Tab 30 - Klockner Moeller

Report 10 Downloads 205 Views
30.3

Definite Purpose Contactors and Starters Starters

Contents

25–60A, Single- and Three-Phase—A25, B25

Description

Page

25–60A, Single- and Three-Phase—A25, B25 Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . . . . . Trip Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15–45A, Single- and Three-Phase—A27, B27 . . . . . . . . . . . 15–75A, Single- and Three-Phase—A30, B30 and C440/XT Electronic Overload Relay . . . . . . . . . . . . . . . . .

30 30

402 404 405 406 406 407 408 416

30 30 30 30 30 30 30 30 30

25–60A, Single- and Three-Phase—A25, B25 Product Description

Features and Benefits

Standards and Certifications

A25 and B25 Definite Purpose Starters from Eaton’s electrical sector combine the features and flexibility of the C25 Definite Purpose Contactors and Freedom Series Bi-metallic Ambient Compensated Overload Relays mounted on a common mounting plate.

Overload Relay ● Selectable manual or automatic reset operation ● Interchangeable heater packs adjustable ±24% to match motor FLA and calibrated for use with 1.0 and 1.15 service factor motors ● Class 10 or 20 heater packs ● Bimetallic, ambient compensated operated. Trip free mechanism ● Electrically isolated NO-NC contacts (pull RESET button to test) ● Overload trip indication ● Shrouded or fingerproof terminals to reduce possibility of electrical shock ● Single-phase sensitivity





30

UL Recognized Components UL File #E-1491, Guide NLDX2 CSA Certified Components File #LR353, Guide 380W-1.14 Class 3211 04

30 30 30 30 30 30 30 30

Catalog Number Selection

30

25–60A, Single- and Three-Phase—A25, B25

30

A25CNC30

30

A

30 Incomplete catalog number

Magnet coil suffix

30 When Ordering Specify ● Catalog number plus magnet coil suffix, see Page 402 Example, order catalog number A25CNC30A ● Heater packs for specific FLA of motor, see Pages 404 and 405

30 30 30 30 30

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

401

30.3 30 30

Definite Purpose Contactors and Starters Starters

Product Selection A25 Starter

30 30 30

Single- and Three-Phase Starters—Open Type

A25SNC25_

3

7-1/2

2.2

5.5

B25CNC25_

B25SNC25_

A25CNC25_

A25SNC25_

125



10



7.5

B25CNC25_

B25SNC25_

A25CNC25_

A25SNC25_

575

100



10



7.5

B25CNC25_

B25SNC25_

A25CNC25_

A25SNC25_

115

180

2



1.5



B25CNC30_

B25SNC30_

A25CNC30_

A25SNC30_

230

180

5

10

3.7

7.5

B25CNC30_

B25SNC30_

A25CNC30_

A25SNC30_

460

150



15



11

B25CNC30_

B25SNC30_

A25CNC30_

A25SNC30_

575

120



15



11

B25CNC30_

B25SNC30_

A25CNC30_

A25SNC30_

115

240

3



2.2



B25CNE40_

B25SNE40_

A25CNE40_

A25SNE40_

230

240

7-1/2

10

5.5

7.5

B25CNE40_

B25SNE40_

A25CNE40_

A25SNE40_

460

200



20



15

B25CNE40_

B25SNE40_

A25CNE40_

A25SNE40_

575

160



20



15

B25CNE40_

B25SNE40_

A25CNE40_

A25SNE40_

115

300









N/A

N/A

A25CNE50_

A25SNE50_

230

300



15



11

N/A

N/A

A25CNE50_

A25SNE50_

460

250



30



22

N/A

N/A

A25CNE50_

A25SNE50_

575

200



30



22

N/A

N/A

A25CNE50_

A25SNE50_

115

360









N/A

N/A

A25CNE60_

A25SNE60_

230

360



20



15

N/A

N/A

A25CNE60_

A25SNE60_

460

300



40



30

N/A

N/A

A25CNE60_

A25SNE60_

575

240



40



30

N/A

N/A

A25CNE60_

A25SNE60_

30 30 30

Magnet Coil Suffix

30

Voltage 60 Hertz

50 Hertz



Coil Suffix

AC 

30

A25CNC25_

150

60

30

B25SNC25_

460

30

30

B25CNC25_

230

50

30



2

30

30

1.5

150

30

30

Catalog Number 

115

40

30

Catalog Number 

25

30

30

Three-Phase  Common Separate Control Control

Locked Rotor

30

30

Single-Phase  Common Separate Control Control Catalog Catalog Number  Number 

Ampere Rating Inductive Line Full Load Voltage

30 30

Maximum Motor (kW) SingleThreePhase Phase

Maximum Motor (hp) SingleThreePhase Phase

Voltage 60 Hertz

Coil Suffix

DC 

12

12

R

12

24

24

T

24

1T

110–120 

110–120 

A

48

1W

120

1A

208–240

208–240

B

240 

220

J

277



H



380–415

L

440–480

440–480

C

550–600

550–600

D

1R

Notes  Starters do not include heater packs. Select heater pack from tables, see Pages 404 and 405.  Set of three heater packs required for single-phase applications.  Incomplete catalog number. Replace underscore (_) with magnet coil suffix from table above.  Class H AC coils available as option for 15A–50A contactor. Add 2 before AC coil suffix letter.  104–120V 50/60 Hz for 60A contactor.  Available through 50A.  Starters with DC coils include an early breaking auxiliary contact, C320KGD1. See Page 440 for more detail.

30 30 30 30 30 30 402

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

Definite Purpose Contactors and Starters Starters

30.3

Overload Relay General Overload relays are provided to protect motors, motor control apparatus and motorbranch circuit conductors against excessive heating due to motor overloads and failure to start. This definition does not include: 1) motor circuits over 600 volts, 2) short circuits, 3) ground faults and 4) fire pump control. (NEC Art. 430-31) Time Current Characteristics The time-current characteristics of an overload relay is an expression of performance which defines its operating time at various multiples of its current setting. Tests are run at Underwriters Laboratory (UL) in accordance with NEMA Standards and the NEC.

UL requires— ● When tested at 100 percent of its current rating, the overload relay shall trip ultimately ● When tested at 200 percent of its current rating, the overload relay shall trip in not more than 8 minutes ● When tested at 600 percent of its current rating, the overload relay shall trip in not more than 10 or 20 seconds, depending on the Class of the relay or heater packs “Current Rating” is defined as the minimum current at which the relay will trip. Per NEC, an overload must ultimately trip at 125% of FLA (Full Load Amperes) current (heater) setting for a 1.15 service factor motor and 115% FLA for a 1.0 service

factor motor.“Current Setting” is defined as the FLA of the motor and thus the overload heater pack setting. Example: 600% of current rating is defined as 750% (600 x 1.25) of FLA current (heater) setting for a 1.15 service factor motor. A 10 ampere heater setting must trip in 20 seconds or less at 75 amperes motor current for a Class 20 relay. Overload Relay Setting

For motors having a 1.0 service factor, rotate the FLA dial single-half position counterclockwise (CCW). Manual/Automatic Reset— The overload relay is factory set at M for manual reset operation. For automatic reset operation, turn the reset adjustment dial to the A position as shown in the illustration. Automatic reset is not intended for two-wire control devices.

30 30 30 30 30 30 30 30

FLA Dial Adjustment— For motors having a 1.15 service factor, rotate the FLA adjustment dial to correspond to the motor’s FLA rating. Estimate the dial position when the motor FLA falls between two letter values as shown in the example.

30

Test for Trip Indication— To test overload relay for trip indication when in manual reset, pull out the blue RESET button. An orange flag will appear indicating that the device has tripped. Push RESET button in to reset.

30 30 30 30 30

FLA Dial Adjustment

Reset Adjustment Dial

30

1.0 1.15 Service Service Factor Factor B A

30

C

30

A D

Example of 12.0 FLA setting for heater pack number H2011B showing position for 1.0 or 1.15 service factor motors.

M

30 30

Example of setting for manual reset.

30 30 30

Replacement Overload with Connectors Starter Size

Overload Part Number

25 and 30A

10-7125

40 and 50A

10-7132

60A

10-7131

30 30 30 30 30 30 30 30

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

403

30.3

Definite Purpose Contactors and Starters Starters

30

Accessories

30

Locking Cover for Overload Relay Snap-on transparent or opaque plastic panel for covering access port to the overload relay trip setting dial—helps prevent accidental or unauthorized changes to trip and reset setting.

30 30

Contactor Accessories, see Pages 389 and 390.

Locking Cover for Overload Relay

Locking Cover

30 30 30 30 30 30

Description

Minimum Order Quantity (Std. Pkg.)

Catalog Number

Clear cover, no accessibility

50

C320PC3

Gray cover, no accessibility, with auto only nib

50

C320PC4

Gray cover, no accessibility, with manual only nib

50

C320PC5

Gray cover with FLA dial accessibility, A, B, C, D positions and auto only nib

50

C320PC6

Gray cover with FLA dial accessibility, A, B, C, D positions and manual only nib

50

C320PC7

Separate Enclosures Separate Enclosures—NEMA 1

30

Application

Catalog Number

25 and 30A

C799B11

30

40, 50 and 60A

C799B13

30 30 30

Heater Packs Fast Trip—Class 10 Heater Packs Manual or Automatic Reset Heater packs are shipped three to a carton. Catalog numbers listed below are for three heater packs.

