Premium Industrial / 2-Lamp T5, T5HO, T8 PROJECT INFORMATION Project Name
Type
Catalog No.
Date
CONSTRUCTION
Heavy steel housing with longitudinal reinforcing ribs for extra strength. Reflector die-embossed with transverse ribs for maximum rigidity. Deep Vee center channel provides 30° crosswise shielding. Smooth, extruded apertures provide 18% uplight.
FEATURES • • • • • • •
Available in 4' and 8' lengths Reflectors have 18% uplight and 30° transverse shielding Spring loaded turret lampholders 6" lamp spacing For individual or continuous row mounting Channel ends double as joiners Full depth end closures available
FINISH
White painted parts are treated with a five stage phosphate bonding process and finished with a high reflectance baked enamel. BALLASTS
ELECTRICAL
Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA Premium compliant. All ballast leads extend a minimum of 6" through access location. NEC/CECcompliant ballast disconnect is standard. CERTIFICATION
All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924.
Energy efficient, thermally protected, automatic resetting, Class P, high power factor, sound rated A, unless otherwise specified. CEE NEMA Premium compliant.
ORDERING INFORMATION KL
–
MODEL
2
32
NO. OF LAMPS IN CROSS SECTION
KL Premium Industrial
2 Two
EXAMPLE KL4-232-VR-EU-GLR –
VR
–
REFLECTOR TYPE VR Deep V Reflector Apertured for Uplight (Not available with solid top)
SIZE
LAMP TYPE
4 4' 8 8'
32 4', T8: 32, 30, 28 or 25 Watt
– BALLAST
VOLTAGE
E Electronic T8, Instant Start 4E 4-Lamp Electronic T8, Instant Start EP Electronic T8, Program Start 4EP 4-Lamp Electronic T8, Program Start For others available, see Ballast Options.
U 120V-277V 347 347V
Use programmed start ballast. Not recommended for use with instant start. For more occupancy/daylight harvesting sensor accessories see Technical section.
1
Page 1/2 Rev. 08/27/14 © 2014 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
OPTIONS GLR GMF EL BC
Fast Blow Fuse Slow Blow Fuse Emergency Battery Pack Branch Circuit Plug-on Wiring System (See options section for details.) PAF Paint After Fabrication NYC NYC Compliant NYCU NYC Compliant, Union Label
ACCESSORIES (ORDER SEPARATELY) KZT Zip Tee Hanger - 1½" spacer on T-bar ceiling KTH Slide Clamp Tong Hanger S18 18" Stem, canopy and 8° aligner SS18 18", 45° Swivel Stem & Canopy KHC 24" Chain Hanging Assembly KLEC Full Depth End Closure KLWG4 Wire Guard 4' lg. - 2 required per 8' fixture OS1360K Occupancy/Daylight sensor kit, 120/277/347V, one relay, 360 Lens, snap on drop down adaptor, quick connect wiring1 Note: KLEGG not available with V reflector fixtures INDUSTRIALS / KL VR BI-PIN
KL VR BI-PIN
Premium Industrial / 2-Lamp T5, T5HO, T8
PHOTOMETRIC DATA
ZONAL LUMEN SUMMARY Zone
LUMINAIRE DATA
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
KL4-232-VR-EB8-PAF KL Industrial 1' × 4' White Painted Apertured “V” Reflector with Slotted Top B232I120RH 0.88 FO32/41K BAL. FAC.: .88 2900 63 N/A 0º = 1.27 90º = 1.34 Length: 3.92 Width: 1.02 Height: 0.08
Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet
1195 1984 3462 4208 196 308 606 937 5145
20.6 34.2 60.0 72.5 3.4 5.3 10.4 16.2 88.7
ENERGY DATA
23.2 38.6 67.7 81.8 3.8 6.0 11.8 18.2 100.0
INDOOR CANDELA PLOT
RCR
70 93 85 78 71 65 60 56 52 49 45
80 50 30 89 86 78 73 69 62 61 54 55 47 49 42 44 37 40 33 37 30 34 27
10 83 68 57 48 41 36 32 28 25 23
70 89 81 74 68 63 58 54 50 46 44
70 50 30 86 83 75 70 66 60 59 52 53 46 47 40 43 36 39 32 36 29 33 27
10 80 66 55 47 41 35 31 28 25 22
50 79 69 61 55 49 44 40 37 34 31
50 30 77 65 56 49 43 38 34 31 28 26
10 74 62 52 45 39 34 30 27 24 22
88.7%
Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
72 Non-Compliant $3.33 based on 3000 hrs. and $0.08 per KWH
AVG. LUMINANCE (Candela/Sq. M.)
COEFFICIENTS OF UTILIZATION (%) RC RW 1 2 3 4 5 6 7 8 9 10
Total Luminaire Efficiency
Average Luminance Angle
Luminaire
Test L11148 Test Date 1/8/03
Lumens % Lamp % Fixt.
0 0 61 52 44 38 33 29 25 23 20 18
0 30 40 45 50 55 60 65 70 75 80 85
0.0
22.5
45.0
67.5
90.0
4092 4012 3921 3854 3762 3671 3547 3357 3115 2822 2251 1252
4092 3945 3859 3793 3752 3681 3693 3702 3192 2076 1493 1209
4092 3938 3907 3996 4052 3696 2790 2016 1651 1460 1277 1133
4092 3939 4132 4035 3326 2489 1914 1647 1477 1353 1204 1079
4092 4003 4214 3827 2957 2203 1778 1592 1457 1336 1213 1108
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
DIMENSIONAL DATA
MOUNTING ACCESSORIES 9813/16" 887/8"
2"
2"
11/8" 15/16" 431/32"
4913/32"
497/16" 39½"
2" 15/16" 431/32"
11/8"
2"
39½" KHC
S18
43/16" 7/8" Dia. Knockout
2½" 37/8" 6" 13¼"
KZT
KTH
A: 7/8" Diameter knockout B: .570" × .656" Strain Relief knockout E: 11/8" Diameter knockout NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.
Page 2/2 Rev. 08/27/14 © 2014 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com