Submittal Data - PEX Universe

Report 9 Downloads 112 Views
Submittal Data Information

101-084

Model 0011-IFC® Cartridge Circulator

Effective: April 22, 2010

Features

s)NTEGRAL&LOW#HECK)&#®) Prevents gravity flow Eliminates separate in-line flow check Reduces installed cost, easy to service Improved performance vs. In-line flow checks s5NIQUEREPLACEABLECARTRIDGE &IELDSERVICEABLE s5NMATCHEDRELIABILITY -AINTENANCEFREE s1UIET EFFICIENTOPERATION s$IRECTDRIVE ,OWPOWERCONSUMPTION s3ELFLUBRICATING .OMECHANICALSEAL s3TANDARDHIGHCAPACITYOUTPUT #OMPACTDESIGN s7IDERANGEOFAPPLICATIONS s#AST)RONOR3TAINLESS3TEELCONSTRUCTION Flanged connections

Materials of Construction

#ASING6OLUTE  #AST)RONOR3TAINLESS3TEEL Integral Flow Check: Body, Plunger....Acetal / RING3EALS%0$- Spring.................Stainless Steel Stator Housing: Aluminum Cartridge: Stainless Steel )MPELLER .ON -ETALLIC Shaft: Ceramic Bearings: Carbon / 2ING'ASKETS%0$-

Model Nomenclature

F – Cast Iron, Flanged SF – Stainless Steel, Flanged IFC – Integral Flow Check

Variations:

Z – Zoning Circulator J – Bronze Cartridge with Cast Iron Casing

IMP. DIA.

For Indoor use only

HEAD/FT.

H.P.

ELEC. CHAR.

Application

The 0011-IFC with an Integral Flow Check is designed to reduce installation costs when zoning with 00® circulators on large residential or light commercial high head / medium flow applications such as hydronic or radiant heating, hydro-air fan coils, indirect water heaters or domestic water recirculation systems. By locating the removable, spring-loaded IFC inside the pump casing, a separate in-line flow check is eliminated, reducing installation costs. The reduced pressure drop of the IFC increases the 0011 flow performance over in-line check valves. Both the IFC and cartridge are easily accessed for service instead of replacing the entire unit. Our patented Priority Zoning circulator with built-in transformer, relay, priority switch and IFC in one complete, compact package makes it ideal for zoning.

Pump Dimensions & Weights !"#$ & '3HIP7T -ODELCasing in. mm in. mm in. mm in. mm in. mm in. mm lbs. Kg 0011-F4-2 IFC 0011-SF4-IFC 0011-ZF4-1 IFC 0011-ZSF4-IFC

Iron    St. Steel      Iron   St. Steel

 13

6.0

Mounting Positions

Standard

-ODEL 6OLTS (Z 0H !MPS 20- !LL-ODELS

Optional

OK if over 20 psi

Flange Orientation

Electrical Data (0

 

-OTOR0ERMANENT3PLIT#APACITOR Type Impedance Protected -OTOR     Options

Performance Field - 60Hz

INTEGRAL FLOWCHECK (IFC ) MODELS ®

FLOW-M3/H

TOTAL HEAD-FEET

Performance Data

&LOW2ANGE '0Head Range: 0 - 31 Feet -INIMUM&LUID4EMPERATUREƒ&ƒ# -AXIMUM&LUID4EMPERATUREª&ƒ# -AXIMUM7ORKING0RESSUREPSI Connection Sizes: 3/4”, 1”, 1-1/4”, 1-1/2” Flanged

G.P.M.

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 11.0 36 10.5 34 009-IFC 10.0 32 0010-IFC 9.5 0011-IFC 30 9.0 0012-IFC 28 8.5 0013-IFC 8.0 26 0014-IFC 7.5 24 7.0 22 6.5 20 6.0 5.5 18 5.0 16 4.5 14 4.0 12 3.5 10 3.0 2.5 8 2.0 6 1.5 4 1.0 2 0.5 0 0.0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44

TOTAL HEAD-METERS

MODEL NO.

Rep:

Contractor:

®

ITEM NO.

Supersedes: June 27, 2007 Effective: 04/22/10

Submittal Data # 101-084 Supersedes: 06/27/07

Submittal Data Information Job: Engineer: Circulator Model 0011-IFC Cartridge

FLOW-GPM

.3&šn,EAD Complies with California Health and Safety #ODE3ECTION!"AND Vermont Act 193

Do it Once. Do it Right.®

TACO INC., 1160 Cranston Street, Cranston, RI 02920 Telephone: (401) 942-8000 Fax: 942-2360 TACO (Canada), Ltd., 6180 Ordan Drive, Mississauga, Ontario L5T 2B3 Telephone: (905) 564-9422 Fax: (905) 564-9436 Visit our website at: www.taco-hvac.com Taco Inc., 1160 Cranston Street. Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360 Taco (Canada) Ltd., 8450 Lawson Road, Unit #3, Milton, Ontario L9T 0J8 / (905) 564-9422 / Fax (905) 564-9436 www.taco-hvac.com

Printed in USA Copyright 2010 TACO, Inc.