577 FIBER SENSORS
Ultra-slim Safety Light Curtain
SF4C SERIES Related Information
LASER SENSORS
Type 4
■■General terms and conditions.............. F-3 ■■SF-C13.......................................... P.663~ ■■General precautions...................... P.1595
■■Selection guide.............................. P.457~ ■■Glossary of terms........................ P.1549~ ■■Korea’s S-mark.............................. P.1602
PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS
Certified
AREA SENSORS
Conforming to OSHA / ANSI
Certified by NRTL
SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS
Certified [SF4C-H□(J-05) only]
PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS
Category 4 PLe SIL3
The control category differs depending on the configuration and wiring of the external circuit.
Machine safeguarding without sacrificing productivity Slim size for efficient applications Available work space is expanded from the previous model, and productivity is improved.
FA COMPONENTS
UV CURING SYSTEMS
BSF4-AH80
SF4C series
Previous
Usable work space
Usable work space
83 % (414 mm 16.299 in)
Selection Guide Safety Light Curtains Safety Control Units Safety Components
SF4C
If the machine opening is 500 mm 19.685 in
Thinness 13 mm 0.512 in
MACHINE VISION SYSTEMS
SF4D SF4B/ SF4B-G SF4B-C
panasonic.net/id/pidsx/global
43 mm 1.693 in
95 % (474 mm 18.661 in approx.)
Usable work space approx.
12 % UP (60 mm 2.362 in)
43 mm 1.693 in
13.2 mm 0.520 in
If the machine opening width is 500 mm 19.685 in
Shorter safety distance to downsize equipment The safety distance of SF4C series finger protection type is 84 mm 3.307 in shorter than that of SF4C series hard protection type (SF4C-H□). As a result, the depth and guard of the equipment can be downsized.
13.2 mm 0.520 in
If the machine opening width is 500 mm 19.685 in
Finger protection type 102 mm 4.016 in
Shortened by
84 mm 3.307 in
18 mm 0.709 in 100 mm 3.937 in min. *
SF2B SF2C Definition of Sensing Heights
SF4C series
Safety distance Safety distance
Hand protection type Finger protection type
102 mm 4.016 in 18 mm 0.709 in
Shortened by
84 mm 3.307 in
Calculation based on ISO 41 ms or longer being machinery’s stopping time. ** C alculation based on13855 ISO with 13855 with 41 ms or the longer beingmaximum the machinery's maximum stopping time. Hand protection type
Finger protection type
Safety distance which is dependent on the safety light curtain
Safety distance which is dependent on the maximum shutdown time of equipment
* The safety light curtain cannot be installed within a distance of 100 mm 3.937 in. (ISO 13855)
Ultra-slim Safety Light Curtain Type 4
SF4C SERIES
Can be used in a variety of applications for simplified equipment [Large multi-purpose indicator] The bright LED indicators located in the center of both sides of each safety light curtain can be illuminated by using external inputs. There is no need for setting up a separate indicator, so that equipment is consolidated.
Green
Red
PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS
External input device (Lighting / blinking signal) Large multi-purpose indicator
Input 1 Input 2
●Solid green
Equipment is operating
Use as an error indicator
Use as a muting lamp
present
SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS
SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS
Normal
●
AREA SENSORS
PARTICULAR USE SENSORS
●Blinking red Error
WIRE-SAVING SYSTEMS
Normal Solid red Emergency stop
FIBER SENSORS LASER SENSORS
Green / Red
* The lighting conditions of SF4C series can be changed by using a handy-controller SFC-HC (optional). It is possible to actuate the lighting together with internal operation, regardless of connection of the large multi-purpose indicator input wires.
Use as an operation indicator
578
MEASUREMENT SENSORS
Error blinking Confirm detail of error quickly on the digital display.
* The photo is SF4C-H□. SF4C-F□ differs in the position of digital display.
Use the handy-controller SFC-HC (optional) to change lighting conditions.
* If a failure diagnosis of muting lamp is needed as by the result of risk assessment, use the handy-controller SFC-HC (optional) to change the setting, and connect the muting lamp output wire (red) of this safety light curtain to an incandescent lamp separately.
STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES
Beam-axis alignment indicators help to reduce startup time
ENERGY MANAGEMENT SOLUTIONS
The beam channels of the safety light curtain are displayed in four blocks so that incident light position is shown at a glance. When the beam channel at the bottommost channel (or topmost channel), which is used as a reference for beam-axis alignments, is correctly aligned, the LED blinks red. After this, each block lights red as the beam axes successively become aligned. When all channel beam axes are aligned, all LEDs light green. The display also has a stability indicator (STB) added so that setup can be carried out with greater stability.
FA COMPONENTS
Beam-axis alignment indicator
MACHINE VISION SYSTEMS UV CURING SYSTEMS
A single model supports both PNP and NPN polarities reducing model numbers PNP transistor output and NPN transistor output are combined in a single model. Overseas equipment that uses PNP, replacement with NPN sensors, factories that are positively grounded, and transfer of equipment overseas are all situations where the control circuits for a single model are suitable for use worldwide.
Lightweight! The SF4C series is made of resin that is approx. 45 % lighter than the conventional aluminum case type. Its lightweight body eases the burden on the mounting surface of the equipment and contributes to overall reduced weight during equipment transportation or overseas shipment. * Except the cable part
IP67 protection structure An IP67 (IEC) rating is achieved even in an ultra-slim resin body by using a laser welding method.
A fast response time for all models SF4C-H□: 7 ms*, SF4C-F□: 9 ms* The SF4C series reduces the safety distance as well as the calculation work required for the safety distance among models with different beam channels. * When connecting safety sensors (safety light curtains, etc) to the safety input,the response time will be the total time of connected units.
Mutual interference is reduced without needing for interference prevention lines The ELCA (Extraneous Light Check & Avoid) function automatically shifts the scan timing in order to avoid interference.
Material suitable for manufacturing a secondary battery Mounting bracket: SUS304
SF4C body is made of resin and the mounting bracket is made of Stainless Steel Mounting screw: SUSXM7* (SUS), so materials used are limited. Suitable for Body case: manufacturing secondary Polycarbonate alloy batteries or for food production equipment. * Effective from production in November 2010.
Reducing the number of malfunctions caused by extraneous light Double scanning method and retry processing are effective in eliminating the effects of extraneous light.
Selection Guide Safety Light Curtains Safety Control Units Safety Components
SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights
579 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS
Ultra-slim Safety Light Curtain Type 4
Handy-controller SFC-HC (Opitonal) enables the user to select a variety of settings
Operation of large multi-purpose indicators (factory setting: mode 0)
Large Mode Large Control outputs multi-purpose multi-purpose No. indicator 1 indicator 2 (OSSD 1 / OSSD 2) OFF High or Low High or Low ON 0 Lights up in red Lights up in green 1 Blinks in red Blinks in green 2 Lights up in red Blinks in green 3 Blinks in red Lights up in green 4 (Note 1) Lights up in red Blinks in red 5 (Note 1) Blinks in green Lights up in green 6 (Note 1) Lights up in green Lights up in red 7 (Note 1) Lights up in red Blinks in red -
Muting function
Override function
Valid
Valid
Blinks in green Lights up in green Blinks in green
Lockout blinking function
When lockout occurs
Valid
Blinks in red
Description Negative logic of the control outputs (OSSD 1, OSSD 2) (factory setting)
1
Positive logic of the control outputs (OSSD 1, OSSD 2)
PLC
2
For test input enabled: output OFF, For Disabled: output ON
3
For test input enabled: output ON, For Disabled: output OFF
HUMAN MACHINE INTERFACES
4
For unstable incident beam: OFF (Note 1)
ENERGY MANAGEMENT SOLUTIONS
5
For unstable incident beam: ON (Note 1)
6
For muting: ON
7
For muting: OFF
8
For beam received: ON, For beam interrupted: OFF (Note 2)
Selection Guide Safety Light Curtains Safety Control Units Safety Components
SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights
9
For beam received: OFF, For beam interrupted: ON (Note 2)
A
For safety input enabled: ON, Disabled: OFF
B
For safety input enabled: OFF, Disabled: ON
C
For lockout: OFF
D
For lockout: ON
1, 2 or 3 non-specified beam channels can be deactivated. This function is useful in the event when an object passes through the safety light curtain’s sensing area.
Notes: 1) The output cannot be used while the fix blanking function, floating blanking function or the muting function is activated. 2) This device outputs the beam received/interrupted state under activating the auxiliary output switching function using the handy-controller irrespective of activating other functions, fixed blanking function, floating blanking function, and muting function. Note: When the floating blanking function is used, the size of the min. sensing object is changed.
Safety, productivity, and cost reduction [Muting control function] The safety light curtain has a built-in muting control function that causes the line to stop only when a person passes through the safety light curtain, and does not stop the line when an object passes through. The muting sensors and muting lamps can be connected directly to the safety light curtain. Furthermore, the large multi-purpose indicators can be used as muting lamps, which contribute to less wiring troubles, improvement of safety and productivity, and cost reduction.
Muting lamps
Previous
UV CURING SYSTEMS
Floating blanking function which allows non-specified beam channels to be deactivated improves productivity
Muting sensors Safety circuit (Safety relay, etc.)
Safety light curtain
SF4C series
MACHINE VISION SYSTEMS
The SF4C series is equipped with a fixed blanking function which allows specific beam channels to be selectively interrupted without causing the control output (OSSD) to output the OFF signal. This function is convenient for use with applications in which certain fixed obstacles tend to interrupt specific beam channels.
Auxiliary output has selectable output configuration 0
FA COMPONENTS
Fixed blanking function which allows selective beam channels to be activated improves productivity
Invalid
Mode No.
LASER MARKERS
SFC-HC
Notes: 1) Blinking takes precedence in case of same color brinks or light up. Notes: 2) During lockout, it is possible to blink in red.
WIRE-SAVING SYSTEMS
STATIC CONTROL DEVICES
HC
Operation of the large multi-purpose indicators can be configured
SIMPLE WIRE-SAVING UNITS
MEASUREMENT SENSORS
SF4C SERIES
Muting lamps
Muting unit
Muting sensors Safety circuit (Safety relay, etc.)
SF4C series
* If a failure diagnosis of muting lamp is needed as by the result of risk assessment, use the handy-controller SFC-HC (optional) to change the setting, and connect the muting lamp output wire (red) of this safety light curtain to an incandescent lamp separately.
Ultra-slim Safety Light Curtain Type 4
SF4C SERIES
HC
Selective muting area [Separate muting control function for each beam channel] The handy-controller SFC-HC (optional) can be used to carry out muting control for specified beam channels only. Because individual beam channel can be specified to suit the object, separate guards to prevent entry do not need to be set up.
While muting control is active (line operating)
Line stopped
580 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS
For example, depending on the height of the object, the muting function can be activated for 10 beam channels starting from the bottom most, so that if the 11th or subsequent beam channels are interrupted, it is judged that a person has entered the area and the line stops.
HC
Safety measures when objects exit [Exit muting control function] Muting at the exit of a machine is now possible using the handy-controller SFC-HC (optional). Just set a Max. four sec. delay timer on the muting sensors located at the exit. This is efficient for places with no installation space for muting sensors and also reduces cost and wiring.
SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS
Entrance side
WIRE-SAVING SYSTEMS MEASUREMENT SENSORS
Exit side
STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS
Muting sensors are not needed on the exit side!
FA COMPONENTS
By installing muting sensors only within the dangerous zone and setting up a delay timer on the sensor, muting control is made possible even on the exit side where muting sensors cannot be installed.
MACHINE VISION SYSTEMS UV CURING SYSTEMS
Reset input
Safety light curtain
SF4C series
The safety light curtain has a built-in external device monitoring function (such as deposited relay monitoring) and an interlock function. This allows a safety circuit to be constructed so that a separate safety relay unit is not needed, and the control box has become smaller to help to achieve to lower costs.
Previous
Safety circuit is constructed without the need for a safety relay unit [External device monitoring function] Monitoring
Safety relay unit
Safety relays
Motor, etc.
Reset input
SF4C series
Monitoring
Safety relays
Motor, etc.
The safety light curtain can directly connect to external devices (safety relay, etc) without an exclusive control unit. This allows for simplified equipment, cost reduction, and error prevention.
Selection Guide Safety Light Curtains Safety Control Units Safety Components
SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights
581 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS
Ultra-slim Safety Light Curtain Type 4
SF4C SERIES
Industry first*! Wire-saving when connecting to safety devices [Safety input function] Contact outputs such as an emergency stop switches or a safety door switches can be connected to the safety light curtain. Also, by using the handy-controller SFC-HC (optional) up to three sets of safety light curtains can be cascade connected for a consolidated safety output. * As of March 2009, in-company survey
Direct connection of safety devices
Safety door switch, emergency stop switch, etc.
SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS
SF4C series
Previous
SENSOR OPTIONS
Monitoring
Safety door switch, emergency stop switch, etc.
2NC
Monitoring
2NC
MEASUREMENT SENSORS
PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS
SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights
SF4C series
Contactor
Safety relays
Motor, etc.
Direct connection of various safety devices is possible for a simplified safety circuit.
By using the handy-controller SFC-HC (optional) up to three sets of safety light curtains can be cascade connected for a consolidated safety output. (Note) SF4C series
Previous Monitoring
Safety door switch, emergency stop switch, etc. 2NC
Monitoring
Monitoring Selection Guide Safety Light Curtains Safety Control Units Safety Components
Motor, etc.
A safety relay unit is needed for connecting safety devices other than safety light curtain.
MACHINE VISION SYSTEMS UV CURING SYSTEMS
Contactor
Safety relay unit
Contactor
Motor, etc.
Two safety relays are needed
Safety light curtain for each set of safety light curtain
Three sets of safety light curtains require three sets of safety relays.
2NC
HC
Safety door switch, emergency stop switch, etc.
Just two safety relays are enough
Monitoring
LASER MARKERS
Safety light curtain Safety relays Safety relay unit
Individual monitoring by auxiliary output
STATIC CONTROL DEVICES
SF4C series
Contactor
Motor, etc.
Outputs of safety devices are consolidated in one unit.
Individual monitoring on safety light curtains is possible while the outputs of three sets of safety light curtains and other safety devices are consolidated in one unit.
Note: This setting is possible with the use of handy-controller SFC-HC (optional) for SF4C series Ver.2.1 or later.
Ultra-slim Safety Light Curtain Type 4
SF4C SERIES
582
PRODUCT CONFIGURATION
FIBER SENSORS
Maintenance is prioritized Pigtailed type (with mounting bracket, connector attached cable)
Basic set in one model No. Cable type [Mounting bracket, with 5 m (16.404 ft) cable] Standard mounting bracket MS-SFC-1 (Accessory)
Standard mounting bracket MS-SFC-1 (Accessory)
1
AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS
3 Cable 5 m 16.404 ft (discrete wire)
Connector attached cable 0.5 m 1.640 ft
SENSOR OPTIONS
1 2 Safety light curtains
Min. sensing object ø14 mm ø0.551 in (10 mm 0.394 in beam pitch)
10 mm 0.394 in
Protective height
0.1 to 3 m 0.328 to 9.843 ft
Beam pitch 10 mm 10 mm 0.394 in 0.394 in Beam channel No.
Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch)
Finger protection type Hand protection type
Operating range (Note 1)
Appearance Beam channel No.
10 mm 0.394 in
Protective height
0.1 to 3 m 0.328 to 9.843 ft Beam pitch 10 mm 20 mm 0.394 in 0.787 in Actual operating range 0.1 m of the safety light curtain 0.328 ft Setting range of the receiver
3m 9.843 ft
Number of beam 2 Cable type channels
Model No. (Note 2)
1 Pigtailed type
Protective height (mm in)
SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS
SF4C-F15-J05
SF4C-F15
15
160 mm 6.299 in
SF4C-F23-J05
SF4C-F23
23
240 mm 9.449 in
MEASUREMENT SENSORS
SF4C-F31-J05
SF4C-F31
31
320 mm 12.598 in
STATIC CONTROL DEVICES
SF4C-F39-J05
SF4C-F39
39
400 mm 15.748 in
LASER MARKERS
SF4C-F47-J05
SF4C-F47
47
480 mm 18.898 in
SF4C-F55-J05
SF4C-F55
55
560 mm 22.047 in
SF4C-F63-J05
SF4C-F63
63
640 mm 25.197 in
SF4C-H8-J05
SF4C-H8
8
160 mm 6.299 in
ENERGY MANAGEMENT SOLUTIONS
SF4C-H12-J05
SF4C-H12
12
240 mm 9.449 in
FA COMPONENTS
SF4C-H16-J05
SF4C-H16
16
320 mm 12.598 in
MACHINE VISION SYSTEMS
SF4C-H20-J05
SF4C-H20
20
400 mm 15.748 in
SF4C-H24-J05
SF4C-H24
24
480 mm 18.898 in
UV CURING SYSTEMS
SF4C-H28-J05
SF4C-H28
28
560 mm 22.047 in
SF4C-H32-J05
SF4C-H32
32
640 mm 25.197 in
Notes: 1) The operating range is the possible setting distance between the emitter and the receiver. Receiver cannot be placed in this range
INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS
ORDER GUIDE
Type
PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS
2
4
LASER SENSORS
2) The model No. with suffix “E” shown on the label affixed to the product is the emitter, “D” shown on the label is the receiver.
PLC HUMAN MACHINE INTERFACES
Selection Guide Safety Light Curtains Safety Control Units Safety Components
SF4D Emitter
Receiver
SF4B/ SF4B-G
Receiver
SF4B-C
3 4 Mating cables Appearance
For receiver For emitter
3 With connectors on both ends
4
Mating cables
W ith connector on one end
Type
SF4C
Model No.
Description
SFB-CC10-MU
Length: 3 m 9.843 ft Cable with connector on one end for pigtailed type Net weight: 430 g approx. (2 cables) Two cables per set for emitter and receiver Length: 7 m 22.966 ft Cable color: Gray (for emitter), Gray with black line (for receiver) Net weight: 1,000 g approx. (2 cables) Length: 10 m 32.808 ft Connector color: Gray (for emitter), Black (for receiver) Net weight: 1,300 g approx. (2 cables) The min. bending radius: R6 mm R0.236 in
SFB-CCJ3E-MU
Length: 3 m 9.843 ft Net weight: 190 g approx. (1 cable)
SFB-CC3-MU SFB-CC7-MU
10 m 32.808 ft Cable with connectors on both ends for pigtailed type SFB-CCJ10E-MU Length: Net weight: 660 g approx. (1 cable) Cable color: Gray (for emitter), Gray with black line (for receiver)
SFB-CCJ3D-MU
Connector color: Gray (for emitter), Black (for receiver) Length: 3 m 9.843 ft Net weight: 210 g approx. (1 cable) The min. bending radius: R6 mm R0.236 in
10 m 32.808 ft SFB-CCJ10D-MU Length: Net weight: 680 g approx. (1 cable)
BSF4-AH80 SF2B SF2C Definition of Sensing Heights
583 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS
Ultra-slim Safety Light Curtain Type 4
SF4C SERIES
ORDER GUIDE Spare parts (Accessories for safety light curtain) Designation
Model No.
