Vandal Resistant Wraparound / 1, 2, 3 or 4-Lamp T8 PROJECT INFORMATION Project Name

Type

Catalog No.

Date

CONSTRUCTION

Heavy 16 gauge cold rolled steel housing. BALLASTS

Energy efficient, thermally protected, automatic resetting, Class P, high power factor, sound rated A, unless otherwise specified. CEE NEMA Premium compliant.

FEATURES • Ideal for vandal-prone areas, such as schools, hallways, dormitories, restrooms, bus stops, and locker rooms • Effective, secure illumination mounts to ceilings or walls • Rugged, 16 gauge heavy duty steel housing • Diffuser is UV stabilized .130" thick, one-piece, prismatic polycarbonate for high-impact protection • Formed end cap welded to housing for additional strength • Wireway extends below lamp to protect lamp for impact breakage • White powder coat finish painted after fabrication • For ceiling, wall, or pendant–individual or in continuous row • Six tamper-resistant screws protect against unauthorized entry • Wet location (covered ceiling mount), Damp Location (Wall Mount)

ELECTRICAL

Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA Premium compliant. All ballast leads extend a minimum of 6" through access location. NEC/CECcompliant ballast disconnect is standard.

FINISH

Painted parts are treated with a five stage phosphate bonding process and finished with a high reflectance baked white enamel. SHIELDING

Diffuser is of 0.130" thick clear prismatic polycarbonate material. CERTIFICATION

All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924.

ORDERING INFORMATION 4

VR

EXAMPLE VRW4-332-3EU 32



MODEL

WIDTH

SIZE

NO. OF LAMPS

VR Vandal Resistant Wraparound

N Narrow (5 1⁄8") M Medium (8 5⁄16") W Wide (12 5⁄16")

4 4'

1 2 3 4

One (VRN) Two (VRN, VRM) Three (VRW) Four (VRW)

U



LAMP TYPE

BALLAST

32 4', T8: 32, 30, 28 or 25 Watt

E Electronic T8, Instant Start 3E 3-Lamp Electronic T8, Instant Start 4E 4-Lamp Electronic T8, Instant Start



VOLTAGE U 120V-277V

OPTIONS EL Emergency Battery Pack NYC NYC Compliant NYCU NYC Compliant, Union Label

ACCESSORIES (ORDER SEPARATELY) VDR GLRK S18 SS18

Page 1/2 Rev. 06/19/17

Tamper Resistant Screwdriver Fast Blow Fuse Kit 18" Stem, Canopy 18" Swivel Stem - 45° Swivel

WRAPS / VR

© 2009 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com

VR

Vandal Resistant Wraparound / 1, 2, 3 or 4-Lamp T8

PHOTOMETRIC DATA AVG. LUMINANCE (Candela/Sq. M.)

