Split System Submittal Data

Split System Submittal Data System: E18RKUA Indoor: CS-E18RKUAW Outdoor: CU-E18RKUA Job Name: Location: Engineer: Submitted to: Submitted by: Reference:

Approval: Date: Construction: Unit#: Drawing#:

General Data Power (V/P/Hz) Circuit Ampacity (A) Fuse Size, Max.(A) Compressor No. Used Motor Type (No. of poles) Output Power

230/208/1/60 15 20 DC Twin Rotary (Inverter) 1 DC Brushless (4 poles) 1700

Outdoor Unit Fan Type No. Speeds Type Drive No. Poles (RPM) No. Motors (W) CFM (Hi speed) Coil Type Fin Type - Pipe Type Rows x stage x F.P.I. Size (W x H x L) Tube Size (in.)

Propeller Variable speed Direct / DC Brushless Motor 8-700 1-60 1925 Aluminum Fin and Copper Pipe Coated Corrugated fin - Inner Rifled 2 x 36 x 19 1-13/32 x 29-25/32 x 34-7/32 9/32

Indoor Unit Fan Type Motor Type, No. of Poles No. Speeds RPM (Cool / Heat), High No. Motors (W) CFM (Qlo/Lo/Me/Hi/SHi) Cooling CFM (Qlo/Lo/Me/Hi/SHi) Heating Operating Sound-Hi/Me/Lo/ dB-A (Cool) Operating Sound-Hi/Me/Lo/ dB-A (Heat) Coil Type Fin Type - Pipe Type Row x stage x FPI Size Tube Size (in.) Drain Connection Size (in.) Refrigerant Oz. - R410a (outdoor unit) Refrigerant Control Refrigerant Tubing Connections

Cross Flow DC Brushless, 8 poles Variable speed 1,480 / 1,500 1-94.8 469/513/592/670/720 508/553/622/695/740 47/39/36 46/39/36 Aluminum Plate Fin & Copper Tube Coated Slit Plate - Inner Rifled 2 x 15 x 21 1 x 12-13/32 x 31-7/8 9/32” 3/4” R410A 56.5 Electronic Expansion Valve Flare

Line Length, Max (ft.) Elevation Difference, Max (ft.) Line Size (in. O.D. Discharge) Line Size (in. O.D. Suction) Pre-charge, tubing length at shipment Dimensions (HxWxD) Indoor Unit (Crated) (in.) Indoor Unit (Uncrated) (in.) Outdoor Unit (Crated) (in.) Outdoor Unit (Uncrated) (in.) Weight (lbs.) (Indoor) Net (Indoor) Shipping (Outdoor) Net (Outdoor) Shipping

100.0 49.2 1/4” 1/2” 32.8’

14-17//32 x 45-11/16 x 11-9/32 11-7/16 x 42-5/32 x 9-15/32 34-25/32 x 41-5/16 x 19-1/8 31-5/16 x 34-15/32 x 12-5/8 26 31 132 146

Performance Data @ ARI Standard Conditions

Features

Cooling Total Capacity (BTU/H) Sensible Capacity (BTU/H) Latent Capacity (BTU/H) SEER Dehumidification (Pints/H) Amps (A) Power Inputs (W) Outdoor Sound Rating (dB-A) Heating Total Capacity (BTU/H) HSPF Amps (A) Power Inputs (W) Outdoor Sounds Rating (dB-A)

Controls Remote Controller

Panasonic North America Air Conditioning Division 1690 Roberts Blvd., NW, Suite 110 Kennesaw, GA 30144 us.panasonic.com/aircon

17,200 (5,800-19,800) 15,990 1210 19.5 3.0 6.3 1300 49 21,600 (5,800-22,00) 10.0 8.3 1750 51

Wired Remote Controller Temperature Control Timer Quiet mode High Power mode Air Louver, Horizontal Air Louver, Vertical Power Failure Automatic Restart Heating/Cooling Automatic Changeover Self-Diagnosis Air Filter

Microprocessor LCD Wireless Type included as standard Optional CZ-RD516C-1 IC Thermistor Single Event Daily ON/OFF TIMER Included Included Automatic, Sweep, Step Automatic, Sweep, Step Built-In Built-In Built-In Washable, One-touch

Operating Range

Indoor Air Intake Temp

Outdoor Air Intake Temp

Cooling (Max) Cooling (Min) Heating (Max) Heating (Min)

89.6F DB/73.4F WB 60.8F DB/51.8F WB 86.0F DB 60.8DB

114.8F DB 0F DB 75.2F DB/64.4F WB -4.0F DB/-5.8F WB

4. Dimensions

Indoor 4.1 Dimensions Indoor Unit

FPO

Outdoor Dimensions

8