Standard mounting bracket
Description
• MS-SFC-1
Standard mounting bracket
MS-SFC-1
Allows the safety light curtain to be mounted at the rear with one M5 hexagon-socket-head bolt. Mounting direction of the bracket can be selected between vertical or horizontal (no dead zone). (4 pcs. per set for emitter and receiver)
Test rod ø14
SF4C-TR14
Min. sensing object for regular checking (ø14 mm ø0.551 in)
Test rod ø25
SF4C-TR25
Min. sensing object for regular checking (ø25 mm ø0.984 in)
Safety light curtain
M5 hexagonsocket-head bolt Purchase separately. Four bracket set Four M3 (length: 4 mm 0.157 in) countersunk screws
<Mountable in three directions>
PARTICULAR USE SENSORS
Safety light curtain
SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS
Standard mounting bracket MS-SFC-1 (Accessory)
WIRE-SAVING SYSTEMS MEASUREMENT SENSORS
M3 (length: 4 mm 0.157 in) countersunk screw with loose-proof agent
STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS
Selection Guide Safety Light Curtains Safety Control Units Safety Components
SF4D SF4B/ SF4B-G
OPTIONS Mounting brackets Designation
Description
NA2-N compatible mounting bracket
MS-SFC-2
Used when changing over area sensor NA2-N series to the SF4C series. The mounting holes of NA2-N series can continue to be used. Center mounting by a M6 hexagon-socket-head bolt is also possible. (4 pcs. per set for emitter and receiver)
Versatile bracket
MS-SFC-3
Two ways of mounting are possible. 1 Rear mounting which enables beam adjustment 2 Dead zoneless center mounting on aluminum frame (4 pcs. per set for emitter and receiver)
MS-SFC-4
Used to support the safety light curtain in the middle. Be sure to purchase it when using the versatile bracket MS-SFC-3(optional) on SF4C-F55(-J05), SF4C-F63(-J05), SF4C-H28(-J05) or SF4C-H32(-J05). (2 pcs. per set for emitter and receiver)
Intermediate supporting bracket for versatile bracket
Versatile bracket
BSF4-AH80 SF2B SF2C Definition of Sensing Heights
• MS-SFC-2
• MS-SFC-4
Mounting holes for M4 screw Mounting hole for M6 hexagon-sockethead bolt
Mounting holes for M4 screw
Mounting hole for M6 hexagon-sockethead bolt M4 screw Purchase separately.
Safety light curtain
Intermediate supporting bracket for versatile bracket
• MS-SFC-3
SF4B-C SF4C
NA2-N compatible mounting bracket
Model No.
Mounting hole for M6 hexagon-sockethead bolt
Mounting holes for M4 screw
Mounting hole for M6 hexagon-sockethead bolt (Mount on either one)
Ultra-slim Safety Light Curtain Type 4
SF4C SERIES
OPTIONS
FIBER SENSORS LASER SENSORS
Control unit Designation
Appearance
Model No.
Slim type control unit
PHOTOELECTRIC SENSORS
Description
MICRO PHOTOELECTRIC SENSORS
Use a discrete wire cable to connect to the safety light curtain. Relay output. Compatible with up to Control Category 4.
SF-C13
AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS
●Recommended safety relay Panasonic Corporation SF relay, slim type SF relay, slim type SFS3-L-DC24V (AG1S132) SFS4-L-DC24V (AG1S142)
Item
DIN terminal block SFS4-SFD (AG1S847)[4-poles type] SFS6-SFD (AG1S867)[6-poles type]
Note: Contact Panasonic Corporation for details on the recommended products.
Type Model No. Part No.
With LED indicator SFS3-L-DC24V SFS4-L-DC24V AG1S132 AG1S142
Contact arrangement Rated nominal switching capacity Min. switching capacity Coil rating Rated power consumption Operation time Release time
3a1b
4a2b
6 A / 250 V AC, 6 A / 30 V DC 1 mA / 5 V DC 20.8 mA / 24 V DC 15 mA / 24 V DC
Ambient temperature Applicable standards
360 mW
500 mW
20 ms or less 20 ms or less –40 to +85 °C –40 to +185 °F (Humidity: 5 to 85 % RH) UL/c-UL, TÜV, Korea's S-mark
Appearance
Wire-saving Y-shaped connector
Model No.
SFC-WY1
Cable with connector on one side
Description Wire-saving connector for SF4C-F□-J05 and SF4C-H□-J05. Cables of emitter and receiver are consolidated into one cable for wire-saving. Wiring has +24 V, 0 V, OSSD 1, OSSD 2, output polarity setting wire (shield), large multi-purpose indicator input 1, and large multi-purpose indicator input 2 only. Net weight: 40 g approx. Power wire and synchronization wire are connected inside the connector. Interlock is disabled (automatic reset).
WY1-CCN3
Cable length: 3 m 9.843 ft Net weight: 200 g approx. (1 cable)
WY1-CCN10
Cable length: 10 m 32.808 ft Net weight: 620 g approx. (1 cable)
Mating cable for Y-shaped connector Cable color: Gray (with black line) Connector color: Black The min. bending radius: R6 mm R0.236 in Connector outer diameter: ø14 mm ø0.551 in max.
PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS
A total of 24 wires
Y-shaped connector
HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS
Selection Guide Safety Light Curtains
By using the Y-shaped connector, the least required wires such as power or safety output are consolidated into one cable. Man-hours taken for wiring is eliminated to the minimum. Construction times as well as wiring mistakes are greatly reduced. Previous
INDUCTIVE PROXIMITY SENSORS
PLC
Y-shaped connectors Type
584
Only 7 wires Less wiring mistakes! Reduced wiring time! Easy wiring to Safety PLC, etc.
Safety Control Units Safety Components
SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C
SF4C series Pig tailed type
SF4C series Cable type Safety PLC / Remote I/O / Safety relay unit / SF-C13, etc.
Safety PLC / Remote I/O / Safety relay unit / SF-C13, etc.
Definition of Sensing Heights
585 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS
Ultra-slim Safety Light Curtain Type 4
OPTIONS Product configuration Emitter Receiver ・
MICRO PHOTOELECTRIC SENSORS
PRESSURE / FLOW SENSORS
Extension cable
Extension cable (1 cable for receiver) SFB-CCJ3D-MU (3 m 9.843 ft for receiver) SFB-CCJ10D-MU (10 m 32.808 ft for receiver)
AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS
SF4C SERIES
Pigtailed type 0.5 m 1.640 ft
Extension cable (1 cable for emitter)
INDUCTIVE PROXIMITY SENSORS
SFB-CCJ3E-MU (3 m 9.843 ft for emitter) SFB-CCJ10E-MU (10 m 32.808 ft for emitter)
PARTICULAR USE SENSORS
SFB-CCJ3D (3 m 9.843 ft) SFB-CCJ10D (10 m 32.808 ft)
Y-shaped connector SFC-WY1
Cable with connector on one side (Common for all models) WY1-CCN3 (3 m 9.843 ft) WY1-CCN10 (10 m 32.808 ft)
SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS
Connector pin layout Black connector
WIRE-SAVING SYSTEMS MEASUREMENT SENSORS
2
Connector pin No.
1 8
3
Receiver
7
STATIC CONTROL DEVICES
Emitter
6
4 5
Gray connector
LASER MARKERS PLC
Description
1
OSSD 2
2
+24 V
3
OSSD 1
4
Not used
5
Large multi-purpose indicator input 1
6
Large multi-purpose indicator input 2
7
0V
8
Output polarity setting wire (Shield)
HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS
Wiring diagram of control unit SF-C13
• Connect the safety light curtain control outputs OSSD 1 and OSSD 2 to S1 and S2 respectively.
• Connect the safety light curtain control outputs OSSD 1 and OSSD 2 to S4 and S2 respectively and ground the + side.
UV CURING SYSTEMS
Selection Guide Safety Light Curtains
Y-shaped connector
WY1-CCN□
+24 V DC
+24 V DC
Not used (Yellow-green)
+24 V (Brown)
Safety Components
0V (Blue)
SF4D
Not used (Yellow-green)
+24 V (Brown)
Large multi-purpose indicator input 1 (Gray)
Large multi-purpose indicator input 2 (Gray / Black)
Output polarity setting wire (Shield)
PLC, etc.
A1
S1
BSF4-AH80 Ui
OSSD 1 (Black)
L1
RESET (Note 1) (Note 1) FUSE1 FUSE2 (Note 2) S2 S3 S4 X1 X2 X3 13 23 33 41
F
SF2B
PLC, etc.
OSSD 2 (White)
OSSD 2 (White)
SF4B-C
Large multi-purpose indicator input 2 (Gray / Black)
Output polarity setting wire 0 V (Shield) (Blue)
OSSD 1 (Black)
SF4B/ SF4B-G
F.G.
