Submittal Data Information
101-085
Model 0010-IFC® Cartridge Circulator
Effective: August 2, 2011 ®
Rep:
MODEL NO.
Features
s)NTEGRAL&LOW#HECK)®) Prevents gravity flow Eliminates separate in-line flow check Reduces installed cost, easy to service Improved performance vs. In-line flow checks s5NIQUEREPLACEABLECARTRIDGE &IELDSERVICEABLE s5NMATCHEDRELIABILITY -AINTENANCEFREE s1UIET EFFICIENTOPERATION s$IRECTDRIVE ,OWPOWERCONSUMPTION s3ELFLUBRICATING .OMECHANICALSEAL s3TANDARDHIGHCAPACITYOUTPUT #OMPACTDESIGN s7IDERANGEOFAPPLICATIONS s#AST)RONOR3TAINLESS3TEELCONSTRUCTION Flanged connections
Materials of Construction
#AST)RONOR 304 Stainless Steel Integral Flow Check: Body, Plunger....Acetal / RING 3EALS%0$- Spring.................Stainless Steel Stator Housing: Aluminum Cartridge: Stainless Steel )MPELLER .ON -ETALLIC Shaft: Ceramic Bearings: Carbon / 2ING'ASKETS%0$-
Application
The 0010-IFC with an Integral Flow Check is designed to reduce installation costs when zoning with 00® circulators. Ideal for residential or light commercial hydronic or radiant heating, hydro-air fan coils, indirect water heaters or domestic water recirculation systems. By locating the IFC inside the pump casing, a separate in-line flow check is eliminated, reducing installation costs. The reduced pressure drop of the IFC increases the flow performance over in-line check valves. Both the IFC and cartridge are easily accessed for service instead of replacing the entire unit. Our patented Priority Zoning Circulator with built-in transformer, relay, priority switch and optional IFC in one complete, compact package makes it ideal for zoning. Available in Cast Iron or Stainless Steel construction.
Pump Dimensions & Weights -ODEL#ASING
#ASING6OLUTE
Model Nomenclature
F – Cast Iron, Flanged SF – 304 Stainless Steel, Flanged IFC – Integral Flow Check
Variations:
Z – Zoning Circulator J – Bronze Cartridge with Cast Iron Casing
B
C
D
F
G
3HIP7T
mm
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
lbs. Kg
7-1/4 7-1/4 7-1/4 7-1/4
184 184 184 184
5-5/16 5-5/16 5-5/16 5-5/16
135 135 135 135
3-3/16 3-3/16 3-3/16 3-3/16
81 81 81 81
3-5/16 3-5/16 3-13/16 3-13/16
84 84 97 97
5-3/8 5-3/8 5-7/8 5-7/8
137 137 150 150
6-3/8 6-3/8 6-3/8 6-3/8
162 162 162 162
10 9 11 10
D
4.5 4.0 5.0 4.5
Mounting Positions
A B C
G
Standard
D
Optional
OK if over 20 psi
F
Electrical Data
Flange Orientation
-ODEL 6OLTS (Z 0H !MPS 20- Cast Iron Stainless Steel
115
60
1
1.10 1.17
3250
(0 1/8
-OTOR0ERMANENT3PLIT#APACITOR Type Impedance Protected -OTOR 220/50/1, 220/60/1, 100/110/50/60/1 Options
Performance Field - 60Hz INTEGRAL FLOWCHECK (IFC ) MODELS ®
FLOW-M3/H
TOTAL HEAD-FEET
Performance Data &LOW2ANGE '0Head Range: 0 - 9 Feet -INIMUM&LUID4EMPERATURE&# -AXIMUM&LUID4EMPERATUREª&# -AXIMUM7ORKING0RESSUREPSI Connection Sizes: 3/4”, 1”, 1-1/4”, 1-1/2” Flanged
Iron St.Steel Iron St.Steel
0010-F3-1 IFC 0010-SF3-IFC 0010-ZF3-1 IFC 0010-ZSF3-IFC
A in.
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 11.0 36 10.5 34 009-IFC 10.0 32 0010-IFC 9.5 0011-IFC 30 9.0 0012-IFC 28 8.5 0013-IFC 8.0 26 0014-IFC 7.5 24 7.0 22 6.5 20 6.0 5.5 18 5.0 16 4.5 14 4.0 12 3.5 10 3.0 2.5 8 2.0 6 1.5 4 1.0 2 0.5 0 0.0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44
TOTAL HEAD-METERS
ITEM NO.
Supersedes: june 29, 200J08/02/11 Effective:
Submittal Data # 101-085 Supersedes: 06/29/07 Contractor:
Submittal Data Information Job: Engineer: Model 0010-IFC Cartridge Circulator
FLOW-GPM
For Indoor use only TACO INC., 1160 Cranston Street, Cranston, RI 02920 Telephone: (401) 942-8000 Fax: 942-2360 .3&n,EAD TACO (Canada), Ltd., 6180 Ordan Drive, Mississauga, Ontario L5T 2B3 Telephone: (905) 564-9422 withat:California Health and Safety VisitComplies our website www.taco-hvac.com
Code Section 116875 / AB1953
Fax: (905) 564-9436
Printed in USA Copyright 2011 TACO, Inc.