30

Fast Trip Ratings

30

Motor Full Load Ampere Rating  Dial Position A B C

D

Catalog Number  (Includes Three Heater Packs)

0.26

0.313

0.367

0.42

H2101B-3

30

0.384

0.464

0.543

0.623

H2102B-3

0.57

0.688

0.806

0.924

H2103B-3

30

0.846

1.02

1.2

1.37

H2104B-3

1.28

1.55

1.83

2.1

H2105B-3

30

1.92

2.33

2.74

3.15

H2106B-3

2.3

2.79

3.28

3.77

H2107B-3

3.38

4.1

4.82

5.54

H2108B-3

4.96

6.03

7.09

8.16

H2109B-3

7.07

8.58

10.1

11.6

H2110B-3

30

9.6

11.2

12.8

14.4

H2111B-3

14.4

17.5

20.7

23.8

H2112B-3

30

18.7

21.8

25

28.1

H2113B-3

23.5

27.3

31

34.8

H2114B-3

30

28.3

32.6

37

41.3

H2115B-3

36.6

42.3

48.1

53.8

H2116B-3

53.8

60.8

67.9

74.9

H2117B-3

30

30 30

30 30 30 30

Trip Curves, see Page 406. Notes  For motor full load amperes between listed values, adjust dial clockwise for higher or counterclockwise for lower motor currents. The currents listed are for 1.5 service factor motors. A position adjustment is provided for 1.0 service factor motors.  Set of three heater packs are required for both single- and three-phase applications.

404

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

Definite Purpose Contactors and Starters Starters

30.3

Standard Trip—Class 20 Heater Packs Manual or Automatic Reset Heater packs are shipped three to a carton. Catalog numbers listed below are for three heater packs.

30 30 30

Standard Trip Ratings Motor Full Load Ampere Rating  Dial Position A

B

C

D

Catalog Number  (Includes Three Heater Packs)

0.254

0.306

0.359

0.411

H2001B-3

0.375

0.452

0.53

0.607

H2002B-3

0.56

0.676

0.791

0.907

H2003B-3

0.814

0.983

1.15

1.32

H2004B-3

1.2

1.45

1.71

1.96

H2005B-3

1.79

2.16

2.53

2.9

H2006B-3

2.15

2.6

3.04

3.49

H2007B-3

3.23

3.9

4.56

5.23

H2008B-3

4.55

5.5

6.45

7.4

H2009B-3

6.75

8.17

9.58

11

H2010B-3

9.14

10.8

12.4

14

H2011B-3

14

16.9

19.9

22.8

H2012B-3

18.7

22.7

26.7

30.7

H2013B-3

23.5

28.5

33.5

38.5

H2014B-3

29

34

39.1

44.1

H2015B-3

39.6

45.5

51.5

57.4

H2016B-3

53.9

60.9

67.9

74.9

H2017B-3

30 30 30 30 30 30 30 30 30 30 30 30

Trip Curves, see Page 406.

30 Technical Data and Specifications

30

Terminal Wire Sizes

30

Line Side (Contactor)  Terminal Type

Wire Range—Solid or Stranded Power Terminals Coil Terminals

Screw/pressure plate

8–14 AWG

12–16 AWG

Box lug: 25–50A

4–14 AWG

12–16 AWG

Box lug: 60A

3–14 AWG

12–16 AWG

30 30 30

Power Terminals—Load—Cu Only (Stranded or Solid)

30

Terminal

Range

Torque Rating

25 and 30A

14–6 AWG

20 lb-in (14–10 AWG)

30

40, 50 and 60A

14–2 AWG

35 lb-in (14–10 AWG) 40 lb-in (8 AWG) 45 lb-in (6–4 AWG) 50 lb-in (3–2 AWG)

30 30

Control Terminals—Cu Only 12–16 AWG stranded, 12–14 AWG solid

30

Notes  For motor full load amperes between listed values, adjust dial clockwise for higher or counterclockwise for lower motor currents. The currents listed are for 1.5 service factor motors. A position adjustment is provided for 1.0 service factor motors.  Set of three heater packs are required for both single- and three-phase applications.  Line side (contactor) torque ratings can be found on Page 393.

30 30 30 30

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

405

30.3 30 30 30 30

Definite Purpose Contactors and Starters Starters

Overload Relay UL/CSA Contact Ratings Control Circuit AC Volts

120V

240V

480V

600V

NC Contact B600 Make and break

30A

15A

7.5A

6A

Break

3A

1.5A

0.75A

0.6A

Continuous

5A

5A

5A

5A

NO Contact C600

30

Make and break

15A

7.5A

3.375A

3A

Break

1.5A

0.75A

0.375A

0.3A

30

Continuous

2.5A

2.5A

2.5A

2.5A

30 30 30

Trip Curves Bimetallic Ambient Compensated Overload Relay—25°C Open Rating Class 10 Overload Relay

30 30 30

10,000

5000 4000 3000 2000

5000 4000 3000 2000

1000

1000

500 400 300 200

30 30

Class 20 Overload Relay

10,000

Trip Time (Seconds) 100

From Hot Start

50 40 30 20

30 30 30

500 400 300 200

From Cold Start

Trip Time (Seconds) 100

10

5 4 3 2 1

5 4 3 2 1

0

2 4 6 8 Multiples of Current Setting

From Hot Start

50 40 30 20

10

30

From Cold Start

0

10

2 4 6 8 Multiples of Current Setting

10

30 30 30

Wiring Diagrams Single-Phase Connections

L1

1NO Aux. Contact (When Supplied)

L2 13

30

98

30

97 96

30 30

L1

L2

1NO Aux. Contact (When Supplied)

L3

1

1

30

30

Wire “C” (Supplied with Common Control)

Wire “C” (Supplied with Common Control)

30 30

Three-Phase Connections

14

2/T1

4/T2

T1

T2

AC Motor

95

13 Wire “D” (Supplied with 1NO Aux. Contact)

14 98

Wire “D” (Supplied with 1NO Aux. Contact)

97 96 Reset

2/T1 4/T2 6/T3 T1

T2

95

T3

AC Motor

30 406

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

Definite Purpose Contactors and Starters Starters

30.3

Dimensions Approximate Dimensions in Inches (mm)

30

A25 and B25 Starers—Open Type

30 40, 50 and 60 Ampere

25 and 30 Ampere H

A

H

C

H

A

H

30 C

30 30 B

BE

30

E

30 G D Mtg. for #10-32 Screw

30

G D Mtg. for #10-32 Screw

30

Dimensions and Shipping Weights

Ampere Size

Wide A

High B

Deep C

Deep D

Mounting E

Mounting G

Auxiliary Contact Adder H

Shipping Weight Lbs (kg)

25 and 30

2.50 (64.0)

7.14 (181.0)

3.56 (90.4)

3.69 (93.7)

6.55 (166.0)

0.20 (5.1)

0.54 (13.7)

1.8 (0.8)

40

2.56 (65.0)

8.08 (205.0)

3.50 (89.0)

3.66 (93.0)

7.50 (190.5)

2.00 (51.0)

0.54 (13.7)

1.8 (0.8)

50 and 60

2.56 (65.0)

8.08 (205.0)

4.15 (105.0)

3.66 (93.0)

7.50 (190.5)

2.00 (51.0)

0.54 (13.7)

3.6 (1.6)

30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

407

30.3 30

Definite Purpose Contactors and Starters Starters

Contents

15–45A, Single- and Three-Phase—A27, B27

Description

30

Page

25–60A, Single- and Three-Phase—A25, B25 . . . . . . . . . . . 15–45A, Single- and Three-Phase—A27, B27 Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . . . . . Trip Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15–75A, Single- and Three-Phase—A30, B30 and C440/XT Electronic Overload Relay . . . . . . . . . . . . . . . . .

30 30 30 30 30

401 409 411 411 414 414 415 416

30 30 30 30

15–45A, Single- and Three-Phase—A27, B27

30

Product Description

Features and Benefits

A27 and B27 Definite Purpose Starters from Eaton’s electrical sector combine the features and flexibility of the C25 Definite Purpose Contactors and XT Series Bi-metallic Ambient Compensated Overload Relays.