K1
S1
S2 S3 S4
X1
X2
F Ui
A2 0V
INTER_LOCK
AUX KA, KB: Force-guided relay F.G. or magnet contactor
KA N
FUSE2 33 41
K1
RESET (Note 1) (Note 2)
K2
FAULT 14 24
X3 13 23
SF-C13 control circuit
K2 OUT
L1 (Note 1) FUSE1
A1
SF-C13 control circuit
SF2C Definition of Sensing Heights
Y-shaped connector
WY1-CCN□
Large multi-purpose indicator input 1 (Gray)
Safety Control Units
SF4C
Safety light curtain (SF4C-F□-J05 and SF4C-H□-J05)
Safety light curtain (SF4C-F□-J05 and SF4C-H□-J05)
34 42
L1L2L3
KB
OUT
KB KA
M 3~
Notes: 1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. 3) Unused wires must be insulated.
A2 0V
INTER_LOCK
FAULT
14 24 34 42 AUX KA, KB: Force-guided relay KB or magnet contactor KA N
L1L2L3
KB KA
M 3~
Notes: 1) The above diagram is when using manual reset. If automatic reset is used, disconnect the lead from X2 and connect it to X3. In this case, a reset (RESET) button is not needed. 2) Use a momentary-type switch as the reset (RESET) button. 3) Unused wires must be insulated.
Ultra-slim Safety Light Curtain Type 4
SF4C SERIES
OPTIONS
FIBER SENSORS
Handy-controller
LASER SENSORS
Pigtailed type Appearance
Model No. Mating cable
Handycontroller
Fixe d Floa blan ting king Aux blan Lighiliary king cont emoutp trol issi ut on
Co de Mo nito Pro r Co tect py
FU
NC TIO
N
SFC-HC
CEL
ENTER
TE R
Handy-controller
Cable type +V 0 V
Cable set for cable type connection
Synchronization – Synchronization +
Not used
FUNCTION
CANCEL
Terminal block
ENTER
Handy-controller
SF4C-F□
Designation
SAFETY LIGHT CURTAINS / SAFETY COMPONENTS
INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS
Metal protection case Applicable beam channels
MICRO PHOTOELECTRIC SENSORS
PRESSURE / FLOW SENSORS
Cable set
Control circuit
SFC-WNC1
PHOTOELECTRIC SENSORS
AREA SENSORS
FUNCTION
CANCEL
CAN
EN
Control circuit
Designation
586
Metal protection case (2 pcs. per set for emitter and receiver)
SF4C-H□
Model No.
15
8
MS-SFCH-8
23
12
MS-SFCH-12
31
16
MS-SFCH-16
39
20
MS-SFCH-20
47
24
MS-SFCH-24
55
28
MS-SFCH-28
63
32
MS-SFCH-32
• MS-SFCH-8
• MS-SFCH-12/16/20/24/28/32
SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES
Introduction to Panasonic Industrial Devices SUNX sensors that can be used as muting sensors Compact Photoelectric Sensor
CX-400 SERIES Ver.2
Ultra-slim Photoelectric Sensor
EX-10 SERIES Ver.2
U-shaped Micro Photoelectric Sensor
PM-25/45/65 SERIES
Rectangular-shaped Inductive Proximity Sensor
GX-F/H SERIES
ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS
• World standard size • Wide variation
• 3.5 mm 0.138 in thickness • Long sensing range: 1 m 3.281 ft (thru-beam type: EX-19) * The EX-20 series that is compatible with M3 mounting screws is also available.
P.245~
P.279~
• Three protection circuits standard on all models • Ample beam emitting / receiving distance of 6 mm 0.236 in
• Easy to mount with M3 screws
P.395~
• Industry longest in stable sensing range • 10 times the durability (Compared to previous models) • IP68G rating
Selection Guide Safety Light Curtains Safety Control Units Safety Components
P.785~ SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights
587
Ultra-slim Safety Light Curtain Type 4
SPECIFICATIONS
FIBER SENSORS
MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS
SF4C-F□
Item
Model No.
PHOTOELECTRIC SENSORS
Safety light curtain individual specifications
No. of beam channels Protective height Large multipurpose indicator lights off Large multipurpose indicator lights up PFHD MTTFD Net weight Pigtailed Total of type emitter and Cable type receiver
( )
LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS
Selection Guide Safety Light Curtains Safety Control Units Safety Components
SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights
Model No.
Item
Type Pigtailed type Cable type
No. of beam channels Protective height Large multipurpose indicator lights off Large multipurpose indicator lights up PFHD MTTFD Net weight Pigtailed Total of type emitter and Cable type receiver
Current consumption
STATIC CONTROL DEVICES
15 160 mm 6.299 in
Min. sensing object ø14 mm ø0.551 in type (10 mm 0.394 in beam pitch) SF4C-F23-J05 SF4C-F31-J05 SF4C-F39-J05 SF4C-F47-J05 SF4C-F55-J05 SF4C-F23 SF4C-F31 SF4C-F39 SF4C-F47 SF4C-F55
SF4C-F63-J05 SF4C-F63
23 31 39 47 55 63 240 mm 9.449 in 320 mm 12.598 in 400 mm 15.748 in 480 mm 18.898 in 560 mm 22.047 in 640 mm 25.197 in
Emitter: 70 mA or less Receiver: 80 mA or less
Emitter: 75 mA or less Receiver: 85 mA or less
Emitter: 80 mA or less Receiver: 90 mA or less
Emitter: 85 mA or less Receiver: 95 mA or less
Emitter: 105 mA or less Receiver: 110 mA or less
Emitter: 110 mA or less Receiver: 115 mA or less
Emitter: 115 mA or less Receiver: 120 mA or less
Emitter: 120 mA or less Receiver: 125 mA or less
2.29 × 10–9
2.73 × 10–9
3.18 × 10–9
3.62 × 10–9 100 years or more
4.06 × 10–9
4.50 × 10–9
4.95 × 10–9
210 g approx.
270 g approx.
340 g approx.
400 g approx.
470 g approx.
540 g approx.
600 g approx.
600 g approx.
670 g approx.
730 g approx.
800 g approx.
860 g approx.
930 g approx.
1,000 g approx.
SF4C-H□
WIRE-SAVING SYSTEMS MEASUREMENT SENSORS
Type Pigtailed type SF4C-F15-J05 SF4C-F15 Cable type
Current consumption
LASER SENSORS
SF4C SERIES
( )
SF4C-H8-J05 SF4C-H8
Min. sensing object ø25 mm ø0.984 in type (20 mm 0.787 in beam pitch) SF4C-H12-J05 SF4C-H16-J05 SF4C-H20-J05 SF4C-H24-J05 SF4C-H28-J05 SF4C-H32-J05 SF4C-H12 SF4C-H16 SF4C-H20 SF4C-H24 SF4C-H28 SF4C-H32
8 160 mm 6.299 in
12 16 20 24 28 32 240 mm 9.449 in 320 mm 12.598 in 400 mm 15.748 in 480 mm 18.898 in 560 mm 22.047 in 640 mm 25.197 in
Emitter: 70 mA or less Receiver: 85 mA or less
Emitter: 70 mA or less Receiver: 90 mA or less
Emitter: 75 mA or less Receiver: 95 mA or less
Emitter: 80 mA or less Receiver: 100 mA or less
Emitter: 120 mA or less Receiver: 135 mA or less
Emitter: 120 mA or less Receiver: 140 mA or less
Emitter: 120 mA or less Receiver: 145 mA or less
Emitter: 120 mA or less Receiver: 150 mA or less
1.66 × 10–9
1.90 × 10–9
2.10 × 10–9
2.33 × 10–9 100 years or more
2.54 × 10–9
2.77 × 10–9
2.98 × 10–9
240 g approx.
300 g approx.
360 g approx.
420 g approx.
490 g approx.
550 g approx.
610 g approx.
630 g approx.
700 g approx.
760 g approx.
820 g approx.
880 g approx.
950 g approx.
1,000 g approx.
Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. PFHD: Probability of dangerous failure per hour, MTTFD: Mean time to dangerous failure (in years)
Ultra-slim Safety Light Curtain Type 4
SF4C SERIES
SPECIFICATIONS
FIBER SENSORS
Safety light curtain common specifications Type Applicable standards
Item
Model No.
