FCC Part 18 Subpart C Consumer For RF Lighting Equipment Electromagnetic Compatibility Test Report
Sunlight Supply, Inc.
902249 Sun System 1 600 Watt Etelligent Compatible Ballast - 120-240 Volt July 19, 2017
Tests Conducted by: ElectroMagnetic Investigations, LLC 20811 NW Cornell Road, Suite 600, Hillsboro, Oregon 97124, USA Tele (503) 466-1160 Fax (503) 466-1170
[email protected] EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 1 of 23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
Revision History Authorizations
3 3
Test Summary Information .............................................................5 Device Under Test Information
7
Emissions Test Report .........................................................................8 Radiated Emissions Information ....................................................9 Purpose DUT Modifications Radiated Emissions Results Auxiliary Equipment in measurement area Auxiliary Equipment outside measurement area Cables Measurement Bandwidths Radiated Emission Plots Radiated Emissions Photographs
10 10 11 11 11 11 11 12 14
Conducted Emissions Information ................................................16 Purpose DUT Modifications Conducted Emissions Results Auxiliary Equipment in measurement area Auxiliary Equipment outside measurement area Cables Measurement Bandwidths Conducted Emission Plots Conducted Emissions Photographs
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
17 17 18 18 18 18 18 19 22
Page 2 of 23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
• • • •
The Equipment was tested in the configuration and modes of operation provided by the client. Test levels were specified by the client within the test plan. Any additional tests not reported herein are the responsibility of the client as the overall product compliance is the responsibility of the client. This report may only be reproduced in its entirety. To reproduce this report in part, specific written permission must be obtained from ElectroMagnetic Investigations. The results presented in this test report pertain only to the test items described within this report. Specific test descriptions can be found in the specific individual section of the test report.
Deviations to the Test Standard No Deviations were made to the standard test methods
Revision History Version
Date Issued
Description of Revision
Authorizations FCC: The 3-meter Semi-Anechoic Chamber and Conducted Emissions facilities are fully described in reports filed with the Federal Communications Commission. Corresponding letters of acceptance are maintained in our files. Industry Canada: measurements.
Accepted by Industry Canada for performance of radiated emissions
European Union (CE): ElectroMagnetic Investigations, LLC is equipped and capable of performing EMC CE compliance testing to European Union EMC CE requirements for Information Technology Equipment (ITE), Measurement, Control and Laboratory Equipment (MCL), and other equipment. American Association of Lab Accreditations (A2LA): ElectroMagnetic Investigations is accredited to perform the tests contained within this report to the standards listed.
Certificate #2569.01
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 3 of 23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
Report Approved By:
_____________________________
19 JULY 2017 Date
Henry Benitez Name
18 JULY 2017 Date
Jackie Benitez Name
_____________________________ Signature
12 JULY 2017 Date
Ryan Benitez Name
_____________________________ Signature
Date
___________ Name
Signature
Report Written By:
_____________________________ Signature
Testing Performed By:
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 4 of 23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
Test Summary Information Report Number: Issue Date: Test Item: Serial Number: Power Supply:
SUN20170629-02 July 18, 2017 902249 Sun System 1 600 Watt Etelligent Compatible Ballast - 120-240 Volt
Not Provided Internal
Emissions: Result
Product Standard
Test Standard
Pass
FCC Part 18 Subpart C Consumer
FCC Part 18 Subpart C Section 18.305c Consumer rf lighting devices
Pass
FCC Part 18 Subpart C Consumer
FCC Part 18 Subpart C Section 18.307c Consumer rf lighting devices
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Description
Radiated Emissions
Conducted Emissions
Page 5 of 23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
Device Under Test Selection Justification Sunlight Supply Inc. certifies that product tested is a representative sample of units to be sold. I, ___________________, representative for Sunlight Supply Inc. verify that the product tested is representative of units to be sold.
____________________ (Signature)
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 6 of 23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
Testing requested by: Company Name:
Sunlight Supply Inc.
