Submittal #3.0 22 4200 - Institutional Plumbing Fixtures HITT Contracting Inc. 2900 Fairview Park Drive Falls Church, Virginia 22042 Phone: (703) 846-9000 Fax: (703) 846-9110
Project: 45841 - 1401 K Street 1401 K Street Northwest Washington, District of Columbia 20005
TRANSMITTAL Urinal Product Data
SPEC SECTION:
22 4200 - Institutional Plumbing Fixtures
CREATED BY:
Fidel Hernandez(HITT Contracting Inc. - HQ)
STATUS:
Submitted
DATE CREATED:
11/30/2015
ISSUE DATE:
11/30/2015
REVISION:
0
RESPONSIBLE CONTRACTOR:
Dominion Mechanical Contractor Inc
RECEIVED FROM:
Joseph Caldwell
RECEIVED DATE: //
SUBMIT BY:
FINAL DUE DATE: 12/14/2015
LOCATION:
TYPE:
COST CODE:
APPROVERS:
Chris Wiley (Beyer Blinder Belle Architects & Planners, LLP)
BALL IN COURT: Chris Wiley (Beyer Blinder Belle Architects & Planne) DISTRIBUTION: Chris Wiley (Beyer Blinder Belle Architects & Planner), Greg Kochalski (First Potomac Realty Trust), Pete Hohm (First Potomac Management, LLC), Fidel Hernandez (HITT Contracting Inc. - HQ), Jennie Gwin (Beyer Blinder Belle Architects & Planner), Ricky Dolly (HITT Contracting Inc. HQ), Todd Daniel (HITT Contracting Inc. - HQ) DESCRIPTION: ATTACHMENTS:
SUBMITTAL WORKFLOW NAME
SENT DATE
RETURNED DATE
Chris Wiley
BY
HITT Contracting Inc.
RESPONSE
ATTACHMENTS
COMMENTS
Pending
DATE
COPIES TO
Page 1 of 2
Printed On: 11/30/2015 10:58 AM
2900 Fairview Park Drive HITT Contracting Inc. Falls Church, Virginia 22042
SUBMITTAL COVER SHEET 1401 K Street
Owner:
General Contractor: HITT Contracting
Designer:
Subcontractor: Dominion Mechanical Contractor Inc
MEP Engineer:
Interior Designer:
Structural Engineer:
Submittal
Rev.
Description
Submitted For:
3
0
Urinal Product Data
Review & Approval
General Contractor's Approval:
Engineer's Approval:
Architect's Approval:
Consultant's Approval:
PROJECT # 6206.00 ✔ A B C
HITT CONTRACTING INC 1401 K STREET
REVIEWED
REVIEWED AS CORRECTED
REVISE AND RESUBMIT
REJECTED
FOR INFORMATION ONLY
Reviewed in accordance with AIA 201 and the Contract Documents. This submittal is in full compliance with the Construction Documents except as explicitly noted.
BY: Fidel Hernandez
DATE: 11/30/2015
SUBMITTAL #
DESCRIPTION
3 Urinal Product Data
3307 M STREET, NW, SUITE 301 WASHINGTON, DC 20007 202 333 8000 SHOP DWG FILE #
SUBM.
REVIEWED BY
DATE RETURNED
SPEC #
Chris Wiley
224200
3
0
12/4/2015
SUBMITTAL REVIEWED FOR DESIGN AND GENERAL ARRANGEMENT ONLY AND IS SUBJECT TO CONTRACT DOCUMENTS. IT IS THE CONTRACTOR’S RESPONSIBILITY TO COORDINATE WITH ALL TRADES AND TO CHECK QUANTITIES & DIMENSIONS AGAINST FIELD CONDITIONS. CONTRACTORS SHALL ALSO REMAIN RESPONSIBLE FOR FABRICATION PROCESSES AND
DESCRIPTION FABRICATION, MANUFACTURE OR CONSTRUCTION MAY PROCEED, PROVIDING SUBMITTAL COMPLIES WITH CONTRACT DOCUMENTS. FABRICATION, MANUFACTURE OR CONSTRUCTION MAY PROCEED PROVIDING SUBMITTAL COMPLIES WITH ARCHITECT’S NOTATIONS AND CONTRACT DOCUMENTS. IF, FOR ANY REASON, CONTRACTOR CANNOT COMPLY WITH THE NOTATIONS, CONTRACTOR SHALL RESUBMIT. FABRICATION, MANUFACTURE OR CONSTRUCTION MAY NOT PROCEED. SUBMITTAL DOES NOT COMPLY WITH THE CONTRACT DOCUMENTS. RESUBMIT.
CONTRACTOR NOTE: ACTION CHECKED ABOVE DOES NOT AUTHORIZE CHANGES TO CONTRACT SUM OR CONTRACT TIMES UNLESS STATED IN SEPARATE LETTER OR CONSTRUCTION CHANGE AUTHORIZATION.
Submittal Review Project Name & Address: 1401 K Street, NW, Renovation Project No.: 6345-14 Mechanical Contractor: Dominion Mechanical Manufacturer: Zurn Item Submitted: Plumbing Fixture (Urinal Only) - #3 Specification Section: 22 4200 Submittal Status: No Exceptions Taken JPA Reviewer: CNR Date: 12/04/15 Items to be corrected: 1. No exceptions taken.