International standard Japan Europe (EU) (Note 2) North America (Note 3)
Pigtailed type SF4C-F□-J05
Supply voltage
SF4C-H□-J05
SF4C-F□
SF4C-H□
ANSI/UL 61496-1/2 (Type 4), ANSI/UL 508, UL 1998 (Class 2), CAN/CSA 61496-1/2 (Type 4), CAN/CSA C22.2 No.14, OSHA 1910.212, OSHA 1910.217(C), ANSI B11.1 to B11.19, ANSI/RIA 15.06 Machinery Directive, EMC Directive, RoHS Directive
Operating range (Note 4) Min. sensing object (Note 5) Effective aperture angle
LASER SENSORS
Cable type
IEC 61496-1/2 (Type 4), ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL 3) JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL 3) EN 61496-1 (Type 4), EN ISO 13849-1 (Category 4, PLe), EN 61508-1 to 7 (SIL 3), EN 55011, EN 50178, EN 61000-6-2
CE marking directive compliance Beam pitch
0.1 to 3 m 0.328 to 9.843 ft 10 mm 0.394 in
20 mm 0.787 in
10 mm 0.394 in
20 mm 0.787 in
ø14 mm ø0.551 in opaque object ø25 mm ø0.984 in opaque object ø14 mm ø0.551 in opaque object ø25 mm ø0.984 in opaque object ±2.5° or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2)] 24 V DC +10 –15 % Ripple P-P 10 % or less
PNP open-collector transistor / NPN open-collector transistor (switching method)
Control outputs (OSSD 1, OSSD 2)
Operation mode Protection circuit Response time
Auxiliary output (Non-safety output)
<When selecting PNP output> • Max. source current: 200 mA • Applied voltage: same as supply voltage (between the control output and +V) • Residual voltage: 2.5 V or less (source current 200 mA, when using 10 m 32.808 ft length cable) • Leakage current: 200 µA or less (including power supply OFF condition) • Max. load capacity: 1 µF (No load to Max. source current) • Load wiring resistance: 3 Ω or less
<When selecting NPN output> • Max. sink current: 200 mA • Applied voltage: same as supply voltage (between the control output and 0 V) • Residual voltage: 2.5 V or less (sink current 200 mA, when using 10 m 32.808 ft length cable) • Leakage current: 200 µA or less (including power supply OFF condition) • Max. load capacity: 1 µF (No load to Max. sink current) • Load wiring resistance: 3 Ω or less
ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal)(Note 6,7) Incorporated OFF response: 9 ms or less, OFF response: 7 ms or less, OFF response: 9 ms or less, ON response: 90 ms or less ON response: 90 ms or less ON response: 90 ms or less PNP open-collector transistor / NPN open-collector transistor (switching method) <When selecting PNP output> • Max. source current: 100 mA • Applied voltage: same as supply voltage(between the auxiliary source and +V) • Residual voltage: 2.5 V or less (source current 100 mA, when using 10 m 32.808 ft length cable)
OFF response: 7 ms or less, ON response: 90 ms or less
<When selecting NPN output> • Max. sink current: 100 mA • Applied voltage: same as supply voltage(between the auxiliary sink and 0 V) • Residual voltage: 2.5 V or less (sink current 100 mA, when using 10 m 32.808 ft length cable)
Operation mode OFF when control outputs are ON, ON when control outputs are OFF [Factory setting, operating mode can be changed using the handy-controller SFC-HC(optional).] Protection circuit Incorporated ELCA function Incorporated (reducing mutual interference automatically) Test / reset input function Incorporated Interlock function Incorporated [Manual reset / Automatic reset (Note 8)] External device monitoring function Incorporated Safety input function Incorporated (safety contact) Muting function / Override function Incorporated Optional functions (Note 9)
Environmental resistance
Pollution degree Operating altitude Degree of protection Ambient temperature Ambient humidity Ambient illuminance Dielectric strength voltage Insulation resistance Vibration resistance Shock resistance Emitting element Material Cable Cable extension Accessories
588
Fixed blanking, floating blanking, auxiliary output change, safety input (safety sensor), large multi-purpose indicator setting change, interlock setting change, external relay monitoring setting change, muting setting change, override setting change, protecting 3 2,000 m 6,561 68 ft or less (Note 10) IP67 / IP65 (IEC) –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +60 °C –13 to +140 °F 30 to 85 % RH, Storage: 30 to 85 % RH Incandescent light: 5,000 ℓx or less at the light-receiving face 1,000 V AC for one min. between all supply terminals connected together and enclosure 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each 300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each Infrared LED (Peak emission wavelength: 855 nm 0.034 mil) Enclosure: Polycarbonate alloy, Sensing surface: Polycarbonate alloy, MS-SFC-1 (Standard mounting bracket): SUS 0.15 mm2 (power line: 0.2 mm2) 12-core heat-resistant PVC cable with connector, 0.5 m 1.640 ft long 0.15 mm2 (power line: 0.2 mm2) 8-core heat-resistant PVC cable, 5 m 16.404 ft long Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver optional mating cables
Extension up to 40.5 m 132.874 ft is possible for both emitter and receiver, with 0.2 mm2 or more cable (Note 11) (Note 12)
MS-SFC-1 (Standard mounting bracket): 1 set, MS-SFC-1 (Standard mounting bracket): 1 set, MS-SFC-1 (Standard mounting bracket): 1 set, MS-SFC-1 (Standard mounting bracket): 1 set, SF4C-TR14 (Test rod): 1 No. SF4C-TR25 (Test rod): 1 No. SF4C-TR14 (Test rod): 1 No. SF4C-TR25 (Test rod): 1 No.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) Regarding EU Machinery Directive, a Notified Body, TÜV SÜD, has certified with the type examination certificate. 3) With regards to the standards in the US, under the US regulation 29 CFR 1910.7, TÜV SÜD, a Nationally Recognized Testing Laboratory (NRTL) certified by OSHA, has certified with the safety certificate based on UL/ANSI standards. With regards to the standards in Canada, under the safety regulations based on CEC (Canadian Electric Code), TÜV SÜD America, a Certification Body accredited by SCC, has certified with the safety certificate based on CSA standards. 4) The operating range is the possible setting distance between the emitter and the receiver. 5) When the floating blanking function is used, the size of the min. sensing object is changed. 6) The outputs are not “OFF” when muting function is active even if the beam channel is interruped. 7) In case the blanking function is valid, the operation mode is changed. 8) The manual reset and automatic reset are possible to be switched depending on the wiring status. 9) In case of using optional function, the handy-controller SFC-HC (optional) is required. 10) D o not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. 11) When the muting lamp is used, the cable can be extended within 30.5 m 100.066 ft (for emitter / receiver). 12) When the synchronization + wire (orange) and synchronization - wire (orange / black) is extended with a cable other than exclusive cable, use a 0.2 mm2 or more shielded twisted pair cable.
PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS
Selection Guide Safety Light Curtains Safety Control Units Safety Components
SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights
589
LASER SENSORS PHOTOELECTRIC SENSORS
SPECIFICATIONS Control unit Model No.
Item
MICRO PHOTOELECTRIC SENSORS
Connectable safety light curtains
AREA SENSORS
Applicable standards
SAFETY LIGHT CURTAINS / SAFETY COMPONENTS
CE marking directive compliance
PRESSURE / FLOW SENSORS
Supply voltage / Current consumption
INDUCTIVE PROXIMITY SENSORS
WIRE-SAVING SYSTEMS
LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS
24 V DC ± 10 % Ripple P-P 10 % or less / 100 mA or less (without safety light curtain) NO contact × 3 (13-14, 23-24, 33-34)
Application category Rated operation voltage (Ue) / Rated operation current (le) Contact resistance Contact protection fuse rated Pick-up delay (Auto reset / Manual reset) Response time (Recovery time) Auxiliary output
AC-15, DC-13 (IEC 60947-5-1) 30 V DC / 4 A, 230 V AC / 4 A, resistive load (For inductive load, during contact protection). Min applicable load: 10 mA (at 24 V DC) (Note 2) 100 mΩ or less (initial value) 4 A (slow blow) 80 ms or less / 90 ms or less 10 ms or less Safety relay contact (NC contact) × 1 (41-42) (Related to safety output)
Rated operation voltage / current Contact protection fuse rated Semiconductor auxiliary output (AUX) Output operation Excess voltage category Polarity selection function Pollution degree Environmental resistance
STATIC CONTROL DEVICES
Machinery Directive, Low Voltage Directive, EMC Directive, RoHS Directive
Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down
Safety output
MEASUREMENT SENSORS
Safety light curtain manufactured by Panasonic Industrial Devices SUNX
ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards
Fuse (power supply)
SENSOR OPTIONS
SF-C13 EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1 (Category 4, PLe), IEC 61496-1 (Type 4), ISO 13849-1 (Category 4, PLe), JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4), ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2)
Control category
PARTICULAR USE SENSORS
SIMPLE WIRE-SAVING UNITS
SF4C SERIES
24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) 2 A (slow blow) PNP open-collector transistor • Max. source current: 60 mA On when the safety light curtain is interrupted II Incorporated (Cable connection allows selection of plus/minus ground) Minus ground: Correspond to PNP output safety light curtain Plus ground: Correspond to NPN output safety light curtain 2
Protection
Enclosure: IP40, Terminal IP20
Ambient temperature Ambient humidity Vibration resistance
Enclosure material
–10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F 30 to 85 % RH, Storage: 30 to 95 % RH Resistance/malfunction 10 to 55 Hz frequency, 0.35 mm 0.014 in double amplitude in X, Y, and Z directions twenty times each ABS
Weight
Net weight: 200 g approx.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F 2) If several SF-C13 units are being used in line together, leave a space of 5 mm 0.197 in or more between each unit. If the units are touching each other, reduce the rated operating current for safety output in accordance with the ambient operating temperature as shown in the graphs at right. 3) Refer to p.667 for details of the specifications for SF-C13.
Selection Guide Safety Light Curtains
Dilating when SF-C13 units are mounted close together 6 Rated operation current (A)
FIBER SENSORS
Ultra-slim Safety Light Curtain Type 4
5 4 3 2
Safety Control Units
1
Safety Components
0 32
SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights
Handy-controller Item
Model No.
Supply voltage Current consumption Communication method Digital display Function indicators Functions Environmental resistance
SF4D
Ambient temperature Ambient humidity Voltage withstandability Insulation resistance
35 40 45 50 55 95 104 113 122 131 Ambient temperature (°C °F)
SFC-HC 24 V DC +10 –15 % Ripple P-P 10 % or less (common to safety light curtain power supply) 65 mA or less RS-485 two-way communications (Specific procedure) 4-digit red LED display × 2 (Selected beam channels, setting contents etc. are displayed.) Green LED × 9 (Set function is displayed.) Fixed blanking / Floating blanking / Auxiliary output change / Satety input setting change / Large multi-purpose indicator setting change / Muting setting change / Interlock setting change / External device monitoring setting change / Override setting changing function 60 sec. / Protecting –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F 30 to 85 % RH, Storage: 30 to 85 % RH 1,000 V AC for one min. between all supply terminals connected together and enclosure 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Cable
12-core shielded cable, 0.5 m 1.640 ft long, with a connector at the end (2 cables)
Weight
Net weight: 200 g approx.
Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
Ultra-slim Safety Light Curtain Type 4
SF4C SERIES
590
I/O CIRCUIT AND WIRING DIAGRAMS
FIBER SENSORS
I/O circuit diagram
I/O circuit diagram
LASER SENSORS
PHOTOELECTRIC SENSORS
Terminal No. of pigtailed type Color code
Emitter
Terminal No. of pigtailed type Color code
Emitter
(Brown) +V
(Brown) +V
(Pink) Test input / 470 Ω Reset input
6.8 kΩ
(Pale purple) 470 Ω Interlock setting input *S2
0.47 μF
6.8 kΩ 470 Ω (Yellow) Override input *S2
6.8 kΩ
3 kΩ 3 kΩ
(Gray) Safety input 1
24 V DC +10 –15 %
(Gray / Black) Safety input 2
Internal circuit
Receiver
(Yellow) Override input
WIRE-SAVING SYSTEMS
(Orange) Synchronization +
(Orange / Black) Synchronization –
(Orange / Black) Synchronization – Internal circuit
Receiver
MEASUREMENT SENSORS STATIC CONTROL DEVICES
Users’ circuit
LASER MARKERS
(Orange / Black) Synchronization –
PLC
47 kΩ 470 Ω
(Gray) Large multi*S2 purpose indicator input 1
(Shield) Output polarity setting wire (Black) Control output 1 (OSSD 1)
470 Ω
(Gray / Black) Large multi- *S2 purpose indicator input 2
470 Ω
(Sky-blue / White) Muting input 1
*S2
470 Ω
(Sky-blue / Black) Muting input 2
*S2
470 Ω
(Yellow-green) External device monitoring input
47 kΩ
6.8 kΩ
6.8 kΩ 6.8 kΩ
ENERGY MANAGEMENT SOLUTIONS
K2
(White) Control output 2 (OSSD 2)
6.8 kΩ 470 Ω (Yellow-green) External device monitoring input 0.47 μF
6.8 kΩ 47 kΩ 0.1 μF
47 kΩ
(Blue) 0 V K1, K2: External device (Force-guided relay or magnet contactor) Users’ circuit
* S1, S2
47 kΩ 6.8 kΩ 0.1 μF
K1
K2
(Gray) Large multi470 Ω purpose indicator input 1
(Sky-blue / White) 470 Ω Muting input 1
*S2
6.8 kΩ (Sky-blue / Black) 470 Ω Muting input 2
*S2
6.8 kΩ 0.1 μF
UV CURING SYSTEMS
*S2
47 kΩ (Gray / Black) Large multi- *S2 470 Ω purpose indicator input 2
6.8 kΩ Internal circuit
K1 K2
Selection Guide Safety Light Curtains Safety Control Units
(Blue) 0 V K1, K2: External device (Force-guided relay or magnet contactor) Users’ circuit
* S1, S2
Switch S1 • Test input / Reset input For manual reset Vs to Vs – 3.5 V (sink current 5 mA or less): OFF (Note) Open: ON
Switch S1 • Test input / Reset input For manual reset 0 to +2.5 V (source current 5 mA or less): OFF Open: ON
For automatic reset Vs to Vs – 3.5 V (sink current 5 mA or less): ON (Note) Open: OFF
For automatic reset 0 to +2.5 V (source current 5 mA or less): OFF Open: ON
Switch S2 • Interlock setting input, Override input, Muting input 1/2, Large multi-purpose indicator input 1/2, Vs to Vs – 3.5 V (sink current 5 mA or less): Valid (Note) Open: Invalid
FA COMPONENTS MACHINE VISION SYSTEMS
0.1 μF
Note: Vs is the applying supply voltage.
K1
(White) Control output 2 (OSSD 2)
K2
(Black) Control output 1 (OSSD 1)
Internal circuit
HUMAN MACHINE INTERFACES
K1
6.8 kΩ
(Shield) Output polarity setting wire
SIMPLE WIRE-SAVING UNITS
*S2
6.8 kΩ
(Orange) Synchronization +
Users’ circuit
INDUCTIVE PROXIMITY SENSORS
SENSOR OPTIONS
(Blue) 0 V
Sensor circuit
Sensor circuit
6.8 kΩ
PRESSURE / FLOW SENSORS
PARTICULAR USE SENSORS
*S2
(Brown) +V
47 kΩ
0.47 μF
(Pink) Test input / Reset input
6.8 kΩ (Pale purple) 470 Ω Interlock setting input
24 V DC %
+10 –15
*S1
(Orange) Synchronization +
6.8 kΩ 0.1 μF
(Gray / Black) Safety input 2
(Brown) +V
6.8 kΩ 0.1 μF
3 kΩ
(Orange) Synchronization +
47 kΩ
0.1 μF
(Gray) Safety input 1
470 Ω
0.47 μF
Load
+ –
3 kΩ
470 Ω 6.8 kΩ
6.8 kΩ
(Orange / Black) Synchronization –
0.1 μF
6.8 kΩ 0.47 μF
0.47 μF
(Yellow-green / Black) Auxiliary output (Blue) 0 V
SAFETY LIGHT CURTAINS / SAFETY COMPONENTS
(Red) Muting lamp output
+ –
(Shield) Output polarity setting wire
AREA SENSORS
Load
(Yellow-green / Black) Auxiliary output
(Red) Muting lamp output
Sensor circuit
0.47 μF
*S1
6.8 kΩ 6.8 kΩ
6.8 kΩ
(Shield) Output polarity setting wire
Sensor circuit
0.47 μF
MICRO PHOTOELECTRIC SENSORS
Switch S2 • Interlock setting input, Override input, Muting input 1/2, Large multi-purpose indicator input 1/2, 0 to +2.5 V (source current 5 mA or less): Valid Open: Invalid
Safety Components
SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights
591 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS
Ultra-slim Safety Light Curtain Type 4
I/O CIRCUIT AND WIRING DIAGRAMS Connection example Basic wiring: Min. operation only This is the general configuration using one set of the emitter and receiver facing each other. The control outputs (OSSD 1 / OSSD 2) turn OFF if the light is interrupted, while they automatically turn ON if receive the light. The auxiliary output is used to invalid the external device monitoring function. The auxiliary output cannot be connected to external devices. Receiver
Emitter
PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS
Selection Guide Safety Light Curtains Safety Control Units Safety Components
SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights
SF4C SERIES
Gray cable Gray cable (with black line)
(Red) Muting lamp output (Yellow) Override input (Pale purple) Interlock setting input (Brown) +V (Pink) Test input / Reset input (Gray) Safety input 1 (Gray / Black) Safety input 2 (Shield) Output polarity setting wire (Blue) 0 V (Yellow-green / Black) Auxiliary output (Orange) Synchronization + (Orange / Black) Synchronization – (Orange / Black) Synchronization – (Orange) Synchronization + (Yellow-green) External device monitoring input (Brown) +V (Black) Control output 1 (OSSD 1) K1 (White) Control output 2 (OSSD 2) K2 (Shield) Output polarity setting wire (Blue) 0 V (Sky-blue / White) Muting input 1 (Sky-blue / Black) Muting input 2 (Gray) Large multi-purpose indicator input 1 (Gray / Black) Large multi-purpose indicator input 2
Open Open Open
Receiver
+ –
Emitter
24 V DC %
+10 –15
Gray cable Gray cable (with black line)
Open Open Open Open K1, K2: Force-guided relay or magnet contactor
Interlock function External device monitoring function Auxiliary output Output polarity setting wire Safety input
Disabled (Automatic reset) Disabled Not used PNP Invalid
PRECAUTIONS FOR PROPER USE • When this device is used in the “PSDI mode”, an appropriate control circuit must be configured between this device and the machinery. For details, be sure to refer to the standards or regulations applicable in each region or country. • This catalog is a guide to select a suitable product. Be sure to read instruction manual prior to its use. • Both emitter and receiver are adjusted before shipment, please apply both emitter and receiver with the same serial No. The serial No. is indicated on the plates of both emitter and receiver. (Indicated under model No.) • Make sure to carry out the test run before regular operation. • Do not install this safety light curtain with a machine whose operation cannot be stopped immediately in the middle of an operation cycle by an emergency stop equipment.
(Red) Muting lamp output (Yellow) Override input (Pale purple) Interlock setting input (Brown) +V (Shield) Output polarity setting wire (Gray) Safety input 1 (Gray / Black) Safety input 2 (Pink) Test input / Reset input (Blue) 0 V (Yellow-green / Black) Auxiliary output (Orange) Synchronization + (Orange / Black) Synchronization – (Orange / Black) Synchronization – (Orange) Synchronization + (Yellow-green) External device monitoring input (Brown) +V (Black) Control output 1 (OSSD 1) K1 (White) Control output 2 (OSSD 2) K2 (Shield) Output polarity setting wire (Blue) 0 V (Sky-blue / White) Muting input 1 (Sky-blue / Black) Muting input 2 (Gray) Large multi-purpose indicator input 1 (Gray / Black) Large multi-purpose indicator input 2
Open Open Open
+ –
24 V DC %
+10 –15
Open Open Open Open K1, K2: Force-guided relay or magnet contactor
Interlock function External device monitoring function Auxiliary output Output polarity setting wire Safety input
Disabled (Automatic reset) Disabled Not used NPN Invalid
Refer to the instruction manual for details. The instruction manual can be download from our website.
