TRANSMITTAL

Report 12 Downloads 260 Views
TRANSMITTAL

No: SP- 25 Sent By: Pedro Peralta

To: Fore Property

Ref: Mechanical Gates for Approval [email protected] [email protected] [email protected] [email protected]

Attn: Michelle Duranleau Phone: Project: Elysian @ Hacienda WE ARE SENDING:

01-Mar-16

Date:

SUBMITTED FOR:

ACTION TAKEN:

Signed Contract

Approval

Approved As Submitted

Safety Manual

Your Use

Approved As Noted

Shop Drawings

As Requested

Returned

RFI

Payment

Other:

Permit(s)

Review & Comment

Signed Change Order Third Party Inspector Documents Close Out Documents

SENT VIA: Mail

See Remarks

Hand Delivered By:

Fax Electronically

Remarks: Mechanical Gates for Approval

Received By:

(Signature)

Date:

01-Mar-16

(Printed Name & Title)

Please Fax Completed & Signed Transmittal Form Back To: (702)222-4203

1835 PC PROGRAMMABLE

TELEPHONE E ntr y S y stem

Best suited for applications requiring complete access control for up to 24 entry points, including elevator control

• Provides both resident and visitor access control into and within apartment buildings, gated communities, condominiums, office buildings, factories and industrial sites • PC programmable. Programming and Transaction Analysis software included • Voice and data (programming) connection over either Cellular, VoIP, Wireless, or copper POTS lines • Built-in electronic directory • Large easy to use A-Z-CALL buttons • Resident access control is provided by means of cards, digital PIN codes, or wireless transmitters • 2 year limited factory warranty

surface mount

wall mount

Wireless

PoTS wireless expansion up to 24 entry points

big characters half inch LCD display

pc programmable easy to use software included

voice and remote programming use almost any phone service and retrofit to older DKS units

Access Control Solutions

1835 PC PROGRAMMABLE E ntr y S y stem 1835 Surface

1835 Flush

1835 Wall

(285mm W x 330mm H x 120.6mm D)

(305mm W x 336.5mm H x 82.5mm D)

(336.5mm W x 381mm H x 88.9mm D)

11.25” W x 13” H x 4.75” D

12” W x 13.25” H x 3.25” D

13.25” W x 15” H x 3.5” D

Surface Mount

phone # entry codes memory 3000 1000 (4-digit)

device DOOR directory elevator programming OPTIONS TRANSACTION codes CONTROL control BUFFER Single Line PC with 8000 ** 8000 3 Doors * LCD Display Yes Remote Account Events Manager Software

Flush Mount

3000 1000 (4-digit)

8000

Single Line 3 Doors * LCD Display Yes

PC with ** Gold Plated Remote Account Faceplate Manager Software

8000 Events

Wall Mount

3000 1000 (4-digit)

8000

Single Line 3 Doors * LCD Display Yes

PC with ** Remote Account Manager Software

8000 Events

1835

* Expands to 24 with Tracker Expansion Boards (wired or wireless)

** Software is included with the DKS system

Technical Features Mechanical

Specifications

Miscellaneous

Stainless steel faceplate

Single line 20 character super-twist LCD display 1/2 inch characters

Environmental: 10ºF to 145ºF (-12°C to 62°C)

Galvanized steel sub-plate Metal keypad Offset speaker holes for protection Hands free voice operation (Optional handset available on surface or flush mount only) Built-in postal lock provision, EEPROM memory Surface, Flush or Wall mounting styles Flush mount requires flush mounting kit Enclosures are rated NEMA 4x

16 VAC (2 power transformers included) Full Duplex voice communication Stores up to 3000 phone numbers, 255 area codes Max 8000 Weigand device (card codes), 10 facility codes Transaction buffer stores last 8000 events Control 3 entry points, expandable to 24 with tracker expansion boards Programmable directory codes (1 to 4 digits)

Connection Methods Cellular (powered by AT&T 4G LTE) VoIP (select your own VoIP provider) Wireless (Short distances - up to 1000 ft. max) POTS (Plain Old Telephone Service) Some of the connection methods noted may incur additional cost for required hardware and/or service subscriptions.

