ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp (see page ... Duty cycling. Ventilating fans ... DUTY CYCLE: Settings of 1⁄60 th of dial speed . CATALOG.

8000 SERIES

SPECIFICATIONS

MULTIPLE ON/OFF CYCLES PER DAY REPEATING VARIABLE CYCLE TIME SWITCH

INPUT VOLTAGE: 120VAC, 60Hz.

APPLICATIONS

24 HOUR WATER HEATER TIME SWITCH

INPUT VOLTAGE: 208 – 250V 60 Hz. TIMING ACCURACY: Line frequency.

TERMINAL RANGE: #8 - #14AWG.

TERMINAL RANGE: #8 - #14AWG.

OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).

OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).

REPLACEMENT TRIPPERS: #P49 for a pair with one ON and one OFF per dial for additional ON/OFF trippers per dial order #P47. 3 omitting screws #53005 supplied. ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp (see page 153 for enclosure dimensions).

For one or many daily ON/OFF operations.

SPECIFICATIONS

TIMING ACCURACY: Line frequency.

POWER CONSUMPTION: 3 watts maximum.

Duty cycling Ventilating fans Pumping Irrigation Process control Laboratory experiments

WH2

APPLICATIONS

SAVE ENERGY!

POWER CONSUMPTION: 3 watts maximum.

Avoid utility peak rates Turn off when not needed

Automatic ON/OFF control of electric water heaters. Schedules the water heater to turn ON only when needed, avoiding energy waste when hot water is not needed.

ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp (see page 153 for enclosure dimensions).

CONTACT RATINGS CONTACT RATINGS

FEATURES SCHEDULING: 60 captive tabs per dial with minimum ON/OFF settings: – 60 minute dial with 1 minute tabs. – 30 minute dial with 30 second tabs. – 12 minute dial with 12 second tabs. – 6 minute dial with 6 second tabs.

TYPE

VOLTAGE

CONTACT RATING

Resistive

120 or 240VAC 480VAC

20A 20A

Motor

120VAC

3/4 HP

CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 60Hz

OUTPUT CONTACTS

TYPE

8601

70034

120

SPDT

60 Minute

8301

70033

120

SPDT

30 Minute

8121

70032

120

SPDT

12 Minute

C L

H

120

SPDT

6 Minute

120VAC N

Replacement For 8601 #102, for 8301 #108, for 8121 #107, and for 8061 #105. Motor Replacement #P49 for a pair with one ON and one OFF per dial for additional ON/OFF Trippers trippers per dial order #P47. 3 omitting screws #53005 supplied.

ELECTROMECHANICAL PHOTOCONTROLS CONTROLS TORK 39

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

NC

TYPE

VOLTAGE

CONTACT RATING

Resistive

208-277VAC

40 A, 10,000W

Replacement Motor

#201 (208-277V)

Replacement Trippers

Order #P47 for a pair of ON/OFF trippers

EXTERNAL MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF automatic operation then resumes.

M

ALL SPDT MODELS

ORDERING INFO

70031

SCHEDULING: Minimum ON is setting 20 minutes with a minimum OFF setting of 75 minutes. Dial accommodates up to 12 pairs. 3 pairs of trippers supplied.

WIRING DIAGRAMS

DUTY CYCLE: Settings of 1⁄60 th of dial speed.

8061

FEATURES

WIRING DIAGRAMS TYPICAL FOR 240 VOLT SUPPLY

ORDERING INFO

NO 2

LOAD 2 CLOSED WITH TAB OUTWARD

CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 60Hz

OUTPUT CONTACTS

ENCLOSURE TYPE

WH2

70042

208-250

DPST

Metal Indoor NEMA 1

M

H H

L

1

2

X LOAD

LOAD 1 CLOSED WITH TAB INWARD

TORK 40 40 TORK

Recommend Documents
8000 SERIES. MANY DAILY ON/OFF. OPERATIONS PER DAY. DUTY CYCLE. 24 HOUR TIME SWITCH. Duty cycling. Ventilating fans. Pumping. Irrigation. Process control. Laboratory experiments. For one or multiple daily. ON/OFF operations . SCHEDULING: Minimum ON s

The devices are Underwriters. Laboratory (UL, USA and ULC, Canada) listed for Panic Exit Hardware or Fire Exit Hardware, and are certified to ANSI.

Wood. Electrical. • .24 Amps at. 12 VDC/VAC. • .12 Amps at. 24 VDC/VAC .... For use with: Extended lip for 'knock-down' style frame installations. For use with ...

No cutting on frame required. Vertical adjustability to ... Strike body width decreased to 1-7/16" to increase frame compatibility. Five year limited warranty.

Camden Door Controls offers the widest range of high quality, feature rich and affordable pneumatic 'Request to Exit' switches in the industry. All switches ...

OPTIONAL RESERVE POWER: “L” models keep dial on time up to 16 hours during power outage . INPUT VOLTAGE: 120, 208-277VAC or. 480VAC, 60Hz ...

BlackDiamond® 8800 series switches simplify enterprise, data center and service .... port and a range of QoS technologies that can prioritize and .... 128. 128. 128. 128. Layer 2 MAC FDB. 128k. 512k. 512k. 512k. 32k. 32k. 32k. 8k. 32k. 32k.

Includes the 801 and 801A faceplates in the box. Model 8000C includes a 801 and a 801A faceplate in the box. The 8000. Series is also available in a Complete. One Box. Solution. INT. EGR. A. T. ED. PR. ODUC. T. S. C. A. BINE. T LO. CK. S. AC. C. ES.

These meters are designed for use with TSP or HSP transmitters. The meter can be used for either local or remote indication of the sensed variable. All meters of the ASP-500 series are zero suppressed - taut band - 100° flat arc movement type with a

S-8300. 300Vac/dc. 30. 25. Mounting Dimensions. No. of. Inches. Millimeters. Poles. A. B. A. B. 1. – ... Varies with number of poles. Contact customer service. BK/.