Others • This device has been developed / produced for industrial use only. • Do not use during the initial transient time (2 sec.) after the power supply is switched on. • Avoid dust, dirt and steam. • Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. • Take care that the sensor is not directly exposed to fluorescent lamp from a rapid-starter lamp or a high frequency lighting device, as it may affect the sensing performance. Handy-controller This safety light curtain enables to set each function using the handy-controller SFC-HC (optional). Among the functions, the contents related to the safety distance such as the size of the minimum sensing object and response time are varied depending on the setting condition. When setting each function, re-calculate the safety distance, and make enough space larger than the calculated safety distance. Failure to do so might cause the accident that the device cannot stop quickly before reaching the dangerous area of the machinery, resulting in the serious injury or death. • Refer to the instruction manual of the handy-controller for details of the function settings for using handycontroller SFC-HC (optional).
SF4C SERIES
Ultra-slim Safety Light Curtain Type 4
・
DIMENSIONS (Unit: mm in)
592
The CAD data can be downloaded from our website.・
SF4C-F□ SF4C-H□
Safety light curtain
Mounting drawing for the safety light curtains using the standard mounting brackets MS-SFC-1 (accessory). 7.7 (0.303 )
30 1.181
10 0.394
5.4 0.213
(
)
18 0.709 Indicator part (Note)
DCB A
5.4 0.213
(
)
18 0.709 Indicator part (Note)
13 0.512
13.2 0.520 t 2 t 0.079
21 0.827
7.7 (0.303 )
30 1.181
12 0.472 Indicator part (Note)
13 0.512
21 (0.827 )
50.5 (1.988 )
50.5 (1.988 )
50.5 (1.988 )
88 (3.465 )
DCB A
88 (3.465 )
Large Multi-purpose indicator
Large Multi-purpose indicator
Beam pitch
Beam pitch
F
F
G Gray cable
16 10 0.630 0.394
Emitter
88 (3.465 )
Large Multi-purpose indicator
E
(
88 3.465
Large Multi-purpose indicator
)
13.2 0.520 t 2 t 0.079
21 0.827
13 0.512
18 (0.709 )
21 (0.827 )
Large Multi-purpose indicator
16 10 0.630 0.394
7.7 (0.303 )
30 1.181
21 (0.827 )
88 (3.465 )
MICRO PHOTOELECTRIC SENSORS
13.2 0.520 t 2 t 0.079 10 0.394
Beam pitch
18 (0.709 )
Gray cable (with black line)
10 0.394 Gray cable
Receiver
Emitter
7.7 (0.303 )
12 0.472 Indicator part (Note)
50.5 (1.988 )
88 (3.465 )
BA
Large Multi-purpose indicator
E
88 (3.465 )
Large Multi-purpose indicator
Beam pitch
F
G
30 1.181
13.2 0.520 t 2 t 0.079
13 0.512
88 (3.465 )
Large Multi-purpose indicator
SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS
PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS
F 10 0.394
G
AREA SENSORS
INDUCTIVE PROXIMITY SENSORS
21 0.827
AB
LASER SENSORS PHOTOELECTRIC SENSORS
Mounting bracket assembly dimensions
FIBER SENSORS
G Gray cable (with black line)
STATIC CONTROL DEVICES LASER MARKERS
Receiver PLC HUMAN MACHINE INTERFACES
Connector of the pigtailed type SF4C-F□-J05 / SF4C-H□-J05 45 (1.772 )
FA COMPONENTS ø15.6 ø0.614
ø6 ø0.236
Model No.
A
B
C
D
E
Model No.
ENERGY MANAGEMENT SOLUTIONS
MACHINE VISION SYSTEMS UV CURING SYSTEMS
F
G Selection Guide
SF4C-F15(-J05)
SF4C-H8(-J05)
140 5.512 160 6.299 172 6.772 184 7.244 130 5.118
SF4C-F□(-J05) 10 0.394
SF4C-F23(-J05)
SF4C-H12(-J05) 220 8.661 240 9.449 252 9.921 264 10.394 210 8.268
SF4C-H□(-J05) 20 0.787
SF4C-F31(-J05)
SF4C-H16(-J05) 300 11.811 320 12.598 332 13.071 344 13.543 290 11.417
Safety Control Units
SF4C-F39(-J05)
SF4C-H20(-J05) 380 14.961 400 15.748 412 16.220 424 16.693 370 14.567
Safety Components
SF4C-F47(-J05)
SF4C-H24(-J05) 460 18.110 480 18.898 492 19.370 504 19.842 450 17.717
SF4C-F55(-J05)
SF4C-H28(-J05) 540 21.260 560 22.047 572 22.520 584 22.992 530 20.866
SF4C-F63(-J05)
SF4C-H32(-J05) 620 24.409 640 25.197 652 25.669 664 26.142 610 24.016
Note: Measurement of drawing above is display section of SF4C-H□. In case of SF4C-F□, the position of digital error indicator (red) is different as lower figure. Also, digital error indicator (red) is not incorporated in SF4C-F15□ (-J05).
<SF4C-H□> <SF4C-F□>
ø5 ø0.197
Safety Light Curtains
SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights
Digital error indicator
593
Ultra-slim Safety Light Curtain Type 4
・
DIMENSIONS (Unit: mm in)
FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS
SF4C SERIES
The CAD data can be downloaded from our website.・
SF4C-F□ SF4C-H□
Safety light curtain
Mounting bracket assembly dimensions
MICRO PHOTOELECTRIC SENSORS
Mounting drawing for the safety light curtains using the versatile brackets MS-SFC-C3 (optional) and intermediate supporting bracket for versatile brackets MS-SFC-F4 (optional).
AREA SENSORS
( )
( )
7.5 0.295
SAFETY LIGHT CURTAINS / SAFETY COMPONENTS
2 0.079
15 ( 0.591 )
PRESSURE / FLOW SENSORS
7.5 0.295
MS-SFC-3
Large Multi-purpose indicator
PARTICULAR USE SENSORS SENSOR OPTIONS
PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS
D A C
6.5 0.256
Large Multi-purpose indicator
WIRE-SAVING SYSTEMS
LASER MARKERS
8 0.315
B
21 0.827
12.7 0.500
15 ( 0.591 ) 7.5 ( 0.295 )
6.5 0.256 2 0.079
25.7 1.012
30 1.181 42 1.654
Emitter Model No.
SF4C-F23(-J05)
SF4C-H12(-J05)
–
SF4C-F31(-J05)
SF4C-H16(-J05)
–
SF4C-F39(-J05)
SF4C-H20(-J05)
–
SF4C-F47(-J05)
SF4C-H24(-J05)
–
SF4C-F55(-J05)
SF4C-H28(-J05)
Available
SF4C-F63(-J05)
SF4C-H32(-J05)
Available
SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights
12.7 0.500
(22 0.866)
Large Multipurpose indicator
8 0.315
Large Multipurpose indicator MS-SFC-4
D
MS-SFC-4
6.5 0.256 2 0.079
25.7 1.012
Inter mediate supporting bracket
MACHINE VISION SYSTEMS
Safety Components
MS-SFC-3
Large Multipurpose indicator
30 1.181
6.5 0.256 8 0.315 21 0.827
6.5 0.256
Large Multi-purpose indicator
MS-SFC-4 A’ 6.5 0.256
D
A’
B’
B’ (22 0.866) 30 1.181 42 1.654
2 0.079 12.7 0.500 25.7 1.021
42 1.654
Receiver
–
Safety Control Units
21 0.827
15 ( 0.591 ) 7.5 ( 0.295 )
SF4C-H8(-J05)
Safety Light Curtains
MS-SFC-3
(22 0.866) 30 1.181 42 1.654
SF4C-F15(-J05)
Selection Guide
2 0.079 6.5 0.256
Large Multi-purpose indicator
6.5 0.256
B
FA COMPONENTS
UV CURING SYSTEMS
MS-SFC-3
Large Multi-purpose indicator MS-SFC-4
D A C
SIMPLE WIRE-SAVING UNITS
STATIC CONTROL DEVICES
15 ( 0.591 )
(22 0.866)
INDUCTIVE PROXIMITY SENSORS
MEASUREMENT SENSORS
6.5 0.256
Emitter
12.7 0.500 25.7 1.021
Receiver
A
A'
B
B'
C
D
175 6.890 255 10.039 335 13.189 415 16.339 495 19.488 575 22.638 655 25.787
116 4.567 196 7.717 276 10.866 356 14.016 436 17.165 516 20.315 596 23.465
–
–
–
–
–
–
–
–
–
–
238 to 338 9.370 to 13.307 278 to 378 10.945 to 14.882
209 to 309 8.228 to 12.165 249 to 349 9.803 to 13.740
190 7.480 270 10.630 350 13.780 430 16.929 510 20.079 590 23.228 670 26.378
160 6.299 240 9.449 320 12.598 400 15.748 480 18.898 560 22.047 640 25.197
Note: Be sure to mount MS-SFC-4 when using SF4C-F55(-J05), SF4C-F63(-J05), SF4C-H28(-J05) and SF4C-H32(-J05).