30 30 30 30 30

● ●





30 ●

30

Selectable manual or automatic reset operation Class 10 trip class Bimetallic, ambient compensated operated. Trip free mechanism Electrically isolated NO-NC contacts (pull TEST button to test) Shrouded or fingerproof terminals to reduce possibility of electrical shock Single-phase sensitivity

Standards and Certifications ●



● ● ● ● ●

UL Recognized Components UL File #E-1491, Guide NLDX2 CSA Certified Components File #LR353, Guide 3 80W-1.14 Class 3211 04 IEC/EN 60947 VDE 0660 UL CSA CE

30 30 30 Catalog Number Selection

30

15–45A, Single- and Three-Phase—A27, B27

30

A27CNE30

A

040

30 Incomplete catalog number

30

Magnet coil suffix

Overload relay suffix

When Ordering Specify ● Catalog number plus magnet coil suffix plus overload relay suffix, see Page 410 Example, order catalog number A27CNE30A040

30 30 30 30 408

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

Definite Purpose Contactors and Starters Starters

30.3

Product Selection A27 Starter

30 Three-Phase Starter—Open Type

30

Ampere Rating Inductive Line Full Load Voltage

Locked Rotor

Maximum Motor (hp)

Maximum Motor (kW)

Common Control Metal Mounting Plate Catalog Number 

15

115

90





A27CNC15_

A27CRC15_

A27SNC15_

A27SRC15_

230

90

3

2.2

A27CNC15_

A27CRC15_

A27SNC15_

A27SRC15_

460

75

5

3.7

A27CNC15_

A27CRC15_

A27SNC15_

A27SRC15_

575

60

5

3.7

A27CNC15_

A27CRC15_

A27SNC15_

A27SRC15_

115

150





A27CNC25_

A27CRC25_

A27SNC25_

A27SRC25_

230

150

7-1/2

5.5

A27CNC25_

A27CRC25_

A27SNC25_

A27SRC25_

460

125

10

7.5

A27CNC25_

A27CRC25_

A27SNC25_

A27SRC25_

575

100

10

7.5

A27CNC25_

A27CRC25_

A27SNC25_

A27SRC25_

115

180





A27CNE30_

A27CRE30_

A27SNE30_

A27SRE30_

230

180

10

7.5

A27CNE30_

A27CRE30_

A27SNE30_

A27SRE30_

460

150

15

11

A27CNE30_

A27CRE30_

A27SNE30_

A27SRE30_

25

30

40

45

DIN Rail Adapter

Separate Control Metal Mounting Plate

DIN Rail Adapter

30

Catalog Number 

Catalog Number 

Catalog Number 

30

575

120

15

11

A27CNE30_

A27CRE30_

A27SNE30_

A27SRE30_

115

240





A27CNE40_

A27CRE40_

A27SNE40_

A27SRE40_

230

240

10

7.5

A27CNE40_

A27CRE40_

A27SNE40_

A27SRE40_

460

200

20

15

A27CNE40_

A27CRE40_

A27SNE40_

A27SRE40_

575

160

20

15

A27CNE40_

A27CRE40_

A27SNE40_

A27SRE40_

115

270





A27CNE45_

A27CRE45_

A27SNE45_

A27SRE45_

230

270

15

11

A27CNE45_

A27CRE45_

A27SNE45_

A27SRE45_

460

225

30

22

A27CNE45_

A27CRE45_

A27SNE45_

A27SRE45_

575

180

30

22

A27CNE45_

A27CRE45_

A27SNE45_

A27SRE45_

30 30 30 30 30 30 30 30 30 30 30 30

Note  Incomplete catalog number. Replace underscore (_) with magnet coil suffix and overload relay suffix from Page 410.

30 30 30 30 30 30 30 30 30 30 30 30 30 30

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

409

30.3

Definite Purpose Contactors and Starters Starters

Single-Phase Starter—Open Type, B27

30

Ampere Rating Inductive Line Full Load Voltage

Locked Rotor

Maximum Motor (hp)

Maximum Motor (kW)

Common Control Metal Mounting Plate Catalog Number 

15

115

90

3/4

0.4

B27CNC15_

B27CRC15_

B27SNC15_

B27SRC15_

230

90

2

1.5

B27CNC15_

B27CRC15_

B27SNC15_

B27SRC15_

460

75





B27CNC15_

B27CRC15_

B27SNC15_

B27SRC15_

575

60





B27CNC15_

B27CRC15_

B27SNC15_

B27SRC15_

115

150

2

1.5

B27CNC25_

B27CRC25_

B27SNC25_

B27SRC25_

230

150

3

2.2

B27CNC25_

B27CRC25_

B27SNC25_

B27SRC25_

460

125





B27CNC25_

B27CRC25_

B27SNC25_

B27SRC25_

575

100





B27CNC25_

B27CRC25_

B27SNC25_

B27SRC25_

115

180

2

1.5

B27CNE30_

B27CRE30_

B27SNE30_

B27SRE30_

30

230

180

5

3.7

B27CNE30_

B27CRE30_

B27SNE30_

B27SRE30_

460

150





B27CNE30_

B27CRE30_

B27SNE30_

B27SRE30_

30

575

120





B27CNE30_

B27CRE30_

B27SNE30_

B27SRE30_

115

240

3

2.2

B27CNE40_

B27CRE40_

B27SNE40_

B27SRE40_

230

240

7-1/2

5.5

B27CNE40_

B27CRE40_

B27SNE40_

B27SRE40_

460

200





B27CNE40_

B27CRE40_

B27SNE40_

B27SRE40_

575

160





B27CNE40_

B27CRE40_

B27SNE40_

B27SRE40_

115

270

3

2.2

B27CNE45_

B27CRE45_

B27SNE45_

B27SRE45_

230

270

7-1/2

7.5

B27CNE45_

B27CRE45_

B27SNE45_

B27SRE45_

460

225





B27CNE45_

B27CRE45_

B27SNE45_

B27SRE45_

575

180





B27CNE45_

B27CRE45_

B27SNE45_

B27SRE45_

30 30 30 30 30

25

30 30

30

40

30 30 30

45

30 30 30 30

Separate Control Metal Mounting Plate Catalog Number 

DIN Rail Adapter Catalog Number 

Overload Relay Suffix

Magnet Coil Suffix Voltage 60 Hertz

DIN Rail Adapter Catalog Number 

Voltage 60 Hertz

50 Hertz

Coil Suffix

12

R

12

1R

AC 

Coil Suffix

DC 

Suffix Code

For use with Contactor Ampere Range

0.1–0.16

P16

15–25A

Motor Full Load Amperes Frame C

30

12 24

24

T

24

1T

0.16–0.24

P24

15–25A

30

110–120

110–120

A

48

1W

0.24–0.4

P40

15–25A

208–240

208–240

B

120

1A

0.4–0.6

P60

15–25A

240 

220

J

0.6–1

001

15–25A

30

277



H

1–1.6

1P6

15–25A



380–415

L

1.6–2.4

2P4

15–25A

30

440–480

440–480

C

2.4–4

004

15–25A

550–600

550–600

D

4–6

006

15–25A

6–10

010

15–25A

10–16

016

15–25A

16–24

024

15–25A

24–32

032

15–25A

6–10

010

30–45A

10–16

016

30–45A

16–24

024

30–45A

24–40

040

30–45A

40–57

057

30–45A

30

30 30 30

Frame D

30 30 30 30

Notes  Incomplete catalog number. Replace underscore (_) with magnet coil suffix and overload relay suffix from tables above.  Class H AC coils available as option. Add 2 before AC coil suffix letter.  Available through 45A.  Starters with DC coils include an early breaking auxiliary contact, C320KGD1. See Page 440 for more detail.

30 410

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

Definite Purpose Contactors and Starters Starters

30.3

Renewal Parts

30

Overload Relays Motor Full Load Amperes

30

Suffix Code

For use with Contactor Ampere Range

Overload Relay Catalog Number

P16

15–25A

XTOBP16CC1DP

30

Frame C 0.1–0.16 0.16–0.24

P24

15–25A

XTOBP24CC1DP

0.24–0.4

P40

15–25A

XTOBP40CC1DP

0.4–0.6

P60

15–25A

XTOBP60CC1DP

0.6–1

001

15–25A

XTOB001CC1DP

1–1.6

1P6

15–25A

XTOB1P6CC1DP

1.6–2.4

2P4

15–25A

XTOB2P4CC1DP

30 30 30 30 30

2.4–4

004

15–25A

XTOB004CC1DP

4–6

006

15–25A

XTOB006CC1DP

6–10

010

15–25A

XTOB010CC1DP

10–16

016

15–25A

XTOB016CC1DP

16–24

024

15–25A

XTOB024CC1DP

24–32

032

15–25A

XTOB032CC1DP

30

010

30–45A

XTOB010DC1DP

30

30 30

Frame D 6–10 10–16

016

30–45A

XTOB016DC1DP

16–24

024

30–45A

XTOB024DC1DP

24–40

040

30–45A

XTOB040DC1DP

40–57

057

30–45A

XTOB057DC1DP

30 30 30 30

Technical Data and Specifications Terminal Wire Sizes

30

Power Terminals—Load—Cu Only (Stranded or Solid)

Line Side (Contactor)  Terminal Type

Wire Range—Solid or Stranded Power Terminals Coil Terminals

Terminal

Range

Torque Rating

15 and 25A

14–8 AWG

16 lb-in (14–8 AWG)

Screw/pressure plate

8–14 AWG

12–16 AWG

30, 40 and 45A

14–2 AWG

31 lb-in (14–2 AWG)

Box lug: 15–45A

4–14 AWG

12–16 AWG

Control Terminals—Cu Only

30 30 30

12–16 AWG stranded, 12–14 AWG solid

30

Note  Line side (contactor) torque ratings can be found on Page 393.

