Specplus SPS2GFSVA432 2' x 4' Recessed Fluorescent, Lens Frame Troffer Static, 4 Lamp T8 or T5
Page 1 of 2
Features • • • • • • • • • • • • • • • •
5" deep body. 3-1/16" lamp to lens for better lamp obscuration. 81.2% efficient. Clean contoured interior. One-piece housing has ribbed construction for added strength. Hemmed over side rails for maximum safety. Fixture ends turned-in for safe handling. Built-in earthquake clips. Slimline door frame with 1000 square inch lens opening. Door jamb finished black on four sides for positive light stop. True mitered corner steel lens frame. Spring loaded rooster head latches. 18 gauge steel hinges. Flat and regressed aluminum doors available. Sky lens options avalible. Construction to meet NYC Code or Chicago Plenum requirements is available.
Mounting Methods G
Standard VA Lens
Optional Sky Lens
Dimensions
exposed T-grid ceiling. (with flat aluminum frame)
F
plaster ceiling/flanged. (with regressed aluminum frame)
5" (127mm) Plaster Opening 24-1/8"
1/4" max.
1-1/8" min. 3-3/4" max.
1-1/2" max.
15/16" or 1"
24"
6" (152mm)
2" x 2-1/2" access plate with two K.O.s (7/8" dia.)
exposed T-grid ceiling (with flat steel frame)
drywall kit (see options)
Type “G” FIxture
13/16"
24-11/16"
24" (610mm)
Support (by others) Drywall Kit (See Options) Drywall (by others)
Order Catalog Number: FK92X4.
1/4" max. 1-1/2" max.
24"
15/16" or 1" 39-1/4" (997mm) 47-31/32" (1218mm)
Job Information Type: Job Name:
earthquake clip before installation
earthquake clip installed (lay-in grid)
Cat. No.:
Lamp(s):
Volts/Ballast:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 02/10 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © Philips Group Section 1A/Folio E60-34 Rev. B
Specplus SPS2GFSVA432 2' x 4' Recessed Fluorescent, Lens Frame Troffer Static, 4 Lamp T8 or T5
Page 2 of 2
Photometry
Sky Lens Options
Model No. SPS2GFSVA43212004 LER = FP - 73.2 IW - 108.7 BF - 0.86 Comparative yearly lighting energy cost per 1000 lumens = $3.28 Report Number: ITL49786 Catalog Number: SPS2GFSVA43212004 Lamps: (4) F32T8 Luminaire: 2' x 4' SpecPlus with regressed aluminum door frame and extruded virgin acrylic shielding .095" nominal thickness (similar to pattern 12). Ballast: E423PI120G11 Report is based on 2850 Lumens per lamp. Efficiency: 81.2% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.000 21.875
70 89 82 75 69 64 59 55 51 48 45
80 50 85 75 67 60 54 49 44 40 37 34
30 82 70 61 53 47 42 37 34 31 28
50 80 71 63 57 51 46 42 39 36 33
50 30 78 67 58 51 45 41 36 33 30 28
10 76 64 54 47 41 36 32 29 26 24
50 77 68 61 55 50 45 41 38 35 32
30 30 75 65 57 50 44 40 36 33 30 27
0.0
45.0
90.0
0
3690
3690
3690
FLUX
5
3673
3678
3685
350
15
3546
3580
3612
1012
25
3270
3353
3430
1545
35
2814
2948
3056
1839
45
2192
2316
2457
1784
55
1410
1515
1613
1349
65
770
765
853
790
75
440
335
390
420
85
178
152
139
168
90
0
0
0
S2
LUMINANCE DATA IN CANDELA/SQ. METER AVERAGE AVERAGE AVERAGE AVERAGE IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 4773. 5043. 5351. 55 3785. 4067. 4330. 65 2806. 2787. 3108. 75 2618. 2112. 2320. 85 3145. 2685. 2456.
COEFFICIENTS OF UTILIZATION – ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC RW 01 02 03 04 05 06 07 08 09 10
S1 CANDELA DISTRIBUTION
10 73 62 53 46 41 36 32 29 26 24
ZONAL LUMEN SUMMARY ZONE 00-030 00-040 00-060 00-090 90-180 00-180
LUMENS % LAMP 2906 25.5 4745 41.6 7878 69.1 9257 81.2 0000 0.0 9257 81.2
% FIXT 31.4 51.3 85.1 100.0 000.0 100.0
Ordering Information Explanation of Catalog Number. Example: SPS2GFSVA432UNVH4
Specplus: Recessed fluorescent troffer
S
2
Static
Fixture Width
4 Ceiling Type: G= Grid (lay-in T bar) F= Flanged (over lap) Z spline and plaster frame
SP
Standard Specplus Plus
SX
For NYC Code – Local 3 Manufactured
Lens Frame: FS = Flat steel frame. RA= Regressed aluminum frame. FA = Flat aluminum frame.
Lens Shielding Type: VA=Virgin acrylic (standard) S1=Sky lens 1 S2=Sky lens 2 See options and consult factory
Lamp Quantity
Lamp Type/ Fixture Length: 32=32W T8 28=28W T5 54=54W T5 (Nominal 48")
Options/Accessories Special Lenses: Substitute VY for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average weight per square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz. average weight per square foot. Substitute S1 or S2 for VA (standard) = Sky Acrylic Lens (see Sky Lens sell sheet for further details). Plaster Frame: Catalog Number: PF24. Continuous Row Installation: For F type fixtures, half width flanges are required between fixtures. Order Catalog Number: 2FC TRIM CSP (each joint). Radio Interference Filter: To order one RIF per fixture; SUFFIX: R. To order one RIF per ballast; SUFFIX: B. Fusing: Internal fast-blow fusing. SUFFIX A. Internal slow-blow fusing. SUFFIX C. Electrical Wiring Options: Consult factory. Drywall Kit: Order Catalog Number: FK92X4. (Request Folio OA30-10 Rev. A). Chicago Plenum: SUFFIX: C.
Specifications Performance: In an installation of 4 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .85. To prevent glare the VCP shall be not less than 43 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 3108 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 68.6%.
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 02/10 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © Philips Group Section 1A/Folio E60-34 Rev. B
Voltage: 120, 277 or UNV=120-277
Options: Add appropriate suffix to catalog no., ie: (A)
Ballast Type: < 20THD < 10THD 2-2 Lamp Elec. T8 SO * HI * 1-4 Lamp Elec. T8 O4 * H4 * 2-2 Lamp 28W Elec. T5 – PI † 2-2 Lamp 28W Elec. T5 – †PG †† 1-4 Lamp 54W Elec. T5 – †PV †† LOL T8 Dimming PS – Other dimming options. Consult factory. †*Instant Start Standard ††Instant Start (120, 277 or UNV) ††Program Rapid Start (UNV only) NOTE: For T8 UNV, you must use HI, H4 Ballast Code.
Specifications (continued) Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing with side rails hemmed over and housing ends turned-in for safe handling. Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Lenses: VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge, .095" nominal thickness (similar to pattern 12). VY (optional) .125" nominal pattern 12 with 7.8 oz. average weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. average weight per square foot. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W. UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Job Information
Type: