1 set, MS-SFC-1 (Standard mounting bracket): 1 set, SF4C-TR14 (Test rod): 1 No. SF4C-TR25 (Test rod): 1 No. SF4C-TR14 (Test rod): 1 No. SF4C-TR25 (Test rod): 1 No.

Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. 3) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards. 4) The operating range is the possible setting distance between the emitter and the receiver. 5) When the floating blanking function is used, the size of the min. sensing object is changed. 6) The outputs are not “OFF” when muting function is active even if the beam channel is interruped. 7) In case the blanking function is valid, the operation mode is changed. 8) The manual reset and automatic reset are possible to be switched depending on the wiring status. 9) In case of using optional function, the handy-controller SFC-HC (optional) is required. 10) D  o not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. 11) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver). 12) When the synchronization + wire (orange) and synchronization - wire (orange / black) is extended with a cable other than exclusive cable, use a 0.2 mm2 or more shielded twisted pair cable.

PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS

Selection Guide Safety Light Curtains Safety Control Units Safety Components

SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights

589

LASER SENSORS PHOTOELECTRIC SENSORS

SPECIFICATIONS Control unit Model No.

Item

MICRO PHOTOELECTRIC SENSORS

Connectable safety light curtains

AREA SENSORS

Applicable standards

SAFETY LIGHT CURTAINS / SAFETY COMPONENTS

CE marking directive compliance

PRESSURE / FLOW SENSORS

Supply voltage / Current consumption

INDUCTIVE PROXIMITY SENSORS

WIRE-SAVING SYSTEMS

LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS

24 V DC ± 10 % Ripple P-P 10 % or less / 100 mA or less (without safety light curtain) NO contact × 3 (13-14, 23-24, 33-34)

Application category Rated operation voltage (Ue) / Rated operation current (le) Contact resistance Contact protection fuse rated Pick-up delay (Auto reset / Manual reset) Response time (Recovery time) Auxiliary output

AC-15, DC-13 (IEC 60947-5-1) 30 V DC / 4 A, 230 V AC / 4 A, resistive load (For inductive load, during contact protection). Min applicable load: 10 mA (at 24 V DC) (Note 2) 100 mΩ or less (initial value) 4 A (slow blow) 80 ms or less / 90 ms or less 10 ms or less Safety relay contact (NC contact) × 1 (41-42) (Related to safety output)

Rated operation voltage / current Contact protection fuse rated Semiconductor auxiliary output (AUX) Output operation Excess voltage category Polarity selection function Pollution degree Environmental resistance

STATIC CONTROL DEVICES

Machinery Directive, Low Voltage Directive, EMC Directive, RoHS Directive

Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down

Safety output

MEASUREMENT SENSORS

Safety light curtain manufactured by Panasonic Industrial Devices SUNX

ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards

Fuse (power supply)

SENSOR OPTIONS

SF-C13 EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496-1 (Type 4), ISO 13849-1 (Category 4, PLe), JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4), ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2)

Control category

PARTICULAR USE SENSORS

SIMPLE WIRE-SAVING UNITS

SF4C SERIES

24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) 2 A (slow blow) PNP open-collector transistor • Max. source current: 60 mA On when the safety light curtain is interrupted II Incorporated (Cable connection allows selection of plus/minus ground) Minus ground: Correspond to PNP output safety light curtain Plus ground: Correspond to NPN output safety light curtain 2

Protection

Enclosure: IP40, Terminal IP20

Ambient temperature Ambient humidity Vibration resistance

Enclosure material

–10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F 30 to 85 % RH, Storage: 30 to 95 % RH Resistance/malfunction 10 to 55 Hz frequency, 0.35 mm 0.014 in double amplitude in X, Y, and Z directions twenty times each ABS

Weight

Net weight: 200 g approx.

Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F 2) If several SF-C13 units are being used in line together, leave a space of 5 mm 0.197 in or more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs at right. 3) Refer to p.667 for details of the specifications for SF-C13.

Selection Guide Safety Light Curtains

Dilating when SF-C13 units are mounted close together 6 Rated operation current (A)

FIBER SENSORS

Ultra-slim Safety Light Curtain Type 4

5 4 3 2

Safety Control Units

1

Safety Components

0 32

SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights

Handy-controller  Item

Model No.