30 30 30 30 30 30 30 30 30 Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

411

30.3 30 30

Definite Purpose Contactors and Starters Starters

Overload Relays These tripping characteristics are the mean values of the spread at 20°C ambient temperature in a cold state.

30

Tripping time depends on response current. With devices at operating temperature, the tripping time of the overload relay reduces to approximately 25% of the read off value. Specific characteristics for each individual setting range can be found in MN03402001E.

30

Overload Relays

30

Description

30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

XTOB … CC1 Specification

XTOB … DC1 Specification

Climatic proofing

Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60 068-2-30

Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60 068-2-30

Ambient temperature range 

–25° to 50°C [–13° to 122°F]

–25° to 50°C [–13° to 122°F]

Temperature compensation

Continuous

Continuous

Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 ms

10g

10g

Degree of protection

IP20

IP20

Protection against direct contact when actuated from front (IEC 536)

Finger and back of hand proof

Finger and back of hand proof 690

General

Insulation voltage (Ui) Vac

690

Overvoltage category/pollution degree

III/3

III/3

Impulse withstand voltage (Uimp) Vac

6000

6000

Operational voltage (Ue) Vac

690

690

Safe isolation to VDE 0106 Part 101 and Part 101/A1 Between auxiliary contacts and main contacts (Vac)

440

440

440

440

Overload relay setting range

0.1–32A

6–75A

Temperature compensation residual error >20°C (%/K)

≤0.25

≤0.25

Current heat loss (3 conductors) Lower value of setting range, W

2.5

3

Between main contacts (Vac)

Upper value of setting range, W Terminal capacity

6

7.5

2 x (1–6)

2 x (1–6)

2 x (1–4)

Solid, mm 2 Flexible with ferrule, mm 2

2 x (1–6)

1 x 25 

2 x (1–10) 

Solid or stranded, AWG

14-8

14-2

Terminal screw

M4

M6

1.8 (16)

3.5 (31)

Tools Pozidrive screwdriver

Size 2

Size 2

Standard screwdriver

1x6

1x6

Tightening torque Nm (lb-in)

Notes  Ambient temperature operating range to IEC/EN 60947, PTB: –5° to 50°C [23° to 122°F].  6 mm2 flexible with ferrules to DIN 46228.  Main contact terminal capacity, solid and stranded conductors with ferrules: When using two conductors use identical cross-section.

30 30 30 30 30 30 412

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

Definite Purpose Contactors and Starters Starters

30.3

Overload Relays, continued XTOB … CC1 Specification

XTOB … DC1 Specification

Impulse withstand voltage (Uimp) Vac

6000

6000

Overvoltage category/pollution degree

III/3

III/3

Terminal capacity Solid, mm 2

2 x (0.75–4)

2 x (0.75–4)

Flexible with ferrule, mm 2

2 x (0.75–2.5)

2 x (0.75–2.5)

Solid or stranded, AWG

2 x (18–12)

2 x (18–12)

M3.5

M3.5

Description

30 30

Auxiliary and Control Circuit Connections

Terminal screw Tightening torque Nm (lb-in)

30 30 30 30

0.8–1.3 (7–11.5)

0.8–1.3 (7–11.5)

Tools Pozidrive screwdriver

30

Size 2

Size 2

30

Standard screwdriver

1x6

1x6

Auxiliary circuit rated insulation voltage (Ui) Vac

500

500

Rated operational voltage (Ue) Vac

500

500

Safe isolation to VDE 0106 Part 101 and Part 101/A1 Between the auxiliary contacts (Vac)

240

240

Conventional thermal current, Ith

6

6

30 30 30

Rated operational current—AC-15

30

NO contact

30

120V

1.5

1.5

240V

1.5

1.5

415V

0.5

0.5

500V

0.5

0.5

30

120V

1.5

1.5

30

240V

1.5

1.5

415V

0.9

0.9

500V

0.8

0.8

24V

0.9

0.9

60V

0.75

0.75

110V

0.4

0.4

0.2

0.2

6

6

30

NC contact

30 30

Rated operational current—DC-13 L/R ≤15 ms  NO contact

220V Short circuit rating without welding maximum fuse, A gG/gL

30 30 30 30

Note  Rated operational current: Making and breaking conditions to DC-13, L/R constant as stated.

30 30 30 30 30 30 30 30

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

413

30.3 30

Overload Relay 2h 100 60 40

30

10 6 4 2

30

1 40

30

3-Phase

20 Seconds

30

XTOB...CC1, XTOB...DC1

20

Minutes

30

10 6 4

30

2-Phase

2 1 0.6

30

1

1.5 2

30

Single-Phase Connections

L1

Wire “C” (Supplied with Common Control)

1NO Aux. Contact (When Supplied)

L2

L1

L2

1NO Aux. Contact (When Supplied)

L3

1

1

13

13 14

30

98

30 30

Three-Phase Connections

Wire “C” (Supplied with Common Control)

30

30

6 8 10 15 20

Wiring Diagrams

30 30

3 4

x Setting Current

30 30

Starters

Trip Curve

30 30

Definite Purpose Contactors and Starters

Wire “D” (Supplied with 1NO Aux. Contact)

14 98 97 96

97 96 2/T1

4/T2

T1

T2

95

Wire “D” (Supplied with 1NO Aux. Contact)

Reset

2/T1 4/T2 6/T3 T1

T2

95

T3

30 30

AC Motor

AC Motor

30 30 30 30 30 30 30 30 414

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

Definite Purpose Contactors and Starters Starters

30.3

Dimensions Approximate Dimensions in Inches (mm)

30

A27 and B27 Starters—Open Type

30 30, 40 and 45 Ampere

15 and 25 Ampere A

H

A

C

30 C

H

30 30

E

E B

30

B

30 D

30

D

30

Dimensions and Shipping Weights

Ampere Size

Wide A

High B

Deep C

Deep D

Mounting E

Mounting G

Auxiliary Contact Adder H

Shipping Weight Lbs (kg)

15 and 25 (metal plate)

2.40 (61.0)

5.50 (139.0)

3.35 (85.0)

3.70 (94.0)

3.13 (82.6)



0.54 (13.7)

1.6 (0.7)

15 and 25 (DIN rail mount)

2.23 (56.5)

5.20 (133.0)

3.35 (85.0)

3.70 (94.0)





0.54 (13.7)

1.6 (0.7)

30, 40 and 45 (metal plate)

2.40 (61.0)

6.00 (152.0)

3.35 (85.0)

3.90 (98.0)

3.13 (82.6)



0.54 (13.7)

1.11 (0.9)

30, 40 and 45 (DIN rail mount)

2.23 (56.5)

5.70 (145.0)

3.35 (85.0)

3.90 (98.0)





0.54 (13.7)

1.11 (0.9)

30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

415

30.3 30

Definite Purpose Contactors and Starters Starters

15–75A, Single- and Three-Phase—A30, B30 and C440/XT Electronic Overload Relay

30

Contents Description

Page

25–60A, Single- and Three-Phase—A25, B25 . . . . . . . . . . . 15–45A, Single- and Three-Phase—A27, B27 . . . . . . . . . . . 15–75A, Single- and Three-Phase—A29, B30 and C440/XT Electronic Overload Relay Standards and Certifications . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

30 30 30 30 30

401 408

417 417 418 420 421 423

30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30

15–75A, Single- and Three-Phase—A30, B30 and C440/XT Electronic Overload Relay Product Description

Features

A30 and B30 Starters A30 and B30 Definite Purpose Starters from Eaton’s electrical sector combine the features and flexibility of the C25 Definite Purpose Contactors and C440 Electronic Overload Relays.

A30 and B30 Starters ● Standard version: selectable trip class (10A, 10, 20, 30) with selectable manual or auto reset ● Current adjustment range: 5:1 ● Self-powered design—will accept AC voltages from 12 to 690V 50/60 Hz ● Ambient temperature compensation ● Low heat generation ● Phase loss protection ● Phase unbalance protection ● Electrically isolated 1NO-1NC contacts (push-to-test) ● Trip status indicator

C440 Overload C440 is the most compact, high-featured, economical product in its class. C440 is a self-powered electronic overload relay available up to 100A as a self contained unit. With external CTs, C440 can protect motor up to 1500 FLA. Available add-on accessories include remote reset capability and communication modules with I/O for DeviceNet, PROFIBUS, and Modbus.

