FCC Part 18 Subpart C Consumer For RF Lighting Equipment Electromagnetic Compatibility Test Report
Sunlight Supply, Inc.
902243 Sun System One DE 1000W 120/240V June 12, 2017
Tests Conducted by: ElectroMagnetic Investigations, LLC 20811 NW Cornell Road, Suite 600, Hillsboro, Oregon 97124, USA Tele (503) 466-1160 Fax (503) 466-1170
[email protected] EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 1 of 23 902243 Sun System One DE 1000W 120/240V
Revision History Authorizations
3 3
Test Summary Information .......................................................... 5 Device Under Test Information
7
Emissions Test Report ..................................................................... 8 Radiated Emissions Information ................................................. 9 Purpose DUT Modifications Radiated Emissions Results Auxiliary Equipment in measurement area Auxiliary Equipment outside measurement area Cables Measurement Bandwidths Radiated Emission Plots Radiated Emissions Photographs
10 10 11 11 11 11 11 12 14
Conducted Emissions Information.............................................. 16 Purpose DUT Modifications Conducted Emissions Results Auxiliary Equipment in measurement area Auxiliary Equipment outside measurement area Cables Measurement Bandwidths Conducted Emission Plots Conducted Emissions Photographs
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
17 17 18 18 18 18 18 19 22
Page 2 of 23 902243 Sun System One DE 1000W 120/240V
• • • •
The Equipment was tested in the configuration and modes of operation provided by the client. Test levels were specified by the client within the test plan. Any additional tests not reported herein are the responsibility of the client as the overall product compliance is the responsibility of the client. This report may only be reproduced in its entirety. To reproduce this report in part, specific written permission must be obtained from ElectroMagnetic Investigations. The results presented in this test report pertain only to the test items described within this report. Specific test descriptions can be found in the specific individual section of the test report.
Deviations to the Test Standard No Deviations were made to the standard test methods
Revision History Version
Date Issued
Description of Revision
Authorizations FCC: The 3-meter Semi-Anechoic Chamber and Conducted Emissions facilities are fully described in reports filed with the Federal Communications Commission. Corresponding letters of acceptance are maintained in our files. Industry Canada: measurements.
Accepted by Industry Canada for performance of radiated emissions
European Union (CE): ElectroMagnetic Investigations, LLC is equipped and capable of performing EMC CE compliance testing to European Union EMC CE requirements for Information Technology Equipment (ITE), Measurement, Control and Laboratory Equipment (MCL), and other equipment. American Association of Lab Accreditations (A2LA): ElectroMagnetic Investigations is accredited to perform the tests contained within this report to the standards listed.
Certificate #2569.01
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 3 of 23 902243 Sun System One DE 1000W 120/240V
Report Approved By:
_____________________________
14 JUNE 2017 Date
Henry Benitez Name
12 JUNE 2017 Date
Jackie Benitez Name
_____________________________ Signature
06 JUNE 2017 Date
Ryan Benitez Name
_____________________________ Signature
Date
___________ Name
Signature
Report Written By:
_____________________________ Signature
Testing Performed By:
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 4 of 23 902243 Sun System One DE 1000W 120/240V
Test Summary Information Report Number: Issue Date: Test Item: Serial Number: Power Supply:
SUN20170601 June 12, 2017 902243 Sun System One DE 1000W 120/240V None Internal
Emissions: Result
Product Standard
Test Standard
Description
Pass
FCC Part 18 Subpart C Consumer
FCC Part 18 Subpart C Section 18.305c
Radiated Emissions
Pass
FCC Part 18 Subpart C Consumer
FCC Part 18 Subpart C Section 18.307c
Conducted Emissions
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 5 of 23 902243 Sun System One DE 1000W 120/240V
Device Under Test Selection Justification Sunlight Supply Inc. certifies that product tested is a representative sample of units to be sold. I, ___________________, representative for Sunlight Supply Inc. verify that the product tested is representative of units to be sold.
____________________ (Signature)
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 6 of 23 902243 Sun System One DE 1000W 120/240V
Testing requested by: Company Name:
Sunlight Supply Inc.