Supply voltage Current consumption Communication method Digital display Function indicators Functions Environmental resistance

SF4D

Ambient temperature Ambient humidity Voltage withstandability Insulation resistance

35 40 45 50 55 95 104 113 122 131 Ambient temperature (°C °F)

SFC-HC 24 V DC +10 –15 % Ripple P-P 10 % or less (common to safety light curtain power supply) 65 mA or less RS-485 two-way communications (Specific procedure) 4-digit red LED display × 2 (Selected beam channels, setting contents etc. are displayed.) Green LED × 9 (Set function is displayed.) Fixed blanking / Floating blanking / Auxiliary output change / Satety input setting change / Large multi-purpose indicator setting change / Muting setting change / Interlock setting change / External device monitoring setting change / Override setting changing function 60 sec. / Protecting –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F 30 to 85 % RH, Storage: 30 to 85 % RH 1,000 V AC for one min. between all supply terminals connected together and enclosure 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure

Cable

12-core shielded cable, 0.5 m 1.640 ft long, with a connector at the end (2 cables)

Weight

Net weight: 200 g approx.

Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.

Ultra-slim Safety Light Curtain Type 4

SF4C SERIES

590

I/O CIRCUIT AND WIRING DIAGRAMS

FIBER SENSORS

I/O circuit diagram

I/O circuit diagram

LASER SENSORS





PHOTOELECTRIC SENSORS

Terminal No. of pigtailed type Color code

Emitter

Terminal No. of pigtailed type Color code

Emitter

(Brown) +V

(Brown) +V

(Pink) Test input / 470 Ω Reset input

6.8 kΩ

(Pale purple) 470 Ω Interlock setting input *S2

0.47 μF

6.8 kΩ 470 Ω (Yellow) Override input *S2

6.8 kΩ

3 kΩ 3 kΩ

(Gray) Safety input 1

24 V DC +10 –15 %

(Gray / Black) Safety input 2

Internal circuit

Receiver

(Yellow) Override input

WIRE-SAVING SYSTEMS

(Orange) Synchronization +

(Orange / Black) Synchronization –

(Orange / Black) Synchronization – Internal circuit

Receiver

MEASUREMENT SENSORS STATIC CONTROL DEVICES

Users’ circuit

LASER MARKERS

(Orange / Black) Synchronization –

PLC

47 kΩ 470 Ω

(Gray) Large multi*S2 purpose indicator input 1

(Shield) Output polarity setting wire (Black) Control output 1 (OSSD 1)

470 Ω

(Gray / Black) Large multi- *S2 purpose indicator input 2

470 Ω

(Sky-blue / White) Muting input 1

*S2

470 Ω

(Sky-blue / Black) Muting input 2

*S2

470 Ω

(Yellow-green) External device monitoring input

47 kΩ

6.8 kΩ

6.8 kΩ 6.8 kΩ

ENERGY MANAGEMENT SOLUTIONS

K2

(White) Control output 2 (OSSD 2)

6.8 kΩ 470 Ω (Yellow-green) External device monitoring input 0.47 μF

6.8 kΩ 47 kΩ 0.1 μF

47 kΩ

(Blue) 0 V K1, K2: External device (Force-guided relay or magnet contactor) Users’ circuit

* S1, S2

47 kΩ 6.8 kΩ 0.1 μF

K1

K2

(Gray) Large multi470 Ω purpose indicator input 1

(Sky-blue / White) 470 Ω Muting input 1

*S2

6.8 kΩ (Sky-blue / Black) 470 Ω Muting input 2

*S2

6.8 kΩ 0.1 μF

UV CURING SYSTEMS

*S2

47 kΩ (Gray / Black) Large multi- *S2 470 Ω purpose indicator input 2

6.8 kΩ Internal circuit

K1 K2

Selection Guide Safety Light Curtains Safety Control Units

(Blue) 0 V K1, K2: External device (Force-guided relay or magnet contactor) Users’ circuit

* S1, S2

Switch S1 • Test input / Reset input For manual reset Vs to Vs – 3.5 V (sink current 5 mA or less): OFF (Note) Open: ON

Switch S1 • Test input / Reset input For manual reset 0 to +2.5 V (source current 5 mA or less): OFF Open: ON

For automatic reset Vs to Vs – 3.5 V (sink current 5 mA or less): ON (Note) Open: OFF

For automatic reset 0 to +2.5 V (source current 5 mA or less): OFF Open: ON

Switch S2 • Interlock setting input, Override input, Muting input 1/2, Large multi-purpose indicator input 1/2, Vs to Vs – 3.5 V (sink current 5 mA or less): Valid (Note) Open: Invalid

FA COMPONENTS MACHINE VISION SYSTEMS

0.1 μF

Note: Vs is the applying supply voltage.