C440 Overload ● Reliable, accurate, electronic motor protection ● Easy to select, install and maintain ● Compact size ● Flexible, intelligent design ● Global product offering— available with NEMA, IEC and DP power control Motor Control ● Two B600 alarm (NO) and fault (NC) contacts ● Test/Trip button Motor Protection ● Thermal overload ● Phase loss ● Selectable (ON/OFF) phase unbalance ● Selectable (ON/OFF) ground fault

User Interface ● Large FLA selection dial ● Trip status indicator ● Operating mode LED ● DIP switch selectable trip class, phase unbalance and ground fault ● Selectable Auto/Manual reset Feature Options ● Remote reset ● 120 Vac ● 24 Vac ● 24 Vdc ●

Tamper-proof cover

30 30 30 30 30 30 416

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

Definite Purpose Contactors and Starters Starters

30.3

Standards and Certifications

30

A30 and B30 Starters ● UL Listed Components ● CSA Certified Components ● IEC EN 60947-4-1, EN 60947-5-1 ● CE Certified Components ● CCC Certified Components ● RoHS Certified Components

30 30 30 30 30 30

Catalog Number Selection

30

A29 and B29 Definite Purpose Starters

30 30

A 30 C N C 25 A X 5E 005

30 Designation A = Three-phase starter B = Single-phase starter

Overload Range DP Starters with C440 Electronic Overload 15A–75A Contactor 005 = 1–5A 045 = 9–45A 020 = 4–20A 100 = 20–100A

30 30

Type 29 = Non-reversing

30 30

OLR Model Designation 5C = C440 with ground fault 5E = Standard C440 OLR SEL Reset, SEL Class

Control C = Common control S = Separate control

30 30

Auxiliary Contacts (Side Mount) A = 1NO pressure plate B = 1NC pressure plate C = 1NO-1NC pressure plate D = 2NO pressure plate E = 2NC pressure plate F = 1NO pressure plate and QC G = 1NC pressure plate and QC H = 1NO-1NC pressure plate and QC J = 2NO pressure plate and QC K = 2NC pressure plate and QC L = 1NO-1NC snap switch QC only M = 2NO-2NC snap switch QC only X = None

Enclosure Type N = Open with metal mounting plate R = Open with DIN rail mounting adapter (two- and three-pole, 15–50A contactors only) G = NEMA Type 1 enclosed

Power Terminals 15–40A Contactor A = Binding head screws without quick connect terminals B = Binding head screws with quick connect terminals C = Pressure plate without quick connect terminals D = Pressure plate with quick connect terminals E = Lugs without quick connect terminals F = Lugs with quick connect terminals 50–75A Contactor E = Lugs without quick connect terminals F = Lugs with quick connect terminals

T= A= B= C=

24V 110/120V 208/240V 440/480V

30 30 30 30 30 30

AC Coil Codes D = 550/600V H = 277V L = 380/415V J = 240V/60 Hz; 220V/50 Hz (Available through 50A)

30 30

Current Ratings 25 = 25A 50 = 50A 30 = 30A 60 = 60A 40 = 40A 75 = 75A

30 30 30 30 30

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

417

30.3 30 30 30

Definite Purpose Contactors and Starters Starters

Product Selection When Ordering Specify ● Catalog number plus AC coil code, auxiliary contact code, OLR model designation and overload range code, see below A30 Starter

Three-Phase Starters—Open Type A30 with C440 Electronic Overload

30

Ampere Rating

30

Inductive Full Load

Line Voltage

Locked Rotor

Maximum Motor (hp)

30

25

115

150

230

150

460 575

Maximum Motor (kW)

Common Control Metal Mounting Plate Catalog Number 





7-1/2

5-1/2

125

10

7-1/2

100

10

7-1/2

115

180





230

180

10

7-1/2

460

150

15

11

575

120

15

11

115

240





30

230

240

10

7-1/2

460

200

20

15

30

575

160

20

15

115

300





230

300

15

11

460

250

30

22

575

200

30

22

115

360





230

360

20

15

460

300

40

30

575

340

40

30

115

450





230

450

20

18-1/2

460

375

50

37

575

300

50

37

30 30

30

30 30

40

45

30 30 60

30 30 30

75

30 30

DIN Rail Adapter Catalog Number 

Separate Control Metal Mounting Plate Catalog Number 

DIN Rail Adapter Catalog Number 

A30CNC25_

A30CRC25_

A30SNC25_

A30SRC25_

A30CNE30_

A30CRE30_

A30SNE30_

A30SRE30_

A30CNE40_

A30CRE40_

A30SNE40_

A30SRE40_

A30CNE45_

A30CRE45_

A30SNE45_

A30SRE45_

A30CNE60_



A30SNE60_



A30CNE75_



A30SNE75_



Note  Incomplete catalog number. Replace underscore (_) with suffix, see Page 419.

30 30 30 30 30 30 30 30 30 30 30 418

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

Definite Purpose Contactors and Starters Starters

30.3

When Ordering Specify ● Catalog number plus AC coil code, auxiliary contact code, OLR model designation and overload range code, see below

30 30

Single-Phase Starters—Open Type, B30 with C440 Electronic Overload Ampere Rating Inductive Full Load

Line Voltage

Locked Rotor

Maximum Motor (hp)

Maximum Motor (kW)

Common Control Metal Mounting Plate Catalog Number 

25

115

150

2

1.5

B30CNC25_

230

150

3

2.2

460

125





30

40

45

C440/XT Electronic Overload Relay

575

100





115

180

2

1.5

230

180

5

3.7

460

150





575

120





115

240

3

2.2

230

240

7-1/2

5.5

460

200





575

160





115

300

3

2.2

230

300

10

7.5

460

250





575

200





30

DIN Rail Adapter Catalog Number 

Separate Control Metal Mounting Plate Catalog Number 

DIN Rail Adapter Catalog Number 

B30CRC25_

B30SNC25_

B30SRC25_

DP Contactor Rating

Suffix Code

30 30 30

B30CNE30_

B30CRE30_

B30SNE30_

B30SRE30_

30 30 B30CNE40_

B30CRE40_

B30SNE40_

B30SRE40_

30 30

B30CNE45_

B30CRE45_

B30SNE45_

30

B30SRE45_

30 30 30

C440 Electronic Overload Relay for Integrated Use with DP Contactors C440 Overload Relay for Integrated Use with DP Contactors by Feature Set FLA Range (Amps)

30

Overload Relay Catalog Number (Standard)

30

Overload Relay Catalog Number (Ground Fault)

30

Frame D 1–5

25–50A

005

C440A1A005SDD

C440A2A005SDD

4–20

25–50A

020

C440A1A020SDD

C440A2A020SDD

9–45

25–50A

045

C440A1A045SDD

C440A2A045SDD

60–75A

100

C440B1A100SDF

C440B2A100SDF

30 30 30

Frame F 20–100

30 Note  Incomplete catalog number. Replace underscore (_) with suffix, see table above.

30 30 30 30 30 30 30 30 30

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

419

30.3 30

Starters

Accessories CT Kits

30 30

Definite Purpose Contactors and Starters

Accessories Description Safety Cover

Safety Cover Clear Lexan cover that mounts on top of the FLA dial and DIP switches when closed.

30

Catalog Number

ZEB-XSC

30 30 30

Reset Bar

Reset Bar Assembles to the top of the overload to provide a larger target area for door mounted reset operators.

30

ZEB-XRB

30 30 30

Remote Reset

30

Remote Reset Remote reset module (24 Vdc) 

C440-XCOM

Remote reset module (120 Vac) 

ZEB-XRR-120

Remote reset module (24 Vac) 

ZEB-XRR-24

30 30

Note  Customer can wire remote mounted button to reset module (i.e., 22 mm pushbutton, catalog number M22-D-B-GB14-K10).

30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 420

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

Definite Purpose Contactors and Starters Starters

30.3

Technical Data and Specifications

30

Electronic Overload Relays up to 1500A

30

Description

Specification 45 mm

55 mm

Electrical Ratings

Range

Range

Operating voltage (three-phase) and frequency

690 Vac (60/50 Hz)

690 Vac (60/50 Hz)

30 30

FLA Range

30

0.33–1.65A 1–5A 4–20A 9–45A

20–100A

30

XT IEC frames

B, C, D

F, G

30

Freedom NEMA sizes

00, 0, 1, 2

3

DP contactors

25–50A

60, 75A

10A, 10, 20, 30 Selectable

10A, 10, 20, 30 Selectable

Thermal overload setting

1.05 x FLA: does not trip 1.15 x FLA: overload trip

1.05 x FLA: does not trip 1.15 x FLA: overload trip

30

Feature

Range

Range

Phase loss

Fixed threshold 50%

Fixed threshold 50%

30

Phase unbalance (selectable: enable/disable)

Fixed threshold 50%

Fixed threshold 50%

30

Ground fault (selectable: enable/disable)

50% of FLA dial setting >150% = 2 sec >250% = 1 sec

50% of FLA dial setting >150% = 2 sec >250% = 1 sec

30

Reset

Manual/automatic

Manual/automatic

30 30

Use with Contactors

30

Trip Class

30 30

Motor Protection

Indicators Trip status

Orange flag

Orange flag

Mode LED

One flash: Overload operating properly Two flashes: Current is above FLA dial setting—pending trip

One flash: Overload operating properly Two flashes: Current is above FLA dial setting—pending trip

Remote reset

Yes

Yes

Reset bar

Yes

Yes

Communication expansion module

Yes

Yes

Communication adapter

Yes

Yes

Terminal capacity

12–10 AWG (4–6 mm2) 8–6 AWG (6–16 mm2)

6–1 AWG (16–50 mm2)

Tightening torque

20–25 lb-in (2.3–2.8 Nm) 25–30 lb-in (2.8–3.4 Nm)

25–30 lb-in (2.8–3.4 Nm)