10 & 11 digit dialing capability

Heater kit (P/N 2600-584) recommended when temperatures routinely fall below 10°F (-12°C) ADA Compliant handset kit (P/N 1807-012) available on surface or flush mount only Camera Ready: Optional B&W or Color CCTV camera* *may require additional CCTV equipment Shipping weight approximately 20-25 Lbs (9-11 kg)

FCC (US) DUF6VT-12874-OT-T DOC (CAN) 1736 4528 A

31 security (permission) levels, 29 programmable with 4 time zones each 32 holiday schedules Four-digit entry codes Built-in clock / calendar

AT&T, the AT&T logo and all other AT&T marks contained herein are trademarks of AT&T Intellectual Property and/or AT&T affiliated companies

Hold open time zones (8) Entry code time zones True Anti-Pass Back Live Transactions feature (requires TCP/IP internet connection or RS-232 connection)

Distributed by:

Access Control Solutions since 1948

Member:

120 Glasgow Avenue, Inglewood, California 90301 U.S.A. Tel: 310-645-0023 FAX: 310-641-1586 www.doorking.com © 2015 All Rights Reserved. Product specifications may change without notice. Rev. 5/15

9024 DC VEHICULAR

SLIDE Gate OPERator

• Residential • COMMERCIAL

• Operator is 24 Volt DC and includes built-in battery backup • 115/230 VAC (switch selectable) or 24 VDC Solar Power • 1/2 HP Quadra Drive Heavy-duty DC Motor • Adjustable limit nuts for precise gate limit control • Easy to use manual T-handle release • Heavy-duty gearbox • 0.0 Amp SBPD Circuit (solar power only) • Solar power ready • Pad or post mount • Heavy-duty steel frame • 5-year limited warranty

easy to use “T-Handle” release

quadra drive DC motor for longer life

battery backup built-in (7.2 AH battery x2)

full size gearbox heavy-duty 30:1 ratio gearbox

Access Control Solutions

9024 VEHICULAR

H

OPERATOr

D

9024 1/2 HP Quadra Drive Motor 16.75” W x 28” H x 19” D

(42.5cm W x 71cm H x 48.3cm D)

W

9024-080 9024-081

(requires solar power input)

Class of Max Gate Max Gate MOTOR INPUT operation Length * Weight * I, II, III, IV 40 Ft 1000 Lbs. 1/2HP 115 / 230 VAC (12.2 m) (453.6 kg) Quadra Drive 1.8 A / 0.9 A DC Motor

MAXIMUM CYCLES Continuous with AC source 40 with 7.2 Ah backup battery power1,2 150 with 18 Ah backup battery power1,2

I, II, III, IV

150+1,2 with DK solar kit, unknown with systems / batteries provided by others



40 Ft 1000 Lbs. (12.2 m) (453.6 kg)

1/2HP 24 VDC Quadra Drive 8.5 A DC Motor

1 Assumes gate is on level ground, in good condition with properly adjusted hardware. 2 Assumes a 16 foot gate weighing 1000 Lbs. Other external factors (temperature, charge

state of batteries, gate weight, gate length, etc.) will affect the performance of the gate operator and may reduce the number of cycles shown.

Technical Features Mechanical

Electrical

Miscellaneous

Frame: 3/16 steel, corrosion protected

Adjustable partial open limit

Environmental: -10ºF to 140ºF (23°C to 62°C)

Cover: 1/4 inch polyethylene

Easy adjustable chain driven limit nuts

Reduction: belt driven 30:1 gear reduction running in a continuous oil bath

Auto-close timer 1-30 seconds

Thermostatically controlled heater kit required for operation below freezing temperatures to prevent batteries from freezing. Heater kit can only be used with AC powered operators.