Company Address:
5408 NE 88th St, Bldg A
City, State Zip:
Vancouver, WA 98665
Test Requested By:
Bruce LeBlanc
Model:
902243 Sun 120/240V
First Date of Test:
June 06, 2017
Last Date of Test:
June 06, 2017
Date Samples Received:
June 05, 2017
Equipment Design Stage:
Production Representative
Equipment Condition:
Good
System
One
DE
1000W
Device Under Test Information Device Under Test Functional Description of DUT I/O Ports
902243 Sun System One DE 1000W 120/240V Digital Ballast 1000 Watt
Clock Frequencies (>9kHz)
N/A Tested with 901465 Digimax Double Ended HPS Lamp 1000 W in Sun System 904934 DE Boss Lamp Reflector. Tested on setting 120 V 60 Hz. Unknown
Modes of Operation
Power on at 1000 Watt setting
Operating System
N/A
Exercising Software
N/A
Power Supply Voltage, Frequency
120 V 60 Hz
Test Configuration
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 7 of 23 902243 Sun System One DE 1000W 120/240V
Emissions Test Report
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 8 of 23 902243 Sun System One DE 1000W 120/240V
Radiated Emissions Information The client provided the test modes, configurations, and operational settings for the DUT and any supporting equipment. The DUT and the AE that is designated to be placed in the measurement area were placed on a non-conducting tabletop 80 cm tall. Each device is placed on the tabletop 10 cm from its neighboring device. The excess cable length was draped off the rear of the table. If the excess cable fell closer than 40 cm from the ground plane, the cable was bundled in non-inductive bundles of 30-40 cm loops (when possible) to maintain 40 cm in height. The measurement antenna was then placed 3 m from the closest approach of the DUT/AE system. Any AE that had to be placed outside the measurement area was setup either outside of the chamber or under the floor, depending on size and convenience. The DUT and the AE were operated in the modes specified by the client while the emissions were measured. To measure the emissions at the frequency range specified in this report, a preliminary scan was performed with a linearly polarized antenna while the turntable was rotated 360 degrees and the antenna mast was raised from 1 meter height to 4 meters in height in both a horizontal polarization and a vertical polarization. Any emissions that were found to be within 6 dB of the specified limit were then maximized to find the level that was recorded. The maximization process included manual manipulation of the cables, continuous height scanning, and continuous azimuth scanning. Device Under Test
902243 Sun System One DE 1000W 120/240V
Functional Description of DUT
Digital Ballast 1000 Watt
Serial Number
None
I/O Ports Populated for test
Clock Frequencies (>9kHz)
N/A Tested with 901465 Digimax Double Ended HPS Lamp 1000 W in Sun System 904934 DE Boss Lamp Reflector. Tested on setting 120 V 60 Hz. Not Provided
Modes of Operation
Power on at 1000 Watt setting
Operating System (Version)
N/A
Exercising Software (version)
N/A
Power Supply Voltage, Frequency
120 V 60 Hz
Frequency Range Tested
30 MHz to 1000 MHz
Test Configuration
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 9 of 23 902243 Sun System One DE 1000W 120/240V
Purpose The purpose of the testing is to determine if the 902243 Sun System One DE 1000W 120/240V is compliant to radiated electromagnetic emission limits as specified by FCC Part 18 Subpart C Consumer. The testing was performed as per FCC measurement procedure MP-5.
DUT Modifications No Modifications were done to the DUT. No EMI suppression was added to the cabling. The DUT was tested as delivered to EMI.
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 10 of 23 902243 Sun System One DE 1000W 120/240V
Radiated Emissions Results Product Standard: FCC Part 18 Subpart C Consumer Radiated Emissions: …………………………Emissions are within specification limits. Least Margin: ……………………………………………..……...10 dB at 98 MHz. Test Measurement uncertainties (k=2.05): Radiated Field strength at 3m measured with: Chase Bicon (30 MHz – 1 GHz)…………………………………… ±5.6 dB Sample radiated emissions field strength measurement: RF Reading from Spectrum Analyzer (dBuV) + Cable Loss Factor (dB) + Antenna Factor (dB) – PreAmplifier Amplification (dB) = Final Radiated Emission Level (dBuV/m).
Auxiliary Equipment in measurement area Device
Manufacturer
Lamp Reflector
Sun System
1000 Watt Bulb
Digimax
Model Number 904934 DE Boss Lamp Reflector
Serial Number None
901465 Double Ended HPS Lamp 1000 W
None
* Note: This includes all equipment connected to the DUT and located within the measurement area. Emissions from this equipment could increase the emissions measured.
Auxiliary Equipment outside measurement area Device
Manufacturer
Model Number
Serial Number
N/A
N/A
N/A
N/A
* Note: This includes all equipment isolated from the DUT and the measurement area. Emissions from this equipment will not increase the emissions measured.
Cables Type of Cable
Shield?
Length
Ferrite?
Shipped with Product?