Company Address:
5408 NE 88th St, Bldg A
City, State Zip:
Vancouver, WA 98665
Test Requested By:
Bruce LeBlanc, Caleb Doerr
Model:
902249 Sun System 1 600W Etelligent Compatible 120-240 Volt Ballast
First Date of Test:
July 10, 2017
Last Date of Test:
July 12, 2017
Date Samples Received:
July 10, 2017
Equipment Design Stage:
Production Representative
Equipment Condition:
Good
Device Under Test Information
Clock Frequencies (>9kHz)
902249 Sun System 1 600W Etelligent Compatible 120-240 Volt Ballast 902249 Sun System 1 600W Etelligent Compatible 120-240 Volt Ballast N/A Tested with 901526 Ultra Sun HPS 600 Watt single ended bulb in Sun System Magnum XXXL 6” reflector (P/N 904520) for HPS/MH 600W Ballast Not Provided
Modes of Operation
600W
Operating System
N/A
Exercising Software
N/A
Power Supply Voltage, Frequency
120 V 60 Hz
Device Under Test Functional Description of DUT I/O Ports Test Configuration
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 7 of 23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
Emissions Test Report
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 8 of 23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
Radiated Emissions Information The client provided the test modes, configurations, and operational settings for the DUT and any supporting equipment. The DUT and the AE that is designated to be placed in the measurement area were placed on a non-conducting tabletop 80 cm tall. Each device is placed on the tabletop 10 cm from its neighboring device. The excess cable length was draped off the rear of the table. If the excess cable fell closer than 40 cm from the ground plane, the cable was bundled in non-inductive bundles of 30-40 cm loops (when possible) to maintain 40 cm in height. The measurement antenna was then placed 3 m from the closest approach of the DUT/AE system. Any AE that had to be placed outside the measurement area was setup either outside of the chamber or under the floor, depending on size and convenience. The DUT and the AE were operated in the modes specified by the client while the emissions were measured. To measure the emissions at the frequency range specified in this report, a preliminary scan was performed with a linearly polarized antenna while the turntable was rotated 360 degrees and the antenna mast was raised from 1 meter height to 4 meters in height in both a horizontal polarization and a vertical polarization. Any emissions that were found to be within 6 dB of the specified limit were then maximized to find the level that was recorded. The maximization process included manual manipulation of the cables, continuous height scanning, and continuous azimuth scanning.
Device Under Test Functional Description of DUT Serial Number
902249 Sun System 1 600W Etelligent Compatible 120-240 Volt Ballast 902249 Sun System 1 600W Etelligent Compatible 120-240 Volt Ballast Not Provided
Clock Frequencies (>9kHz)
N/A Tested with 901526 Ultra Sun HPS 600 Watt single ended bulb in Sun System Magnum XXXL 6” reflector (P/N 904520) for HPS/MH 600W Ballast Not Provided
Modes of Operation
600W
Operating System (Version)
N/A
Exercising Software (version)
N/A
Power Supply Voltage, Frequency
120 V 60 Hz
Frequency Range Tested
30 MHz to 1000 MHz
I/O Ports Populated for test Test Configuration
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 9 of 23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
Purpose The purpose of the testing is to determine if the 902249 Sun System 1 600W Etelligent Compatible 120-240 Volt Ballast is compliant to radiated electromagnetic emission limits as specified by FCC Part 18 Subpart C Consumer. The testing was performed as per FCC measurement procedure MP-5.
DUT Modifications No Modifications were done to the DUT. No EMI suppression was added to the cabling. The DUT was tested as delivered to EMI.
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 10 of
23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
Radiated Emissions Results Product Standard: FCC Part 18 Subpart C Consumer Radiated Emissions: …………………………Emissions are within specification limits. Least Margin: ……………………………………………..……...3.7 dB at 57.6 MHz. Test Measurement uncertainties (k=2.05): Radiated Field strength at 3m measured with: Chase Bicon (30 MHz – 1 GHz)…………………………………… ±5.6 dB Sample radiated emissions field strength measurement: RF Reading from Spectrum Analyzer (dBuV) + Cable Loss Factor (dB) + Antenna Factor (dB) – PreAmplifier Amplification (dB) = Final Radiated Emission Level (dBuV/m).
Auxiliary Equipment in measurement area Device
Manufacturer
HPS 600 Watt Single Ended Bulb
Ultra Sun
Lamp Reflector
Sun System
Model Number 901526 Ultra Sun HPS 600 W Sun System Magnum XXXL 6” reflector (P/N 904520)
Serial Number None None
* Note: This includes all equipment connected to the DUT and located within the measurement area. Emissions from this equipment could increase the emissions measured.
Auxiliary Equipment outside measurement area Device
Manufacturer
Model Number
Serial Number
N/A
N/A
N/A
N/A
* Note: This includes all equipment isolated from the DUT and the measurement area. Emissions from this equipment will not increase the emissions measured.
Cables Type of Cable Lamp
Shield?
Length
Ferrite?