K1

(White) Control output 2 (OSSD 2)

K2

(Black) Control output 1 (OSSD 1)

Internal circuit

HUMAN MACHINE INTERFACES

K1

6.8 kΩ

(Shield) Output polarity setting wire

SIMPLE WIRE-SAVING UNITS

*S2

6.8 kΩ

(Orange) Synchronization +

Users’ circuit

INDUCTIVE PROXIMITY SENSORS

SENSOR OPTIONS

(Blue) 0 V

Sensor circuit

Sensor circuit

6.8 kΩ

PRESSURE / FLOW SENSORS

PARTICULAR USE SENSORS

*S2

(Brown) +V

47 kΩ

0.47 μF

(Pink) Test input / Reset input

6.8 kΩ (Pale purple) 470 Ω Interlock setting input

24 V DC %

+10 –15

*S1

(Orange) Synchronization +

6.8 kΩ 0.1 μF

(Gray / Black) Safety input 2

(Brown) +V

6.8 kΩ 0.1 μF

3 kΩ

(Orange) Synchronization +

47 kΩ

0.1 μF

(Gray) Safety input 1

470 Ω

0.47 μF

Load

+ –

3 kΩ

470 Ω 6.8 kΩ

6.8 kΩ

(Orange / Black) Synchronization –

0.1 μF

6.8 kΩ 0.47 μF

0.47 μF

(Yellow-green / Black) Auxiliary output (Blue) 0 V

SAFETY LIGHT CURTAINS / SAFETY COMPONENTS

(Red) Muting lamp output

+ –

(Shield) Output polarity setting wire

AREA SENSORS

Load

(Yellow-green / Black) Auxiliary output

(Red) Muting lamp output

Sensor circuit

0.47 μF

*S1

6.8 kΩ 6.8 kΩ

6.8 kΩ

(Shield) Output polarity setting wire

Sensor circuit

0.47 μF

MICRO PHOTOELECTRIC SENSORS

Switch S2 • Interlock setting input, Override input, Muting input 1/2, Large multi-purpose indicator input 1/2, 0 to +2.5 V (source current 5 mA or less): Valid Open: Invalid

Safety Components

SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights

591 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS

Ultra-slim Safety Light Curtain Type 4

I/O CIRCUIT AND WIRING DIAGRAMS Connection example Basic wiring: Min. operation only This is the general configuration using one set of the emitter and receiver facing each other. The control outputs (OSSD 1 / OSSD 2) turn OFF if the light is interrupted, while they automatically turn ON if receive the light. The auxiliary output is used to invalid the external device monitoring function. The auxiliary output cannot be connected to external devices. Receiver

Emitter

PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS

Selection Guide Safety Light Curtains Safety Control Units Safety Components

SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights

SF4C SERIES

Gray cable Gray cable (with black line)

(Red) Muting lamp output (Yellow) Override input (Pale purple) Interlock setting input (Brown) +V (Pink) Test input / Reset input (Gray) Safety input 1 (Gray / Black) Safety input 2 (Shield) Output polarity setting wire (Blue) 0 V (Yellow-green / Black) Auxiliary output (Orange) Synchronization + (Orange / Black) Synchronization – (Orange / Black) Synchronization – (Orange) Synchronization + (Yellow-green) External device monitoring input (Brown) +V (Black) Control output 1 (OSSD 1) K1 (White) Control output 2 (OSSD 2) K2 (Shield) Output polarity setting wire (Blue) 0 V (Sky-blue / White) Muting input 1 (Sky-blue / Black) Muting input 2 (Gray) Large multi-purpose indicator input 1 (Gray / Black) Large multi-purpose indicator input 2