Terminal capacity

2 x (18–12) AWG

2 x (18–12) AWG

Tightening torque

5.3 lb-in (0.8–1.2 Nm)

5.3 lb-in (0.8–1.2 Nm)

30

Options

30 30 30

Capacity

30

Load terminals

30 30

Input, auxiliary contact and remote reset terminals

30 30

Voltages Insulation voltage U i (three-phase)

690 Vac

690 Vac

Insulation voltage U i (control)

500 Vac

500 Vac

Rated impulse withstand voltage

6000 Vac

6000 Vac

Overvoltage category/pollution degree

III/3

III/3

30 30 30 30 30

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

421

30.3 30

Definite Purpose Contactors and Starters Starters

Electronic Overload Relays up to 1500A, continued

30

Description

30

Conventional thermal continuous current

30

Specification 45 mm

55 mm

5A

5A

Auxiliary and Control Circuit Ratings

Rated operational current—IEC AC-15 Make contact (1800 VA)

30

120V

15A

15A

240V

15A

15A

30

415V

0.5A

0.5A

500V

0.5A

0.5A

120V

1.5A

1.5A

240V

1.5A

1.5A

415V

0.9A

0.9A

500V

0.8A

0.8A

1.0A

1.0A

120V

30A

30A

30

240V

15A

15A

480V

7.5A

7.5A

30

600V

6A

6A

120V

3A

3A

30

240V

1.5A

1.5A

480V

0.75A

0.75A

30

600V

0.6A

0.6A

0–120V

0.22A

0.22A

250V

0.11A

0.11A

6A gG/gL

6A gG/gL

30

Break contact (180 VA)

30 30 30

IEC DC-13 (L/R F 15 ms1) 0–250V

30 30

30

Rated operational current—UL B600 Make contact (3600 VA)

Break contact (360 VA)

R300—Vdc ratings (28 VA)

30 30

Short-Circuit Rating without Welding

30

Maximum fuse

30

Ambient temperature (operating)

–13° o 149°F (–25° to 65°C)

–13° to 149°F (–25° to 65°C)

Ambient temperature (storage)

–40° to 185°F (–40° to 85°C)

–40° to 185°F (–40° to 85°C)

Operating humidity UL 991 (H3)

5% to 95% non-condensing

5% to 95% non-condensing

Altitude (no derating) NEMA ICS1

2000m

2000m

Shock (IEC 600068-2-27)

15g any direction

15g any direction

30

Vibration (IEC 60068-2-6)

3g any direction

3g any direction

Pollution degree per IEC 60947-4-1

3 for product (2 for pcb)

3 for product (2 for pcb)

30

Ingress protection

IP20

IP20

30 30

30 30

Environmental Ratings

Protection against direct contact when actuated from front (IEC 536)

Finger- and back-of-hand proof

Finger- and back-of-hand proof

Mounting position

Any

Any

Climatic proofing

Damp heat, constant to IEC 60068-2-30

Damp heat, constant to IEC 60068-2-30

30 30 30 422

Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

Definite Purpose Contactors and Starters Starters

30.3

Electronic Overload Relays up to 1500A, continued

30

Specification 45 mm

55 mm

30

Radiated emissions IEC 60947-4-1-Table 15 EN 55011 (CISPIR 11) Group 1, Class A, ISM

30 MHz to 1000 MHz

30 MHz to 1000 MHz

30

Conducted emissions IEC 60947-4-1-Table 14 EN 55011 (CISPIR 11) Group 1; Class ISM

0.15 MHz to 30 MHz

0.15 MHz to 30 MHz

ESD immunity IEC 60947-4-1 (Table 13)

±8 kV air, ±6 kV contact

±8 kV air, ±6 kV contact

Radiated immunity IEC 60947-4-1 IEC 61000-4-3

10V/m 80 MHz–1000 MHz 3V/m from 1.4 to 2.7 GHz 80% amplitude modulated 1 kHz sine wave

10V/m 80 MHz–1000 MHz 3V/m from 1.4 to 2.7 GHz 80% amplitude modulated 1 kHz sine wave

Conducted immunity IEC 60947-4-1, IEC 61000-4-6

140 dub (10V rms) 150 kHz–100 MHz

140 dub (10V rms) 150 kHz–100 MHz

Fast transient immunity IEC 60947-4-1 (Table 13) IEC 61000-4-4

±4 kV using direct method with accessory installed in expansion bay ±2 kV using direct method

±4 kV using direct method with accessory installed in expansion bay ±2 kV using direct method

Surge immunity IEC 60947-4-1 (Table 13) IEC 61000-4-5 a Class 4

Three-phase power inputs: ±4 kV line-to-line (DM) ±4 kV line-to-ground (CM)

Three-phase power inputs: ±4 kV line-to-line (DM) ±4 kV line-to-ground (CM)

With accessory installed in expansion bay: ±2 kV line-to-line (DM) –>1.2/50 us; 2 kV line-to-earth, 1 kV line-to-line ±4 kV line-to-ground (CM)

With accessory installed in expansion bay: ±2 kV line-to-line (DM) –>1.2/50 us; 2 kV line-to-earth, 1 kV line-to-line ±4 kV line-to-ground (CM)

Power freq. magnetic field immunity IEC 60947-4-1, IEC 61000-4-8

30A/m, 50 Hz

30A/m, 50 Hz

Electromagnetic field IEC 60947-4-1 Table 13, IEC 61000-4-3

10 V/m

10 V/m

Distortion IEEE 519

5% THD max., 5th harmonic 3% max.

5% THD max., 5th harmonic 3% max.

Electrostatic discharge (ESD) IEC 61000-4-2, EN 61131-2

4 kV contact 8 kV air discharge

4 kV contact 8 kV air discharge

30

Electrical fast transient (EFT) IEC 61000-4-4, EN 61131-2

±2 kV using direct method

±2 kV using direct method

30

Surge immunity IEC 61000-4-5, EN 61131-2

±2 kV line-to-ground (CM)

±2 kV line-to-ground (CM)

30

Description Electrical/EMC

30 30 30 30 30 30 30 30 30 30 30 30

30 Wiring Diagrams

30

Single-Phase Connections

Three-Phase Connections

L1

1NO Aux. Contact (When Supplied)

L2

30

Wire “C” (Supplied with Common Control)

Wire “C” (Supplied with Common Control)

L1

L2

30

1NO Aux. Contact (When Supplied)

L3

30

1

1

13

13 14 98

2/T1

4/T2

T1

T2

AC Motor

Wire “D” (Supplied with 1NO Aux. Contact)

14 98

97 96

97 96

95

95

Reset

2/T1 4/T2 6/T3 T1

T2

30

Wire “D” (Supplied with 1NO Aux. Contact)

30 30 30

T3

30 30

AC Motor

30 Volume 5—Motor Control and Protection CA08100006E—April 2011 www.eaton.com

For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616

423

Index

A above, 2, 10, 19, 21 AC, 2, 6, 10, 13-14, 16-19, 22-23 accept, 16 access, 4 accessibility, 4 Accessories, 1, 4, 16, 20 accessories, 16 AccessoriesContactor, 4 accessory, 23 accidental, 4 accordance, 3 accurate, 16 actuated, 12, 22 Adapter, 9-10, 18-19 adapter, 17, 21 AdapterFull, 18 Add, 2, 10 add, 16 Adder, 7, 15 adjust, 4-5 adjustable, 1 Adjustment, 3 adjustment, 3-5, 16 against, 3, 12, 22 air, 23 alarm, 16 Altitude, 22 Ambient, 1, 6, 8, 12, 16, 22 ambient, 1, 8, 12 Ampere, 4-5, 7, 9-11, 15, 18-19

ampere, 3 Amperes, 3, 10-11 amperes, 3-5 amplitude, 23 Amps, 19 An, 3 an, 2-3, 10 and, 1-23 ANO, 6 Any, 22 any, 22 apparatus, 3 appear, 3 Application, 4 applications, 2, 4-5 Approximate, 7, 15 approximately, 12 April, 1-23 are, 3-5, 12 area, 20 Art, 3 as, 2-3, 10, 13, 16 Assembles, 20 at, 1-23 Auto, 16 auto, 4, 16 Automatic, 3-5 automatic, 1, 3, 8, 21 Aux, 6, 14, 23 Auxiliary, 7, 13, 15, 17, 22 auxiliary, 2, 10, 12-13, 18-19, 21 Available, 2, 10, 16-17 available, 2, 10, 16 AWG, 5, 11-13, 21

Index

B back, 12, 22 Bar, 20 bar, 21 bay, 23 be, 5, 11-12 before, 2, 10 below, 4-5, 18-19 Benefits, 1, 8 Between, 12-13 between, 3-5 Bi, 1, 8 Bimetallic, 1, 6, 8 Binding, 17 blue, 3 both, 4-5 Box, 5, 11 branch, 3 Break, 6, 22 break, 6 breaking, 2, 10, 13 button, 1, 3, 8, 16, 20 by, 19