Speed: Approximately 1 ft/sec (30.5 cm/sec) Chain: Unit is shipped with 20-ft of #40 roller chain Manual Release: “T-Handle” release is easily accessible from front of operator Operator re-connects automatically when handle is released

Options Nickel or stainless steel chain Steel base plate for post mounting 18 Ah batteries (AC powered operator only) Solar Kit (Includes two 18 Ah batteries and 10 Watt, 24 VDC solar panel)

Selectable loop/reverse input function; stop or reverse Anti-tailgating feature helps to control un-authorized traffic Standard normally closed stop circuit DC Power Shut-Off switch

External entrapment/obstruction sensing devices must be used with this operator Shipping weight approximately 130-150 Lbs (59-68 kg) Depending on model and options selected

Battery protection circuit Ports for plug-in open and reverse loop detectors – DKS detectors only Gate Tracker reporting output provides operator data to access control system (DKS 1833, 1835, 1837 or 1838 only) AC Powered Operator Only 115 VAC Convenience outlets AC Power Shut-Off switch DC Powered Operator Only 0.0 Amp SBPD PatPend Circuit

Distributed by:

Access Control Solutions since 1948

Member:

120 Glasgow Avenue, Inglewood, California 90301 U.S.A. Tel: 310-645-0023 FAX: 310-641-1586 www.doorking.com © 2014 All Rights Reserved. Product specifications may change without notice. Rev.11/14

MicroCLIK

®

RF CONTROL A cc e s s control

• Gated Communities • APARTMENT COMPLEXES • Parking • Condominium/Resident Hall • Mixed­Use • Commercial • Self Storage • MAXIMUM SECURITY

• Keychain transmitter provides long range (up to 75-ft.) remote operation of garage doors or vehicular access gates • Over 1,000,000 transmitter codes available • PROXmitter® includes a built-in proximity card reader providing both RF and card access control into a single compact unit • MicroCLIK RF controls may be used as a stand-alone access control system or can be interfaced with 26, 30 or 31-bit weigand controllers • 2 year limited factory warranty

optional visor clip use to mount transmitter in vehicle

safety/convenience from inside your vehicle

receiver options

available to fit specific applications

compatible

with Homelinktm system

Access Control Solutions

7

4

1

0 * #0

8 7 98

5 4 65

2 1 32

9

6

3

#

*

1 2 3 4 5 16 27 38 4 5 6 7 8

MicroCLIK RF CONTROL Transmitters

Receivers

1.44” W x 2.5” H x .5” D

3.75” W x 5.75” H x 1.13” D

(36.6mm W x 63.5mm H x 12.7mm D)

(95.3mm W x 146mm H x 28.7mm D)

TYPE MAX

PROG FAC TIME HOLD OPEN ZONES CAPABILITY - - -

MicroCLIK codes codes*

Wiegand



Stand Alone



RF - Control RF

16,000

10 -

OUTPUT MAX ACCESS PTS 26, 30 or 31-bit - Wiegand

No 1 Relay

1

POWER 12-24 VAC/DC 12-24 VAC/DC

RANGE 50-75 Ft

50-75 Ft

* Programmable Facility Codes

Technical Features Receivers

Transmitters

Electrical

Model 8057: Stand-alone receiver can support up to 16,000 transmitters and has a built-in keypad to easily add or delete transmitter codes.

1,000,000 codes available

Receivers - 12-24 volt AC or DC power

Available with 1, 2 or 3 buttons

Transmitters – 12 Volt type 23A battery

Model 8040: Designed for interface with with access controllers such as the DKS 1833, 1835, 1837, or 1838. Sends the received transmitter data to an access controller in 26, 30 or 31-bit wiegand formats. Supports up to 5300 transmitters. This receiver can also be used in a stand alone configuration that can store up to 5300 transmitter codes.