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

7036 6275 5688 4837 3884 3071 2410 1942 1582 1365 1332 1221

7036 6547 5804 4936 4124 3381 2787 2412 2215 2129 1951 1795

7036 6548 5669 4848 4251 3715 3155 2728 2631 2674 2758 2804

56 Surface 0º = 90  90º = 90

ZONAL LUMEN SUMMARY

0º = 1.21  90º = 1.46 Length: 3.96 Width: 0.44 Height: 0.22

LUMINAIRE DATA Luminaire

7036 6414 5625 4594 3732 3273 2806 2260 1786 1305 1136 954

Zone 0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

7036 6499 5584 4753 4240 3864 3450 3061 2968 2948 3098 3399

Lumens % Lamp % Fixt. 953 1588 2606 3310 497 613 736 760 4071

17.0 28.4 46.5 59.1 8.9 11.0 13.1 13.6 72.7

23.4 39.0 64.0 81.3 12.2 15.1 18.1 18.7 100.0

COEFFICIENTS OF UTILIZATION (%) RC RW 1 2 3 4 5 6 7 8 9 10

70 76 69 63 58 53 49 46 42 40 37

80 50 30 72 69 63 58 55 50 49 43 44 38 40 34 36 30 33 27 30 24 28 22

10 66 54 45 38 33 29 26 23 21 19

70 72 66 60 55 51 47 44 41 38 36

70 50 30 69 66 60 56 53 48 47 42 43 37 38 33 35 29 32 26 29 24 27 22

10 63 52 44 37 32 28 25 22 20 18

50 63 56 49 44 40 36 33 30 27 25

50 30 61 52 45 39 35 31 28 25 23 21

INDOOR CANDELA PLOT 10 59 49 41 36 31 27 24 21 19 18

0 0 48 41 35 30 26 23 20 18 16 15

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

ENERGY DATA Total Luminaire Efficiency

72.7%

Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

67 Noncompliant $3.58 based on 3000 hrs. and $0.08 per KWH

AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%)

VRW4-432-4E Vandal Resistant Wraparound 16" × 48" 4-Lamp with Prismatic Polycarbonate Lens B432I120RH 0.88 F32T8 2800 106 Surface 0º = 90  90º = 90 0º = 1.22  90º = 1.37 Length: 3.96 Width: 1.29 Height: 0.19

0.0 22.5 45.0 67.5 90.0 0 30 40 45 50 55 60 65 70 75 80 85

5976 5526 4963 4086 3212 2671 2253 1921 1617 1326 1049 890

5976 5539 5146 4288 3293 2640 2024 1521 1269 1118 1135 1000

5976 5769 5315 4265 3479 2823 2136 1604 1340 1268 1293 1285

5976 5886 5226 4246 3588 3010 2341 1768 1466 1384 1481 1617

5976 5958 5175 4099 3575 3223 2743 2205 1785 1476 1567 1964

ZONAL LUMEN SUMMARY Zone

0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180

Lumens % Lamp % Fixt. 2270 3737 5815 6678 327 370 417 429 7107

20.3 33.4 51.9 59.6 2.9 3.3 3.7 3.8 63.5

31.9 52.6 81.8 94.0 4.6 5.2 5.9 6.0 100.0

RCR

Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet

0 30 40 45 50 55 60 65 70 75 80 85

VRN4-232-E Vandal Resistant Wraparound 5" × 48" 2-Lamp with Prismatic Polycarbonate Refractor E232PI120GO1 0.92 F32T8 2800

Average Luminance Angle

Luminaire

Average Luminance Angle

LUMINAIRE DATA

Test HP07297 Test Date 7/29/1997

RCR

0.0 22.5 45.0 67.5 90.0

RC RW 1 2 3 4 5 6 7 8 9 10

70 69 63 58 54 50 46 43 40 38 35

80 50 30 66 64 59 55 52 48 47 42 42 37 38 33 35 30 32 27 30 25 27 23

10 61 52 44 38 33 29 26 24 21 19

70 67 61 57 52 48 45 42 39 36 34

70 50 30 64 62 57 54 51 47 46 41 41 37 38 33 34 29 31 27 29 24 27 22

10 60 51 43 38 33 29 26 23 21 19

50 61 54 49 44 40 36 33 30 28 26

50 30 59 51 45 40 35 32 29 26 24 22

Test HP07299 Test Date 7/31/1997 10 58 49 42 37 32 29 26 23 21 19

0 0 51 44 38 34 30 26 23 21 19 17

INDOOR CANDELA PLOT

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

ENERGY DATA Total Luminaire Efficiency

63.5%

Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

59 Noncompliant $4.07 based on 3000 hrs. and $0.08 per KWH

DIMENSIONAL DATA 483/4" 24"

VRN (Narrow) 51/8" Wide 51/8"

51/8" 2" Dia. KO

33/4" VRN

1/2" Dia. KO 483/4" 24"

125/16" VRM (Medium) 85/16" Wide

23/4"

85/16"

85/16" 11/5" Dia. KO & Keyholes 23/4" VRM

VRW

483/4" 24"

7/8" Dia. KO

VRW (Wide) 125/16" Wide

125/16"

11/2" Dia. KO & Keyholes

7/8" Dia. KO

NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 2/2 Rev. 06/19/17 WRAPS / VR © 2009 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com