8 0.315 21 0.827
6.5 0.256 2 0.079
Ultra-slim Safety Light Curtain Type 4
・
DIMENSIONS (Unit: mm in) MS-SFC-1
MS-SFC-2
NA2-N compatible mounting bracket (Optional)
30 1.181
t2 t 0.079
6 0.236
10 0.394
7.5 0.295 5 0.197
21 34 0.827 1.339
37 1.457 22.5 0.886
Mounting hole for M3 countersunk screw (for main body mounting)
Versatile bracket (Optional)
(
6 0.236
5 0.197
6.5 0.256
(
)
13 (0.512 )
)
3 0.118
LASER MARKERS
14.5 0.571
t1.5 t0.059
M3 countersunk screw mounting hole (for main body mounting) (3 0.118)
(3 0.118)
PLC HUMAN MACHINE INTERFACES
(6 0.236)
7.5 0.295
21.5 0.846
22.5 37 0.886 1.457
M3 countersunk screw mounting hole (for main body mounting)
(13 0.512)
5 0.197 2 0.079 18 0.709 30 1.181
t2 t0.079
Material: Stainless steel (SUS304) Net weight: 75 g approx. (4 pcs.) Package weight: 90 g appox.
7 0.276
6.5 0.256
MEASUREMENT SENSORS STATIC CONTROL DEVICES
30 1.181 18 0.709 2 0.079
INDUCTIVE PROXIMITY SENSORS
WIRE-SAVING SYSTEMS
MS-SFC-3
14.5 0.571
PRESSURE / FLOW SENSORS
SIMPLE WIRE-SAVING UNITS
Four bracket set Four M3 (length 4 mm 0.157 in) countersunk screws are attached.
SAFETY LIGHT CURTAINS / SAFETY COMPONENTS
SENSOR OPTIONS
Material: Stainless steel (SUS304) Net weight: 36 g approx. (4 pcs.) Package weight: 40 g appox.
Four bracket set Four M3 (length 4 mm 0.157 in) countersunk screws are attached.
AREA SENSORS
PARTICULAR USE SENSORS
Mounting hole for M3 countersunk screw (for main body mounting)
Material: Stainless steel (SUS304) Net weight: 32 g approx. (4 pcs.) Package weight: 35 g appox.
LASER SENSORS
MICRO PHOTOELECTRIC SENSORS
18 0.709 2 0.079
14.8 6.5 0.583 0.256
FIBER SENSORS
PHOTOELECTRIC SENSORS
30 1.181
2 × ø4.5 ø0.177
11.8 5.4 0.465 0.213
2-ø4.5 ø0.177
594
The CAD data can be downloaded from our website.・
Standard mounting bracket (Accessory)
t2 t 0.079
SF4C SERIES
2-ø4.5 ø0.177
23 0.906 t1.5 t0.059
t2 t0.079
ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS
Four bracket set Four M3 (length 4 mm 0.157 in) countersunk screws are attached.
MS-SFC-4
Intermediate supporting bracket for versatile bracket (Optional) 43.5 1.713
27.3 1.075
Safety Components
10.5 0.413
13.6 ( 0.535 )
SF4D
9.7 0.382 t2 t0.079
Safety Light Curtains Safety Control Units
27 1.063 (31 1.220)
Selection Guide
SF4B/ SF4B-G 8 0.315
SF4B-C
6 0.236
SF4C 6.5 0.256
6.5 0.256
10 0.394 20 25 0.787 0.984
BSF4-AH80 SF2B SF2C
Material: Stainless steel (SUS304) Net weight: 40 g approx. (2 pcs.) Package weight: 60 g appox. Two bracket set
27 1.063 37 1.457
3 ( 0.118 )
Definition of Sensing Heights
595 ・
FIBER SENSORS LASER SENSORS
Ultra-slim Safety Light Curtain Type 4
SF4C SERIES
DIMENSIONS (Unit: mm in)
The CAD data can be downloaded from our website.・
MS-SFCH-□
Metal protection case (Optional)
PHOTOELECTRIC SENSORS
Assembly dimensions Mounting drawing for the safety light curtains using the metal protection case (MS-SFCH-□).
MICRO PHOTOELECTRIC SENSORS AREA SENSORS
18 0.709
ø6.4 ø0.252 (M6 mounting hole)
SAFETY LIGHT CURTAINS / SAFETY COMPONENTS
36.2 1.425
(When using MS-SFC-2) ø5.4 ø0.213 (M5 mounting hole)
PRESSURE / FLOW SENSORS
Indicator part
PARTICULAR USE SENSORS
26 1.024
SENSOR OPTIONS
10 0.394 3 0.118
SIMPLE WIRE-SAVING UNITS
90 3.543
WIRE-SAVING SYSTEMS
STATIC CONTROL DEVICES
43.5 1.713
E
96 3.780 43.5 1.713
6 0.236
8 0.315
F
LASER MARKERS
26 1.024
HUMAN MACHINE INTERFACES
(When using MS-SFC-2)
MS-SFCH-8 MS-SFCH-12
Safety Control Units
MS-SFCH-16 MS-SFCH-20
SF4D
MS-SFCH-24
SF4B/ SF4B-G
MS-SFCH-28
BSF4-AH80 SF2B SF2C Definition of Sensing Heights
MS-SFCH-32
A
ø5.4 ø0.213 (M5 mounting hole)
4-ø4.8 ø0.189 (M4 mounting hole) (When using MS-SFC-2)
18 0.709
t2.3 t0.091
Safety Light Curtains
D
(When using MS-SFC-1)
Material: Aluminum
Model No.
SF4C
A
36.2 1.425
MACHINE VISION SYSTEMS
SF4B-C
B
26 1.024
FA COMPONENTS
Safety Components
C
5 0.197
5 0.197
ø6.4 ø0.252 (M6 mounting hole)
19.6 0.772
ENERGY MANAGEMENT SOLUTIONS
Selection Guide
D
ø5.4 ø0.213 (M5 mounting hole) (When using MS-SFC-1)
PLC
UV CURING SYSTEMS
ø5.4 ø0.213 (M5 mounting hole) (When using MS-SFC-1)
(When using MS-SFC-1)
INDUCTIVE PROXIMITY SENSORS
MEASUREMENT SENSORS
19.6 0.772
A
B
C
D
E
F
Net weight (2 pcs.)
190 7.480 270 10.630 350 13.780 430 16.929 510 20.079 590 23.228 670 26.378
180 7.087 260 10.236 340 13.386 420 16.535 500 19.685 580 22.835 660 25.984
175 6.890 255 10.039 335 13.189 415 16.339 495 19.488 575 22.638 655 25.787
172 6.772 252 9.921 332 13.071 412 16.220 492 19.370 572 22.520 652 25.669
162 6.378 242 9.528 322 12.677 402 15.827 482 18.976 562 22.126 642 25.276
26 1.024 35 1.378 35 1.378 35 1.378 35 1.378 35 1.378 35 1.378
160 g approx. 240 g approx. 340 g approx. 420 g approx. 520 g approx. 600 g approx. 700 g approx.
Ultra-slim Safety Light Curtain Type 4
・
DIMENSIONS (Unit: mm in) SFB-CC□-MU
SFB-CCJ□-MU
Mating cable with connectors on both ends (Optional)
45 (1.772 )
L
• Length L
ø6 ø0.236
AREA SENSORS
• Length L
SAFETY LIGHT CURTAINS / SAFETY COMPONENTS
Model No.
Length L
Length L
SFB-CC3-MU
3,000 118.110
SFB-CCJ3D-MU
SFB-CC7-MU
7,000 275.590
SFB-CCJ3E-MU
10,000 393.700
SFB-CCJ10D-MU
SFB-CC10-MU
3,000 118.110
SFB-CCJ10E-MU
SFC-WY1
Y-shaped connector (Optional)
WY1-CCN3 WY1-CCN10
66 2.598
22.5 0.886 13.5 0.531
(
41 1.614
42 1.654
)
10,000 393.700
Mating cable (Optional) L
INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS
SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES
ø6 ø0.236
ø9 ø0.354
PRESSURE / FLOW SENSORS
SENSOR OPTIONS
ø14 ø0.551
ø14 46.6 31 ø0.551 1.835 1.220
LASER SENSORS
MICRO PHOTOELECTRIC SENSORS
ø15.6 ø0.614
ø6 ø0.236
FIBER SENSORS
PHOTOELECTRIC SENSORS
45 (1.772 )
L
ø15.6 ø0.614
ø15.6 ø0.614
Model No.
596
The CAD data can be downloaded from our website.・
Mating cable with connector on one end (Optional) 45 (1.772 )
SF4C SERIES
LASER MARKERS
Model No.
Length L
WY1-CCN3
3,000 118.110
WY1-CCN10
10,000 393.700
PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS
SFC-HC
Handy-controller (Optional) 65 2.559
25.4 1.000
SF-C13
Control unit (Optional)
30 1.181
6.75 0.266
4 0.157 23 0.906
35 1.378 67.3 2.650
ø6 ø0.236 cables, 0.5 m 1.640 ft long
130 5.118
MACHINE VISION SYSTEMS
5 0.197
6 0.236
3 × 5 = 15 3 × 0.197 = 0.591 Selection Guide
91.6 3.606
Safety Light Curtains Safety Control Units
140 5.512 ENTER
UV CURING SYSTEMS
34.5 1.358
FUNCTION
CANCEL
FA COMPONENTS
10 0.394 13.5 0.531
80 3.150 6.5 80.8 0.256 3.181 Suitable for 35 mm 1.378 in width DIN rail
13 0.512
22.5 0.886
5 0.197
Safety Components
SF4D SF4B/ SF4B-G SF4B-C SF4C BSF4-AH80 SF2B SF2C Definition of Sensing Heights