Open Open Open

Receiver

+ –

Emitter

24 V DC %

+10 –15

Gray cable Gray cable (with black line)

Open Open Open Open K1, K2: Force-guided relay or magnet contactor

Interlock function External device monitoring function Auxiliary output Output polarity setting wire Safety input

Disabled (Automatic reset) Disabled Not used PNP Invalid

PRECAUTIONS FOR PROPER USE • When this device is used in the “PSDI mode”, an appropriate control circuit must be configured between this device and the machinery. For details, be sure to refer to the standards or regulations applicable in each region or country. • This catalog is a guide to select a suitable product. Be sure to read instruction manual prior to its use. • Both emitter and receiver are adjusted before shipment, please apply both emitter and receiver with the same serial No. The serial No. is indicated on the plates of both emitter and receiver. (Indicated under model No.) • Make sure to carry out the test run before regular operation. • Do not install this safety light curtain with a machine whose operation cannot be stopped immediately in the middle of an operation cycle by an emergency stop equipment.

(Red) Muting lamp output (Yellow) Override input (Pale purple) Interlock setting input (Brown) +V (Shield) Output polarity setting wire (Gray) Safety input 1 (Gray / Black) Safety input 2 (Pink) Test input / Reset input (Blue) 0 V (Yellow-green / Black) Auxiliary output (Orange) Synchronization + (Orange / Black) Synchronization – (Orange / Black) Synchronization – (Orange) Synchronization + (Yellow-green) External device monitoring input (Brown) +V (Black) Control output 1 (OSSD 1) K1 (White) Control output 2 (OSSD 2) K2 (Shield) Output polarity setting wire (Blue) 0 V (Sky-blue / White) Muting input 1 (Sky-blue / Black) Muting input 2 (Gray) Large multi-purpose indicator input 1 (Gray / Black) Large multi-purpose indicator input 2

Open Open Open

+ –

24 V DC %

+10 –15

Open Open Open Open K1, K2: Force-guided relay or magnet contactor

Interlock function External device monitoring function Auxiliary output Output polarity setting wire Safety input

Disabled (Automatic reset) Disabled Not used NPN Invalid

Refer to the instruction manual for details. The instruction manual can be download from our website.

Others • This device has been developed / produced for industrial use only. • Do not use during the initial transient time (2 sec.) after the power supply is switched on. • Avoid dust, dirt and steam. • Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. • Take care that the sensor is not directly exposed to fluorescent lamp from a rapid-starter lamp or a high frequency lighting device, as it may affect the sensing performance. Handy-controller This safety light curtain enables to set each function using the handy-controller SFC-HC (optional). Among the functions, the contents related to the safety distance such as the size of the minimum sensing object and response time are varied depending on the setting condition. When setting each function, re-calculate the safety distance, and make enough space larger than the calculated safety distance. Failure to do so might cause the accident that the device cannot stop quickly before reaching the dangerous area of the machinery, resulting in the serious injury or death. • Refer to the instruction manual of the handy-controller for details of the function settings for using handycontroller SFC-HC (optional).

SF4C SERIES

Ultra-slim Safety Light Curtain Type 4



DIMENSIONS (Unit: mm in)

592

The CAD data can be downloaded from our website.・

SF4C-F□ SF4C-H□

Safety light curtain

Mounting drawing for the safety light curtains using the standard mounting brackets MS-SFC-1 (accessory). 7.7 (0.303 )

30 1.181

10 0.394

5.4 0.213

(

)

18 0.709 Indicator part (Note)

DCB A

5.4 0.213

(

)

18 0.709 Indicator part (Note)

13 0.512

13.2 0.520 t 2 t 0.079

21 0.827

7.7 (0.303 )

30 1.181

12 0.472 Indicator part (Note)

13 0.512

21 (0.827 )

50.5 (1.988 )

50.5 (1.988 )

50.5 (1.988 )

88 (3.465 )

DCB A

88 (3.465 )

Large Multi-purpose indicator

Large Multi-purpose indicator

Beam pitch

Beam pitch

F

F

G Gray cable

16 10 0.630 0.394

Emitter

88 (3.465 )

Large Multi-purpose indicator

E

(

88 3.465

Large Multi-purpose indicator

)