SUBMITTAL REVIEW STATUS A: No Exceptions Taken
D: Rejected/Resubmit
B: Note Markings and Confirm
E: Comments Attached
C: Amend and Resubmit
F:
Engineer’s review is for general conformance with the design concept and for general compliance with the information given on contract documents. Markings of comments shall not be construed as relieving the Contractor from compliance with the project plans and specifications, nor departure therefrom. The Contractor remains responsible for details, coordination and accuracy, for confirming and correlating all quantities and dimensions, for selecting fabrication processes, for techniques of assembly and for performing work in a safe manner. James Posey Associates, Inc. By: CNR 3112 Lord Baltimore Drive Baltimore, MD 21244 tel fax
410-265-6100 410-298-9820
jamesposey.com
Consulting Engineers Date: Dec 04, 2015
Z5758.205.00 ®
TAG ®
"The Retrofit Pint " 1/8 gpf, EcoVantage , Ultra Low Consumption, Battery Powered Urinal System Z5758.205.00 Series • Zurn One ultra low consumption urinal system designed for optimal performance between Zurn fixture and Zurn flush valve to save water while exceeding industry performance standards • 1/8 gallons per flush [0.5 Liters per flush] • Vitreous china • High efficiency washout flushing action • Over 88% water savings over standard 1.0 gpf [4.0 Lpf] system • Pressure compensating internal flow regulator • Manual override flush activator button • Universal Bracket and oversized footprint to make retro-fit easy • 3/4" top spud • 2" I.P.S. outlet flange and rubber gasket with integral trap • 14" extended rim for handicap compliance when installed at proper height • Vandal resistant outlet strainer included • Shipping Weight: 72 lbs.
Z5758.205.00 Series These dimensions and specifications are subject to change without notice. Fixture dimensions meet ANSI/ASME standards A112.19.2 and CAN/CSA B45 requirements. Meets the American Disabilities Guidelines and ANSI A117.1 requirements when urinal is installed 17" [432 mm] from finished floor.
ENGINEERING SPECIFICATION: Z5758.205.00 EcoVantage® High Efficiency Urinal (HEU) System - System comes complete with sensor operated, battery powered, exposed ZTR6203-ULF high efficiency flushometer valve and vitreous china urinal. The system is designed to perform to industry standards with as little as 1/ 8th gallon per flush. Valve is operated by an infrared convergence-type proximity sensor with smart technology, powered by 4 "AA" batteries, furnished with vandal resistant chrome plated metal housing, chloramine resistant internal seals, and reversible cover. Valve features a manual override flush activator button, an internal flow regulator to maintain constant flow rates independent of line pressures and an in-line filter to protect the valve from debris within the water. Complete with high pressure vacuum breaker, one piece hex coupling nut, adjustable tailpiece, spud coupling and flange for top spud connection. Control stop has internal siphon-guard protection, vandal resistant stop cap, sweat solder kit, and a cast wall flange with set screw. Vitreous china urinal is supplied with 3/4" top spud, 2" outlet connection, vandal resistant outlet strainer and universal retrofit hanger bracket.
Architectural/Engineering Approval
ZURN INDUSTRIES, LLC. ♦ COMMERCIAL BRASS OPERATION ♦ 5900 ELWIN BUCHANAN DRIVE ♦ SANFORD NC 27330 Phone: 1-800-997-3876 ♦ Fax: 919-775-3541 ♦ World Wide Web: www.zurn.com In Canada: ZURN INDUSTRIES LIMITED ♦ 3544 Nashua Drive ♦ Mississauga, Ontario L4V1L2 ♦ Phone: 905-405-8272 Fax: 905-405-1292 ®
®
EcoVantage and The Pint are registered trademarks of Zurn Industries, LLC.
Rev. C Dwg. No. 83922
Date: 10/29/2014 Product No. Z5758.205.00
Z5758.205.00
TAG
®
®
"The Retrofit Pint " 1/8 gpf, EcoVantage , Ultra Low Consumption, Battery Powered Urinal System
Rough-in dimensions for Z5758.205.00 series 14 [356] 1 [286] 114 1 2 [13] TYP. SLOT SPACING
4 [102] 434 +1/2 [121+13] -
1 [210] 84 1 [387] 154
5 [67] 28
7 [123] 48
UNIVERSAL RETROFIT BRACKET (UB) MANUAL OVERRIDE BUTTON
3/4 [19] VACUUM 111 [292] 2 BREAKER TUBE
3 [76]
2181 [537] MAX 1 [361] 144
C.L. OUTLET
2 [51]
1881
[460] MIN
1 [470] 182 1 [83] 34
417 8 [1064] 24 [610] (17 [432] ADA)
203 4 [527] 3 134 [349] ADA
29 [737]
1 [140] 52
FINISHED WALL FINISHED FLOOR
These dimensions and specifications are subject to change without notice. Fixture dimensions meet ANSI/ASME standards A112.19.2 and CAN/CSA B45 requirements. Meets the American Disabilities Guidelines and ANSI A117.1 requirements when urinal is installed 17" [432 mm] from finished floor. ZURN INDUSTRIES, LLC. ♦ COMMERCIAL BRASS OPERATION ♦ 5900 ELWIN BUCHANAN DRIVE ♦ SANFORD NC 27330 Phone: 1-800-997-3876 ♦ Fax: 919-775-3541 ♦ World Wide Web: www.zurn.com In Canada: ZURN INDUSTRIES LIMITED ♦ 3544 Nashua Drive ♦ Mississauga, Ontario L4V1L2 ♦ Phone: 905-405-8272 Fax: 905-405-1292 ®
®
EcoVantage and The Pint are registered trademarks of Zurn Industries, LLC.
Rev. C Dwg. No. 83922
Date: 10/29/2014 Product No. Z5758.205.00