C CA, 1-23 calibrated, 1 call, 1-23 can, 5, 11-12, 16, 20 capability, 16 Capacity, 21 capacity, 12-13, 21 carton, 4-5 Catalog, 1-2, 4-5, 8-11, 16-20 catalog, 1-2, 8-10, 18-20 category, 12-13, 21 CC, 11-14 CCC, 17 CCW, 3 CE, 8, 17 Certifications, 1, 8, 16-17 Certified, 1, 8, 17 changes, 4 Characteristics, 3

characteristics, 3, 12 Circuit, 6, 13, 22 circuit, 3, 13 circuits, 3 CISPIR, 23 Class, 1-6, 8, 10, 17, 21, 23 class, 8, 16 Clear, 4, 20 Climatic, 12, 22 clockwise, 4-5 closed, 20 CM, 23 CNC, 1-2, 9-10, 18-19 CNE, 2, 8-10, 18-19 Code, 10-11, 19 code, 18-19 Codes, 17 Coil, 2, 5, 10-11, 17 coil, 1-2, 8-10, 18-19 coils, 2, 10 Cold, 6 cold, 12 com, 1-23 combine, 1, 8, 16 Common, 2, 6, 9-10, 14, 17-19, 23 common, 1 Communication, 21 Compact, 16 compact, 16 Compensated, 1, 6, 8 compensated, 1, 8 compensation, 12, 16 Components, 1, 8, 17 condensing, 22 conditions, 13 Conducted, 23 conductors, 3, 12 connect, 17 Connections, 6, 13-14, 23 Connectors, 3 constant, 12-13, 22 Contact, 6-7, 14-15, 23 contact, 2, 10, 12-13, 18-19, 21-23 ContactL, 14 Contactor, 5, 10-11, 17, 19 contactor, 2, 5, 11 Contactors, 1-23 contactors, 17, 21 Contacts, 17 contacts, 1, 8, 12-13, 16 contained, 16 Contents, 1, 8 ContentsC, 16

Index

continued, 13, 23 continuedSpecification, 22 Continuous, 6, 12 continuous, 22 Control, 1-23 control, 3, 16-17, 21 Conventional, 13, 22 correspond, 3 counter, 4-5 counterclockwise, 3 Cover, 4, 20 cover, 4, 16, 20 covering, 4 CRC, 9-10, 18-19 CRE, 9-10, 18-19 cross, 12 CSA, 1, 6, 8, 17 CSAterminals, 8 CT, 20 CTs, 16 Cu, 5, 11 Current, 3, 6, 12, 14, 16-17, 21 current, 3, 12-13, 22 currents, 4-5 Curve, 8, 14 Curves, 1, 4-6 Customer, 20 cyclic, 12

designation, 18-19 designrange, 16 detail, 2, 10 device, 3 DeviceNet, 16 devices, 3, 12 Diagrams, 1, 6, 8, 14, 16, 23 Dial, 3-5 dial, 3-5, 16, 20-21 Dimensions, 1, 7-8, 15 DIN, 9-10, 12, 15, 17-19 DIP, 16, 20 direct, 12, 22-23 direction, 22 disable, 21 discharge, 23 Distortion, 23 DM, 23 do, 2 does, 3, 21 door, 20 DP, 11, 16-17, 19, 21 dub, 23 due, 3

E D Damp, 12, 22 Data, 1, 5, 8, 11, 16, 21 DC, 2, 10-14, 22 Deep, 7, 15 defined, 3 defines, 3 Definite, 1-23 definition, 3 Degree, 12 degree, 12-13, 21-22 Delivery, 1-23 depending, 3 depends, 12 derating, 22 Description, 1, 8, 12-13, 16, 20-23 design, 16 Designation, 17

each, 12 early, 2, 10 earth, 23 Easy, 16 Eaton, 1, 8, 16 eaton, 1-23 economical, 16 EFT, 23 eight, 7, 15 eights, 7, 15 Electrical, 21, 23 electrical, 1, 8, 16 Electrically, 1, 8, 16 Electromagnetic, 23 Electronic, 1, 8, 16-19, 21-23 electronic, 16 Electrostatic, 23 EMC, 23 emissions, 23 EN, 8, 12, 17, 23 enable, 21

Index

enclosed, 17 Enclosure, 17 Enclosures, 4 Environmental, 22 erminal, 5 error, 12 es, 21 ESD, 23 Estimate, 3 Example, 1, 3, 8 example, 3 excessive, 3 expansion, 21, 23 expression, 3 external, 16

F Factor, 3 factor, 1, 3-5 factory, 3 failure, 3 falls, 3 Fast, 4, 23 fast, 23 Fault, 19 fault, 16-17, 21 faults, 3 Feature, 16, 19, 21 featured, 16 Features, 1, 8, 16 features, 1, 8, 16 ferrule, 12-13 ferrules, 12 field, 23 File, 1, 8 Finger, 12, 22 fingerproof, 1, 8 fire, 3 Fixed, 21 FLA, 1, 3-4, 16, 19-21 flag, 3, 21 flash, 21 flashes, 21 flexibility, 1, 8, 16 Flexible, 12-13, 16 flexible, 12 For, 1-23

for, 1-5, 7, 10, 12, 16, 19-20, 22 found, 5, 11-12 Frame, 10-11, 19 frames, 21 free, 1, 8 Freedom, 1, 21 freq, 23 frequency, 21 From, 6 from, 1-2, 8-10, 12, 16, 22-23 front, 12, 22 Full, 2-5, 9-11, 19 full, 4-5 fuse, 13, 22

G GB, 20 General, 3, 12 generation, 16 gG, 13, 22 GHz, 23 gL, 13, 22 Global, 16 Gray, 4 Ground, 19, 21 ground, 3, 16-17, 23 Group, 23 Guide, 1, 8

H Half, 12 half, 3 hand, 12, 22 harmonic, 23 has, 3 having, 3 head, 17 heat, 12, 16, 22 Heater, 1, 4-5 heater, 1-5 heating, 3 helps, 4

Index

Hertz, 2, 10 High, 7, 15 higher, 4-5 Hot, 6 hp, 2, 9-10, 18-19 humidity, 22 Hz, 2, 16-17, 21, 23

isolated, 1, 8, 16 isolation, 12-13 its, 3, 16

K I ICS, 22 identical, 12 IEC, 8, 12, 16-17, 21-23 IEEE, 23 III, 12-13, 21 illustration, 3 Immediate, 1-23 immunity, 23 Impulse, 12-13 impulse, 21 in, 3, 5, 7, 11-13, 15-16, 21, 23 Inches, 7, 15 include, 2-3, 10, 16 Includes, 4-5 Incomplete, 1-2, 8-10, 18-19 indicating, 3 Indication, 3 indication, 1, 3 indicatorcommunication, 16 Indicators, 21 indicatorselectable, 16 individual, 12 Inductive, 2, 9-10, 18-19 Ingress, 22 Input, 21 inputs, 23 install, 16 installed, 23 Insulation, 12, 21 insulation, 13 Integrated, 19 intelligent, 16 intended, 3 Interchangeable, 1 Interface, 16 IP, 12, 22 is, 3-5, 16, 21 ISM, 23

kg, 7, 15 KGD, 2, 10 kHz, 23 Kits, 20 KMParts, 1-23 kV, 23 kW, 2, 9-10, 18-19

L Laboratory, 3 Large, 16 larger, 20 lb, 5, 11-13, 21 Lbs, 7, 15 LED, 16, 21 less, 3 letter, 2-3, 10 Lexan, 20 Line, 2, 5, 9-11, 18-19 line, 23 Listed, 17 listed, 4-5 Load, 2-5, 9-11, 18-19, 21 load, 4-5 Locked, 2, 9-10, 18-19 Locking, 4 loss, 12, 16, 21 Low, 16 Lower, 12 lower, 4-5 LR, 1, 8 lug, 5, 11 Lugs, 17

Index

M Magnet, 1-2, 8, 10 magnet, 1-2, 8-10 magnetic, 23 Main, 12 main, 12 maintain, 16 Make, 6, 22 Making, 13 Manual, 3-5, 16, 21 manual, 1, 3-4, 8, 16 match, 1 max, 23 Maximum, 2, 9-10, 18-19, 22 maximum, 13 mean, 12 Mechanical, 12 mechanism, 1, 8 Metal, 9-10, 18-19 metal, 15, 17 metallic, 1, 8 method, 23 MHz, 23 Minimum, 4 minimum, 3 Minutes, 14 minutes, 3 mm, 7, 12-13, 15, 20-23 MN, 12 Modbus, 16 Mode, 21 mode, 16 Model, 17 model, 18-19 modulated, 23 module, 20-21 modules, 16 more, 2-3, 10 most, 16 Motor, 1-23 motor, 1, 3-5, 16 motors, 1, 3-5 Mount, 17 mount, 15 mounted, 1, 20 Mounting, 7, 9-10, 15, 18-19, 22 mounting, 1, 17 mounts, 20 ms, 12-13, 22

mShock, 22 Mtg, 7 Multiples, 6 multiples, 3 must, 3

N NC, 1, 6, 8, 13, 16-17 NEC, 3 NEMA, 3-4, 16-17, 21-22 nib, 4 nibGray, 4 NLDX, 1, 8 Nm, 12-13, 21 NO, 1, 6, 8, 13-14, 16-17, 23 no, 4, 22 Non, 17 non, 22 None, 17 not, 2-3, 21 Note, 9, 11, 13, 18-20 Notes, 2, 4-5, 10, 12 Number, 1-5, 8-11, 16-20 number, 1-3, 8-10, 18-20 numbers, 4-5