Connection 1
Connection 2
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Measurement Bandwidths Frequency (MHz) 0.15 – 30
Peak (kHz) 9.0
Quasi-Peak (kHz) 9.0
Average (kHz) 9.0
30 – 1000
120
120
120
>1000
1000
N/A
1000
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 11 of 23 902243 Sun System One DE 1000W 120/240V
Radiated Emission Plots
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 12 of 23 902243 Sun System One DE 1000W 120/240V
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 13 of 23 902243 Sun System One DE 1000W 120/240V
Radiated Emissions Photographs
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 14 of 23 902243 Sun System One DE 1000W 120/240V
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 15 of 23 902243 Sun System One DE 1000W 120/240V
Conducted Emissions Information The client provided the test modes, configurations, and operational settings for the DUT and any supporting equipment. The DUT and the AE that is designated to be placed in the measurement area were placed on a non-conducting tabletop 80 cm tall. Each device is placed on the tabletop 10 cm from its neighboring device. The excess cable length was draped off the rear of the table. If the excess cable fell closer than 40 cm from the ground plane, the cable was bundled in non-inductive bundles of 30-40 cm loops (when possible) to maintain 40 cm in height. The measurement LISN was located on the floor at least 80 cm from the nearest approach of the DUT. The DUT and the AE were operated in the modes specified by the client while the emissions were measured. To measure the emissions at the frequency range specified in this report, cables were arranged in a manner to maximize emissions and a preliminary peak scan was performed. Any peaks found to be within 6 dB of the QP limit were remeasured using the QP detector. Device Under Test
902243 Sun System One DE 1000W 120/240V
Functional Description of DUT
Digital Ballast 1000 Watt
Serial Number
Not Provided
I/O Ports Populated for test
Clock Frequencies (>9kHz)
N/A Tested with 901465 Digimax Double Ended HPS Lamp 1000 W in Sun System 904934 DE Boss Lamp Reflector. Tested on setting 120 V 60 Hz. Not Provided
Modes of Operation
Power on at 1000 Watt setting
Operating System (Version)
N/A
Exercising Software (version)
N/A
Power Supply Voltage, Frequency
120 V 60 Hz
Frequency Range Tested
150 kHz – 30 MHz
Test Configuration
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 16 of 23 902243 Sun System One DE 1000W 120/240V
Purpose The purpose of the testing is to determine if the 902243 Sun System One DE 1000W 120/240V is compliant to conducted electromagnetic emission limits as specified by FCC Part 18 Subpart C Consumer. The testing was performed as per FCC measurement procedure MP-5.
DUT Modifications No Modifications were done to the DUT. No EMI suppression was added to the cabling. The DUT was tested as delivered to EMI.
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 17 of 23 902243 Sun System One DE 1000W 120/240V
Conducted Emissions Results Product Standard: FCC Part 18 Subpart C Consumer Conducted Emissions: ………………………… Emissions are within specification limits. Least Margin: ……………………………………………..……...4.5 dB at 470 kHz. Conducted Emissions Measurement System uncertainty (k=2.05)……………….. ±3.7 dB Sample conducted emissions measurement: RF Reading from Spectrum Analyzer (dBuV) + Cable Loss Factor (dB) +LISN Factor (dB) = Final Conducted Emission Level (dBuV).
Auxiliary Equipment in measurement area Device
Manufacturer
Model Number
Serial Number
Lamp Reflector
Sun System
904934 DE Boss Lamp Reflector
None
1000 Watt Bulb
Digimax
901465 Double Ended HPS Lamp 1000 W
None
* Note: This includes all equipment connected to the DUT and located within the measurement area. Emissions from this equipment could increase the emissions measured.
Auxiliary Equipment outside measurement area Device
Manufacturer
Model Number
Serial Number
N/A
N/A
N/A
N/A
* Note: This includes all equipment isolated from the DUT and the measurement area. Emissions from this equipment will not increase the emissions measured.
Cables Type of Cable N/A
Shield?
Length
Ferrite?
N/A
N/A
N/A
Shipped with Product? N/A
Connection 1
Connection 2
N/A
N/A
Measurement Bandwidths Frequency (MHz) 0.15 – 30
Peak (kHz) 9.0
Quasi-Peak (kHz) 9.0
Average (kHz) 9.0
30 – 1000
120
120
120
>1000
1000
N/A
1000
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 18 of 23 902243 Sun System One DE 1000W 120/240V
Conducted Emission Plots
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 19 of 23 902243 Sun System One DE 1000W 120/240V
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 20 of 23 902243 Sun System One DE 1000W 120/240V
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 21 of 23 902243 Sun System One DE 1000W 120/240V
Conducted Emissions Photographs
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 22 of 23 902243 Sun System One DE 1000W 120/240V
EMI4019.04
Report_ SUN20170601
Testing Report ElectroMagnetic Investigations
Page 23 of 23 902243 Sun System One DE 1000W 120/240V