Ex ten to
AC
ha fP se 1
2
P Q +32.365 SSL
04
N
SH EE T
00 60
2O F
100
AD
BLOCK J CORE 3 KEY PLAN 1:500 GENERAL NOTES:
SSL - Structural Slab Level CFFL - Constructed Finish Floor Level (excluding finishes eg:carpet or tiles) AFFL - Actual Finish Floor Level (including finishes eg:carpet or tiles) All dimensions are in millimetres unless otherwise noted. Dimensions are to the centre of structural walls and stud walls. All dimensions are to be checked on site. Structural Design: For design & setting out of all structural elements i.e. Foundations, ground & transfer slabs, columns, beams, shaft walls and slab penetrations etc. are to be taken from the Structural Engineer's drawings & working details.
02
B-B
Services Design: For setting out of incoming & outgoing services i.e. SVPs, Gas, Water and Electrical Intakes and Telecoms etc. refer to M&E Engineers & Structural Engineers drawings & working details.
A-A
This drawing must be read in conjunction with all relevant Specification documents. Specific drawing information can be found under the following drawing series:Site Information 27935-02 Plans 27935-03 27935-04 Sections Elevations 27935-05 27935-20 Structure Plans External Wall Details 27935-21 Internal Wall Details 27935-22 Balcony & Terrace Details 27935-21 & 36 Stair Details 27935-24 Windows 27935-31 Door Types & Details 27935-32 Floor Details 27935-33 Finishes 27935-40 Lift Setting-out & Services 27935-50 Signage 27935-71 Kitchens 27935-73 Bathrooms 27935-74 External Works 27935-90
AE
+32.365 SSL
LEGEND: Detail Reference
Section Reference Refers to Drawing Series & Drawing Number
04-001
01
21-001
01
A-A
Refers to Detail Reference
01
Refers to Section Reference
General Arrangement Floor Plan Notes: MJ = Movement Joint SJ = Soft Joint
+32.365 SSL
Refer to Optimisation & 40 series drawings for additional symbol definitions.
+32.365 SSL Alumasc Harmer Two-Way Rainwater Outlet
+32.365 SSL
AF
250 x 200 Aperture for Alumasc Harmer Balcony Outlet
200 x 200 Aperture for RWP/SVP
01
RWP/SVP above to be offset Floor Gully Location
Brise Soleil in roof overhang with 200 mm ppc aluminium blades. Colour RAL 7015 Fall
+32.365 SSL
Concrete
03
Beam above or other where specified on the drawing.
01
Etched glass enclosure 1.5m height to MAOV equipment. Dimensions to be checked on site prior to manufacturing.
NOTE:- SSL LEVELS INDICTED. FOR ROOF FFL ADD 120MM INSULATION
Blockwork Brickwork. Stone
+32.440 SSL
MAOV 03
Etched glass privacy screen 1.8m height fixed to existing roof. Measurements to be confirmed on site.
3 deg
+32.455 SSL
Glazed Rooflight SSL 32.220
Fall
AG
Brise Soleil in roof overhang with 200 mm ppc aluminium blades. Colour RAL 7015 +32.365 SSL +32.365 SSL +32.365 SSL
The as built information for J1 shown on this drawing is based on as built drawings prepared by a third party and Broadway Malyan Limited accept no responsibility for the accuracy or completeness of the as built information.
+32.365 SSL
AH
B-B
100
101
102
C-C
103
INITIAL
DESCRIPTION
DATE
FOR CONSTRUCTION
01
104
105
CONTINUED ON SHEET 1 OF 2 - Dwg no.: 27935-A03-J2-3-027
10
REV
3 Weybridge Business Park Addlestone Road Weybridge, Surrey KT15 2BW T: +44 (0)1932 845 599 F: +44 (0)1932 856 206 E:
[email protected] London/Madrid/Lisbon/Warsaw/ Abu Dhabi/Dubai/Singapore/ Shanghai/Manchester/Birmingham/ Edinburgh/Liverpool/Reading/ Weybridge www.BroadwayMalyan.com
ST.GEORGE CENTRAL LONDON LTD. ST.GEORGE HOUSE 17-19 IMPERIAL ROAD FULHAM SW6 2AN TELEPHONE:020 7471 4444 FAX:020 7471 4440
CHELSEA CREEK BLOCK J2 CORE 3
GENERAL ARRANGEMENT ROOF FLOOR PLAN SHEET 2 of 2 1:50 @ A0
RR
27935-A-03-J2-3-028
19/11/10 06
U :\ 2 7 9 3 5 \ I s s u e d \ I ss u e d to A r d m o r e \ 1 1 0 9 2 9 - R e v i s e d R o o f P l a n s - C o n s t r u c ti o n I s s u e \ 2 7 9 3 5 - A - 0 3 - J 2 - 3 - 0 2 8 r e v 0 6 . d w g