13.2 0.520 t 2 t 0.079

21 0.827

13 0.512

18 (0.709 )

21 (0.827 )

Large Multi-purpose indicator

16 10 0.630 0.394

7.7 (0.303 )

30 1.181

21 (0.827 )

88 (3.465 )

MICRO PHOTOELECTRIC SENSORS

13.2 0.520 t 2 t 0.079 10 0.394

Beam pitch

18 (0.709 )

Gray cable (with black line)

10 0.394 Gray cable

Receiver

Emitter

7.7 (0.303 )

12 0.472 Indicator part (Note)

50.5 (1.988 )

88 (3.465 )

BA

Large Multi-purpose indicator

E

88 (3.465 )

Large Multi-purpose indicator

Beam pitch

F

G

30 1.181

13.2 0.520 t 2 t 0.079

13 0.512

88 (3.465 )

Large Multi-purpose indicator

SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS

PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS

F 10 0.394

G

AREA SENSORS

INDUCTIVE PROXIMITY SENSORS

21 0.827

AB

LASER SENSORS PHOTOELECTRIC SENSORS

Mounting bracket assembly dimensions

FIBER SENSORS

G Gray cable (with black line)

STATIC CONTROL DEVICES LASER MARKERS

Receiver PLC HUMAN MACHINE INTERFACES

Connector of the pigtailed type SF4C-F□-J05 / SF4C-H□-J05 45 (1.772 )

FA COMPONENTS ø15.6 ø0.614

ø6 ø0.236

Model No.

A

B

C

D

E

Model No.

ENERGY MANAGEMENT SOLUTIONS

MACHINE VISION SYSTEMS UV CURING SYSTEMS

F

G Selection Guide

SF4C-F15(-J05)

SF4C-H8(-J05)

140 5.512 160 6.299 172 6.772 184 7.244 130 5.118

SF4C-F□(-J05) 10 0.394

SF4C-F23(-J05)

SF4C-H12(-J05) 220 8.661 240 9.449 252 9.921 264 10.394 210 8.268

SF4C-H□(-J05) 20 0.787

SF4C-F31(-J05)

SF4C-H16(-J05) 300 11.811 320 12.598 332 13.071 344 13.543 290 11.417

Safety Control Units

SF4C-F39(-J05)

SF4C-H20(-J05) 380 14.961 400 15.748 412 16.220 424 16.693 370 14.567

Safety Components

SF4C-F47(-J05)

SF4C-H24(-J05) 460 18.110 480 18.898 492 19.370 504 19.842 450 17.717

SF4C-F55(-J05)

SF4C-H28(-J05) 540 21.260 560 22.047 572 22.520 584 22.992 530 20.866

SF4C-F63(-J05)

SF4C-H32(-J05) 620 24.409 640 25.197 652 25.669 664 26.142 610 24.016

Note: Measurement of drawing above is display section of SF4C-H□. In case of SF4C-F□, the position of digital error indicator (red) is different as lower figure. Also, digital error indicator (red) is not incorporated in SF4C-F15□ (-J05).

<SF4C-H□> <SF4C-F□>

ø5 ø0.197

Safety Light Curtains

SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights

Digital error indicator

593

Ultra-slim Safety Light Curtain Type 4



DIMENSIONS (Unit: mm in)

FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS

SF4C SERIES

The CAD data can be downloaded from our website.・

SF4C-F□ SF4C-H□

Safety light curtain

Mounting bracket assembly dimensions

MICRO PHOTOELECTRIC SENSORS

Mounting drawing for the safety light curtains using the versatile brackets MS-SFC-C3 (optional) and intermediate supporting bracket for versatile brackets MS-SFC-F4 (optional).

AREA SENSORS





( )

( )

7.5 0.295

SAFETY LIGHT CURTAINS / SAFETY COMPONENTS

2 0.079

15 ( 0.591 )

PRESSURE / FLOW SENSORS

7.5 0.295

MS-SFC-3

Large Multi-purpose indicator

PARTICULAR USE SENSORS SENSOR OPTIONS

PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS

D A C

6.5 0.256

Large Multi-purpose indicator

WIRE-SAVING SYSTEMS

LASER MARKERS

8 0.315

B

21 0.827

12.7 0.500

15 ( 0.591 ) 7.5 ( 0.295 )

6.5 0.256 2 0.079

25.7 1.012

30 1.181 42 1.654

Emitter Model No.