O of, 1-6, 8, 12, 16, 20-22 OFF, 16 off, 12 offering, 16 OLR, 17-19 ON, 16 on, 1, 3-5, 11-12, 16, 20 One, 21 Only, 5, 11 only, 4, 17 opaque, 4 Open, 2, 6-7, 9-10, 15, 17-19 operated, 1, 8 Operating, 16, 21-22 operating, 3, 12, 21-22

Index

operation, 1, 3, 8 Operational, 12 operational, 13, 22 operators, 20 option, 2, 10 Options, 16, 21 or, 1-23 Orange, 21 orange, 3 Order, 4 order, 1, 8 Ordering, 1, 8, 18-19 out, 3 over, 3 Overload, 1, 3-4, 6, 8, 10-14, 16-19, 21-23 overload, 3-4, 8-10, 12, 16, 18-21 overloads, 3 Overvoltage, 12-13, 21

P pack, 2-3 Packs, 4-5 packs, 1-5 Page, 1-2, 4-5, 8-11, 16, 18 Pages, 1-2, 4 panel, 4 Part, 3, 12-13 Parts, 8, 11 PC, 4 pcb, 22 pending, 21 Per, 3 per, 22 percent, 3 performance, 3 Phase, 1-2, 6, 8-10, 14, 16, 18-19, 21, 23 phase, 1-2, 4-5, 8, 16-17, 21, 23 Pkg, 4 plastic, 4 Plate, 9-10, 18-19 plate, 1, 5, 11, 15, 17 plus, 1, 8, 18-19 pole, 17 Pollution, 22 pollution, 12-13, 21 port, 4 Position, 4-5

position, 3-5, 22 positions, 4 possibility, 1, 8 Power, 5, 11, 17, 23 power, 16, 23 powered, 16 Pozidrive, 12-13 Pressure, 17 pressure, 5, 11, 17 prevent, 4 Product, 1-2, 8-9, 16, 18 product, 16, 22 PROFIBUS, 16 proof, 12, 16, 22 proofing, 12, 22 properly, 21 protect, 3, 16 Protection, 1-23 protection, 12, 16, 22 provide, 20 provided, 3-5 PTB, 12 pull, 1, 3, 8 pump, 3 Purpose, 1-23 Push, 3 push, 16 pushbutton, 20

Q QC, 17 QCJ, 17 QuantityDescription, 4 quick, 17

R Radiated, 23 Rail, 9-10, 18-19 rail, 15, 17 RailAmpere, 10 Range, 5, 10-11, 17, 19, 21 range, 12, 18-19

Index

Rated, 13, 21-22 rated, 13 Rating, 2-6, 9-11, 18-19, 22 rating, 3, 13 Ratings, 4-6, 17, 21-22 ratings, 5, 11, 22 read, 12 Recognized, 1, 8 reduce, 1, 8 reduces, 12 Relay, 1, 3-4, 6, 8, 10-11, 14, 16, 19 relay, 3-4, 8-10, 12, 16 Relays, 1, 8, 11-13, 16, 21-23 relays, 3 Reliable, 16 Remote, 16, 20-21 remote, 16, 20-21 Renewal, 8, 11 Replace, 2, 9-10, 18-19 Replacement, 3 required, 2, 4-5 requires, 3 RESET, 1, 3 Reset, 3-6, 14, 17, 20-21, 23 reset, 1, 3-4, 8, 16, 20-21 resethigh, 16 residual, 12 resistance, 12 response, 12 reversing, 17 rms, 23 RoHS, 17 rotate, 3 Rotor, 2, 9-10, 18-19 run, 3

S Safe, 12-13 Safety, 20 Screw, 5, 7, 11 screw, 12-13 screwdriver, 12-13 screws, 17 SDD, 19 SDF, 19 sec, 21 Seconds, 6, 14

seconds, 3 section, 12 sector, 1, 8, 16 See, 2, 10 see, 1-2, 4-5, 8, 18-19 SEL, 17 Select, 2 select, 16 Selectable, 1, 8, 16, 21 selectable, 16, 21 Selection, 1-2, 8-9, 16-18 selection, 16 Self, 16 self, 16 sensitivity, 1, 8 Separate, 2, 4, 9-10, 17-19 SeparateAmpere, 2 Series, 1, 8 Service, 3 service, 1, 3-5 Set, 2, 4-5, 19 set, 3 Setting, 3, 6, 14 setting, 3-4, 12, 21 shall, 3 shipped, 4-5 Shipping, 7, 15 shock, 1, 8, 12 Short, 13, 22 short, 3 showing, 3 shown, 3 Shrouded, 1, 8 Side, 5, 11, 17 side, 5, 11 sine, 23 Single, 1-2, 6, 8, 10, 14, 16-17, 19, 23 single, 2-5 sinusoidal, 12 Size, 3, 7, 12-13, 15 sizeand, 16 Sizes, 5, 11 sizes, 21 Snap, 4 snap, 17 SNC, 2, 9-10, 18-19 SNE, 2, 9-10, 18-19 Solid, 5, 11-13 solid, 5, 11-12 Specific, 12 specific, 1 Specification, 12-13, 21, 23 Specifications, 1, 5, 8, 11, 16, 21

Index

Specify, 1, 8, 18-19 spread, 12 SRC, 9-10, 18-19 SRE, 9-10, 18-19 Standard, 5, 12-13, 16-17, 19 Standards, 1, 3, 8, 16-17 Starers, 7 Start, 6 start, 3 Starter, 2-3, 9-10, 18 starter, 17 Starters, 1-23 state, 12 stated, 13 status, 16, 21 Std, 4 storage, 22 Stranded, 5, 11 stranded, 5, 11-13 Suffix, 2, 10-11, 19 suffix, 1-2, 8-10, 18-19 Supplied, 6, 14, 23 Support, 1-23 Surge, 23 switch, 16-17 switches, 20

T Table, 23 table, 2, 19 tables, 2, 10 Tamper, 16 target, 20 Tech, 1-23 Technical, 1, 5, 8, 11, 16, 21 Temperature, 12 temperature, 12, 16, 22 Terminal, 5, 11-13, 21 terminal, 12 Terminals, 5, 11, 17 terminals, 1, 17, 21 TEST, 8 Test, 3, 16 test, 1, 3, 8, 16 tested, 3 Tests, 3 th, 13, 23

than, 3 that, 3, 20 THD, 23 The, 3-5 the, 1, 3-4, 8, 12-13, 16, 20 Thermal, 16, 21 thermal, 13, 22 These, 12 This, 3 Three, 1-2, 4-6, 8-9, 14, 16-18, 23 three, 2, 4-5, 17, 21 threshold, 21 through, 2, 10, 17 thus, 3 Tightening, 12-13, 21 Time, 3, 6 time, 3, 12 To, 3 to, 1, 3-5, 8, 12-13, 16, 20-23 Tools, 12-13 top, 20 Torque, 5, 11 torque, 5, 11-13, 21 transient, 23 transparent, 4 Trip, 1, 3-6, 8, 14, 16, 21 trip, 1, 3-4, 8, 16, 21 tripped, 3 Tripping, 12 tripping, 12 turn, 3 Two, 16, 21 two, 3, 12, 17 Type, 2, 5, 7, 9-11, 15, 17-19

U Ue, 12-13 Ui, 12-13, 21 Uimp, 12-13 UL, 1, 3, 6, 8, 17, 22 ultimately, 3 unauthorized, 4 unbalance, 16, 21 unbalancereset, 16 underscore, 2, 9-10, 18-19 Underwriters, 3 unit, 16

Index

up, 16, 21-23 Upper, 12 us, 23 Use, 19, 21 use, 1, 10-12 User, 16 using, 12, 23

V VA, 22 Vac, 12-13, 16, 20-21 value, 12 values, 3-5, 12 various, 3 Vdc, 16, 20, 22 VDE, 8, 12-13 version, 16 Vibration, 22 Voltage, 2, 9-10, 18-19 voltage, 12-13, 21 Voltages, 21 voltages, 16 Volts, 6 volts, 3 Volume, 1-23

www, 1-23

X XCOM, 20 XRB, 20 XRR, 20 XSC, 20 XT, 1, 8, 16, 19, 21 XTOB, 11-14 XTOBP, 11

Y Yes, 21

Z ZEB, 20

W wave, 23 Welding, 22 welding, 13 When, 1, 3, 6, 8, 12, 14, 18-19, 23 when, 3, 12, 20, 22 which, 3 Wide, 7, 15 will, 3, 16 Wire, 5-6, 11, 14, 23 wire, 3, 20 Wiring, 1, 6, 8, 14, 16, 23 With, 12, 16, 23 with, 1-4, 6, 9-14, 16-19, 21, 23 without, 13, 17, 22 withstand, 12-13, 21