SUBMITTAL COVER SHEET PROJECT NAME LOCATION ARCHITECT ENGINEER CONTRACTOR SUBMITTED BY
DATE
UNIT SUMMARY Quantity Unit Designation Model No. Total Cooling Sensible Cooling Air Ent. Evaporator Air Lvg. Evaporator Heating Input Heating Output CFM/ESP EER/SEER Electrical Minimum Ampacity Min.-Max. Breaker Net Unit Weight Accessory Catalog Form Number
ACCESSORIES:
NOTES:
PRINTED IN U.S.A 01/12 QG FORM NO. M11-1640
FORM NO. X33-1446
SUBMITTAL SHEET FOR PACKAGE GAS ELECTRIC RGEA16 SERIES, Nominal Sizes 2-5 Tons [7.0-17.6 kW] FRONT VIEW
BACK VIEW
207/8" [530 mm]
39/16" [90 mm] SIDE SUPPLY DUCT OPENING
FIELD POWER WIRE ENTRANCE FIELD CONTROL WIRE ENTRANCE
LIQUID PRESSURE SERVICE PORT SUCTION PRESSURE SUCTION PORT
47/16" [113 mm] 81/2" [216 mm] TYP.
143/16" [360 mm] TYP.
SIDE RETURN DUCT OPENING
SHOWN WITH DUCT COVERS REMOVED.
SIDE VIEW FLUE EXHAUST HOOD
UNIT DATA COOLING PERFORMANCE TOTAL CAPACITY* ........................ _______ MBH SENSIBLE CAPACITY* .................. _______ MBH OUTDOOR DESIGN TEMP. _______ °F [°C] DB/WB TOTAL SUPPLY AIR ................ _______ CFM [L/s] TEMP. OF AIR ENTERING EVAPORATOR COIL...... _______ °F [°C] DB/WB POWER INPUT REQUIREMENT ........ _______ kW SEER/EER RATING ................................ _______
GAS SUPPLY ENTRANCE
1015/16" [278 mm] 21/2"
[63.5 mm]
SIDE VIEW FILTER ACCESS PANEL (FOR UNIT MOUNTED FILTER ACCESSORY)
OUTDOOR COIL PROTECTIVE GRILLE
111/16" [42.9 mm]
BLOWER/ EVAPORATOR ACCESS PANEL
(*uses blower motor heat)
HEATING PERFORMANCE GAS HEAT INPUT CAPACITY.......... _______ MBH GAS HEAT OUTPUT CAPACITY ...... _______ MBH STEADY STATE EFFICIENCY ................ ________
SUPPLY AIR BLOWER PERFORMANCE TOTAL SUPPLY AIR ................ _______ CFM [L/s] TOTAL RESISTANCE EXTERNAL TO UNIT...................................... _______ IWG BLOWER SPEED .......................... _______ RPM POWER OUTPUT REQUIREMENT .. _______ BHP MOTOR RATING ........................ _______ HP [W] POWER INPUT REQUIREMENT ........ _______ kW
527/16" [1332 mm]
ELECTRICAL DATA POWER SUPPLY...................... ____________ Hz TOTAL UNIT AMPACITY................ _______ AMPS MINIMUM WIRE SIZE .................... _______ AWG MAXIMUM OVERCURRENT DEVICE FUSES HACR BREAKER ........ _______ AMPS
Full Perimeter Curb
TOTAL UNIT WEIGHT TOTAL OPERATING WEIGHT .... _______ LBS [kg] (including field-installed accessories)
CLEARANCES FRONT
48" [1219 mm]
CONDENSER COIL
18" [457 mm]
DUCT SIDE
12" [305 mm]
EVAPORATOR END
36" [914 mm]
ABOVE UNIT
60" [1524 mm]
[ ] Designates Metric Conversions
479/16" [1208 mm]
451/16" [1145 mm] INSIDE
TOP VIEW
BOTTOM VIEW
13/16" [30 mm] TYP.
11/2" [38 mm] TYP.
BOTTOM RETURN DUCT OPENING
5013/16" [1290 mm]
153/8" [391 mm]
191/2" [495 mm]
497/16" [1256 mm] INSIDE
BOTTOM SUPPLY DUCT OPENING
141/4" [362 mm] TYP.
OUTDOOR FAN GRILLE & COMPRESSOR ACCESS
33/16" [97 mm]
313/16" [97 mm]
[ ] Designates Metric Conversions
49/10" [125 mm]
FEATURES 1. All models feature Scroll ® compressors for maximum efficiency and quiet operation. 5 Ton RGEA16 models feature UltraTech™ Scroll 2-Stage compressors with Comfort Alert™ diagnostics (see below), high/low pressure switches, and hard start kits. 2. Louvered condenser compartment for protecting the coil against yard hazards and/or weather extremes. 3. One-piece top with a deep flange to help keep water out of the unit. 4. Supply and return air openings feature a one-inch tall flange to prevent water migration into the ductwork. 5. Access panels have “weep holes” and channels to further help manage water run-off. 6. Side and down discharge options available on all models. All models are shipped ready for horizontal application. 7. Easily accessible blower section complete with slide-out blower. The RGEA16 comes standard with variable speed motor with adjustable airflow in heating and cooling. The variable speed motor also comes with a interface that allows for dehumidification when used in continuous humidistat. The variable speed system is capable of 1 inch external static. 8. Refrigerant connections are conveniently located for easy service diagnostics. 9. Condenser and evaporator coils feature enhanced fins for better heat transfer and rifled copper tubing for greater efficiency.
10. Inside the easily accessible furnace compartment is the draft inducer motor. This motor is specially designed for quiet reliable operation. In addition to the draft inducer motor, the in-shot gas burners and manifold efficiently regulate the flow of gas for combustion. These new gas/electric units also feature direct-spark ignition and remote flame sensors for added reliability and efficiency. 11. All units feature an internal trap on the condensate line eliminating the need for installing an on-site external trap. 12. Easily accessible control box. 13. Single point wiring simplifies installation. 14. Our gas/electric package units feature a tubular heat exchanger design. Tubular heat exchangers are more efficient and durable than older-style clamshell heat exchangers. Stainless Steel Heat Exchanger is a standard feature on the RGEA16 and is backed by a limited lifetime warranty when installed in a residential application, and a 20 year warranty when installed in a commercial application. Two stage gas heat is standard on the RGEA16 models. 15. Thermal expansion valve standard on all models for superior superheat control, reliability, and energy efficiency at all operating conditions. 16. Filter drier standard on all models (not shown). 17. Rugged baserail included for improved installation and handling 18. Complete factory charged, wired and run tested. 19. Molded compressor plugs.
FIELD INSTALLED ACCESSORIES Roof Curb (8" [203.2 mm], 14" [355.6 mm] & 24" [609.6 mm] High Full Platform)........................ Roof Curb (14" [355.6 mm & 24" [609.6 mm] Sloped Platform) .................................................. Filter Accessory.......................................................... Lift Kit (For Rigging) .................................................. Time Delay Relay ...................................................... Start Assist ................................................................ Low Ambient Control .................................................. Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
Low Pressure Control ................................................ Economizer (Enthalpy Controlled) Downflow Only.......... Manual Fresh Air Damper............................................ L.P. (Propane) Kit ...................................................... Transition (Rectangular-Round) Downflow/Sideflow ...... Concentric Diffuser and Grille ...................................... High Pressure Control ................................................ Thermostat ..............................................................
Rheem Sales Company, Inc. P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.” PRINTED IN U.S.A.