SF4C-F23(-J05)

SF4C-H12(-J05)



SF4C-F31(-J05)

SF4C-H16(-J05)



SF4C-F39(-J05)

SF4C-H20(-J05)



SF4C-F47(-J05)

SF4C-H24(-J05)



SF4C-F55(-J05)

SF4C-H28(-J05)

Available

SF4C-F63(-J05)

SF4C-H32(-J05)

Available

SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights

12.7 0.500

(22 0.866)

Large Multipurpose indicator

8 0.315

Large Multipurpose indicator MS-SFC-4

D

MS-SFC-4

6.5 0.256 2 0.079

25.7 1.012

Inter mediate supporting bracket

MACHINE VISION SYSTEMS

Safety Components

MS-SFC-3

Large Multipurpose indicator

30 1.181

6.5 0.256 8 0.315 21 0.827

6.5 0.256

Large Multi-purpose indicator

MS-SFC-4 A’ 6.5 0.256

D

A’

B’

B’ (22 0.866) 30 1.181 42 1.654

2 0.079 12.7 0.500 25.7 1.021

42 1.654

Receiver



Safety Control Units

21 0.827

15 ( 0.591 ) 7.5 ( 0.295 )

SF4C-H8(-J05)

Safety Light Curtains

MS-SFC-3

(22 0.866) 30 1.181 42 1.654

SF4C-F15(-J05)

Selection Guide

2 0.079 6.5 0.256

Large Multi-purpose indicator

6.5 0.256

B

FA COMPONENTS

UV CURING SYSTEMS

MS-SFC-3

Large Multi-purpose indicator MS-SFC-4

D A C

SIMPLE WIRE-SAVING UNITS

STATIC CONTROL DEVICES

15 ( 0.591 )

(22 0.866)

INDUCTIVE PROXIMITY SENSORS

MEASUREMENT SENSORS

6.5 0.256

Emitter

12.7 0.500 25.7 1.021

Receiver

A

A'

B

B'

C

D

175 6.890 255 10.039 335 13.189 415 16.339 495 19.488 575 22.638 655 25.787

116 4.567 196 7.717 276 10.866 356 14.016 436 17.165 516 20.315 596 23.465





















238 to 338 9.370 to 13.307 278 to 378 10.945 to 14.882

209 to 309 8.228 to 12.165 249 to 349 9.803 to 13.740

190 7.480 270 10.630 350 13.780 430 16.929 510 20.079 590 23.228 670 26.378

160 6.299 240 9.449 320 12.598 400 15.748 480 18.898 560 22.047 640 25.197

Note: Be sure to mount MS-SFC-4 when using SF4C-F55(-J05), SF4C-F63(-J05), SF4C-H28(-J05) and SF4C-H32(-J05).

8 0.315 21 0.827

6.5 0.256 2 0.079

Ultra-slim Safety Light Curtain Type 4



DIMENSIONS (Unit: mm in) MS-SFC-1

MS-SFC-2

NA2-N compatible mounting bracket (Optional)

30 1.181

t2 t 0.079

6 0.236

10 0.394

7.5 0.295 5 0.197

21 34 0.827 1.339

37 1.457 22.5 0.886

Mounting hole for M3 countersunk screw (for main body mounting)

Versatile bracket (Optional)

(

6 0.236

5 0.197

6.5 0.256

(

)

13 (0.512 )

)

3 0.118

LASER MARKERS

14.5 0.571

t1.5 t0.059

M3 countersunk screw mounting hole (for main body mounting) (3 0.118)

(3 0.118)

PLC HUMAN MACHINE INTERFACES

(6 0.236)

7.5 0.295

21.5 0.846

22.5 37 0.886 1.457

M3 countersunk screw mounting hole (for main body mounting)

(13 0.512)

5 0.197 2 0.079 18 0.709 30 1.181

t2 t0.079

Material: Stainless steel (SUS304) Net weight: 75 g approx. (4 pcs.) Package weight: 90 g appox.