PROXmitters include built in proximity access card

Output

Powered with a 12-volt, type 23A battery (replaceable)

Model 8057 Receiver Dry contact form C relay (30V, 1A max)

PROXmitters combine the MicroCLIK transmitter with a built in proximity tag

The 8040 Receiver is also a low power draw unit designed specifically for the solar application.  It remains in a “sleep” mode until it receives a signal from a transmitter. When in sleep mode, it draws about 1 milli-amp of power.

Model 8040 Receiver 26, 30 or 31-bit wiegand Dry contact form C relay (30V, 1A max)

PROXmitters are available with DK Prox, AWID, HID or RF Logistics proximity tag

FCC (US): LSD8059RX

Key ring included with transmitters

Optional visor clips are available

FCC (US): LSD69T DOC (CAN): 1736 102 138

Distributed by:

Access Control Solutions since 1948

Member: 120 Glasgow Avenue, Inglewood, California 90301 U.S.A. Tel: 310-645-0023 FAX: 310-641-1586 www.doorking.com © 2013 All Rights Reserved. Product specifications may change without notice. Rev. 4/13

IRB-MON Operating Instructions

OPERATING INSTRUCTIONS

UNIVERSAL SAFETY PHOTOEYE UL325-2016 MONITORED DEVICE

4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: [email protected] Technical Support: [email protected] www.emxinc.com

Contents

Cautions and Warnings

2

Product Overview

2

Specifications

3

Configuration settings and indicators

3

Installation

4

Verification and operation

5

Troubleshooting

6

Ordering Information

7

Accessories

7

Warranty

7

IRB-MON Operating Instructions Document no. 10280104

1

Cautions and Warnings 1.

Read and follow all operating and Installation instructions.

2. Always follow gate operator manufacturer installation instructions regarding installation of TYPE B1 sensor to the operator. 3. Disable the gate so it is unable to move. Refer servicing to qualified service personnel. IMPORTANT: This product is an accessory or part of a system. Always read and follow the manufacturer’s instructions for the equipment before connecting this product. Comply with all applicable codes and safety regulations. Failure to do so may result in damage, injury or death.

Product Overview The IRB-MON is a thru-beam photo eye and is an external entrapment protection device type B1, non-contact sensor for use with automatic gates and doors. The light beam is near infrared and pulses at a rate of 300/second (300Hz). The IRB-MON provides a signal to the gate or door operator that the beam is not obstructed. The operating range is up to 115ft. The IRB-MON operates over a wide range of 6-35VDC and 12-24VAC. A green alignment indicator on the receiver provides status information at a glance, making set-up and alignment easy. The IRB-MON includes 3 selectable operating configurations providing compatibility with most operators that accommodate monitored external entrapment protection devices per UL3252016. REFER to operator installation instructions for proper configuration selection. 

CONFIGURATION 0 - NON-MONITORED and MONITORED Intended for use with operators that require simple relay contact activation to indicate beam obstruction. Reference Light ON/Dark ON setting. Jumper available for compatibility with Normally Open 10K termination operators.



CONFIGURATION 1 – MONITORED, HEARTBEAT 300Hz / 0Hz Intended for use with operators designed to accept a “heartbeat” form of monitoring, 300Hz when aligned, no obstruction, 0Hz when beam is obstructed.



CONFIGURATION 2 – MONITORED, HEARTBEAT 300Hz / 2Hz / 0Hz Intended for use with operators designed to accept a “heartbeat” form of monitoring, 300Hz when aligned, no obstruction, 2Hz when beam is obstructed, and 0Hz for a failure.