No
8 Feet
N/A
Shipped with Product? No
Connection 1
Connection 2
Ballast (DUT)
Lamp
Measurement Bandwidths Frequency (MHz) 0.15 – 30
Peak (kHz) 9.0
Quasi-Peak (kHz) 9.0
Average (kHz) 9.0
30 – 1000
120
120
120
>1000
1000
N/A
1000
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 11 of
23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
Radiated Emission Plots
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 12 of
23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 13 of
23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
Radiated Emissions Photographs
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 14 of
23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 15 of
23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
Conducted Emissions Information The client provided the test modes, configurations, and operational settings for the DUT and any supporting equipment. The DUT and the AE that is designated to be placed in the measurement area were placed on a non-conducting tabletop 80 cm tall. Each device is placed on the tabletop 10 cm from its neighboring device. The excess cable length was draped off the rear of the table. If the excess cable fell closer than 40 cm from the ground plane, the cable was bundled in non-inductive bundles of 30-40 cm loops (when possible) to maintain 40 cm in height. The measurement LISN was located on the floor at least 80 cm from the nearest approach of the DUT. The DUT and the AE were operated in the modes specified by the client while the emissions were measured. To measure the emissions at the frequency range specified in this report, cables were arranged in a manner to maximize emissions and a preliminary peak scan was performed. Any peaks found to be within 6 dB of the QP limit were remeasured using the QP detector. Device Under Test Functional Description of DUT Serial Number
902249 Sun System 1 600W Etelligent Compatible 120-240 Volt Ballast 902249 Sun System 1 600W Etelligent Compatible 120-240 Volt Ballast Not Provided
Clock Frequencies (>9kHz)
N/A Tested with 901526 Ultra Sun HPS 600 Watt single ended bulb in Sun System Magnum XXXL 6” reflector (P/N 904520) for HPS/MH 600W Ballast Not Provided
Modes of Operation
600W
Operating System (Version)
N/A
Exercising Software (version)
N/A
Power Supply Voltage, Frequency
120 V 60 Hz
Frequency Range Tested
150 kHz – 30 MHz
I/O Ports Populated for test Test Configuration
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 16 of
23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
Purpose The purpose of the testing is to determine if the 902249 Sun System 1 600W Etelligent Compatible 120-240 Volt Ballast is compliant to conducted electromagnetic emission limits as specified by FCC Part 18 Subpart C Consumer. The testing was performed as per FCC measurement procedure MP-5.
DUT Modifications No Modifications were done to the DUT. No EMI suppression was added to the cabling. The DUT was tested as delivered to EMI.
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 17 of
23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
Conducted Emissions Results Product Standard: FCC Part 18 Subpart C Consumer Conducted Emissions: ………………………… Emissions are within specification limits. Least Margin: ……………………………………………..……...5.7 dB at 12.7 MHz. Conducted Emissions Measurement System uncertainty (k=2.05)……………….. ±3.7 dB Sample conducted emissions measurement: RF Reading from Spectrum Analyzer (dBuV) + Cable Loss Factor (dB) +LISN Factor (dB) = Final Conducted Emission Level (dBuV).
Auxiliary Equipment in measurement area Device
Manufacturer
Model Number
Serial Number
HPS 600 Watt Single Ended Bulb
Ultra Sun
901526 Ultra Sun HPS 600 W
None
Lamp Reflector
Sun System
Sun System Magnum XXXL 6” reflector (P/N 904520)
None
* Note: This includes all equipment connected to the DUT and located within the measurement area. Emissions from this equipment could increase the emissions measured.
Auxiliary Equipment outside measurement area Device
Manufacturer
Model Number
Serial Number
N/A
N/A
N/A
N/A
* Note: This includes all equipment isolated from the DUT and the measurement area. Emissions from this equipment will not increase the emissions measured.
Cables Type of Cable Lamp
Shield?
Length
Ferrite?
No
8 Feet
N/A
Shipped with Product? No
Connection 1
Connection 2
Ballast (DUT)
Lamp
Measurement Bandwidths Frequency (MHz) 0.15 – 30
Peak (kHz) 9.0
Quasi-Peak (kHz) 9.0
Average (kHz) 9.0
30 – 1000
120
120
120
>1000
1000
N/A
1000
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 18 of
23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
Conducted Emission Plots
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 19 of
23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 20 of
23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 21 of
23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
Conducted Emissions Photographs
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 22 of
23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V
EMI4019.04
Report_ SUN20170629-02
Testing Report ElectroMagnetic Investigations
Page 23 of
23 902249 Sun System 1 600 Watt Etelligent Compatible Ballast120-240 V