7 0.276

6.5 0.256

MEASUREMENT SENSORS STATIC CONTROL DEVICES



30 1.181 18 0.709 2 0.079

INDUCTIVE PROXIMITY SENSORS

WIRE-SAVING SYSTEMS

MS-SFC-3

14.5 0.571

PRESSURE / FLOW SENSORS

SIMPLE WIRE-SAVING UNITS

Four bracket set Four M3 (length 4 mm 0.157 in) countersunk screws are attached.



SAFETY LIGHT CURTAINS / SAFETY COMPONENTS

SENSOR OPTIONS

Material: Stainless steel (SUS304) Net weight: 36 g approx. (4 pcs.) Package weight: 40 g appox.

Four bracket set Four M3 (length 4 mm 0.157 in) countersunk screws are attached.

AREA SENSORS

PARTICULAR USE SENSORS

Mounting hole for M3 countersunk screw (for main body mounting)

Material: Stainless steel (SUS304) Net weight: 32 g approx. (4 pcs.) Package weight: 35 g appox.

LASER SENSORS

MICRO PHOTOELECTRIC SENSORS

18 0.709 2 0.079

14.8 6.5 0.583 0.256

FIBER SENSORS

PHOTOELECTRIC SENSORS

30 1.181

2 × ø4.5 ø0.177

11.8 5.4 0.465 0.213

2-ø4.5 ø0.177

594

The CAD data can be downloaded from our website.・

Standard mounting bracket (Accessory)

t2 t 0.079

SF4C SERIES

2-ø4.5 ø0.177

23 0.906 t1.5 t0.059

t2 t0.079

ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS

Four bracket set Four M3 (length 4 mm 0.157 in) countersunk screws are attached.

MS-SFC-4

Intermediate supporting bracket for versatile bracket (Optional) 43.5 1.713

27.3 1.075

Safety Components

10.5 0.413

13.6 ( 0.535 )

SF4D

9.7 0.382 t2 t0.079

Safety Light Curtains Safety Control Units

27 1.063 (31 1.220)

Selection Guide

SF4B/ SF4B-G 8 0.315

SF4B-C

6 0.236

SF4C 6.5 0.256

6.5 0.256

10 0.394 20 25 0.787 0.984

BSF4-AH80 SF2B SF2C

Material: Stainless steel (SUS304) Net weight: 40 g approx. (2 pcs.) Package weight: 60 g appox. Two bracket set

27 1.063 37 1.457

3 ( 0.118 )

Definition of Sensing Heights

595 ・

FIBER SENSORS LASER SENSORS

Ultra-slim Safety Light Curtain Type 4

SF4C SERIES

DIMENSIONS (Unit: mm in)

The CAD data can be downloaded from our website.・

MS-SFCH-□

Metal protection case (Optional)

PHOTOELECTRIC SENSORS

Assembly dimensions Mounting drawing for the safety light curtains using the metal protection case (MS-SFCH-□).

MICRO PHOTOELECTRIC SENSORS AREA SENSORS

18 0.709

ø6.4 ø0.252 (M6 mounting hole)

SAFETY LIGHT CURTAINS / SAFETY COMPONENTS

36.2 1.425

(When using MS-SFC-2) ø5.4 ø0.213 (M5 mounting hole)

PRESSURE / FLOW SENSORS

Indicator part

PARTICULAR USE SENSORS

26 1.024

SENSOR OPTIONS

10 0.394 3 0.118

SIMPLE WIRE-SAVING UNITS

90 3.543

WIRE-SAVING SYSTEMS

STATIC CONTROL DEVICES

43.5 1.713

E

96 3.780 43.5 1.713

6 0.236

8 0.315

F

LASER MARKERS

26 1.024

HUMAN MACHINE INTERFACES

(When using MS-SFC-2)

MS-SFCH-8 MS-SFCH-12

Safety Control Units

MS-SFCH-16 MS-SFCH-20

SF4D

MS-SFCH-24

SF4B/ SF4B-G

MS-SFCH-28

BSF4-AH80 SF2B SF2C Definition of Sensing Heights

MS-SFCH-32

A

ø5.4 ø0.213 (M5 mounting hole)

4-ø4.8 ø0.189 (M4 mounting hole) (When using MS-SFC-2)

18 0.709

t2.3 t0.091

Safety Light Curtains

D

(When using MS-SFC-1)

Material: Aluminum

Model No.