IRB-MON Operating Instructions Document no. 10280104

2

Specifications Specifications Operating range Detection angle Sensitivity adjustment Power indicator Detect indicator Mode selection switch Relay output operation Relay output Power protection Transmitter power cycle Power (see Cautions and Warnings) Current (Config. 0) Current (Config 1 & 2) Operating temperature Environmental Dimensions (L x W x H) Weight Connections

Up to 115 ft. (35m) 24° potentiometer Green LED Flashing green LED 3 modes: relay output, pulsed (3 frequency), pulsed (2 frequency Light ON/dark ON Form C contacts (NO, COM, NC) Thermal fuse >300mS (for use in configuration 0 Monitored) 6…35VDC, 12…24VAC (Configuration 0 RELAY only) 60mA (relay activated) 15mA (12VDC, includes TX and RX wired in parallel) -40°…170°F (-40°…77°C) NEMA 4X 2.3” (57mm) x 2.6” (65mm) x 3.7mm (94mm) TX – 0.35 lbs (159g), RX - 0.35 lbs (159g), TX – 2 terminals, RX – 5 terminals

Configuration settings and indicators CONFIGURATION SETTINGS - Remove power when changing configuration settings SW4 SW3 SW2 SW1 FUNCTION X X OFF OFF Configuration 0 - relay operation, no frequency output X X OFF OFF Configuration 0 – Install jumper in 10K position for resistor termination across N.O. contact configuration X X OFF ON Configuration 1 - heartbeat output, 300Hz, 0Hz, no relay activation X X ON OFF Configuration 2 - heartbeat output, 300Hz, 2Hz, no relay activation X X ON ON Configuration 0 - relay operation, no frequency output ON X X X Dark on - N.O. contact closed when beam obstructed OFF X X X Light on – N.O. contact closed when beam is not obstructed

GREEN STATUS INDICATOR IRB-MON-T (transmitter) IRB-MON-R (receiver) IRB-MON-R (receiver) IRB-MON-R (receiver)

IRB-MON Operating Instructions Document no. 10280104

ON Flashing ON OFF

Power Blocked beam or not aligned Aligned Receiver/Transmitter are too close See Troubleshooting Guide

3

Installation Install the IRB-MON according to instructions from the gate operator manufacturer. The intent of External Entrapment Protection Device Type B1 non-contact sensor is to protect a person from being accidentally injured by the moving gate or door. DO NOT USE 12-24VAC IN PULSE CONFIGURATIONS. 1. Disconnect the IRB-MON from power before installing or servicing the device. 2. Always follow the instructions of the gate operator manufacturer regarding installation of type B1 sensors on the gate operator. The instructions of the gate operator manufacturer always supersede any instructions given in this or any other instructions by EMX Industries Inc. 3. Connect the IRB-MON power supply per requirements indicated in the specification table. 4. When using the relay outputs, do not exceed the voltage/current ratings indicated in the specification table. 5. Connect power to the terminals on the transmitter marked “TX”, polarity is not required. 6. Connect power to terminals marked “POWER INPUT” on the receiver, marked “RX” polarity is not required. IRB-MON Operating Instructions Document no. 10280104

4

7. FOR CONFIGURATION 0 ONLY. Operators that require normally closed contact for entrapment protection, connect terminal NC and COM to the designated terminals in the gate operator. Operators that require normally open contact for entrapment protection, connect terminals COM and NO to the designated terminals in the gate operator. 8. Install the IRB-MON according to instructions from the gate operator manufacturer. The intent of External Entrapment Protection Device Type B1 non-contact sensor is to protect a person from being accidentally injured by the moving gate or door. 9. The IRB-MON is housed in a NEMA 4X enclosure. To insure the integrity of the enclosure make sure the covers are attached and closed tight using all four plastic screws provided. The wiring to the enclosure must enter via UL Listed watertight fitting such as a strain relief or watertight conduit connector. 10. The IRB-MON must be powered by Class 2 circuits only, wiring must be segregated from other circuits or insulation must be provided that is suitable for the highest voltage for those circuits. 11. NOTE: REDUCE SENSITIVITY (COUNTER-CLOCKWISE) WHEN INSTALLING AT