This document contains proprietary information and such information shall not be disclosed to any third party for any purpose whatsoever or used for manufacturing purposes without prior written agreement from Radiall. The data defined in this document are given as an indication, in the effort to improve our products; we reserve the right to make any changes judged necessary.
Technical Data Sheet STRAIGHT PLUG CLAMP TYPE CABLE 1/2" SPIRAL SUPERFLEXIBLE
PAGE 2/3
ISSUE 1416C
SERIES QLI
PART NUMBER R184037007
PACKAGING Standard 50
Unit Contact us
Other Contact us
ELECTRICAL CHARACTERISTICS Impedance Frequency 1.04 + VSWR Insertion loss RF leakage -( Voltage rating Dielectric withstanding voltage Insulation resistance
50 0-6 0.0200 0.05 NA 1400 2500 5000
ENVIRONMENTAL
GHz x F(GHz) Maxi F(GHz) dB Maxi - F(GHz)) dB Maxi Veff Maxi Veff mini M mini
50 30 NA
°C Atm.cm3/s
SPECIFICATION
MECHANICAL CHARACTERISTICS Center contact retention Axial force – Mating End Axial force – Opposite end Torque
Recommended cable(s) FSJ4RN-50B HCF1/2”CuH-50oAlCu Characteristics indicated on this data sheet are those that can be achieved with the highest performance cable. Intrinsic limitations of the cable may diminish the performance of the assembly
Cable retention 350 NA
- pull off - torque
N mini N.cm
TOOLING Part Number .
Description .
Hexagon .
OTHER CHARACTERISTICS IP67 mated condition
This document contains proprietary information and such information shall not be disclosed to any third party for any purpose whatsoever or used for manufacturing purposes without prior written agreement from Radiall. The data defined in this document are given as an indication, in the effort to improve our products; we reserve the right to make any changes judged necessary.
Technical Data Sheet STRAIGHT PLUG CLAMP TYPE CABLE 1/2" SPIRAL SUPERFLEXIBLE
PAGE 3/3
ISSUE 1416C
SERIES QLI
PART NUMBER R184037007
COMPONENTS Body
O-ring
Clamp nut
1
3
- Strip the cable. - Do not damage the outer conductor. - The end surface of inner conductor should be chamfered. - Remove impurities such as copper scraps and burrs on the end surface of the cable.
- Screw the body onto the cable assembly. - Recommended coupling torque: 950N.cm
2 - Put the O-ring onto the clamp nut. - Screw the clamp nut along the outer conductor of the cable, make sure dimension e is ok after tightening.
This document contains proprietary information and such information shall not be disclosed to any third party for any purpose whatsoever or used for manufacturing purposes without prior written agreement from Radiall. The data defined in this document are given as an indication, in the effort to improve our products; we reserve the right to make any changes judged necessary.