SF4C

A

36.2 1.425

MACHINE VISION SYSTEMS

SF4B-C

B

26 1.024

FA COMPONENTS

Safety Components

C

5 0.197

5 0.197

ø6.4 ø0.252 (M6 mounting hole)

19.6 0.772

ENERGY MANAGEMENT SOLUTIONS

Selection Guide

D

ø5.4 ø0.213 (M5 mounting hole) (When using MS-SFC-1)

PLC

UV CURING SYSTEMS

ø5.4 ø0.213 (M5 mounting hole) (When using MS-SFC-1)

(When using MS-SFC-1)

INDUCTIVE PROXIMITY SENSORS

MEASUREMENT SENSORS

19.6 0.772

A

B

C

D

E

F

Net weight (2 pcs.)

190 7.480 270 10.630 350 13.780 430 16.929 510 20.079 590 23.228 670 26.378

180 7.087 260 10.236 340 13.386 420 16.535 500 19.685 580 22.835 660 25.984

175 6.890 255 10.039 335 13.189 415 16.339 495 19.488 575 22.638 655 25.787

172 6.772 252 9.921 332 13.071 412 16.220 492 19.370 572 22.520 652 25.669

162 6.378 242 9.528 322 12.677 402 15.827 482 18.976 562 22.126 642 25.276

26 1.024 35 1.378 35 1.378 35 1.378 35 1.378 35 1.378 35 1.378

160 g approx. 240 g approx. 340 g approx. 420 g approx. 520 g approx. 600 g approx. 700 g approx.

Ultra-slim Safety Light Curtain Type 4



DIMENSIONS (Unit: mm in) SFB-CC□-MU

SFB-CCJ□-MU

Mating cable with connectors on both ends (Optional)

45 (1.772 )

L

• Length L

ø6 ø0.236

AREA SENSORS

• Length L

SAFETY LIGHT CURTAINS / SAFETY COMPONENTS

Model No.

Length L

Length L

SFB-CC3-MU

3,000 118.110

SFB-CCJ3D-MU

SFB-CC7-MU

7,000 275.590

SFB-CCJ3E-MU

10,000 393.700

SFB-CCJ10D-MU

SFB-CC10-MU

3,000 118.110

SFB-CCJ10E-MU

SFC-WY1

Y-shaped connector (Optional)

WY1-CCN3 WY1-CCN10

66 2.598

22.5 0.886 13.5 0.531

(

41 1.614

42 1.654

)

10,000 393.700

Mating cable (Optional) L

INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS

SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES

ø6 ø0.236

ø9 ø0.354

PRESSURE / FLOW SENSORS

SENSOR OPTIONS

ø14 ø0.551

ø14 46.6 31 ø0.551 1.835 1.220

LASER SENSORS

MICRO PHOTOELECTRIC SENSORS

ø15.6 ø0.614

ø6 ø0.236

FIBER SENSORS

PHOTOELECTRIC SENSORS

45 (1.772 )

L

ø15.6 ø0.614

ø15.6 ø0.614

Model No.

596

The CAD data can be downloaded from our website.・

Mating cable with connector on one end (Optional) 45 (1.772 )

SF4C SERIES

LASER MARKERS

Model No.

Length L

WY1-CCN3

3,000 118.110

WY1-CCN10

10,000 393.700

PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS

SFC-HC

Handy-controller (Optional) 65 2.559

25.4 1.000

SF-C13

Control unit (Optional)

30 1.181

6.75 0.266

4 0.157 23 0.906

35 1.378 67.3 2.650

ø6 ø0.236 cables, 0.5 m 1.640 ft long

130 5.118

MACHINE VISION SYSTEMS

5 0.197

6 0.236

3 × 5 = 15 3 × 0.197 = 0.591 Selection Guide

91.6 3.606

Safety Light Curtains Safety Control Units

140 5.512 ENTER

UV CURING SYSTEMS

34.5 1.358

FUNCTION

CANCEL

FA COMPONENTS

10 0.394 13.5 0.531

80 3.150 6.5 80.8 0.256 3.181 Suitable for 35 mm 1.378 in width DIN rail

13 0.512

22.5 0.886

5 0.197

Safety Components

SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights